Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.232
Filtrar
1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38870348

RESUMEN

AIMS: Patients with persistent atrial fibrillation (AF) experience 50% recurrence despite pulmonary vein isolation (PVI), and no consensus is established for secondary treatments. The aim of our i-STRATIFICATION study is to provide evidence for stratifying patients with AF recurrence after PVI to optimal pharmacological and ablation therapies, through in silico trials. METHODS AND RESULTS: A cohort of 800 virtual patients, with variability in atrial anatomy, electrophysiology, and tissue structure (low-voltage areas, LVAs), was developed and validated against clinical data from ionic currents to electrocardiogram. Virtual patients presenting AF post-PVI underwent 12 secondary treatments. Sustained AF developed in 522 virtual patients after PVI. Second ablation procedures involving left atrial ablation alone showed 55% efficacy, only succeeding in the small right atria (<60 mL). When additional cavo-tricuspid isthmus ablation was considered, Marshall-PLAN sufficed (66% efficacy) for the small left atria (<90 mL). For the bigger left atria, a more aggressive ablation approach was required, such as anterior mitral line (75% efficacy) or posterior wall isolation plus mitral isthmus ablation (77% efficacy). Virtual patients with LVAs greatly benefited from LVA ablation in the left and right atria (100% efficacy). Conversely, in the absence of LVAs, synergistic ablation and pharmacotherapy could terminate AF. In the absence of ablation, the patient's ionic current substrate modulated the response to antiarrhythmic drugs, being the inward currents critical for optimal stratification to amiodarone or vernakalant. CONCLUSION: In silico trials identify optimal strategies for AF treatment based on virtual patient characteristics, evidencing the power of human modelling and simulation as a clinical assisting tool.


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Humanos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Antiarrítmicos/uso terapéutico , Resultado del Tratamiento , Modelos Cardiovasculares , Simulación por Computador , Potenciales de Acción , Medición de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Masculino , Anisoles/uso terapéutico , Selección de Paciente , Femenino , Modelación Específica para el Paciente , Persona de Mediana Edad , Pirrolidinas/uso terapéutico , Electrocardiografía , Toma de Decisiones Clínicas
2.
BMC Cardiovasc Disord ; 24(1): 315, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38909188

RESUMEN

INTRODUCTION: Fibrosing mediastinitis (FM) is a rare disease characterized by excessive proliferation of fibrous tissue in the mediastinum and can cause bronchial stenosis, superior vena cava obstruction, pulmonary artery and vein stenosis, etc. CASE PRESENTATION: An aging patient with intermittent chest tightness and shortness of breath was diagnosed with FM associated pulmonary hypertension (FM-PH) by echocardiography and enhanced CT of the chest, and CT pulmonary artery (PA)/ pulmonary vein (PV) imaging revealed PA and PV stenosis. Selective angiography revealed complete occlusion of the right upper PV, and we performed endovascular intervention of the total occluded PV. After failure of the antegrade approach, the angiogram revealed well-developed collaterals of the occluded RSPV-V2b, so we chose to proceed via the retrograde approach. We successfully opened the occluded right upper PV and implanted a stent. CONCLUSIONS: This report may provide new management ideas for the interventional treatment of PV occlusion.


Asunto(s)
Venas Pulmonares , Stents , Humanos , Resultado del Tratamiento , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Enfermedad Crónica , Enfermedad Veno-Oclusiva Pulmonar/terapia , Enfermedad Veno-Oclusiva Pulmonar/diagnóstico por imagen , Enfermedad Veno-Oclusiva Pulmonar/fisiopatología , Enfermedad Veno-Oclusiva Pulmonar/etiología , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/terapia , Estenosis de Vena Pulmonar/fisiopatología , Estenosis de Vena Pulmonar/etiología , Mediastinitis/diagnóstico , Mediastinitis/terapia , Masculino , Flebografía , Angioplastia de Balón/instrumentación , Anciano , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/terapia , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/diagnóstico por imagen , Fibrosis , Circulación Colateral , Circulación Pulmonar , Femenino
3.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38758963

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. METHODS AND RESULTS: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. CONCLUSION: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Modelos Animales de Enfermedad , Venas Pulmonares , Animales , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/prevención & control , Fibrilación Atrial/diagnóstico , Porcinos , Ablación por Catéter/métodos , Apnea Obstructiva del Sueño/fisiopatología , Insuficiencia del Tratamiento , Frecuencia Cardíaca , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía
6.
Circ J ; 88(7): 1068-1077, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38811199

RESUMEN

BACKGROUND: It has not been fully elucidated which patients with persistent atrial fibrillation (PerAF) should undergo substrate ablation plus pulmonary vein isolation (PVI). This study aimed to identify PerAF patients who required substrate ablation using intraprocedural assessment of the baseline rhythm and the origin of atrial fibrillation (AF) triggers.Methods and Results: This was a post hoc subanalysis using extended data of the EARNEST-PVI trial, a prospective multicenter randomized trial comparing PVI-alone and PVI-plus (i.e., PVI with added catheter ablation) arms. We divided 492 patients into 4 groups according to baseline rhythm and the location of AF triggers before PVI: Group A (n=22), sinus rhythm with pulmonary vein (PV)-specific AF triggers (defined as reproducible AF initiation from PVs only); Group B (n=211), AF with PV-specific AF triggers; Group C (n=94), sinus rhythm with no PV-specific AF trigger; Group D (n=165), AF with no PV-specific AF trigger. Among the 4 groups, only in Group D (AF at baseline and no PV-specific AF triggers) was arrhythmia-free survival significantly lower in the PVI-alone than PVI-plus arm (P=0.032; hazard ratio 1.68; 95% confidence interval 1.04-2.70). CONCLUSIONS: Patients with sinus rhythm or PV-specific AF triggers did not receive any benefit from substrate ablation, whereas patients with AF and no PV-specific AF trigger benefited from substrate ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Humanos , Ablación por Catéter/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Estudios Prospectivos , Selección de Paciente , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca
7.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38767127

RESUMEN

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Asunto(s)
Criocirugía , Venas Pulmonares , Criocirugía/métodos , Criocirugía/instrumentación , Criocirugía/efectos adversos , Animales , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Porcinos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirugía , Modelos Anatómicos
8.
Int J Cardiovasc Imaging ; 40(6): 1363-1376, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38676848

RESUMEN

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.


Asunto(s)
Medios de Contraste , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Compuestos Organometálicos , Valor Predictivo de las Pruebas , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Medios de Contraste/administración & dosificación , Compuestos Organometálicos/administración & dosificación , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter , Electrocardiografía
9.
J Cardiovasc Electrophysiol ; 35(6): 1140-1149, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38561951

RESUMEN

INTRODUCTION: The presence of low-voltage zones (LVZs) in the left atrium (LA) is associated with the recurrence of atrial fibrillation (AF) following pulmonary vein isolation (PVI). However, there is variability and conflict in the data regarding predictors of LVZs as reported in previous studies. The objective of this study was to identify predictors for the presence of LVZs in a cohort of patients with persistent AF. METHODS: The study prospectively enrolled 439 patients with persistent AF who were scheduled for ablation. Voltage map of the LA was collected using a multipolar catheter. An LVZ was defined as an area of ≥3 cm2 exhibiting a peak-to-peak bipolar voltage of <0.5 mV. RESULTS: The mean age of the cohort was 65.3 ± 8.6 years and 26.4% were female. Additionally, 25.7% had significant LVZs, most frequently located in the anterior wall of the LA. Multivariable analysis identified the following independent predictors for LVZ: advanced age (OR [odds ratio] = 1.08, 95% CI [confidence interval] = 1.03-1.13, p = .002); female sex (OR = 4.83, 95% CI = 2.66-8.76, p < .001); coronary artery disease (CAD) (OR = 3.20, 95% CI = 1.32-7.77, p = .01) and enlarged LA diameter (OR = 1.10, 95% CI = 1.04-1.17, p = .001). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve for the final model was 0.829. CONCLUSION: Approximately 25% of the patients with persistent AF had LVZs. Advanced age, female sex, CAD, and a larger LA were independent predictors for LVZs with the model demonstrating a very good AUC for the ROC curve. These findings hold the potential to be used to tailor the ablation procedure for the individual patient.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Medición de Riesgo , Factores Sexuales , Factores de Tiempo , Factores de Edad
10.
J Cardiovasc Electrophysiol ; 35(6): 1150-1155, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38566579

RESUMEN

INTRODUCTION: Proactive esophageal cooling has been FDA cleared to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures. Data suggest that procedure times for RF pulmonary vein isolation (PVI) also decrease when proactive esophageal cooling is employed instead of luminal esophageal temperature (LET) monitoring. Reduced procedure times may allow increased electrophysiology (EP) lab throughput. We aimed to quantify the change in EP lab throughput of PVI cases after the introduction of proactive esophageal cooling. METHODS: EP lab throughput data were obtained from three EP groups. We then compared EP lab throughput over equal time frames at each site before (pre-adoption) and after (post-adoption) the adoption of proactive esophageal cooling. RESULTS: Over the time frame of the study, a total of 2498 PVIs were performed over a combined 74 months, with cooling adopted in September 2021, November 2021, and March 2022 at each respective site. In the pre-adoption time frame, 1026 PVIs were performed using a combination of LET monitoring with the addition of esophageal deviation when deemed necessary by the operator. In the post-adoption time frame, 1472 PVIs were performed using exclusively proactive esophageal cooling, representing a mean 43% increase in throughput (p < .0001), despite the loss of two operators during the post-adoption time frame. CONCLUSION: Adoption of proactive esophageal cooling during PVI ablation procedures is associated with a significant increase in EP lab throughput, even after a reduction in total number of operating physicians in the post-adoption group.


Asunto(s)
Ablación por Catéter , Esófago , Venas Pulmonares , Humanos , Esófago/cirugía , Ablación por Catéter/efectos adversos , Factores de Tiempo , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Resultado del Tratamiento , Hipotermia Inducida , Factores de Riesgo , Tempo Operativo , Técnicas Electrofisiológicas Cardíacas , Flujo de Trabajo , Estudios Retrospectivos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino
11.
Cardiovasc Pathol ; 71: 107640, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38604505

RESUMEN

Exertional dyspnea has been documented in US military personnel after deployment to Iraq and Afghanistan. We studied whether continued exertional dyspnea in this patient population is associated with pulmonary vascular disease (PVD). We performed detailed histomorphometry of pulmonary vasculature in 52 Veterans with biopsy-proven post-deployment respiratory syndrome (PDRS) and then recruited five of these same Veterans with continued exertional dyspnea to undergo a follow-up clinical evaluation, including symptom questionnaire, pulmonary function testing, surface echocardiography, and right heart catheterization (RHC). Morphometric evaluation of pulmonary arteries showed significantly increased intima and media thicknesses, along with collagen deposition (fibrosis), in Veterans with PDRS compared to non-diseased (ND) controls. In addition, pulmonary veins in PDRS showed increased intima and adventitia thicknesses with prominent collagen deposition compared to controls. Of the five Veterans involved in our clinical follow-up study, three had borderline or overt right ventricle (RV) enlargement by echocardiography and evidence of pulmonary hypertension (PH) on RHC. Together, our studies suggest that PVD with predominant venular fibrosis is common in PDRS and development of PH may explain exertional dyspnea and exercise limitation in some Veterans with PDRS.


Asunto(s)
Campaña Afgana 2001- , Hipertensión Pulmonar , Arteria Pulmonar , Humanos , Masculino , Arteria Pulmonar/patología , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/diagnóstico por imagen , Adulto , Hipertensión Pulmonar/patología , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/etiología , Persona de Mediana Edad , Femenino , Guerra de Irak 2003-2011 , Venas Pulmonares/patología , Venas Pulmonares/fisiopatología , Venas Pulmonares/diagnóstico por imagen , Disnea/etiología , Disnea/fisiopatología , Veteranos , Estudios de Casos y Controles , Salud de los Veteranos , Biopsia , Fibrosis
12.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556747

RESUMEN

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Asunto(s)
Fibrilación Atrial , Criocirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Potenciales de Acción , Frecuencia Cardíaca , Factores de Tiempo , Estudios Retrospectivos , Recurrencia , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología
14.
J Cardiovasc Electrophysiol ; 35(6): 1165-1173, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38571287

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Sedación Consciente , Frecuencia Cardíaca , Venas Pulmonares , Humanos , Masculino , Femenino , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Factores de Tiempo , Anciano , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Estudios Retrospectivos , Recurrencia , Resultado del Tratamiento , Catéteres Cardíacos , Supervivencia sin Progresión , Factores de Riesgo
15.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38682165

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Aprendizaje Automático , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Técnicas Electrofisiológicas Cardíacas/métodos , Resultado del Tratamiento , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Potenciales de Acción , Frecuencia Cardíaca , Algoritmos , Procesamiento de Señales Asistido por Computador
16.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38655693

RESUMEN

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Persona de Mediana Edad , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Estudios Prospectivos , Anciano , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción , Electrocardiografía Ambulatoria/instrumentación , Recurrencia , Catéteres Cardíacos , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Imagenología Tridimensional , Factores de Riesgo , Diseño de Equipo , Técnicas Electrofisiológicas Cardíacas
17.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38607938

RESUMEN

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Sistema de Registros , Reoperación , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Suiza/epidemiología , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos
18.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639381

RESUMEN

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Asunto(s)
Fibrilación Atrial , Estimulación Cardíaca Artificial , Ablación por Catéter , Atrios Cardíacos , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Estimulación Cardíaca Artificial/métodos , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Pericardio/cirugía , Pericardio/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca/fisiología
19.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38511484

RESUMEN

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Asunto(s)
Fibrilación Atrial , Criocirugía , Diseño de Equipo , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Criocirugía/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Factores de Tiempo , Catéteres Cardíacos , Tempo Operativo , Agujas , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Estudios Prospectivos , Frecuencia Cardíaca , Potenciales de Acción
20.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...