Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39057860

RESUMO

We report on the use of 2D Ruddlesden-Popper (RP) perovskites as optoelectronic materials in building-integrated applications, addressing the challenge of balancing transparency, photoluminescence, and stability. With the addition of polyvinylpyrrolidone (PVP), the 2D RP films exhibit superior transparency compared to their 3D counterparts with an average visible transmittance (AVT) greater than 50% and photoluminescence stability under continuous illumination and 85 °C heat for up to 100 h as bare, unencapsulated films. Structural investigations show a stress relaxation in the 3D perovskite films after degradation from thermal aging that is not observed in the 2D RP films, which retain their phase after thermal and light aging. We also demonstrate ultrasmooth, wide-bandgap 2D Dion-Jacobson (DJ) films with PVP incorporation up to 2.95 eV, an AVT above 70%, and roughnesses of ~2 nm. These findings contribute to the development of next-generation solar materials, paving the way for their integration into built structures.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37903284

RESUMO

Challenges to upscaling metal halide perovskites (MHPs) include mechanical film stresses that accelerate degradation, dominate at the module scale, and can lead to delamination or fracture. In this work, we demonstrate open-air blade coating of single-step coated perovskite as a scalable method to control residual film stress after processing and introduce beneficial compression in the thin film with the use of polymer additives such as gellan gum and corn starch. The optoelectronic properties of MHP films with compression are improved with higher photoluminescence yields. MHP film stability is significantly improved under compression, under humidity, heat, and thermal cycling. By measuring the evolution of film stresses, we demonstrate for the first time that stress relaxation occurs in MHP films with tensile stress that correlates with film degradation. This discovery of a new mechanism underpinning MHP degradation shows that film stress can be used as a parameter to screen MHP devices and modules for quality control before deployment as a design for reliability criterion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...