1.
Appl Radiat Isot ; 50(6): 989-94, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10355102

RESUMO

This paper focuses on the evaluation of the k0 method of instrumental neutron activation analysis in biological materials. The method has been applied in multielement analysis of human hair standard reference materials from IAEA, No. 085, No. 086 and from NIES (National Institute for Environmental Sciences) No. 5. Hair samples from people resident in different parts of Malaysia, in addition to a sample from Japan, were analyzed. In addition, human kidney stones from members of the Malaysian population have been analyzed for minor and trace elements. More than 25 elements have been determined. The samples were irradiated in the rotary rack (Lazy Susan) at the TRIGA Mark II reactor of the Malaysian Institute for Nuclear Technology and Research (MINT). The accuracy of the method was ascertained by analysis of other reference materials, including 1573 tomato leaves and 1572 citrus leaves. In this method the deviation of the 1/E1+ alpha epithermal neutron flux distribution from the 1/E law (P/T ratio) for true coincidence effects of the gamma-ray cascade and the HPGe detector efficiency were determined and corrected for.


Assuntos
Cabelo/química , Cálculos Renais/química , Oligoelementos/análise , Citrus/química , Humanos , Japão , Solanum lycopersicum/química , Malásia , Análise de Ativação de Nêutrons/métodos , Folhas de Planta , Padrões de Referência
2.
Biol Trace Elem Res ; 71-72: 365-76, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10676512

RESUMO

Medicinal herb preparations prescribed for specific treatment purposes were purchased from markets and were analyzed by instrumental neutron activation analysis with k0 standardization. Then, 500-700 mg of each sample was pelletized under a pressure of six tones and irradiated together with monitors for alpha and neutron flux ratio determinations for about 6 h in a thermal flux of 2.29 x 10(12) n/cm2/s. The accuracy of the method was established by analyzing standard reference materials. Twenty-nine elements, Ag, As, Au, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Mn, Mo, Na, Rb, Sb, Sc, Se, Sm, Sr, Th, U, Yb, and Zn, were measured in all the samples, and Hg was detected in some samples, with good accuracy and reproducibility. The concentration of elements determined was found to vary depending on the composition of the herbs used. Although the trend linking the element of the medicinal plants to its curative abilities could not be clearly determined, this study showed that the toxic elements found in the samples were below the levels prescribed by health regulations. Nevertheless, such data are important to understand the pharmacological action and the exact mechanisms of action and formation of active constituents for each medicinal plant and to decide the dosage of the herbs used in the final formulation.


Assuntos
Análise de Ativação de Nêutrons/métodos , Fitoterapia , Análise de Ativação de Nêutrons/normas , Reprodutibilidade dos Testes