Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Otolaryngol Head Neck Surg ; 53: 19160216241265684, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39092609

RESUMEN

BACKGROUND: The aim of this study is to describe the management and associated follow-up strategies adopted by thyroid surgeons with different surgical volumes when loss of signal (LOS) occurred on the first side of planned bilateral thyroid surgery, and to further define the consensus on intraoperative neuromonitoring (IONM) applications. METHODS: The International Neural Monitoring Study Group (INMSG) web-based survey was sent to 950 thyroid surgeons worldwide. The survey included information on the participants, IONM team/equipment/procedure, intraoperative/postoperative management of LOS, and management of LOS on the first side of thyroidectomy for benign and malignant disease. RESULTS: Out of 950, 318 (33.5%) respondents completed the survey. Subgroup analyses were performed based on thyroid surgery volume: <50 cases/year (n = 108, 34%); 50 to 100 cases/year (n = 69, 22%); and >100 cases/year (n = 141, 44.3%). High-volume surgeons were significantly (P < .05) more likely to perform the standard procedures (L1-V1-R1-S1-S2-R2-V2-L2), to differentiate true/false LOS, and to verify the LOS lesion/injury type. When LOS occurs, most surgeons arrange otolaryngologists or speech consultation. When first-side LOS occurs, not all respondents decided to perform stage contralateral surgery, especially for malignant patients with severe disease (eg, extrathyroid invasion and poorly differentiated thyroid cancer). CONCLUSIONS: Respondents felt that IONM was optimized when conducted under a collaborative team-based approach, and completed IONM standard procedures and management algorithm for LOS, especially those with high volume. In cases of first-site LOS, surgeons can determine the optimal management of disease-related, patient-related, and surgical factors. Surgeons need additional education on LOS management standards and guidelines to master their decision-making process involving the application of IONM.


Asunto(s)
Tiroidectomía , Humanos , Tiroidectomía/métodos , Encuestas y Cuestionarios , Monitorización Neurofisiológica Intraoperatoria , Enfermedades de la Tiroides/cirugía , Pautas de la Práctica en Medicina/estadística & datos numéricos , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Parálisis de los Pliegues Vocales/etiología , Femenino , Masculino
2.
Khirurgiia (Mosk) ; (7): 85-91, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-39008701

RESUMEN

OBJECTIVE: To evaluate the effectiveness of prevention of recurrent laryngeal nerve injury depending on thyroid gland lesion and extent of surgery. MATERIAL AND METHODS: There were 2412 thyroid surgeries between 2000 and 2020. Patients were divided into the main group (1689 patients) and the control group (729 patients). Patients with nodular thyroid gland lesions prevailed in both groups (987 (58.4%) and 415 (56.9%), respectively). All ones underwent atraumatic extrafascial desection and thyroid resection (ultrasonic scalpel). RESULTS. T: He upper laryngeal nerve injury occurred in 35 cases (1.4%). The number of surgeries with thyroid remnant preservation was significantly lower in the main group. The number of procedures with subtotal thyroid resection and thyroidectomy increased by 2.4 times (from 414 to 1010 operations, p<0.05). CONCLUSION: Improvement of surgical treatment of thyroid gland lesions consisting in new operative technique of recurrent laryngeal nerve isolation using ultrasonic scalpel reduces the incidence of recurrent laryngeal nerve injury from 2.3% to 1%. At the same time, the number of extended procedures in the main group significantly exceeded that in the control group (by 2.5 times).


Asunto(s)
Traumatismos del Nervio Laríngeo Recurrente , Glándula Tiroides , Tiroidectomía , Humanos , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Masculino , Tiroidectomía/métodos , Tiroidectomía/efectos adversos , Femenino , Persona de Mediana Edad , Adulto , Glándula Tiroides/cirugía , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Enfermedades de la Tiroides/cirugía , Federación de Rusia/epidemiología
3.
Am J Otolaryngol ; 45(5): 104420, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39067090

RESUMEN

BACKGROUND: Head and neck surgical simulation training (SST) is an important part in otolaryngology head and neck surgical education. In this study, we provide a live porcine model for SST in recurrent laryngeal nerve (RLN) and facial nerve (FN) dissection for otolaryngology head and neck residents. METHODS: A lecture with surgical manual is provided to illustrate the surgical landmarks of pig, and step-by-step procedures for thyroid and parotid surgery, as well as neck dissection. We used 4-month-old pig weighting 32 kg for the SST. The mentor demonstrated result of RLN injury with continuous nerve monitoring. Participants used monopolar stimulation probe (4 pulse/s, 100 µs, 3-8 mA; Medtronic) to identify and intermittent monitor the RLN and FN during the SST. After the dissection course, we conducted a questionnaire survey to check the effectiveness of this training model. RESULTS: Total 30 participants were recruited, including 16 female and 14 male resident doctors. There were 1, 4 and 25 learners for 3rd year, 4th and 5th years residents, respectively. Before this training course, 53 % (16/30) and 63 % (19/30) had successful experience in finding the RLN and FN, respectively. After the SST, all of our participants had successful identify the RLN and FN (p-value <0.01); all had positive response to stimulation and familiar with the procedure. CONCLUSIONS: The live porcine model is effectiveness in SST for RLN and FN dissection. Live porcine model with real-time RLN and FN monitoring should be provided for otolaryngology head and neck resident training.


Asunto(s)
Nervio Facial , Internado y Residencia , Otolaringología , Nervio Laríngeo Recurrente , Entrenamiento Simulado , Animales , Porcinos , Entrenamiento Simulado/métodos , Otolaringología/educación , Internado y Residencia/métodos , Nervio Facial/cirugía , Femenino , Humanos , Masculino , Nervio Laríngeo Recurrente/cirugía , Disección/educación , Modelos Animales , Competencia Clínica , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Disección del Cuello/educación
4.
J Otolaryngol Head Neck Surg ; 53: 19160216241265687, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39068537

RESUMEN

OBJECTIVES: A risk-adjusted analysis was completed using data from the National Surgical Quality Improvement Program (NSQIP) to compare the rates of recurrent laryngeal nerve injury in thyroid surgery using traditional versus alternative sources of cautery (defined as Harmonic Scalpel© and LigaSure©). METHODS: A retrospective cohort study was completed using the NSQIP database on adult patients who underwent total thyroidectomy, subtotal thyroidectomy, or completion thyroidectomy between 2016 and 2018. The primary outcome measure was recurrent laryngeal nerve injury. The exposure variable was use of conventional or alternative sources of cautery. Multivariable linear and logistic regression analyses were performed to control for potentially confounding variables. RESULTS: A total of 13,961 cases were analyzed; 9450 used alternative sources of cautery compared to 4511 where traditional cautery was used. There was no significant difference in rates of postoperative recurrent laryngeal nerve injury between the 2 sources of cautery compared. CONCLUSIONS: Risk of recurrent laryngeal nerve injury should not be a factor when choosing method of cautery for thyroid surgery. Therefore, other factors like cost-effectiveness can be considered.


Asunto(s)
Cauterización , Mejoramiento de la Calidad , Traumatismos del Nervio Laríngeo Recurrente , Tiroidectomía , Humanos , Tiroidectomía/métodos , Tiroidectomía/efectos adversos , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Anciano , Estados Unidos
5.
Ann Ital Chir ; 95(3): 281-283, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38918967

RESUMEN

The most important and serious complication of thyroid surgery is recurrent laryngeal nerve (RLN) injury, and it has been noted that this risk increases considerably in the presence of anatomical variations. Double recurrent laryngeal nerve (DRLN) is very rare among RLN anatomical variations. There are only a few case reports on DRLN in the literature It is crucial to possess surgical expertise and ensure complete visualization of the nerve to minimize the likelihood of RLN injury. Intraoperative nerve monitoring (IONM) is particularly useful in identifying anatomical variations. In a 54-year-old woman undergoing diagnostic left lobectomy+isthmectomy, a left DRLN was identified during intraoperative exploration and meticulous nerve exploration with the assistance of IONM monitoring verified that the impulse conduction in both branches was identical. The surgical procedure was successfully performed without causing any harm to the nerve. Based on the case reports in the literature and our experience with this patient, we believe that surgical expertise and the utilization of IONM can decrease RLN nerve damage and reveal its anatomical variations during thyroid surgery.


Asunto(s)
Nervio Laríngeo Recurrente , Neoplasias de la Tiroides , Tiroidectomía , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de la Tiroides/cirugía , Nervio Laríngeo Recurrente/anatomía & histología , Traumatismos del Nervio Laríngeo Recurrente/etiología , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Complicaciones Intraoperatorias/prevención & control , Complicaciones Intraoperatorias/etiología
6.
Surg Clin North Am ; 104(4): 767-777, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38944497

RESUMEN

Thyroidectomy is relatively safe and often can be done as a minimally invasive procedure. Although they may be associated with a learning curve, thoughtful use of intraoperative adjuncts such as energy devices, recurrent laryngeal nerve monitoring, and parathyroid autofluorescence have the potential to make incremental improvements in the safety and efficiency of thyroid surgery. Perhaps many of these adjuncts may be of greatest benefit when used routinely by less experienced surgeons or selectively in higher-risk operations, although their adoption in practice continues to increase overall.


Asunto(s)
Tiroidectomía , Humanos , Tiroidectomía/métodos , Monitoreo Intraoperatorio/métodos , Enfermedades de la Tiroides/cirugía , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Glándula Tiroides/cirugía , Imagen Óptica/métodos
7.
Surgery ; 176(3): 713-720, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38890101

RESUMEN

BACKGROUND: This study aimed to observe the occurrence of recurrent laryngeal nerve injury after McKeown esophagectomy for esophageal squamous cell carcinoma, as well as its recovery and influencing factors within 7 months after surgery. METHODS: From July 2020 to July 2021, among all patients who underwent minimally invasive McKeown esophagectomy, 90 patients who developed vocal cord paralysis after surgery were included in the study. These patients underwent endoscopic vocal cord function assessment every 1 to 2 months and continued until 7 months postoperatively. RESULTS: Among all 388 patients undergoing esophagectomy, 23.2% (90/388) of patients suffered postoperative vocal cord paralysis. Left, right, and bilateral injuries were confirmed in 73 (81.1%), 12 (13.3%), and 5 patients (5.6%), respectively. With a median recovery time being 183 days, the cumulative overall recovery rate was 65.4% at 7 months, 68.6% for the left side, 55.6% for the right, and 20.0% for bilateral injuries. In multivariable analysis, cervical paraoesophageal lymph node dissection and conventional thoracoscopic-assisted esophagectomy were demonstrated to be independent risk factors associated with non-recovery of vocal cord paralysis. CONCLUSIONS: After intensive endoscopic follow-up, a cumulative vocal cord paralysis recovery rate of 65.4% within 7 months was observed in patients after minimally invasive McKeown esophagectomy. Cervical paraoesophageal lymph node dissection and conventional thoracoscopic-assisted esophagectomy were demonstrated to be risk factors hindering vocal cord paralysis recovery.


Asunto(s)
Neoplasias Esofágicas , Esofagectomía , Complicaciones Posoperatorias , Recuperación de la Función , Traumatismos del Nervio Laríngeo Recurrente , Parálisis de los Pliegues Vocales , Humanos , Esofagectomía/efectos adversos , Esofagectomía/métodos , Parálisis de los Pliegues Vocales/etiología , Parálisis de los Pliegues Vocales/epidemiología , Masculino , Femenino , Persona de Mediana Edad , Neoplasias Esofágicas/cirugía , Factores de Riesgo , Anciano , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Traumatismos del Nervio Laríngeo Recurrente/etiología , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/epidemiología , Carcinoma de Células Escamosas de Esófago/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Adulto , Resultado del Tratamiento , Escisión del Ganglio Linfático/efectos adversos
8.
Am J Otolaryngol ; 45(5): 104358, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38754262

RESUMEN

OBJECTIVE: This case series study investigated the outcomes of an innovative approach, ansa cervicalis nerve (ACN)-to-recurrent laryngeal nerve (RLN) low-tension anastomosis. METHODS: Patients who received laryngeal nerve anastomosis between May 2015 and September 2021 at the facility were enrolled. The inclusion criteria were patients with RLN dissection and anastomosis immediately during thyroid surgery. Exclusion criteria were cases with anastomosis other than cervical loop-RLN anastomosis or pronunciation recovery time > 6 months. Patients admitted before January 2020 were assigned to group A which underwent the conventional tension-free anastomosis, and patients admitted after January 2020 were group B and underwent the innovative low-tension anastomosis (Dong's method). RESULTS: A total of 13 patients were included, 11 patients received unilateral surgery, and 2 underwent bilateral surgery. For patients who underwent unilateral anastomosis, group B had a significantly higher percentage of normal pronunciation via GRBAS scale (83.3 % vs. 0 %, p = 0.015) and voice handicap index (66.7 % vs. 0 %, p = 0.002), and shorter recovery time in pronunciation (median: 1-day vs. 4 months, p = 0.001) than those in group A after surgery. CONCLUSIONS: ACNs-to-RLN low-tension anastomosis with a laryngeal segment ≤1 cm (Dong's method) significantly improves postoperative pronunciation and recovery time. The results provide clinicians with a new strategy for ACN -to-RLN anastomosis during thyroid surgery.


Asunto(s)
Anastomosis Quirúrgica , Fonación , Nervio Laríngeo Recurrente , Tiroidectomía , Humanos , Anastomosis Quirúrgica/métodos , Femenino , Masculino , Persona de Mediana Edad , Nervio Laríngeo Recurrente/cirugía , Tiroidectomía/métodos , Fonación/fisiología , Adulto , Recuperación de la Función , Traqueotomía/métodos , Resultado del Tratamiento , Anciano , Plexo Cervical/cirugía , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología
9.
Surg Innov ; 31(4): 355-361, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38632109

RESUMEN

INTRODUCTION: Recurrent laryngeal nerve (RNL) identification constitutes the standard in thyroidectomy. Intraoperative nerve monitoring (IONM) has been introduced as a complementary tool for RLN functionality evaluation. The aim of this study is to establish how routine use of IONM can affect the learning curve (LC) in thyroidectomy. METHODS: Patients undergoing total thyroidectomy performed by surgery residents in their learning curve course in 2 academic hospitals, were divided into 2 groups: Group A, including 150 thyroidectomies performed without IONM by 3 different residents, and Group B, including 150 procedures with routine use of intermittent IONM, by other 3 different residents. LC was measured by comparing operative time (OT), its stabilization during the development of the LC, perioperative complication rate. RESULTS: As previously demonstrated, the LC was achieved after 30 procedures, in both groups, with no differences due to the use of IONM. Similarly, there were no significant differences among the 2 groups, and between subgroups independently matched, for both OT and complications, even when comparing RLN palsy. Direct nerve visualization and IONM assessment rates were comparable in all groups, and no bilateral RLN palsy (transient or permanent) were reported. No case of interrupted procedure to unilateral lobectomy, due to evidence of RLN injury, was reported. CONCLUSIONS: The study demonstrates that the use of IONM thyroid surgery, despite requiring a specific training with experienced surgeons, does not particularly affect the learning curve of residents approaching this kind of surgery, and for this reason its routine use should be encouraged even for trainees.


Asunto(s)
Internado y Residencia , Curva de Aprendizaje , Tiroidectomía , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Monitoreo Intraoperatorio/métodos , Monitorización Neurofisiológica Intraoperatoria/métodos , Cirugía General/educación , Anciano , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Estudios Retrospectivos
10.
JAMA Otolaryngol Head Neck Surg ; 150(6): 509-516, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38662382

RESUMEN

Importance: Use of intraoperative neuromonitoring (IONM) during thyroidectomy can nearly eliminate the risk of postoperative bilateral vocal cord palsy (VCP) by indicating staged surgery in cases of loss of signal (LOS) on the first side of planned total thyroidectomy. However, aborting planned total thyroidectomy may lead to persistence of symptoms, delay in adjuvant treatment, and patient inconvenience and distress. There are few data to guide a selective approach to total thyroidectomy in patients with first-side LOS. Objective: To investigate outcomes of immediate bilateral surgery in patients undergoing total thyroidectomy with first-side LOS. Design, Setting, and Participants: This cohort study was a retrospective review of outcomes for patients undergoing thyroidectomy between January 2016 and July 2023 at an academic tertiary referral center for thyroid surgery. Consecutive patients scheduled for total thyroidectomy using IONM were included. Exclusion criteria were preoperative VCP, deliberate sacrifice of recurrent laryngeal nerve (RLN), inadvertent RLN resection, and surgery performed without IONM. Exposures: Total thyroidectomy performed using IONM. Main Outcome Measures: Vocal mobility on first postoperative day as assessed by flexible laryngoscopy; secondary outcome measures included subjective voice assessment, other postoperative complications, and long-term vocal mobility. Results: Among 400 patients undergoing planned total thyroidectomy (mean age, 50.5 years [range, 4-88 years]; 318 female [79.5%]), 51 (12.8%) had first-side LOS, of whom 37 (9.3%) had persistent LOS. Twenty-nine patients (56% of procedures with first-side LOS, including 18 with persistent LOS) proceeded to immediate total thyroidectomy. Postoperatively, 16 patients (55% of patients undergoing total thyroidectomy following first-side LOS, including 14 of 18 with persistent LOS) had impaired vocal mobility. One patient had bilateral VCP that did not require tracheostomy, and 2 had postoperative hypoparathyroidism. Of those whose surgery was aborted after first-side LOS, 8 of 22 (36%) underwent completion thyroidectomy at a later stage. In those undergoing completion thyroidectomy, 2 of 8 (25%) had temporary VCP after the second surgery, 2 (25%) had permanent hypoparathyroidism, and 1 (12.5%) developed inoperable cancer. Postoperative VCP was fully reversible in all but 1 patient. Conclusion and Relevance: Among patients planned for total thyroidectomy who develop first-side LOS, immediate total thyroidectomy may be considered among those who have pressing reasons for same, and where surgical difficulties might be anticipated in a secondary surgery.


Asunto(s)
Complicaciones Posoperatorias , Tiroidectomía , Parálisis de los Pliegues Vocales , Humanos , Tiroidectomía/métodos , Tiroidectomía/efectos adversos , Femenino , Masculino , Parálisis de los Pliegues Vocales/etiología , Parálisis de los Pliegues Vocales/prevención & control , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Laringoscopía , Anciano , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Monitorización Neurofisiológica Intraoperatoria/métodos , Resultado del Tratamiento , Anciano de 80 o más Años , Adolescente , Monitoreo Intraoperatorio/métodos
11.
J Robot Surg ; 18(1): 136, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520624

RESUMEN

Minimally invasive thyroidectomy (MIT) is increasingly being used for the thyroid tumors. The comparison of bilateral axillo-breast approach robotic thyroidectomy (BABART) with other MIT has not yet led to a unified conclusion with regard to surgical outcomes. To conduct a systematic review and meta-analysis of the literature on the surgical outcomes of BABART compared with MIT. We performed a systematic search in PubMed, Web of Science, Embase and Cochrane Library database for randomized control trials (RCTs) and non-RCTs that compare BABART to MIT. The primary outcomes included perioperative, postoperative complications. The odds ratio (OR) and mean difference (MD) were applied for the comparison of dichotomous and continuous variables with 95% confidence intervals (CIs). Nine studies, comprising 3645 patients, were included in the meta-analysis. Our findings indicated that there were no significant differences in hospital stay, number of retrieved lymph nodes, recurrent laryngeal nerve (RLN) injury, and vocal cord dysfunction between BABRT and MIT. However, BABART was associated with a shorter operation time (MD = - 21.45 min, 95% CI [- 47.27, 4.38], p = 0.1) and lower rate of permanent hypoparathyroidism (OR = 0.42, 95% CI [0.20, 0.88], p = 0.02). Additionally, the MIT group had reduced postoperative pain score (MD = 0.45, 95% CI [0.02, 0.88], p = 0.04) and lower rate of hypocalcemia (OR = 2.31, 95% CI [1.04, 5.13], p = 0.04) than the BABART group. In comparison with MIT, BABART exhibits better results in terms of operative time and the rate of permanent hypoparathyroidism, with no significant difference in hospital stay, number of retrieved lymph nodes, RLN injury, and vocal cord dysfunction. However, the postoperative pain score and the rate of hypocalcemia of MIT are slightly better that of BABART.


Asunto(s)
Axila , Tiempo de Internación , Procedimientos Quirúrgicos Mínimamente Invasivos , Tempo Operativo , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Robotizados , Tiroidectomía , Humanos , Tiroidectomía/métodos , Tiroidectomía/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Tiempo de Internación/estadística & datos numéricos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Resultado del Tratamiento , Mama/cirugía , Neoplasias de la Tiroides/cirugía , Femenino , Hipoparatiroidismo/prevención & control , Hipoparatiroidismo/etiología , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Hipocalcemia/etiología , Hipocalcemia/prevención & control , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Masculino
13.
Am J Otolaryngol ; 45(3): 104233, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38417263

RESUMEN

OBJECTIVE: Neural integrity monitoring (NIM) endotracheal tubes are widely used to provide intraoperative monitoring of the recurrent laryngeal nerve during certain neck surgeries, especially thyroidectomy, in order to reduce the risk of nerve injury and subsequent vocal fold paralysis. The unique design of NIM tubes and the increased technical skill required for correct placement compared to standard endotracheal tubes may increase the risk of upper aerodigestive tract soft tissue injury. This study aims to describe adverse events related to NIM endotracheal tubes. STUDY DESIGN: Retrospective cross-sectional study. SETTING: The US Food and Drug Administration's MAUDE database (2010-2022); (Manufacturer and User Facility Device Experience). METHODS: The MAUDE database was queried for reports of adverse events that resulted in patient soft tissue injury involving the use of endotracheal tubes approved by the Food and Drug Administration. RESULTS: There were 28 reported soft tissue injuries, with all events being related to the NIM EMG family of endotracheal tubes manufactured by Medtronic Xomed, Inc. Overall, 24 were categorized as device-related adverse events, and 4 were unspecified in the event description. The most common soft tissue injuries were edema (n = 7) and perforation (n = 7), each accounting for 25 % of adverse events. The second most common injury type was laceration (n = 4), representing 14 % of all adverse events. Overall, 9 patients (32 %) in our cohort required a surgical intervention to treat their injuries, which consisted of 6 tracheotomies and 3 instances of suture repair. CONCLUSIONS: The most commonly reported types of soft tissue injury included edema and perforation, followed by laceration. Increased awareness of device-related patient injuries associated with NIM endotracheal tubes can be used to better inform surgeons and anesthesiologists during the process of intubation and surgical decision-making.


Asunto(s)
Bases de Datos Factuales , Intubación Intratraqueal , Traumatismos de los Tejidos Blandos , Humanos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Estudios Retrospectivos , Estudios Transversales , Traumatismos de los Tejidos Blandos/etiología , Traumatismos de los Tejidos Blandos/prevención & control , Estados Unidos , Masculino , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Traumatismos del Nervio Laríngeo Recurrente/etiología , Femenino , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/instrumentación , Persona de Mediana Edad , United States Food and Drug Administration
14.
Surg Endosc ; 38(3): 1406-1413, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38168731

RESUMEN

BACKGROUND: Recurrent laryngeal nerve (RLN) injury after thyroidectomy is relatively common. Locating the RLN prior to thyroid dissection is paramount to avoid injury. We developed a fluorescence imaging system that permits nerve autofluorescence. We aimed to determine the sensitivity and specificity of fluorescence imaging at detecting the RLN relative to thyroid and other background tissue and compared it to white light. METHODS: In this prospective study, 65 patients underwent thyroidectomy from January to April 2022 (16 bilateral thyroid resections) using white and fluorescent light. Fluorescence intensity [relative fluorescence units (RFU)] was recorded for RLN, thyroid, and background. RFU mean, minimum, and maximum values were calculated using Image J software. Thirty randomly selected pairs of white and fluorescent light images were independently reviewed by two examiners to compare RLN detection rate, number of branches, and length and minimum width of nerves visualized. Parametric and nonparametric statistical analysis was performed. RESULTS: All 81 RNLs observed were visualized more clearly under fluorescence (mean intensity, µ = 134.3 RFU) than either thyroid (µ = 33.7, p < 0.001) or background (µ = 14.4, p < 0.001). Forest plots revealed no overlap between RLN intensity and that of either other tissue. Sensitivity and specificity for RLN were 100%. All 30 RLNs and all 45 nerve branches were clearly visualized under fluorescence, versus 17 and 22, respectively, with white light (both p < 0.001). Visible nerve length was 2.5 × as great with fluorescence as with white light (µ = 1.90 vs. 0.76 cm, p < 0.001). CONCLUSIONS: In 65 patients and 81 nerves, RLN detection was markedly and consistently enhanced with autofluorescence neuro-imaging during thyroidectomy, with 100% sensitivity and specificity.


Asunto(s)
Traumatismos del Nervio Laríngeo Recurrente , Tiroidectomía , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Estudios Prospectivos , Nervio Laríngeo Recurrente/diagnóstico por imagen , Nervio Laríngeo Recurrente/cirugía , Glándula Tiroides , Traumatismos del Nervio Laríngeo Recurrente/etiología , Traumatismos del Nervio Laríngeo Recurrente/prevención & control
16.
Biomédica (Bogotá) ; 35(3): 363-371, jul.-sep. 2015. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-765465

RESUMEN

Introduction: Thyroidectomy is a common surgery. Routine searching of the recurrent laryngeal nerve is the most important strategy to avoid palsy. Neuromonitoring has been recommended to decrease recurrent laryngeal nerve palsy. Objective: To assess if neuromonitoring of recurrent laryngeal nerve during thyroidectomy is cost-effective in a developing country. Materials and methods: We designed a decision analysis to assess the cost-effectiveness of recurrent laryngeal nerve neuromonitoring. For probabilities, we used data from a meta-analysis. Utility was measured using preference values. We considered direct costs. We conducted a deterministic and a probabilistic analysis. Results: We did not find differences in utility between arms. The frequency of recurrent laryngeal nerve injury was 1% in the neuromonitor group and 1.6% for the standard group. Thyroidectomy without monitoring was the less expensive alternative. The incremental cost-effectiveness ratio was COP$ 9,112,065. Conclusion: Routine neuromonitoring in total thyroidectomy with low risk of recurrent laryngeal nerve injury is neither cost-useful nor cost-effective in the Colombian health system.


Introducción. La tiroidectomía es una cirugía común. La búsqueda rutinaria del nervio laríngeo inferior es la estrategia más importante para evitar la parálisis. Objetivo. Evaluar el costo-efectividad en un país en desarrollo de la monitorización neurológica del nervio laríngeo inferior durante la tiroidectomía. Materiales y métodos. Se diseñó un análisis de decisiones para evaluar el costo-efectividad de la monitorización neurológica del nervio laríngeo inferior. Para las probabilidades se usaron datos de un meta-análisis. La utilidad se determinó con medidas de preferencia. Se incluyeron los costos directos. Se hizo un análisis determinístico y probabilístico. Resultados. No se encontraron diferencias en la utilidad entre las estrategias. La frecuencia de la lesión de este nervio fue de 1 % en el grupo bajo monitorización neurológica y de 1,6 % en el grupo de control. La tiroidectomía sin monitorización fue la alternativa menos costosa. La razón de costo-efectividad incremental fue de COP$ 9.112.065 Conclusión. La monitorización neurológica rutinaria en la tiroidectomía total con bajo riesgo de lesión del nervio laríngeo inferior, no es útil con relación a su costo ni costo-efectiva en el sistema de salud colombiano.


Asunto(s)
Humanos , Nervio Laríngeo Recurrente/fisiología , Tiroidectomía/economía , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Monitorización Neurofisiológica Intraoperatoria/economía , Complicaciones Intraoperatorias/prevención & control , Tiroidectomía/efectos adversos , Traqueostomía/economía , Metaanálisis como Asunto , Probabilidad , Técnicas de Apoyo para la Decisión , Análisis Costo-Beneficio , Colombia , Procedimientos Innecesarios/economía , Países en Desarrollo , Estimulación Eléctrica/instrumentación , Electromiografía/economía , Electromiografía/instrumentación , Electromiografía/métodos , Monitorización Neurofisiológica Intraoperatoria/instrumentación , Monitorización Neurofisiológica Intraoperatoria/métodos , Intubación Intratraqueal/instrumentación , Tiempo de Internación/economía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...