Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 365
Filtrar
1.
Drug Discov Ther ; 18(3): 188-193, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38880603

RESUMEN

Wheelchair cushions are recommended to be used with wheelchair and can protect the buttocks from pain and injury by relieving interface pressure for wheelchair users. However, further investigations are required for proper use in response to the development of new types of wheelchair cushions. The objective of this study was to evaluate physical characteristics of wheelchair cushions by comparing pressure redistributing effects of four types of cushions. The participants were 16 healthy adults who consented to participate in this study. A pressure mapping system (CONFORMat, Nitta Corp.) was used for the measurements. Pressure at ischium was measured immediately after the stabilization of the sitting posture and 10 minutes after. The pressure at ischium significantly decreased with any wheelchair cushions (P < 0.01). A significant negative correlation between body mass index and pressure at ischium was observed without a wheelchair cushion (r = - 0.70), however, the correlation disappeared upon use of a wheelchair cushion. The pressure at ischium increased over time with cushions of urethane, air, and urethane-air hybrid while that with the 3D thermoplastic elastomer cushion did not, and the change in the pressure was statistically less than that in other cushions (P < 0.01). Use of wheelchair cushions was effective in redistribution of the pressure at ischium, and the overtime change in the pressure depends on the type of used cushions.


Asunto(s)
Elastómeros , Diseño de Equipo , Isquion , Presión , Silla de Ruedas , Humanos , Adulto , Elastómeros/química , Masculino , Femenino , Uretano/química , Adulto Joven , Índice de Masa Corporal , Úlcera por Presión/prevención & control
2.
Biomater Adv ; 162: 213923, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38875803

RESUMEN

Bioengineering seeks to replicate biological tissues exploiting scaffolds often based on polymeric biomaterials. Digital light processing (DLP) has emerged as a potent technique to fabricate tissue engineering (TE) scaffolds. However, the scarcity of suitable biomaterials with desired physico-chemical properties along with processing capabilities limits DLP's potential. Herein, we introduce acrylate-endcapped urethane-based polymers (AUPs) for precise physico-chemical tuning while ensuring optimal computer-aided design/computer-aided manufacturing (CAD/CAM) mimicry. Varying the polymer backbone (i.e. poly(ethylene glycol) (PEG) versus poly(propylene glycol) (PPG)) and photo-crosslinkable endcap (i.e. di-acrylate versus hexa-acrylate), we synthesized a series of photo-crosslinkable materials labeled as UPEG2, UPEG6, UPPG2 and UPPG6. Comprehensive material characterization including physico-chemical and biological evaluations, was followed by a DLP processing parametric study for each material. The impact of the number of acrylate groups per polymer (2 to 6) on the physico-chemical properties was pronounced, as reflected by a reduced swelling, lower water contact angles, accelerated crosslinking kinetics, and increased Young's moduli upon increasing the acrylate content. Furthermore, the different polymer backbones also exerted a substantial effect on the properties, including the absence of crystallinity, remarkably reduced swelling behaviors, a slight reduction in Young's modulus, and slower crosslinking kinetics for UPPG vs UPEG. The mechanical characteristics of DLP-printed samples showcased the ability to tailor the materials' stiffness (ranging from 0.4 to 5.3 MPa) by varying endcap chemistry and/or backbone. The in vitro cell assays confirmed biocompatibility of the material as such and the DLP-printed discs. Furthermore, the structural integrity of 3D scaffolds was preserved both in dry and swollen state. By adjusting the backbone chemistry or acrylate content, the post-swelling dimensions could be customized towards the targeted application. This study showcases the potential of these materials offering tailorable properties to serve many biomedical applications such as cartilage TE.


Asunto(s)
Acrilatos , Materiales Biocompatibles , Polietilenglicoles , Uretano , Acrilatos/química , Polietilenglicoles/química , Materiales Biocompatibles/química , Uretano/química , Ingeniería de Tejidos/métodos , Humanos , Andamios del Tejido/química , Luz , Ensayo de Materiales/métodos , Polímeros/química , Glicoles de Propileno/química , Poliuretanos/química
3.
Acta Biomater ; 183: 130-145, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38815684

RESUMEN

Osteoarthritis (OA) poses significant therapeutic challenges, particularly OA that affects the hand. Currently available treatment strategies are often limited in terms of their efficacy in managing pain, regulating invasiveness, and restoring joint function. The APRICOTⓇ implant system developed by Aurora Medical Ltd (Chichester, UK) introduces a minimally invasive, bone-conserving approach for treating hand OA (https://apricot-project.eu/). By utilizing polycarbonate urethane (PCU), this implant incorporates a caterpillar track-inspired design to promote the restoration of natural movement to the joint. Surface modifications of PCU have been proposed for the biological fixation of the implant. This study investigated the biocompatibility of PCU alone or in combination with two surface modifications, namely dopamine-carboxymethylcellulose (dCMC) and calcium-phosphate (CaP) coatings. In a rat soft tissue model, native and CaP-coated PCU foils did not increase cellular migration or cytotoxicity at the implant-soft tissue interface after 3 d, showing gene expression of proinflammatory cytokines similar to that in non-implanted sham sites. However, dCMC induced an amplified initial inflammatory response that was characterized by increased chemotaxis and cytotoxicity, as well as pronounced gene activation of proinflammatory macrophages and neoangiogenesis. By 21 d, inflammation subsided in all the groups, allowing for implant encapsulation. In a rat bone model, 6 d and 28 d after release of the periosteum, all implant types were adapted to the bone surface with a surrounding fibrous capsule and no protracted inflammatory response was observed. These findings demonstrated the biocompatibility of native and CaP-coated PCU foils as components of APRICOTⓇ implants. STATEMENT OF SIGNIFICANCE: Hand osteoarthritis treatments require materials that minimize irritation of the delicate finger joints. Differing from existing treatments, the APRICOTⓇ implant leverages polycarbonate urethane (PCU) for minimally invasive joint replacement. This interdisciplinary, preclinical study investigated the biocompatibility of thin polycarbonate urethane (PCU) foils and their surface modifications with calcium-phosphate (CaP) or dopamine-carboxymethylcellulose (dCMC). Cellular and morphological analyses revealed that both native and Ca-P coated PCU elicit transient inflammation, similar to sham sites, and a thin fibrous encapsulation in soft tissues and on bone surfaces. However, dCMC surface modification amplified initial chemotaxis and cytotoxicity, with pronounced activation of proinflammatory and neoangiogenesis genes. Therefore, native and CaP-coated PCU possess sought-for biocompatible properties, crucial for patient safety and performance of APRICOTⓇ implant.


Asunto(s)
Fosfatos de Calcio , Animales , Masculino , Ratas , Fosfatos de Calcio/química , Fosfatos de Calcio/farmacología , Dopamina/metabolismo , Dopamina/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Cemento de Policarboxilato/química , Prótesis Articulares , Carboximetilcelulosa de Sodio/química , Carboximetilcelulosa de Sodio/farmacología , Uretano/química
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124357, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38692110

RESUMEN

This study described the preparation of an azide covalent organic framework-embedded molecularly imprinted polymers (COFs(azide)@MIPs) platform for urea adsorption and indirect ethyl carbamate (EC) removal from Chinese yellow rice wine (Huangjiu). By modifying the pore surface of COFs using the copper-catalyzed azide-alkyne cycloaddition (CuAAC) reaction, COFs(azide) with a high fluorescence quantum yield and particular recognition ability were inventively produced. In order to selectively trap urea, the COFs(azide) were encased in an imprinted shell layer via imprinting technology. With a detection limit (LOD) of 0.016 µg L-1 (R2 = 0.9874), the COFs(azides)@MIPs demonstrated a good linear relationship with urea in the linear range of 0-5 µg L-1. Using real Huangjiu samples, the spiking recovery trials showed the viability of this sensing platform with recoveries ranging from 88.44 % to 109.26 % and an RSD of less than 3.40 %. The Huangjiu processing model system achieved 38.93 % EC reduction by COFs(azides)@MIPs. This research will open up new avenues for the treatment of health problems associated with fermented alcoholic beverages, particularly Huangjiu, while also capturing and removing hazards coming from food.


Asunto(s)
Polímeros Impresos Molecularmente , Urea , Uretano , Vino , Uretano/análisis , Uretano/química , Polímeros Impresos Molecularmente/química , Urea/análisis , Urea/química , Vino/análisis , Espectrometría de Fluorescencia/métodos , Azidas/química , Límite de Detección , Adsorción , Estructuras Metalorgánicas/química , Impresión Molecular/métodos
5.
Food Chem ; 453: 139626, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-38759440

RESUMEN

Ethyl carbamate (EC) is a carcinogen widely found in the fermentation process of Baijiu. Herein, we construct a molecularly imprinted polymers/MXene/cobalt (II) based zeolitic imidazolate frameworks (MIP/MXene/ZIF-67) nano-enzyme sensor for the detection of EC during Baijiu production. The ZIF-67 is synthesized in situ on the MXene nanosheets to provide a superior catalytic activity to H2O2 and amplify the electrochemical signal. The MIP is prepared by the polymerization reaction to recognize EC. Owing to the interaction between EC and EC-MIP, the interferences are effectively eliminated, greatly improving the accuracy of the expected outcome. This approach attains an ultrasensitive assay of EC ranging from 8.9 µg/L to 44.5 mg/L with detection limit of 0.405 µg/L. The accuracy of this method is confirmed by the recovery experiment with good recoveries from 95.07% to 107.41%. This method is applied in natural EC analyses, and the results are consistent with certified gas chromatograph- mass spectrometer.


Asunto(s)
Técnicas Electroquímicas , Contaminación de Alimentos , Impresión Molecular , Uretano , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Uretano/análisis , Uretano/química , Contaminación de Alimentos/análisis , Catálisis , Polímeros Impresos Molecularmente/química , Límite de Detección
6.
J Biomed Mater Res A ; 112(9): 1424-1435, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38465895

RESUMEN

Currently available focal knee resurfacing implants (FKRIs) are fully or partially composed of metals, which show a large disparity in elastic modulus relative to bone and cartilage tissue. Although titanium is known for its excellent osseointegration, the application in FKRIs can lead to potential stress-shielding and metal implants can cause degeneration of the opposing articulating cartilage due to the high resulting contact stresses. Furthermore, metal implants do not allow for follow-up using magnetic resonance imaging (MRI).To overcome the drawbacks of using metal based FKRIs, a biomimetic and MRI compatible bi-layered non-resorbable thermoplastic polycarbonate-urethane (PCU)-based FKRI was developed. The objective of this preclinical study was to evaluate the mechanical properties, biocompatibility and osteoconduction of a novel Bionate® 75D - zirconium oxide (B75D-ZrO2) composite material in vitro and the osseointegration of a B75D-ZrO2 composite stem PCU implant in a caprine animal model. The tensile strength and elastic modulus of the B75D-ZrO2 composite were characterized through in vitro mechanical tests under ambient and physiological conditions. In vitro biocompatibility and osteoconductivity were evaluated by exposing human mesenchymal stem cells to the B75D-ZrO2 composite and culturing the cells under osteogenic conditions. Cell activity and mineralization were assessed and compared to Bionate® 75D (B75D) and titanium disks. The in vivo osseointegration of implants containing a B75D-ZrO2 stem was compared to implants with a B75D stem and titanium stem in a caprine large animal model. After a follow-up of 6 months, bone histomorphometry was performed to assess the bone-to-implant contact area (BIC). Mechanical testing showed that the B75D-ZrO2 composite material possesses an elastic modulus in the range of the elastic modulus reported for trabecular bone. The B75D-ZrO2 composite material facilitated cell mediated mineralization to a comparable extent as titanium. A significantly higher bone-to-implant contact (BIC) score was observed in the B75D-ZrO2 implants compared to the B75D implants. The BIC of B75D-ZrO2 implants was not significantly different compared to titanium implants. A biocompatible B75D-ZrO2 composite approximating the elastic modulus of trabecular bone was developed by compounding B75D with zirconium oxide. In vivo evaluation showed an significant increase of osseointegration for B75D-ZrO2 composite stem implants compared to B75D polymer stem PCU implants. The osseointegration of B75D-ZrO2 composite stem PCU implants was not significantly different in comparison to analogous titanium stem metal implants.


Asunto(s)
Ensayo de Materiales , Oseointegración , Cemento de Policarboxilato , Uretano , Circonio , Circonio/química , Circonio/farmacología , Animales , Oseointegración/efectos de los fármacos , Uretano/química , Cemento de Policarboxilato/química , Prótesis de la Rodilla , Humanos , Cabras , Materiales Biocompatibles/química , Células Madre Mesenquimatosas/citología
7.
Org Biomol Chem ; 20(16): 3303-3310, 2022 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-35229099

RESUMEN

This study demonstrated the rapid dual activation (10 s, 20 °C) of a combination of an α-amino acid N-carboxyanhydride and alkyl chloroformate in the synthesis of a urethane-protected α-amino acid N-carboxyanhydride in a micro-flow reactor. The key to success was the combined use of two amines that activated both substrates with proper timing. Three amines, i-Pr2NEt, Me2NBn, or N-ethylmorpholine, were used with pyridine in accordance with the steric bulkiness of a side chain in the α-amino acid N-carboxyanhydride. A variety of 16 urethane-protected α-amino acid N-carboxyanhydrides were synthesized in high yields. The role of amines was investigated based on the measurement of the time-dependent (0.5 to 10 s) decrease of α-amino acid N-carboxyanhydrides and alkyl chloroformates in the presence of amines via flash mixing technology using a micro-flow reactor. It was suggested that the in situ generated acylpyridinium cation was highly active and less prone to causing undesired decomposition compared with the acylammonium cation examined in this study. Thus, even at a very low concentration, the acylpyridinium cation facilitated the desired coupling reaction.


Asunto(s)
Péptidos , Uretano , Amidas , Aminas , Aminoácidos/química , Ésteres , Péptidos/química , Uretano/química
8.
J Biomed Mater Res B Appl Biomater ; 110(8): 1839-1852, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35226412

RESUMEN

Hydrogels are very promising human cartilage replacement materials since they are able to mimic its structure and properties. Besides, they can be used as platforms for drug delivery to reduce inflammatory postsurgical reactions. Polycarbonate urethane (PCU) has been used in orthopedic applications due to its long-term biocompatibility and bio-durability. In this work, PCU-based hydrogels with the ability to release an anti-inflammatory (diclofenac) were developed, for the first time, for such purpose. The materials were reinforced with different amounts of cellulose acetate (CA, 10%, 15%, and 25% w/w) or carbon nanotubes (CNT, 1% and 2% w/w) in order to improve their mechanical properties. Samples were characterized in terms of compressive and tensile mechanical behavior. It was found that 15% CA and 2% CNT reinforcement led to the best mechanical properties. Thus, these materials were further characterized in terms of morphology, wettability, and friction coefficient (CoF). Contrarily to CNTs, the addition of CA significantly increased the material's porosity. Both materials became more hydrophilic, and the CoF slightly increased for PCU + 15%CA. The materials were loaded by soaking with diclofenac, and drug release experiments were conducted. PCU, PCU + 15%CA and PCU + 2%CNT presented similar release profiles, being able to ensure a controlled release of DFN for at least 4 days. Finally, in vitro cytotoxicity tests using human chondrocytes were also performed and confirmed a high biocompatibility for the three studied materials.


Asunto(s)
Nanotubos de Carbono , Uretano , Cartílago , Diclofenaco/farmacología , Humanos , Hidrogeles/química , Nanotubos de Carbono/química , Cemento de Policarboxilato , Uretano/química , Uretano/farmacología
9.
Int J Biol Macromol ; 194: 452-460, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34822833

RESUMEN

Halochromic agent is easy to fall off from the surface of colorimetric membranes during fish freshness monitoring, which would decay the test accuracy. In order to increase its anchoring, citrated methacrylated urethane (CMU) synthesized by using tributyl citrate, ß-hydroxyethyl methacrylate and diphenyl-methane-diisocyanate as a halochromic agent was grafted on polylactic acid (PLA). The CMU grafted PLA (PLA-CMU) together with tetrabutylammonium chloride (TBAC) prepared colorimetric membranes via electrospinning. 1H NMR and FTIR analysis showed successful bonding between CMU and PLA, and PLA-CMU grafting efficiency reached to the maximum value of 11.15%. Moreover, DSC confirmed that PLA-CMU existed low cold-crystallization temperature due to the excellent compatibility of CMU with PLA, which enhanced the anchoring of CMU effectively. Nanofiber-based PLA-CMU/TBAC colorimetric membrane enhanced the probability of molecules being captured due to its porous structure and large specific surface area. In addition, the increase in hydrophilicity of the membrane can provide a microenvironment for liquid phase reaction, exhibiting obvious color-changing sensitivity during cod freshness monitoring, from white color to light orange or pink with the deterioration of cod at 25 °C and 4 °C respectively. The results demonstrate PLA-CMU/TBAC colorimetric membranes would provide a simple and promising strategy for monitoring fish freshness.


Asunto(s)
Colorimetría/métodos , Embalaje de Alimentos/métodos , Inocuidad de los Alimentos/métodos , Almacenamiento de Alimentos/métodos , Gadiformes/metabolismo , Animales , Membranas/química , Poliésteres/química , Uretano/química
10.
Methods Mol Biol ; 2375: 47-59, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34591298

RESUMEN

There is a tremendous clinical need for synthetic vascular grafts either for bypass procedure or vascular access during hemodialysis. However, currently, there is no small-diameter vascular graft commercially available to meet long-term patency requirement due to frequent thrombus formation and intimal hyperplasia. This chapter describes the fabrication of electrospun small-diameter polycarbonate-urethane (PCU) vascular graft with a biomimetic fibrous structure. Additionally, the surface of the vascular graft is aminated via plasma treatment for the subsequently end-point heparin immobilization to enhance antithrombosis property.


Asunto(s)
Uretano/química , Prótesis Vascular , Heparina , Cemento de Policarboxilato , Grado de Desobstrucción Vascular
11.
Adv Mater ; 33(40): e2103826, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34396591

RESUMEN

Bioinspired elastomeric structural adhesives can provide reversible and controllable adhesion on dry/wet and synthetic/biological surfaces for a broad range of commercial applications. Shape complexity and performance of the existing structural adhesives are limited by the used specific fabrication technique, such as molding. To overcome these limitations by proposing complex 3D microstructured adhesive designs, a 3D elastomeric microstructure fabrication approach is implemented using two-photon-polymerization-based 3D printing. A custom aliphatic urethane-acrylate-based elastomer is used as the 3D printing material. Two designs are demonstrated with two combined biological inspirations to show the advanced capabilities enabled by the proposed fabrication approach and custom elastomer. The first design focuses on springtail- and gecko-inspired hybrid microfiber adhesive, which has the multifunctionalities of side-surface liquid super-repellency, top-surface liquid super-repellency, and strong reversible adhesion features in a single fiber array. The second design primarily centers on octopus- and gecko-inspired hybrid adhesive, which exhibits the benefits of both octopus- and gecko-inspired microstructured adhesives for strong reversible adhesion on both wet and dry surfaces, such as skin. This fabrication approach could be used to produce many other 3D complex elastomeric structural adhesives for future real-world applications.


Asunto(s)
Adhesivos/química , Elastómeros/química , Impresión Tridimensional , Acrilatos/química , Materiales Biomiméticos/química , Módulo de Elasticidad , Propiedades de Superficie , Uretano/química
12.
J Mater Sci Mater Med ; 32(8): 86, 2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34313865

RESUMEN

Over the years, several devices have been created (and the development of many others is currently in progress) to be in permanent contact with blood: mechanical circulatory supports represent an example thereof. The hemocompatibility of these devices largely depends on the chemical composition of blood-contacting components. In the present work, an innovative material (hybrid membrane) is proposed to fabricate the inner surfaces of a pulsatile ventricular chamber: it has been obtained by coupling a synthetic polymer (e.g., commercial polycarbonate urethane) with decellularized porcine pericardium. The hemocompatibility of the innovative material has been preliminarily assessed by measuring its capacity to promote thrombin generation and induce platelet activation. Our results demonstrated the blood compatibility of the proposed hybrid membrane.


Asunto(s)
Plaquetas/efectos de los fármacos , Sangre/efectos de los fármacos , Materiales Biocompatibles Revestidos , Membranas Artificiales , Activación Plaquetaria , Adulto , Animales , Sangre/metabolismo , Femenino , Humanos , Ensayo de Materiales/métodos , Pericardio/química , Pericardio/efectos de los fármacos , Cemento de Policarboxilato/química , Polímeros/química , Estrés Mecánico , Propiedades de Superficie , Porcinos , Trombina/química , Uretano/química
13.
J Mater Sci Mater Med ; 32(8): 85, 2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34297226

RESUMEN

Cerebrospinal fluid leakage is a frequent complication after cranial and spinal surgery. To prevent this complication and seal the dura watertight, we developed Liqoseal, a dural sealant patch comprising a watertight polyesterurethane layer and an adhesive layer consisting of poly(DL-lactide-co-ε-caprolactone) copolymer and multiarmed N-hydroxylsuccinimide functionalized polyethylene glycol. We compared acute burst pressure and resistance to physiological conditions for 72 h of Liqoseal, Adherus, Duraseal, Tachosil, and Tisseel using computer-assisted models and fresh porcine dura. The mean acute burst pressure of Liqoseal in the cranial model (145 ± 39 mmHg) was higher than that of Adherus (87 ± 47 mmHg), Duraseal (51 ± 42 mmHg) and Tachosil (71 ± 16 mmHg). Under physiological conditions, cranial model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment during 72 hours as opposed to 3 of 3 for Adherus and Duraseal and 0 of 3 for Tachosil. The mean burst pressure of Liqoseal in the spinal model (233 ± 81 mmHg) was higher than that of Tachosil (123 ± 63 mmHg) and Tisseel (23 ± 16 mmHg). Under physiological conditions, spinal model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment for 72 hours as opposed to 3 of 3 for Adherus and 0 of 3 for Duraseal and Tachosil. This novel study showed that Liqoseal is capable of achieving a strong watertight seal over a dural defect in ex vivo models.


Asunto(s)
Procedimientos Neuroquirúrgicos/métodos , Animales , Encéfalo , Caproatos/química , Pérdida de Líquido Cefalorraquídeo/prevención & control , Combinación de Medicamentos , Duramadre/cirugía , Diseño de Equipo , Adhesivo de Tejido de Fibrina/química , Fibrinógeno/química , Humanos , Técnicas In Vitro , Lactonas/química , Poliésteres/química , Polietilenglicoles/química , Polímeros/química , Poliuretanos , Resinas Sintéticas , Cráneo , Médula Espinal/cirugía , Succinimidas/química , Porcinos , Trombina/química , Adhesivos Tisulares , Uretano/química
14.
J Mater Sci Mater Med ; 32(8): 87, 2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34319537

RESUMEN

A novel way was adopted to graft zinc oxide (ZnO) with urethane-modified dimethacrylate (UDMA) in order to utilize them as reinforcing agents in resin-based dental composites. Experimental novel composites were synthesized having UDMA-grafted and nongrafted ZnO, at a concentration of 0 wt.%, 5 wt.%, and 10 wt.%. The same concentrations of ZnO were also incorporated in Filtek Z250 XT (3 M ESPE, USA). The antibacterial behavior was evaluated against Streptococcus mutans by direct-contact test at one, three, and seven days of incubation. The compressive strength and Vickers microhardness were tested as per ISO 9917 and ISO/CD6507-1, respectively. For abrasive wear resistance, mass loss and roughness average after tooth-brushing cycles of 24,000 at custom-made tooth-brushing simulator were evaluated using noncontact profilometer. Data analysis was carried out using post hoc Tucky's test and nonparametric Kruskal-Wallis test. Direct contact test revealed that the antibacterial potential of novel and commercial composites was increased with an increase in the concentration of grafted ZnO as compared with nongrafted, whereby the potential was the highest at day seven. There was a significant decrease in compressive strength and Vickers hardness of commercial composites on addition of grafted ZnO while there was no significant difference in the strength of experimental novel composite. The abrasive wear of commercial and experimental composites was within clinical limits. Low-temperature flow-synthesis method was successfully employed to synthesize grafted and nongrafted ZnO. The UDMA-grafted ZnO can be incorporated into dental composites without decreasing their strength and these composites can be used to combat secondary caries.


Asunto(s)
Resinas Acrílicas/química , Antibacterianos/química , Resinas Compuestas/química , Metacrilatos/química , Poliuretanos/química , Uretano/química , Óxido de Zinc/química , Antibacterianos/farmacología , Fuerza Compresiva , Simulación por Computador , Ensayo de Materiales , Ácidos Polimetacrílicos , Unión Proteica , Reproducibilidad de los Resultados , Espectroscopía Infrarroja por Transformada de Fourier , Streptococcus mutans/metabolismo , Estrés Mecánico , Propiedades de Superficie , Temperatura , Termogravimetría , Difracción de Rayos X
15.
Sci Rep ; 11(1): 7638, 2021 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-33828183

RESUMEN

Filler particle functionalization with thiourethane oligomers has been shown to increase fracture toughness and decrease polymerization stress in dental composites, though the mechanism is poorly understood. The aim of this study was to systematically characterize the effect of the type of filler surface functionalization on the physicochemical properties of experimental resin composites containing fillers of different size and volume fraction. Barium glass fillers (1, 3 and 10 µm) were functionalized with 2 wt% thiourethane-silane (TU-Sil) synthesized de novo and characterized by thermogravimetric analysis. Fillers treated with 3-(Trimethoxysilyl)propyl methacrylate (MA-Sil) and with no surface treatment (No-Sil) served as controls. Fillers (50, 60 and 70 wt%) were incorporated into BisGMA-UDMA-TEGDMA (5:3:2) containing camphorquinone/ethyl-4-dimethylaminobenzoate (0.2/0.8 wt%) and 0.2 wt% di-tert-butyl hydroxytoluene. The functionalized particles were characterized by thermogravimetric analysis and a representative group was tagged with methacrylated rhodamine B and analyzed by confocal laser scanning microscopy. Polymerization kinetics were assessed by near-IR spectroscopy. Polymerization stress was tested in a cantilever system, and fracture toughness was assessed with single edge-notched beams. Fracture surfaces were characterized by SEM. Data were analyzed with ANOVA/Tukey's test (α = 0.05). The grafting of thiourethane oligomer onto the surface of the filler particles led to reductions in polymerization stress ranging between 41 and 54%, without affecting the viscosity of the composite. Fracture toughness increased on average by 35% for composites with the experimental fillers compared with the traditional methacrylate-silanized groups. SEM and confocal analyses demonstrate that the coverage of the filler surface was not homogeneous and varied with the size of the filler. The average silane layer for the 1 µm particle functionalized with the thiourethane was 206 nm, much thicker than reported for traditional silanes. In summary, this study systematically characterized the silane layer and established structure-property relationships for methacrylate and thiourethane silane-containing materials. The results demonstrate that significant stress reductions and fracture toughness increases are obtained by judiciously tailoring the organic-inorganic interface in dental composites.


Asunto(s)
Resinas Compuestas/química , Tiourea/química , Uretano/química , Compuestos de Bario/química , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales/métodos , Metacrilatos/química , Polietilenglicoles/química , Polimerizacion , Ácidos Polimetacrílicos/química , Silanos/química , Dióxido de Silicio/química , Espectrofotometría Infrarroja/métodos , Estrés Mecánico , Propiedades de Superficie
16.
Molecules ; 26(4)2021 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-33670043

RESUMEN

The aim of this study was to investigate and understand bacterial adhesion to different dental material surfaces like amalgam, Chromasit, an Co-Cr alloy, an IPS InLine ceramic, yttrium stabilized tetragonal polycrystalline zirconia (TPZ), a resin-based composite, an Au-Pt alloy, and a tooth. For all materials, the surface roughness was assessed by profilometry, the surface hydrophobicity was determined by tensiometry, and the zeta potential was measured by electrokinetic phenomena. The arithmetic average roughness was the lowest for the TPZ ceramic (Ra = 0.23 µm ± 0.02 µm), while the highest value was observed for the Au-Pt alloy (Ra = 0.356 µm ± 0.075 µm). The hydrophobicity was the lowest on the TPZ ceramic and the highest on the Co-Cr alloy. All measured streaming potentials were negative. The most important cause of tooth caries is the bacterium Streptococcus mutans, which was chosen for this study. The bacterial adhesion to all material surfaces was determined by scanning electron microscopy. We showed that the lowest bacterial extent was on the amalgam, whereas the greatest extent was on tooth surfaces. In general, measurements showed that surface properties like roughness, hydrophobicity and charge have a significant influence on bacterial adhesion extent. Therefore, dental material development should focus on improving surface characteristics to reduce the risk of secondary caries.


Asunto(s)
Aleaciones/química , Cerámica/química , Resinas Compuestas/química , Amalgama Dental/química , Metacrilatos/química , Streptococcus mutans/crecimiento & desarrollo , Uretano/química , Adhesión Bacteriana , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Tamaño de la Partícula , Propiedades de Superficie
17.
ACS Macro Lett ; 10(5): 616-622, 2021 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-35570768

RESUMEN

Sequence-encoded oligo(thioether urethane)s with two different coding monomers per backbone unit were prepared via a solid phase, two-step iterative protocol based on thiolactone chemistry. The first step of the synthetic cycle consists of the thiolactone ring opening with a primary amine, whereby the in situ released thiol is immediately reacted with an epoxide. In the second step, the thiolactone group is reinstalled to initiate the next cycle. This strategy allows to introduce two different coding monomers per synthetic cycle, rendering the resulting macromolecules especially attractive in the area of (macro)molecular data storage because of their increased data storage capacity. Subsequently, the efficiency of the herein reported synthesis route and the applicability of the dual-encoded sequence-defined macromolecules as a potential data storage platform have been demonstrated by unraveling the exact monomer order using tandem mass spectrometry techniques.


Asunto(s)
Compuestos de Sulfhidrilo , Uretano , Compuestos Epoxi , Resinas Epoxi , Almacenamiento y Recuperación de la Información , Sustancias Macromoleculares/química , Compuestos de Sulfhidrilo/química , Uretano/química
18.
Arch Gynecol Obstet ; 303(1): 181-188, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33146769

RESUMEN

PURPOSE: Postoperative seromas are a problem in the surgical treatment of breast cancer. The aim of the study was to evaluate whether the lysine-urethane-based tissue adhesive TissuGlu® without drainage is equal/ non-inferior to standard mastecomy with drainage. METHODS: The study was designed as a prospective, randomized, multicentre non-inferiority study comparing the use of TissuGlu® without drainage with standard wound care with a drain insertion in ablative breast procedures. The number of clinical interventions, quality of life and wound complications were followed-up for 90 days in both groups. RESULTS: Although the statistical power was not reached, twice as many clinical interventions were performed in the TissuGlu® group than in the drainage group, especially aspirations of clinically relevant seromas (p = 0.014). The TissuGlu® group produced overall less wound fluid, but developed a clinically relevant seroma (100% vs. 63%) which made an intervention necessary. Less hospitalisation time was observed in the TissuGlu® group, but the complication rate was higher. There was no significant difference in regards to postoperative pain. In summary the non-inferiority of TissuGlu® compared to standard drainage couldn't be reached. DISCUSSION: The present evaluation shows no advantage of the tissue adhesive TissuGlu® in terms of seroma formation and frequency of intervention compared to a standard drainage for mastectomies, but the shorter inpatient stay certainly has a positive effect on the quality of life.


Asunto(s)
Neoplasias de la Mama/cirugía , Mastectomía/métodos , Procedimientos de Cirugía Plástica/efectos adversos , Seroma/prevención & control , Cinta Quirúrgica , Técnicas de Sutura/efectos adversos , Adhesivos Tisulares/uso terapéutico , Adulto , Neoplasias de la Mama/patología , Drenaje/métodos , Femenino , Humanos , Lisina/química , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Calidad de Vida , Seroma/epidemiología , Seroma/etiología , Adherencias Tisulares , Adhesivos Tisulares/química , Resultado del Tratamiento , Uretano/química
19.
Food Chem ; 343: 128528, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33189477

RESUMEN

Ethyl carbamate (EC), a genotoxic and carcinogenic compound in soy sauce accumulated during thermal processes, has raised public health concern for its multipoint potential carcinogenic risk to human. In this work, based on the analysis of EC accumulation during thermal processes of soy sauce, ornithine and quercetin were added before thermal processes to reduce EC accumulation. A reduction rate of 23.7-63.8% in simulated solution was founded. Kinetic studies indicated that ornithine was a byproduct of alcoholysis reaction when EC formed, while quercetin could compete with the precursor ethanol and react with carbamyl compounds, which therefore preventedEC accumulation. A maximum of 47.2% decrease of EC in soy sauce was achieved, and no remarkable changes in volatile compounds profile and color of soy sauce were found. In conclusion, the addition of quercetin and ornithine before thermal processes may be preferable for the controlling of EC content in soy sauce.


Asunto(s)
Ornitina/química , Quercetina/química , Alimentos de Soja , Uretano/química , Carcinógenos/química , Etanol/química , Fermentación , Calidad de los Alimentos , Humanos , Concentración de Iones de Hidrógeno , Cinética , Alimentos de Soja/análisis , Uretano/análisis
20.
J Biomed Mater Res B Appl Biomater ; 109(5): 693-702, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33098257

RESUMEN

Surgical sutures are indispensable for a vast majority of operative procedures. An ideal suture is characterized by high tissue compliance without cutting into the mended tissue and optimal biocompatibility. Therefore, we assessed these mechanical and biological properties for novel elastic thermoplastic polyurethane (TPU) and cross-sectional modified "snowflake" sutures. Circular and "snowflake"-shaped TPU threads were manufactured and compared to similar surface modified polyvinylidene fluoride (PVDF) sutures. Regular PVDF sutures were used as the control group. Single-axis tensile test with and without gelatinous tissue surrogates were performed to evaluate the suture incision into the specimens. Biocompatibility was evaluated by subcutaneous implantation (n = 18) in rats for 7 and 21 days. Histology and immunohistology was conducted for assessment of the foreign body reaction. Regular and modified TPU threads showed a significant reduction of incision into the tissue surrogates compared to the control. Both TPU sutures and the modified PVDF sutures achieved comparable biocompatibility versus regular PVDF threads. Detailed histology revealed novel tissue integration into the notches of the surface modified sutures, we termed this newly shaped granuloma "intrafilamentous" granuloma. Elastic TPU threads showed a significant reduction of tissue surrogate incision and suture tension loss. Biocompatibility did not significantly differ from standard PVDF. Histology demonstrated tissue ingrowth following the surface modification of the suture referred to as "intrafilamentous" granuloma. Further in vivo studies are required to illuminate the exact potential of the new sutures to optimize intestinal anastomosis.


Asunto(s)
Materiales Biocompatibles/química , Elasticidad , Suturas , Uretano/química , Animales , Diseño de Equipo , Femenino , Polímeros de Fluorocarbono/química , Reacción a Cuerpo Extraño , Granuloma/patología , Técnicas In Vitro , Ensayo de Materiales , Polímeros/química , Polivinilos/química , Ratas , Ratas Sprague-Dawley , Temperatura , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...