Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 826
Filtrar
1.
Sci Rep ; 14(1): 18671, 2024 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134580

RESUMEN

Ventilation systems of operating rooms (ORs) are significantly important in preventing postoperative wound infections that can cause morbidity and mortality after surgery in or out of the hospital. This study aims to identify the optimum overpressure for efficient operation while reducing the risk of surgical site infections (SSIs) based on the actual OR with the help of computational fluid dynamics. The species transport model, Lagrangian discrete phase model, and turbulent standard k- ε model are mainly used for the transient numerical study to improve the performance of the OR and reduce SSI cases. Four OR schemes were initially calculated for the best location of the patient on the surgical table. The results revealed that the modified position 90˚ is the best location with the minimum CO2 and BCP concentrations. The investigated operating room could host up to ten surgical members with the optimum overpressure of 5.89 Pa and 0.56 m/s of supply velocity under the standard cleanliness level. Modifying the supply surface area will enhance the performance of the operating room by providing a cleaner zone and maintaining the desired room pressure, even with a low airflow rate. This optimization scheme could guide practical applications in all positively pressurized operating rooms to address issues related to overpressure effects.


Asunto(s)
Quirófanos , Infección de la Herida Quirúrgica , Ventilación , Ventilación/métodos , Humanos , Infección de la Herida Quirúrgica/prevención & control , Presión , Modelos Teóricos , Hidrodinámica
2.
Ann Work Expo Health ; 68(7): 770-776, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38785326

RESUMEN

BACKGROUND: The public order and safety (POS) sector remains susceptible to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreaks, as workplace attendance is typically compulsory and close physical contact is often needed. Here, we report on a SARS-CoV-2 outbreak with an attack rate of 39% (9/23), which occurred between 19 and 29 June 2021 among a cohort of new POS recruits participating in a mandatory 18-week training programme in England. METHODS: The COVID-OUT (COVID-19 Outbreak investigation to Understand Transmission) study team undertook a multidisciplinary outbreak investigation, including viral surface sampling, workplace environmental assessment, participant viral and antibody testing, and questionnaires, at the two associated training facilities between 5 July and 24 August 2021. RESULTS: Environmental factors, such as ventilation, were deemed inadequate in some areas of the workplace, with carbon dioxide (CO2) levels exceeding 1,500 ppm on multiple occasions within naturally ventilated classrooms. Activities during safety training required close contact, with some necessitating physical contact, physical exertion, and shouting. Furthermore, most participants reported having physical contact with colleagues (67%) and more than one close work contact daily (97%). CONCLUSIONS: Our investigation suggests that site- and activity-specific factors likely contributed to the transmission risks within the POS trainee cohort. Potential interventions for mitigating SARS-CoV-2 transmission in this POS training context could include implementing regular rapid lateral flow testing, optimizing natural ventilation, using portable air cleaning devices in classrooms, and expanding use of well-fitted FFP2/FFP3 respirators during activities where prolonged close physical contact is required.


Asunto(s)
COVID-19 , Brotes de Enfermedades , SARS-CoV-2 , Lugar de Trabajo , Humanos , COVID-19/transmisión , COVID-19/epidemiología , Inglaterra/epidemiología , Brotes de Enfermedades/prevención & control , Masculino , Adulto , Femenino , Exposición Profesional/prevención & control , Ventilación/métodos
3.
Environ Health Perspect ; 132(5): 55001, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38728219

RESUMEN

BACKGROUND: In response to the COVID-19 pandemic, new evidence-based strategies have emerged for reducing transmission of respiratory infections through management of indoor air. OBJECTIVES: This paper reviews critical advances that could reduce the burden of disease from inhaled pathogens and describes challenges in their implementation. DISCUSSION: Proven strategies include assuring sufficient ventilation, air cleaning by filtration, and air disinfection by germicidal ultraviolet (UV) light. Layered intervention strategies are needed to maximize risk reduction. Case studies demonstrate how to implement these tools while also revealing barriers to implementation. Future needs include standards designed with infection resilience and equity in mind, buildings optimized for infection resilience among other drivers, new approaches and technologies to improve ventilation, scientific consensus on the amount of ventilation needed to achieve a desired level of risk, methods for evaluating new air-cleaning technologies, studies of their long-term health effects, workforce training on ventilation systems, easier access to federal funds, demonstration projects in schools, and communication with the public about the importance of indoor air quality and actions people can take to improve it. https://doi.org/10.1289/EHP13878.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , SARS-CoV-2 , Ventilación , COVID-19/transmisión , COVID-19/prevención & control , Humanos , Contaminación del Aire Interior/prevención & control , Ventilación/métodos , Microbiología del Aire , Desinfección/métodos , Infecciones del Sistema Respiratorio/prevención & control , Infecciones del Sistema Respiratorio/transmisión
5.
Br J Anaesth ; 133(1): 19-23, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38677948

RESUMEN

The COVID-19 pandemic has transformed our understanding of aerosol transmissible disease and the measures required to minimise transmission. Anaesthesia providers are often in close proximity to patients and other hospital staff for prolonged periods while working in operating and procedure rooms. Although enhanced ventilation provides some protection from aerosol transmissible disease in these work areas, close proximity and long duration of exposure have the opposite effect. Surgical masks provide only minimal additional protection. Surgical patients are also at risk from viral and bacterial aerosols. Despite having recently experienced the most significant pandemic in 100 yr, we continue to lack adequate understanding of the true risks encountered from aerosol transmissible diseases in the operating room, and the best course of action to protect patients and healthcare workers from them in the future. Nevertheless, hospitals can take specific actions now by providing respirators for routine use, encouraging staff to utilise respirators routinely, establishing triggers for situations that require respirator use, educating staff concerning the prevention of aerosol transmissible diseases, and providing portable air purifiers for perioperative spaces with low levels of ventilation.


Asunto(s)
Aerosoles , COVID-19 , Quirófanos , Humanos , COVID-19/prevención & control , COVID-19/transmisión , Control de Infecciones/métodos , Exposición Profesional/prevención & control , Microbiología del Aire , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Dispositivos de Protección Respiratoria , Ventilación/métodos , Máscaras
6.
J Occup Environ Hyg ; 21(6): 379-388, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38652919

RESUMEN

Residents of long-term care facilities are particularly vulnerable to communicable diseases. Low-cost interventions to increase air exchange rates (AERs) may be useful in reducing the transmission of airborne communicable diseases between long-term care residents and staff. In this study, carbon dioxide gas was used as a tracer to evaluate the AER associated with the implementation of low-cost ventilation interventions. Under baseline conditions with the room's door closed, the mean AER was 0.67 ACH; while baseline conditions with the door open had a significantly higher mean AER of 3.87 ACH (p < 0.001). Subsequently opening a window with the door open increased mean AER by 1.49 ACH (p = 0.012) and adding a fan in the window further increased mean AER by 1.87 ACH (p < 0.001). Regression analyses indicated that the flow rate of air entering through the window, both passively and through the use of a fan, was significantly associated with an increase in AER (p < 0.001). These results indicate that low-cost interventions that pull outside air into resident rooms were effective in improving the air exchange rates in these facilities. While implementation of these interventions is dependent on facility rules and isolation requirements of residents with airborne communicable diseases, these interventions remain viable options for long-term care facilities to improve resident room ventilation without requiring costly ventilation system upgrades.


Asunto(s)
Cuidados a Largo Plazo , Ventilación , Ventilación/métodos , Humanos , Cuidados a Largo Plazo/economía , Contaminación del Aire Interior/prevención & control , Casas de Salud , Dióxido de Carbono/análisis
7.
J Hosp Infect ; 148: 51-57, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38537748

RESUMEN

BACKGROUND: Surgical site infection (SSI) in the form of postoperative deep sternal wound infection (DSWI) after cardiac surgery is a rare, but potentially fatal, complication. In addressing this, the focus is on preventive measures, as most risk factors for SSI are not controllable. Therefore, operating rooms are equipped with heating, ventilation and air conditioning (HVAC) systems to prevent airborne contamination of the wound, either through turbulent mixed air flow (TMA) or unidirectional air flow (UDAF). AIM: To investigate if the risk for SSI after cardiac surgery was decreased after changing from TMA to UDAF. METHODS: This observational retrospective single-centre cohort study collected data from 1288 patients who underwent open heart surgery over 2 years. During the two study periods, institutional SSI preventive measures remained the same, with the exception of the type of HVAC system that was used. FINDINGS: Using multi-variable logistic regression analysis that considered confounding factors (diabetes, obesity, duration of surgery, and re-operation), the hypothesis that TMA is an independent risk factor for SSI was rejected (odds ratio 0.9, 95% confidence interval 0.4-1.8; P>0.05). It was not possible to demonstrate the preventive effect of UDAF on the incidence of SSI in patients undergoing open heart surgery when compared with TMA. CONCLUSION: Based on these results, the use of UDAF in open heart surgery should be weighed against its low cost-effectiveness and negative environmental impact due to high electricity consumption. Reducing energy overuse by utilizing TMA for cardiac surgery can diminish the carbon footprint of operating rooms, and their contribution to climate-related health hazards.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Infección de la Herida Quirúrgica , Ventilación , Humanos , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/epidemiología , Estudios Retrospectivos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Ventilación/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Quirófanos , Anciano de 80 o más Años , Aire Acondicionado/efectos adversos , Movimientos del Aire , Incidencia , Control de Infecciones/métodos , Factores de Riesgo , Adulto
8.
Sci Rep ; 14(1): 6843, 2024 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-38514758

RESUMEN

The impact of mechanical ventilation on airborne diseases is not completely known. The recent pandemic of COVID-19 clearly showed that additional investigations are necessary. The use of computational tools is an advantage that needs to be included in the study of designing safe places. The current study focused on a hospital lift where two subjects were included: a healthy passenger and an infected one. The elevator was modelled with a fan placed on the middle of the ceiling and racks for supplying air at the bottom of the lateral wall. Three ventilation strategies were evaluated: a without ventilation case, an upwards-blowing exhausting fan case and a downwards-blowing fan case. Five seconds after the elevator journey began, the infected person coughed. For the risk assessment, the CO2 concentration, droplet removal performance and dispersion were examined and compared among the three cases. The results revealed some discrepancies in the selection of an optimal ventilation strategy. Depending on the evaluated parameter, downward-ventilation fan or no ventilation strategy could be the most appropriate approach.


Asunto(s)
COVID-19 , Dióxido de Carbono , Humanos , Respiración , Hospitales , Tos , Ventilación/métodos
9.
Sci Total Environ ; 926: 171939, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38527543

RESUMEN

Source localization is significant for mitigating indoor air pollution and safeguarding the well-being and safety of occupants. While most study focuses on mechanical ventilation and static sources, this study explores the less-explored domain of locating time-varying sources in naturally ventilated spaces. We have developed an innovative 3D localization system that adjusts to varying heights, significantly enhancing capabilities beyond traditional fixed-height 2D systems. To ensure consistency in experimental conditions, we conducted comparative analyses of 2D and 3D methods, using a swinging fan to simulate natural ventilation. Our findings reveal a substantial disparity in performance: the 2D method had a success rate below 46.7% in cases of height mismatches, while our 3D methods consistently achieved success rates above 66.7%, demonstrating their superior effectiveness in complex environments. Furthermore, we validated the 3D strategies in real naturally ventilated settings, confirming their wider applicability. This research extends the scope of indoor source localization and offers valuable insights and strategies for more effective pollution control.


Asunto(s)
Contaminación del Aire Interior , Robótica , Olfato , Ventilación/métodos , Contaminación del Aire Interior/análisis
10.
Ann Work Expo Health ; 68(4): 387-396, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38527239

RESUMEN

Over the past 15 years, there have been numerous fatalities related to working with animal slurry. Working with cattle slurry releases toxic gases, in particular, hydrogen sulphide (H2S), which can cause acute central nervous system toxicity, breathing difficulties, and death if exposed to high concentrations. Real-time measurements of H2S gas were taken over distance and time, during the stirring of cattle slurry on farms. Gas was measured at eight slurry stores with differing typical configurations of indoor or outdoor stores and with or without slatted flooring. Highest H2S gas levels were measured from indoor stores under slatted floors, and generally at positions closest to the stirrer or the point of maximum stirring, with levels decreasing with distance from source. Most of the data indicate H2S gas levels increase very rapidly after stirring starts, and mostly decline to baseline levels within 30 min post start of stirring. There were, however, circumstances where gas levels remained high and only started to decline once the stirrer had stopped. H2S gas levels at all farms, at all positions measured were consistently below 10 ppm within 30 min of the stirrer being stopped. The current data highlight areas of the farm and ways of working that have the potential for workers and others to be at risk of exposure to toxic slurry gases. The area should be left to ventilate naturally for at least 30 min after the stirrer has been stopped before re-entering buildings. Influencing the design of stirring equipment and future slurry stores would likely reduce the risk of worker exposure to slurry gases.


Asunto(s)
Sulfuro de Hidrógeno , Exposición Profesional , Sulfuro de Hidrógeno/análisis , Animales , Bovinos , Exposición Profesional/análisis , Humanos , Contaminantes Ocupacionales del Aire/análisis , Crianza de Animales Domésticos/métodos , Estiércol/análisis , Granjas , Monitoreo del Ambiente/métodos , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Ventilación/métodos
11.
J Hosp Infect ; 147: 115-122, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38423130

RESUMEN

BACKGROUND: The operating room (OR) department is one of the most energy-intensive departments of a hospital. The majority of ORs in the Netherlands have an air-handling installation with an ultra-clean ventilation system. However, not all surgeries require an ultra-clean OR. AIM: To determine the effect of reducing the air change rate on the ventilation effectiveness in ultra-clean ORs. METHODS: Lower air volume ventilation effectiveness (VELv) of conventional ventilation (CV), controlled dilution ventilation (cDV), temperature-controlled airflow (TcAF) and unidirectional airflow (UDAF) systems were evaluated within a 4 × 4 m measuring grid of 1 × 1 m. The VELv was defined as the recovery degree (RD), cleanliness recovery rate (CRR) and air change effectiveness (ACE). FINDINGS: The CV, cDVLv and TcAFLv ventilation systems showed a comparable mixing character in all areas (A, B and AB) when reducing the air change rate to 20/h. Ventilation effectiveness decreased when the air change rate was reduced, with the exception of the ACE. At all points for the UDAF-2Lv and at the centre point (C3) of the TcAFLv, higher RD10Lv and CRRLv were measured when compared with the other examined ventilation systems. CONCLUSIONS: The ventilation effectiveness decreased when an ultra-clean OR with an ultra-clean ventilation air-supply system was switched to an air change rate of 20/h. Reducing the air change rate in the OR from an ultra-clean OR to a generic OR will reduce the recovery degree (RD10) by a factor of 10-100 and the local air change rate (CRR) by between 42% and 81%.


Asunto(s)
Quirófanos , Ventilación , Ventilación/métodos , Humanos , Países Bajos , Aire Acondicionado
12.
Environ Sci Technol ; 58(10): 4704-4715, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38326946

RESUMEN

Ozone reaction with human surfaces is an important source of ultrafine particles indoors. However, 1-20 nm particles generated from ozone-human chemistry, which mark the first step of particle formation and growth, remain understudied. Ventilation and indoor air movement could have important implications for these processes. Therefore, in a controlled-climate chamber, we measured ultrafine particles initiated from ozone-human chemistry and their dependence on the air change rate (ACR, 0.5, 1.5, and 3 h-1) and operation of mixing fans (on and off). Concurrently, we measured volatile organic compounds (VOCs) and explored the correlation between particles and gas-phase products. At 25-30 ppb ozone levels, humans generated 0.2-7.7 × 1012 of 1-3 nm, 0-7.2 × 1012 of 3-10 nm, and 0-1.3 × 1012 of 10-20 nm particles per person per hour depending on the ACR and mixing fan operation. Size-dependent particle growth and formation rates increased with higher ACR. The operation of mixing fans suppressed the particle formation and growth, owing to enhanced surface deposition of the newly formed particles and their precursors. Correlation analyses revealed complex interactions between the particles and VOCs initiated by ozone-human chemistry. The results imply that ventilation and indoor air movement may have a more significant influence on particle dynamics and fate relative to indoor chemistry.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Ozono , Compuestos Orgánicos Volátiles , Humanos , Tamaño de la Partícula , Ozono/análisis , Ventilación/métodos , Material Particulado/análisis , Compuestos Orgánicos Volátiles/análisis , Contaminación del Aire Interior/análisis , Contaminantes Atmosféricos/análisis
13.
Environ Sci Pollut Res Int ; 31(9): 14135-14155, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38270763

RESUMEN

COVID-19 and other respiratory infectious viruses are highly contagious, and patients need to be treated in negative pressure wards. At present, many negative pressure wards use independent air conditioning equipment, but independent air conditioning equipment has problems such as indoor air circulation flow, condensate water accumulation, and improper filter maintenance, which increase the risk of infection for healthcare workers and patients. The radiation air conditioning system relies on the radiation ceiling to control the indoor temperature and uses new air to control the indoor humidity and air quality. The problems caused by the use of independent air conditioning equipment should be avoided. This paper studies the thermal comfort, contaminant distribution characteristics, contaminant removal efficiency, and accessibility of supply air in a negative pressure ward with a radiation air conditioning system under three airflow patterns. In addition, the negative pressure ward was divided into 12 areas, and the infection probability of healthcare workers in different areas was analyzed. The results show that the application of radiation air conditioning systems in negative pressure wards can ensure the thermal comfort of patients. Stratum ventilation and ceiling-attached jets have similar effects in protecting healthcare workers; both can effectively reduce the contaminant concentrations and the risk of infection of healthcare workers. Ceiling-attached jets decreases the contaminant concentrations by 10.73%, increases the contaminant removal efficiency by 12.50%, and decreases the infection probability of healthcare workers staying indoors for 10 min by 23.18%, compared with downward ventilation.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Humanos , Contaminación del Aire Interior/análisis , Aisladores de Pacientes , Aire Acondicionado , Temperatura , Ventilación/métodos
14.
J Hosp Infect ; 141: 33-40, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37640266

RESUMEN

Guidelines for heating, ventilation, and air-conditioning systems have been developed for different settings. However, there is a lack of up-to-date evidence providing concrete recommendations for the heating, ventilation, and air-conditioning systems of an isolation room, which is essential to appropriately guide infection control policies. To highlight the guidelines for heating, ventilation, and air-conditioning systems in isolation rooms to inform relevant stakeholders and policymakers. A systematic search was performed based on Joanna Briggs Methodology using five databases (CINAHL, Embase, Joanna Briggs Institute, Medline, and Web of Science) and websites. Eight articles published by government departments were included in this review. Most studies recommended controlled airflow without recirculation, 12 air changes per hour, high-efficiency particulate air filtrate to exhaust contaminated air from the airborne isolation room, humidity ≤60%, and temperature in the range of 18-30 °C. This review provides further evidence that there is a need for interdisciplinary collaborative research to quantify the optimum range for heating, ventilation, and air conditioning system parameters, considering door types, anterooms, and bed management, to effectively reduce the transmission of infection in isolation rooms.


Asunto(s)
Contaminación del Aire Interior , Calefacción , Humanos , Ventilación/métodos , Aire Acondicionado , Fenómenos Fisiológicos Respiratorios , Atención a la Salud
15.
Sci Total Environ ; 899: 165454, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37467991

RESUMEN

Upper-room ultraviolet germicidal irradiation (UVGI) system is recently in the limelight as a potentially effective method to mitigate the risk of airborne virus infection in indoor environments. However, few studies quantitatively evaluated the relationship between ventilation effectiveness and virus disinfection performance of a UVGI system. The objective of this study is to investigate the effects of ventilation strategy on detailed airflow distributions and UVGI disinfection performance in an occupied classroom. Three-dimensional computational fluid dynamics (CFD) simulations were performed for representative cooling, heating, and ventilation scenarios. The results show that when the ventilation rate is 1.1 h-1 (the minimum ventilation rate based on ASHRAE 62.1), enhancing indoor air circulation with the mixing fan notably improves the UVGI disinfection performance, especially for cooling with displacement ventilation and all-air-heating conditions. However, increasing indoor air mixing yields negligible effect on the disinfection performance for forced-convection cooling condition. The results also reveal that regardless of indoor thermal condition, disinfection effectiveness of a UVGI system increases as ventilation effectiveness is close to unity. Moreover, when the room average air speed is >0.1 m/s, upper-room UVGI system could yield about 90% disinfection effect for the aerosol size of 1 µm-10 µm. The findings of this study imply that upper-room UVGI systems in indoor environments (i.e., classrooms, hospitals) should be designed considering ventilation strategy and occupancy conditions, especially for occupied buildings with insufficient air mixing throughout the space.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior , Ventilación/métodos , Rayos Ultravioleta , Desinfección/métodos , Respiración , Contaminación del Aire Interior/prevención & control , Contaminación del Aire Interior/análisis
16.
Environ Pollut ; 335: 122239, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37482333

RESUMEN

Tunnel construction often relies on drilling and blasting. High dust pollution is one of the primary problems of drilling and blasting construction. The level of secondary blown dust pollution caused by ventilation matches that of dust pollution caused by drilling construction. In this study, a critical flow model and blown dust rate model for deposited dust were established via force analysis, which was validated against the test data. The research results showed that the characteristic airflow velocity for blowing dust particles with a 100 µm diameter reached approximately 0.42 m/s for tunnel diameter is 10 m, and the ventilation Re values under smooth and rough conditions were 2.3 × 105 and 1.4 × 105, respectively. Furthermore, when ventilation Re reached 4 × 105, the blown dust pollution rate caused by ventilation under smooth conditions was approximately 1.8 × 10-2 kg/s. If dust particle size is more or less the critical dust particle size, the characteristic airflow velocity was increased. Moreover, the optimal velocity at which the deposited dust does not flow or move during tunnel construction was related to the tunnel size and roughness. For the smooth tunnel with a diameter of 10 m, the optimal ventilation velocity was 3.5 m/s. When the tunnel roughness was increased from 0.005 to 0.5 m, the optimal ventilation velocity decreased from 3.3 to 1.6 m/s. The deposited dust critical flow model and blown dust pollution rate model established in this study provide a sound theoretical basis for selecting the optimal velocity of tunnel ventilation and recognizing the risks of secondary blown dust pollution due to ventilation.


Asunto(s)
Polvo , Exposición Profesional , Polvo/análisis , Ventilación/métodos , Tamaño de la Partícula , Exposición Profesional/análisis , Respiración
17.
Environ Pollut ; 333: 122025, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37336354

RESUMEN

To prevent respiratory infections between patients and medical workers, the transmission risk of airborne pollutants in hospital wards must be mitigated. The ventilation modes, which are regarded as an important strategy to minimize the infection risk, are challenging to be systematically designed. Studies have considered the effect of ventilation openings (inlets/outlets) or infected source locations on the airflow distribution, pollutant removal, and infection risk mitigation. However, the relationship (such as relative distance) between ventilation openings and infected sources is critical because it affects the direct exhaust of exhaled pollutants, which has not been thoroughly studied. To explore pollutant removal and infection prevention in wards, different ventilation modes (with varying ventilation openings) and infected patient locations must be jointly considered. This study investigated displacement ventilation (DV), downward ventilation (DWV), and stratum ventilation (SV) with 4, 6, and 10 scenarios of ventilation openings, respectively. The optimal ventilation mode and relative distance between outlets and infected patients were analyzed based on the simulated pollutant concentration fields and the evaluated infection risk. The pollutant removal effect and infection risk mitigation of SV in the ward were largely improved by 75% and 59% compared with DV and DWV, respectively. The average infection risk was reduced below 7% when a non-dimensional relative distance (a ratio of the actual distance to the cubic root of the ward volume) was less than 0.25 between outlets and infected patient. This study can serve as a guide for the systematic ventilation system design in hospitals during the epidemic.


Asunto(s)
Filtros de Aire , Infección Hospitalaria , Contaminantes Ambientales , Humanos , Infección Hospitalaria/epidemiología , Infección Hospitalaria/prevención & control , Respiración , Hospitales , Ventilación/métodos
18.
Environ Int ; 176: 107944, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37216835

RESUMEN

This study monitored indoor environmental data in 144 classrooms in 31 schools in the Midwestern United States for two consecutive days every fall, winter, and spring during a two-year period; 3,105 pupils attended classrooms where the measurements were conducted. All classrooms were ventilated with mechanical systems that had recirculation; there were no operable exterior windows or doors. The daily absence rate at the student level and demographic data at the classroom level were collected. The overall mean ventilation rate, using outdoor air, was 5.5 L/s per person (the corresponding mean carbon dioxide concentrations were < 2,000 ppm), and the mean indoor PM2.5 was 3.6 µg/m3. The annual illness-related absence rate at the classroom level was extracted from the student-level absence data and regressed on measured indoor environmental parameters. Significant associations were found. Every 1 L/s per person increase in ventilation rate was associated with a 5.59 decrease in days with absences per year. This corresponds to a 0.15% increase in the annual daily attendance rate. Every additional 1 µg/m3 of indoor PM2.5 was associated with a 7.37 increase in days with absences per year. This corresponds to a 0.19% decrease in the annual daily attendance rate. No other relationships were significant. Present results agree with the previously demonstrated benefits of reduced absence rates when classroom ventilation is improved and provide additional evidence on the potential benefits of reducing indoor inhalable particles. Overall, reduced absence rates are expected to provide socioeconomic benefits and benefits for academic achievements, while higher ventilation rates and reduced particle levels will also contribute to reduced health risks, including those related to airborne respiratory pathogens.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Humanos , Contaminación del Aire Interior/análisis , Respiración , Instituciones Académicas , Ventilación/métodos , Medio Oeste de Estados Unidos , Material Particulado/análisis , Contaminantes Atmosféricos/análisis , Monitoreo del Ambiente/métodos
19.
Sci Total Environ ; 884: 163805, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37142023

RESUMEN

A four-week-long field intervention experiment was conducted in twenty-nine bedrooms with extract ventilation systems and air inlet vents. During the first week no interventions took place. In the three weeks that followed, each participant slept for one week under a low, moderate, and high ventilation rate condition in a balanced order. These conditions were established by covertly altering the fan speed of the exhaust ventilation system without changing other settings. Participants were not informed when or even whether the changes to bedroom ventilation would be executed. The bedroom environmental quality was monitored continuously and sleep quality was monitored using wrist-worn trackers. Tests of cognitive performance were conducted in the evening and morning. In twelve bedrooms where clear differences between the three ventilation conditions occurred, as indicated by the measured CO2 concentrations, participants had significantly less deep sleep, more light sleep and more awakenings at lower ventilation rate conditions. In twenty-three bedrooms where a clear difference in ventilation rate between the high and low ventilation conditions was observed, as confirmed by the measured CO2 concentrations, the deep sleep was significantly shorter in the low ventilation rate condition. No differences in cognitive performance between conditions were observed. At lower ventilation rate conditions, the concentrations of CO2 increased, as did the relative humidity, while bedroom temperatures remained unchanged. The present results, which were obtained in actual bedrooms, confirm the findings in previous studies of a positive effect of increased ventilation on sleep quality. Further studies with larger populations and better control of bedroom conditions, particularly ventilation, are required.


Asunto(s)
Contaminación del Aire Interior , Calidad del Sueño , Humanos , Método Simple Ciego , Dióxido de Carbono/análisis , Sueño , Temperatura , Ventilación/métodos , Contaminación del Aire Interior/prevención & control , Contaminación del Aire Interior/análisis
20.
Artículo en Inglés | MEDLINE | ID: mdl-37107857

RESUMEN

Indoor air quality (IAQ) influences the health and intellectual productivity of occupants. This paper summarizes studies investigating the relationship between intellectual productivity and IAQ with varying ventilation rates. We conducted a meta-analysis of five studies, with a total of 3679 participants, and performed subgroup analyses (arithmetic, verbal comprehension, and cognitive ability) based on the type of academic performance. The task performance speed and error rate were evaluated to measure intellectual productivity. The effect size of each study was evaluated using the standardized mean difference (SMD). In addition, we calculated a dose-response relationship between ventilation rate and intellectual productivity. The results show that the task performance speed improved, SMD: 0.18 (95% CI: 0.10-0.26), and the error rate decreased, SMD: -0.05 (95% CI: -0.11-0.00), with an increase in ventilation rate. Converting the intervention effect size on the SMD into the natural units of the outcome measure, our analyses show significant improvements in the task performance speed: 13.7% (95% CI: 6.2-20.5%) and 3.5% (95% CI: 0.9-6.1%) in terms of arithmetic tasks and cognitive ability, respectively. The error rate decreased by -16.1% (95% CI: -30.8-0%) in arithmetic tasks. These results suggest that adequate ventilation is necessary for good performance.


Asunto(s)
Contaminación del Aire Interior , Humanos , Contaminación del Aire Interior/análisis , Matemática , Ventilación/métodos , Análisis y Desempeño de Tareas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...