Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27.448
Filtrar
1.
J Acoust Soc Am ; 155(5): 3101-3117, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722101

RESUMEN

Cochlear implant (CI) users often report being unsatisfied by music listening through their hearing device. Vibrotactile stimulation could help alleviate those challenges. Previous research has shown that musical stimuli was given higher preference ratings by normal-hearing listeners when concurrent vibrotactile stimulation was congruent in intensity and timing with the corresponding auditory signal compared to incongruent. However, it is not known whether this is also the case for CI users. Therefore, in this experiment, we presented 18 CI users and 24 normal-hearing listeners with five melodies and five different audio-to-tactile maps. Each map varied the congruence between the audio and tactile signals related to intensity, fundamental frequency, and timing. Participants were asked to rate the maps from zero to 100, based on preference. It was shown that almost all normal-hearing listeners, as well as a subset of the CI users, preferred tactile stimulation, which was congruent with the audio in intensity and timing. However, many CI users had no difference in preference between timing aligned and timing unaligned stimuli. The results provide evidence that vibrotactile music enjoyment enhancement could be a solution for some CI users; however, more research is needed to understand which CI users can benefit from it most.


Asunto(s)
Estimulación Acústica , Percepción Auditiva , Implantes Cocleares , Música , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Anciano , Percepción Auditiva/fisiología , Adulto Joven , Prioridad del Paciente , Implantación Coclear/instrumentación , Percepción del Tacto/fisiología , Vibración , Tacto
2.
ACS Appl Mater Interfaces ; 16(19): 25160-25168, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38701174

RESUMEN

Fiber has been considered as an ideal material for virus insulation due to the readily available electrostatic adsorption. However, restricted by the electrostatic attenuation and filtration performance decline, their long-lasting applications are unable to satisfy the requirements of medical protective equipment for major medical and health emergencies such as global epidemics, which results in both a waste of resources and environmental pollution. We overcame these issues by constructing a fiber-in-tube structure, achieving the robust reusability of fibrous membranes. Core fibers within the hollow could form generators with tube walls of shell fibers to provide persistent, renewable static electricity via piezoelectricity and triboelectricity. The PM0.3 insulation efficiency achieved 98% even after 72 h of humidity and heat aging, through beating and acoustic waves, which is greatly improved compared with that of traditional nonwoven fabric (∼10% insulation). A mask spun with our fiber also has a low breathing resistance (differential pressure <24.4 Pa/cm2). We offer an approach to enrich multifunctional fiber for developing electrifiable filters, which make the fiber-in-tube filtration membrane able to durably maintain a higher level of protective performance to reduce the replacement and provide a new train of thought for the preparation of other high-performance protective products.


Asunto(s)
Filtración , Electricidad Estática , Vibración , Filtración/instrumentación , Sonido , SARS-CoV-2/aislamiento & purificación , Textiles , Humanos
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124377, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38701580

RESUMEN

Tryptophan (Trp) residue provides characteristic vibrational markers to the middle wavenumber spectral region of the Raman spectra recorded from peptides and proteins. In this report, we were particularly interested in eight Trp Raman markers, referred to as Wi (i = 1,…,8). All responsible for pronounced Raman lines, these markers originate from indole moiety, a bicyclic conjugated segment involved in the Trp structure. Numerous investigations have previously attempted to relate the variations observed in the spectral features of these markers to the environmental changes of Trp residues. To emphasize the most important points we can mention (i) the variations in the Raman profile of W4 (∼1360 cm-1) and W5 (∼1340 cm-1), frequently observed as a doublet with variable intensity ratio. These two markers were thought to result from a Fermi-resonance effect between certain planar and nonplanar modes; (ii) the changes observed in the wavenumbers and relative intensities of W4, W7 (∼880 cm-1) and W8 (∼760 cm-1) were supposed to be related to the accessibility of Trp to surrounding water molecules; and (iii) the wavenumber fluctuations of W3 (∼1550 cm-1), taken as a Trp side chain orientational marker. However, some ambiguities still exist regarding the interpretation of these markers, needing further clarification. Herein, upon a joint experimental and theoretical analysis based on a multiconformational approach, attention was paid to the relationships between structural and vibrational features of three indole-containing compounds with increasing structural complexity, i.e., skatole (3-methylindole), tryptophan, and tripeptide Gly-Trp-Gly. This study clearly shows that the existing assignments given to certain Trp Raman markers should be reconsidered, especially those based on the Fermi-resonance origin of W4-W5 (∼1360-1340 cm-1) doublet, as well as the purely environmental dependence of W7 and W8 markers.


Asunto(s)
Espectrometría Raman , Triptófano , Vibración , Triptófano/química , Triptófano/análisis , Espectrometría Raman/métodos , Conformación Molecular , Indoles/química
4.
Biointerphases ; 19(3)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38738942

RESUMEN

Planar supported lipid bilayers (PSLBs) are an ideal model for the study of lipid membrane structures and dynamics when using sum-frequency vibrational spectroscopy (SFVS). In this paper, we describe the construction of asymmetric PSLBs and the basic SFVS theory needed to understand and make measurements on these membranes. Several examples are presented, including the determination of phospholipid orientation and measuring phospholipid transmembrane translocation (flip-flop).


Asunto(s)
Membrana Dobles de Lípidos , Análisis Espectral , Membrana Dobles de Lípidos/química , Análisis Espectral/métodos , Vibración , Fosfolípidos/química , Lípidos de la Membrana/química
5.
Sci Rep ; 14(1): 10774, 2024 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-38729999

RESUMEN

Muscular dystrophies (MD) are a group of genetic neuromuscular disorders that cause progressive weakness and loss of muscles over time, influencing 1 in 3500-5000 children worldwide. New and exciting treatment options have led to a critical need for a clinical post-marketing surveillance tool to confirm the efficacy and safety of these treatments after individuals receive them in a commercial setting. For MDs, functional gait assessment is a common approach to evaluate the efficacy of the treatments because muscle weakness is reflected in individuals' walking patterns. However, there is little incentive for the family to continue to travel for such assessments due to the lack of access to specialty centers. While various existing sensing devices, such as cameras, force plates, and wearables can assess gait at home, they are limited by privacy concerns, area of coverage, and discomfort in carrying devices, which is not practical for long-term, continuous monitoring in daily settings. In this study, we introduce a novel functional gait assessment system using ambient floor vibrations, which is non-invasive and scalable, requiring only low-cost and sparsely deployed geophone sensors attached to the floor surface, suitable for in-home usage. Our system captures floor vibrations generated by footsteps from patients while they walk around and analyzes such vibrations to extract essential gait health information. To enhance interpretability and reliability under various sensing scenarios, we translate the signal patterns of floor vibration to pathological gait patterns related to MD, and develop a hierarchical learning algorithm that aggregates insights from individual footsteps to estimate a person's overall gait performance. When evaluated through real-world experiments with 36 subjects (including 15 patients with MD), our floor vibration sensing system achieves a 94.8% accuracy in predicting functional gait stages for patients with MD. Our approach enables accurate, accessible, and scalable functional gait assessment, bringing MD progressive tracking into real life.


Asunto(s)
Marcha , Distrofias Musculares , Vibración , Humanos , Niño , Marcha/fisiología , Distrofias Musculares/fisiopatología , Distrofias Musculares/diagnóstico , Distrofias Musculares/terapia , Masculino , Femenino , Análisis de la Marcha/métodos , Análisis de la Marcha/instrumentación , Adolescente
6.
PLoS One ; 19(5): e0298263, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38722883

RESUMEN

The design of tuned mass damper (TMD) parameters is influenced by the soil-structure-TMD coupling system; thus, it is important to consider the soil-structure interaction (SSI) for the vibration control effect of the TMD. Recently, the acquisition of TMD parameters considering soil-structure interactions has only remained at the theoretical stage, lacking relevant experimental verification. Traditional TMD face the problems of occupying a large building space, increasing construction costs, and non-replaceable components. In this study, an assembled wall-type damping TMD was designed. By comparing the dynamic response of the uncontrolled and controlled structures equipped with the newly assembled wall-type damping TMD in the shaking table test on a soft soil foundation, we analyzed whether the SSI effect was considered in the TMD design parameters on the damping effect of the newly assembled wall-type tuned mass damper. The TMD parameters optimized using the artificial intelligence algorithm were verified experimentally. The results indicated that the traditional TMD design parameters were discordant because the SSI effect was not considered. The SSI effect in the soil effectively reduces the dynamic response of the superstructure. By considering the SSI effect and improving the multi-population genetic algorithm, a wall-type damping TMD with optimized parameters can achieve a good damping effect.


Asunto(s)
Algoritmos , Suelo , Suelo/química , Terremotos , Vibración
7.
Commun Biol ; 7(1): 600, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762693

RESUMEN

Pending questions regarding cochlear amplification and tuning are hinged upon the organ of Corti (OoC) active mechanics: how outer hair cells modulate OoC vibrations. Our knowledge regarding OoC mechanics has advanced over the past decade thanks to the application of tomographic vibrometry. However, recent data from live cochlea experiments often led to diverging interpretations due to complicated interaction between passive and active responses, lack of image resolution in vibrometry, and ambiguous measurement angles. We present motion measurements and analyses of the OoC sub-components at the close-to-true cross-section, measured from acutely excised gerbil cochleae. Specifically, we focused on the vibrating patterns of the reticular lamina, the outer pillar cell, and the basilar membrane because they form a structural frame encasing active outer hair cells. For passive transmission, the OoC frame serves as a rigid truss. In contrast, motile outer hair cells exploit their frame structures to deflect the upper compartment of the OoC while minimally disturbing its bottom side (basilar membrane). Such asymmetric OoC vibrations due to outer hair cell motility explain how recent observations deviate from the classical cochlear amplification theory.


Asunto(s)
Gerbillinae , Células Ciliadas Auditivas Externas , Órgano Espiral , Vibración , Animales , Gerbillinae/fisiología , Células Ciliadas Auditivas Externas/fisiología , Órgano Espiral/fisiología , Órgano Espiral/citología , Cóclea/fisiología , Cóclea/citología , Membrana Basilar/fisiología
8.
Exp Brain Res ; 242(6): 1481-1493, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38702470

RESUMEN

The anterior (DA) and posterior parts of the deltoid (DP) show alternating contraction during shoulder flexion and extension movements. It is expected that an inhibitory spinal reflex between the DA and DP exists. In this study, spinal reflexes between the DA and DP were examined in healthy human subjects using post-stimulus time histogram (PSTH) and electromyogram averaging (EMG-A). Electrical conditioning stimulation was delivered to the axillary nerve branch that innervates the DA (DA nerve) and DP (DP nerve) with the intensity below the motor threshold. In the PSTH study, the stimulation to the DA and DP nerves inhibited (decrease in the firing probability) 31 of 54 DA motor units and 31 of 51 DP motor units. The inhibition was not provoked by cutaneous stimulation. The central synaptic delay of the inhibition between the DA and DP nerves was 1.5 ± 0.5 ms and 1.4 ± 0.4 ms (mean ± SD) longer than those of the homonymous facilitation of the DA and DP, respectively. In the EMG-A study, conditioning stimulation to the DA and DP nerves inhibited the rectified and averaged EMG of the DP and DA, respectively. The inhibition diminished with tonic vibration stimulation to the DA and DP and recovered 20-30 min after vibration removal. These findings suggest that oligo(di or tri)-synaptic inhibition mediated by group Ia afferents between the DA and DP exists in humans.


Asunto(s)
Músculo Deltoides , Estimulación Eléctrica , Electromiografía , Inhibición Neural , Humanos , Masculino , Adulto , Músculo Deltoides/fisiología , Músculo Deltoides/inervación , Femenino , Inhibición Neural/fisiología , Adulto Joven , Vibración , Vías Aferentes/fisiología
10.
J Mech Behav Biomed Mater ; 154: 106537, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588632

RESUMEN

The Advanced System for Implant Stability Testing (ASIST) is a device currently being developed to noninvasively measure implant stability by estimating the mechanical stiffness of the bone-implant interface, which is reported as the ASIST Stability Coefficient (ASC). This study's purpose was to determine whether changes in density, bonding, and drilling technique affect the measured vibration of a dental implant, and whether they can be quantified as a change in the estimated BII stiffness. Stability was also measured using RFA, insertion torque (IT) and the pullout test. Bone-level tapered implants (4.1 mm diameter, 10 mm length) were inserted in polyurethane foam as an artificial bone substitute. Samples were prepared using different bone densities (20, 30, 40 PCF), drilling sequences, and superglue to simulate a bonded implant. Measurements were compared across groups at a significance level of 0.05. The ASC was able to indicate changes in each factor as a change in the interfacial stiffness. IT and pullout force values also showed comparable increases. Furthermore, the relative difference in ISQ values between experimental groups was considerably smaller than the ASC. While future work should be done using biological bone and in-vivo systems, the results of this in-vitro study suggest that modelling of the implant system with a vibration-based approach may provide a noninvasive method of assessing the mechanical stability of the implant.


Asunto(s)
Sustitutos de Huesos , Implantes Dentales , Vibración , Huesos , Densidad Ósea , Torque
11.
Sci Rep ; 14(1): 8475, 2024 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-38605084

RESUMEN

Prolonged local vibration (LV) can induce neurophysiological adaptations thought to be related to long-term potentiation or depression. Yet, how changes in intracortical excitability may be involved remains to be further investigated as previous studies reported equivocal results. We therefore investigated the effects of 30 min of LV applied to the right flexor carpi radialis muscle (FCR) on both short-interval intracortical inhibition (SICI) and intracortical facilitation (ICF). SICI and ICF were measured through transcranial magnetic stimulation before and immediately after 30 min of FCR LV (vibration condition) or 30 min of rest (control condition). Measurements were performed during a low-intensity contraction (n = 17) or at rest (n = 7). No significant SICI nor ICF modulations were observed, whether measured during isometric contractions or at rest (p = 0.2). Yet, we observed an increase in inter-individual variability for post measurements after LV. In conclusion, while intracortical excitability was not significantly modulated after LV, increased inter-variability observed after LV may suggest the possibility of divergent responses to prolonged LV exposure.


Asunto(s)
Corteza Motora , Vibración , Electromiografía/métodos , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Estimulación Magnética Transcraneal/métodos , Inhibición Neural/fisiología
12.
Sensors (Basel) ; 24(7)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38610233

RESUMEN

Increased incidence of traumatic brain injury (TBI) imposes a growing need to understand the pathology of brain trauma. A correlation between the incidence of multiple brain traumas and rates of behavioural and cognitive deficiencies has been identified amongst people that experienced multiple TBI events. Mechanically, repetitive TBIs may affect brain tissue in a similar way to cyclic loading. Hence, the potential susceptibility of brain tissue to mechanical fatigue is of interest. Although temporal changes in ovine brain tissue viscoelasticity and biological fatigue of other tissues such as tendons and arteries have been investigated, no methodology currently exists to cyclically load ex vivo brain tissue. A novel rheology-based approach found a consistent, initial stiffening response of the brain tissue before a notable softening when subjected to a subsequential cyclic rotational shear. History dependence of the mechanical properties of brain tissue indicates susceptibility to mechanical fatigue. Results from this investigation increase understanding of the fatigue properties of brain tissue and could be used to strengthen therapy and prevention of TBI, or computational models of repetitive head injuries.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Vibración , Ovinos , Animales , Humanos , Modalidades de Fisioterapia , Encéfalo , Reología
13.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38610445

RESUMEN

Cardiovascular diseases pose a long-term risk to human health. This study focuses on the rich-spectrum mechanical vibrations generated during cardiac activity. By combining Fourier series theory, we propose a multi-frequency vibration model for the heart, decomposing cardiac vibration into frequency bands and establishing a systematic interpretation for detecting multi-frequency cardiac vibrations. Based on this, we develop a small multi-frequency vibration sensor module based on flexible polyvinylidene fluoride (PVDF) films, which is capable of synchronously collecting ultra-low-frequency seismocardiography (ULF-SCG), seismocardiography (SCG), and phonocardiography (PCG) signals with high sensitivity. Comparative experiments validate the sensor's performance and we further develop an algorithm framework for feature extraction based on 1D-CNN models, achieving continuous recognition of multiple vibration features. Testing shows that the recognition coefficient of determination (R2), mean absolute error (MAE), and root mean square error (RMSE) of the 8 features are 0.95, 2.18 ms, and 4.89 ms, respectively, with an average prediction speed of 60.18 us/point, meeting the re-quirements for online monitoring while ensuring accuracy in extracting multiple feature points. Finally, integrating the vibration model, sensor, and feature extraction algorithm, we propose a dynamic monitoring system for multi-frequency cardiac vibration, which can be applied to portable monitoring devices for daily dynamic cardiac monitoring, providing a new approach for the early diagnosis and prevention of cardiovascular diseases.


Asunto(s)
Enfermedades Cardiovasculares , Vibración , Humanos , Corazón , Algoritmos , Fonocardiografía
14.
PLoS One ; 19(4): e0298535, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38598472

RESUMEN

Elephants have a unique auditory system that is larger than any other terrestrial mammal. To quantify the impact of larger middle ear (ME) structures, we measured 3D ossicular motion and ME sound transmission in cadaveric temporal bones from both African and Asian elephants in response to air-conducted (AC) tonal pressure stimuli presented in the ear canal (PEC). Results were compared to similar measurements in humans. Velocities of the umbo (VU) and stapes (VST) were measured using a 3D laser Doppler vibrometer in the 7-13,000 Hz frequency range, stapes velocity serving as a measure of energy entering the cochlea-a proxy for hearing sensitivity. Below the elephant ME resonance frequency of about 300 Hz, the magnitude of VU/PEC was an order of magnitude greater than in human, and the magnitude of VST/PEC was 5x greater. Phase of VST/PEC above ME resonance indicated that the group delay in elephant was approximately double that of human, which may be related to the unexpectedly high magnitudes at high frequencies. A boost in sound transmission across the incus long process and stapes near 9 kHz was also observed. We discuss factors that contribute to differences in sound transmission between these two large mammals.


Asunto(s)
Elefantes , Animales , Humanos , Oído Medio/fisiología , Sonido , Estribo/fisiología , Audición/fisiología , Vibración
15.
J Biomech ; 168: 112111, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38657433

RESUMEN

Snoring is common in children and is associated with many adverse consequences. One must study the relationships between pharyngeal morphology and snoring physics to understand snoring progression. Although some model studies have provided fluid-structure interaction dynamic descriptions for the correlation between airway size and snoring physics, the descriptions still need to be further investigated in patient-specific airway models. Fluid-structure interaction studies using patient-specific airway structures complement the above model studies. Based on reported cephalometric measurement methods, this study quantified and preset the size of the palatopharynx airway in a patient-specific airway and investigated how the palatopharynx size affects the pharyngeal airflow fluctuation, soft palate vibration, and glossopharynx vibration with the help of a verified FSI method. The results showed that the stenosis anterior airway of the soft palate increased airway resistance and airway resistance fluctuations, which can lead to increased sleep effort and frequent snoring. Widening of the anterior airway can reduce airflow resistance and avoid obstructing the anterior airway by the soft palate vibration. The pharyngeal airflow resistance, mouth inflow proportion, and soft palate apex displacement have components at the same frequencies in all airway models, and the glossopharynx vibration and instantaneous inflow rate have components at the same frequencies, too. The mechanism of this same frequency fluctuation phenomenon can be explained by the fluid-structure interaction dynamics of an ideal coupled model consisting of a flexible plate model and a collapsible tube model. The results of this study demonstrate the potential of FSI in studying snoring physics and clarify to some degree the mechanism of airway morphology affecting airway vibration physics.


Asunto(s)
Paladar Blando , Faringe , Ronquido , Vibración , Humanos , Faringe/fisiología , Ronquido/fisiopatología , Niño , Paladar Blando/fisiología , Paladar Blando/fisiopatología , Masculino , Resistencia de las Vías Respiratorias/fisiología , Modelos Biológicos
16.
Bioorg Med Chem Lett ; 106: 129757, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38636718

RESUMEN

9-cyanopyronin is a promising scaffold that exploits resonance Raman enhancement to enable sensitive, highly multiplexed biological imaging. Here, we developed cyano-Hydrol Green (CN-HG) derivatives as resonance Raman scaffolds to expand the color palette of 9-cyanopyronins. CN-HG derivatives exhibit sufficiently long wavelength absorption to produce strong resonance Raman enhancement for near-infrared (NIR) excitation, and their nitrile peaks are shifted to a lower frequency than those of 9-cyanopyronins. The fluorescence of CN-HG derivatives is strongly quenched due to the lack of the 10th atom, unlike pyronin derivatives, and this enabled us to detect spontaneous Raman spectra with high signal-to-noise ratios. CN-HG derivatives are powerful candidates for high performance vibrational imaging.


Asunto(s)
Espectrometría Raman , Estructura Molecular , Vibración , Nitrilos/química , Nitrilos/síntesis química
17.
J Chem Inf Model ; 64(9): 3912-3922, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38648614

RESUMEN

In constructing finite models of enzyme active sites for quantum-chemical calculations, atoms at the periphery of the model must be constrained to prevent unphysical rearrangements during geometry relaxation. A simple fixed-atom or "coordinate-lock" approach is commonly employed but leads to undesirable artifacts in the form of small imaginary frequencies. These preclude evaluation of finite-temperature free-energy corrections, limiting thermochemical calculations to enthalpies only. Full-dimensional vibrational frequency calculations are possible by replacing the fixed-atom constraints with harmonic confining potentials. Here, we compare that approach to an alternative strategy in which fixed-atom contributions to the Hessian are simply omitted. While the latter strategy does eliminate imaginary frequencies, it tends to underestimate both the zero-point energy and the vibrational entropy while introducing artificial rigidity. Harmonic confining potentials eliminate imaginary frequencies and provide a flexible means to construct active-site models that can be used in unconstrained geometry relaxations, affording better convergence of reaction energies and barrier heights with respect to the model size, as compared to models with fixed-atom constraints.


Asunto(s)
Dominio Catalítico , Teoría Cuántica , Vibración , Modelos Moleculares , Enzimas/química , Enzimas/metabolismo , Modelos Químicos , Termodinámica
18.
Proc Inst Mech Eng H ; 238(5): 508-519, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38562010

RESUMEN

Emergency ambulances play a vital role in medical rescue and patient transportation, but their transit can impact patient health due to vehicle dynamic forces and vibrations. This study evaluates patient transport conditions on a stretcher subjected to vertical vibration excitation from road unevenness. Using an eight-degree-of-freedom numerical model, we analyze the construction parameters of a medical stretcher's support and vehicle suspension. Actual experimental data from an emergency vehicle were utilized to assess the vibration conditions experienced by both the stretcher and the ambulance floor. The model is adjusted based on measurements, specifically targeting the main vibration modes. The investigation involves determining temporal responses for vertical accelerations and characterizing vibration modal parameters under various transportation conditions. Notably, several system natural frequencies fall within the range of human body frequencies, making them susceptible to mechanical excitation, particularly in the human neck, abdomen, and spine. A sensitivity analysis underscores the influence of medical stretcher support structure parameters on patient comfort. Increasing support stiffness, which alters the stretcher's natural frequency, and damping coefficient reduce vibration propagation between the vehicle and the patient. Additionally, the research predicts the model's dynamic behavior on roads with low-quality pavement, indicating vibrational amplitudes that could potentially be discomforting and unhealthy for individuals. The study illustrates a vibration exposure period on a class E road, revealing that transportation longer than 25 min may cause damage to patient health.


Asunto(s)
Ambulancias , Vibración , Humanos , Transporte de Pacientes , Camillas , Modelos Teóricos
19.
Work ; 78(1): 153-165, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640185

RESUMEN

BACKGROUND: Occupational foot-transmitted vibration (FTV) exposure is common in industries like mining, construction, and agriculture, often leading to acute and chronic injuries. Vibration assessments require technical expertise and equipment which can be costly for employers to perform. Alternatively, researchers have observed that self-reported discomfort can be used as an effective indicator of injury risk. OBJECTIVE: This study aimed to investigate the effect of standing FTV exposure on self-reported ratings of discomfort, and whether these subjective ratings differed by body area and exposure frequency. METHODS: Participants (n = 30) were randomly exposed to standing FTV at six frequencies (25, 30, 35, 40, 45, and 50 Hz) for 20-45 seconds. Following each exposure, participants rated discomfort on a scale of 0-9 in four body areas: head and neck (HN), upper body (UB), lower body (LB), and total body. RESULTS: Results indicated that participants experienced the most discomfort in the LB at higher frequencies (p < 0.001), consistent with the resonance of foot structures. The HN discomfort tended to decrease as the exposure frequency increased, although not statistically significant (p > 0.0167). The UB discomfort remained relatively low across all frequencies. CONCLUSIONS: The study suggests a potential connection between resonant frequencies and discomfort, potentially indicating injury risk. Although self-reported discomfort is insufficient for directly assessing injury risk from FTV, it provides a simple method for monitoring potential musculoskeletal risks related to vibration exposure at resonant frequencies. While professional vibration assessment remains necessary, self-reported discomfort may act as an early indicated of vibration-induced injuries, aiding in implementing mitigation strategies.


Asunto(s)
Pie , Autoinforme , Vibración , Humanos , Vibración/efectos adversos , Masculino , Femenino , Adulto , Pie/fisiología , Posición de Pie , Exposición Profesional/efectos adversos
20.
Appl Ergon ; 118: 104264, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38565009

RESUMEN

Whole-body vibration (WBV) is prevalent in labour-related activities and can have adverse effects on the health and performance of the individuals exposed. However, evidence regarding the extent to which human functionality is affected following occupational WBV exposure has not been collated. The current systematic review sought to synthesize existing literature and assess the strength and direction of evidence regarding the acute after-effects of occupational WBV exposure on cognition, visual function, postural stability, and motor control. We conducted a comprehensive search of AMED, CINAHL, MEDLINE, PubMED, Psychology and Behavioural Sciences Collection, SPORTDiscus, APA PsychInfo, Cochrane Library, EMBASE, HMIC, Global Health, ProQuest Central, Scopus, Web of Science, and the US National Technical Information Service on April 26, 2023. Studies that quantified vibration exposure and measured acute changes in cognition, visual function, postural stability, and motor control from baseline to post-vibration were considered without date restriction. Out of the 2663 studies identified, 32 were eligible for inclusion. Based on the Risk of Bias in Non-Randomized Studies of Exposure (ROBINS-E) tool, the studies demonstrated low (66%), moderate (25%) and high risk of bias (9%). The findings indicate that after exposure to WBV, postural stability either deteriorates or remains unchanged. Inconsistent effects of WBV on cognition were reported, while visual function and motor control showed no pronounced changes following WBV. This might be attributed to assessment limitations such as learning effects in neuropsychological and motor tasks, and non-functional measures of vision employed. There was a lack of consistency in the characterization of vibration exposure and the assessment of associated effects on functional performance. Current evidence is therefore insufficient to provide definitive guidance for updating occupational health and safety regulations regarding WBV. However, this review highlights the potential for WBV to jeopardize post-exposure human performance and, consequently, safety. The completion of the review was supported by a UKRI EPSRC training grant. The review has been registered on PROSPERO (ref CRD42023391075).


Asunto(s)
Cognición , Exposición Profesional , Equilibrio Postural , Vibración , Humanos , Exposición Profesional/efectos adversos , Equilibrio Postural/fisiología , Vibración/efectos adversos , Visión Ocular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA