Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 12(11)2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36354505

RESUMO

Early diagnosis is highly crucial for life-saving and transmission management of tuberculosis (TB). Despite the low sensitivity and time-consuming issues, TB antigen detection still relies on conventional smear microscopy and culture techniques. To address this limitation, we report the development of the first amperometric dual aptasensor for the simultaneous detection of Mycobacterium tuberculosis secreted antigens CFP10 and MPT64 for better diagnosis and control of TB. The developed sensor was based on the aptamers-antibodies sandwich assay and detected by chronoamperometry through the electrocatalytic reaction between peroxidase-conjugated antibodies, H2O2, and hydroquinone. The CFP10 and MPT64 aptamers were immobilized via carbodiimide covalent chemistry over the disposable dual screen-printed carbon electrodes modified with a 4-carboxyphenyl diazonium salt. Under optimized conditions, the aptasensor achieved a detection limit of 1.68 ng mL-1 and 1.82 ng mL-1 for CFP10 and MPT64 antigens, respectively. The developed assay requires a small sample amount (5 µL) and can be easily performed within 2.5 h. Finally, the dual aptasensor was successfully applied to clinical sputum samples with the obtained diagnostic sensitivity (n = 24) and specificity (n = 13) of 100%, respectively, suggesting the readiness of the developed assay to be used for TB clinical application.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Mycobacterium tuberculosis , Tuberculose , Humanos , Carbono , Peróxido de Hidrogênio , Tuberculose/diagnóstico , Tuberculose/microbiologia , Eletrodos , Diagnóstico Precoce , Biomarcadores , Técnicas Biossensoriais/métodos
2.
Nanomaterials (Basel) ; 12(15)2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35893519

RESUMO

Curbing tuberculosis (TB) requires a combination of good strategies, including a proper prevention measure, diagnosis, and treatment. This study proposes an improvised tuberculosis diagnosis based on an amperometry approach for the sensitive detection of MPT64 antigen in clinical samples. An MPT64 aptamer specific to the target antigen was covalently attached to the carboxyphenyl diazonium-functionalized carbon electrode via carbodiimide chemistry. The electrochemical detection assay was adapted from a sandwich assay format to trap the antigen between the immobilized aptamer and horseradish peroxidase (HRP) tagged polyclonal anti-MPT64 antibody. The amperometric current was measured from the catalytic reaction response between HRP, hydrogen peroxide, and hydroquinone, which is used as an electron mediator. From the analysis, the detection limit in the measurement buffer was 1.11 ng mL-1. Additionally, the developed aptasensor exhibited a linear relationship between the current signal and the MPT64 antigen-spiked serum concentration ranging from 10 to 150 ng mL-1 with a 1.38 ng mL-1 detection limit. Finally, an evaluation using the clinical sputum samples from both TB (+) and TB (-) individuals revealed a sensitivity and specificity of 88% and 100%, respectively. Based on the analysis, the developed aptasensor was found to be simple in its fabrication, sensitive, and allowed for the efficient detection and diagnosis of TB in sputum samples.

3.
Mikrochim Acta ; 188(1): 20, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404779

RESUMO

An early detection of Mycobacterium tuberculosis is very important to reduce the number of fatal cases and allow for fast recovery. However, the interpretation of the result from smear microscopy requires skilled personnel due to the propensity of the method to produce false-negative results. In this work, a portable, rapid, and simple sandwich-type immunosensor reader has been developed that is able to detect the presence of M. tuberculosis in sputum samples. By using sandwich-type immunosensor, an anti-CFP10-ESAT6 antibody was immobilized onto the graphene/polyaniline (GP/PANI)-modified gold screen-printed electrode. After incubation with the target CFP10-ESAT6 antigen, the iron/gold magnetic nanoparticles (Fe3O4/Au MNPs) conjugated with anti-CFP10-ESAT6 antibody were used to complete the sandwich format. Differential pulse voltammetry (DPV) technique was used to detect the CFP10-ESAT6 antigen at the potential range of 0.0-1.0 V. The detection time is less than 2 h. Under optimal condition, CFP10-ESAT6 antigen was detected in a linear range from 10 to 500 ng mL-1 with a limit of detection at 1.5 ng mL-1. The method developed from this process was then integrated into a portable reader. The performance of the sensor was investigated and compared with the standard methods (culture and smear microscopy). It provides a good correlation (100% sensitivity and 91.7% specificity) with both methods of detection for M. tuberculosis in sputum samples henceforth, demonstrating the potential of the device as a more practical screening tool.Graphical abstract.


Assuntos
Proteínas de Bactérias/análise , Nanopartículas de Magnetita/química , Mycobacterium tuberculosis/química , Proteínas Recombinantes de Fusão/análise , Escarro/química , Tuberculose/diagnóstico por imagem , Técnicas Eletroquímicas/métodos , Ouro/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Molecules ; 24(17)2019 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-31470528

RESUMO

This work presents a simple green synthesis of gold nanoparticles (AuNPs) by using an aqueous extract of Etlingera elatior (torch ginger). The metabolites present in E. elatior, including sugars, proteins, polyphenols, and flavonoids, were known to play important roles in reducing metal ions and supporting the subsequent stability of nanoparticles. The present work aimed to investigate the ability of the E. elatior extract to synthesise AuNPs via the reduction of gold (III) chloride hydrate and characterise the properties of the nanoparticles produced. The antioxidant properties of the E. elatior extract were evaluated by analysing the total phenolic and total flavonoid contents. To ascertain the formation of AuNPs, the synthesised particles were characterised using the ultraviolet-visible (UV-Vis) spectroscopy, Fourier transform infrared (FTIR) spectroscopy, high-resolution transmission electron microscopy (HRTEM), energy-dispersive X-ray (EDX) microscopy, and dynamic light scattering (DLS) measurement. The properties of the green synthesised AuNPs were shown to be comparable to the AuNPs produced using a conventional reducing agent, sodium citrate. The UV-Vis measured the surface plasmon resonance of the AuNPs, and a band centered at 529 nm was obtained. The FTIR results proved that the extract contained the O-H functional group that is responsible for capping the nanoparticles. The HRTEM images showed that the green synthesized AuNPs were of various shapes and the average of the nanoparticles' hydrodynamic diameter was 31.5 ± 0.5 nm. Meanwhile, the zeta potential of -32.0 ± 0.4 mV indicates the high stability and negative charge of the AuNPs. We further successfully demonstrated that using the green synthesised AuNPs as the nanocomposite to modify the working surface of screen-printed carbon electrode (SPCE/Cs/AuNPs) enhanced the rate of electron transfer and provided a sensitive platform for the detection of Cu(II) ions.


Assuntos
Técnicas Biossensoriais/instrumentação , Cobre/isolamento & purificação , Técnicas Eletroquímicas/instrumentação , Ouro/química , Nanopartículas Metálicas/química , Zingiberaceae/química , Antioxidantes/química , Antioxidantes/isolamento & purificação , Cátions Bivalentes , Flavonoides/química , Química Verde , Nanopartículas Metálicas/ultraestrutura , Oxirredução , Tamanho da Partícula , Extratos Vegetais/química , Proteínas de Plantas/química , Polifenóis/química , Citrato de Sódio/química , Eletricidade Estática , Açúcares/química
5.
Sensors (Basel) ; 18(11)2018 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-30441776

RESUMO

A rapid and sensitive sandwich electrochemical immunosensor was developed based on the fabrication of the graphene/polyaniline (GP/PANI) nanocomposite onto screen-printed gold electrode (SPGE) for detection of tuberculosis biomarker 10-kDa culture filtrate protein (CFP10). The prepared GP/PANI nanocomposite was characterized using Fourier transform infrared spectroscopy (FTIR) and field emission scanning electron microscopy (FESEM). The chemical bonding and morphology of GP/PANI-modified SPGE were studied by Raman spectroscopy and FESEM coupled with energy dispersive X-ray spectroscopy, respectively. From both studies, it clearly showed that GP/PANI was successfully coated onto SPGE through drop cast technique. Cyclic voltammetry was used to study the electrochemical properties of the modified electrode. The effective surface area for GP/PANI-modified SPGE was enhanced about five times compared with bare SPGE. Differential pulse voltammetry was used to detect the CFP10 antigen. The GP/PANI-modified SPGE that was fortified with sandwich type immunosensor exhibited a wide linear range (20⁻100 ng/mL) with a low detection limit of 15 ng/mL. This proposed electrochemical immunosensor is sensitive, low sample volume, rapid and disposable, which is suitable for tuberculosis detection in real samples.


Assuntos
Técnicas Biossensoriais , Fragmentos de Peptídeos/isolamento & purificação , Tuberculose/diagnóstico , Compostos de Anilina/química , Diagnóstico Precoce , Técnicas Eletroquímicas/métodos , Grafite/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Microscopia Eletrônica de Varredura/métodos , Mycobacterium tuberculosis/isolamento & purificação , Mycobacterium tuberculosis/patogenicidade , Fragmentos de Peptídeos/imunologia , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Tuberculose/imunologia
6.
Sensors (Basel) ; 18(6)2018 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-29899214

RESUMO

In the present study, a beneficial approach for the ultrasensitive and affordable naked eye detection and diagnosis of tuberculosis (TB) by utilizing plasmonic enzyme-linked immunosorbent assay (ELISA) via antibody-antigen interaction was studied. Here, the biocatalytic cycle of the intracellular enzymes links to the formation and successive growth of the gold nanoparticles (GNPs) for ultrasensitive detection. The formation of different colored solutions by the plasmonic nanoparticles in the presence of enzyme labels links directly to the existence or non-existence of the TB analytes in the sample solutions. For disease detection, the adapted protocol is based mainly on the conventional ELISA procedure that involves catalase-labeled antibodies, i.e., the enzymes consume hydrogen peroxide and further produce GNPs with the addition of gold (III) chloride. The amount of hydrogen peroxide remaining in the solution determines whether the GNPs solution is to be formed in the color blue or the color red, as it serves as a confirmation for the naked eye detection of TB analytes. However, the conventional ELISA method only shows tonal colors that need a high concentration of analyte to achieve high confidence levels for naked eye detection. Also, in this research, we proposed the incorporation of protein biomarker, Mycobacterium tuberculosis ESAT-6-like protein esxB (CFP-10), as a means of TB detection using plasmonic ELISA. With the use of this technique, the CFP-10 detection limit can be lowered to 0.01 µg/mL by the naked eye. Further, our developed technique was successfully tested and confirmed with sputum samples from patients diagnosed with positive TB, thereby providing enough evidence for the utilization of our technique in the early diagnosis of TB disease.


Assuntos
Proteínas de Bactérias/análise , Ensaio de Imunoadsorção Enzimática , Tuberculose/diagnóstico , Proteínas de Bactérias/imunologia , Ouro/química , Humanos , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/metabolismo , Limite de Detecção , Nanopartículas Metálicas/química , Mycobacterium tuberculosis/metabolismo , Tuberculose/microbiologia
7.
Biosens Bioelectron ; 93: 21-25, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27916536

RESUMO

A new lateral flow strip assay (LFSA) using a pair of aptamers has been designed and successfully developed using a pair of aptamers-functionalized with gold nanoparticles (AuNPs). This new LFSA biosensor system utilizes a cognate aptamer duo binding to vaspin, a target protein, at the two different binding sites, and exhibited a sensitive and highly selective response to vaspin. A sandwich-type format in LFSA was developed based on biotin-labeled primary V1 aptamer immobilized on streptavidin coated membrane as a capturing probe and secondary V49 aptamer conjugated with AuNPs as a signaling probe. Using this LFSA, vaspin could be visibly observed within the detectable concentrations of vaspin up to 5nM in both buffer and serum conditions. The sensitivity of this LFSA developed in this study was ranged from 0.137 to 25nM in buffer and from 0.105 to 25nM in spiked human serum, respectively. The limit of detection (LOD) of this LFSA was found to be 0.137nM and 0.105nM in buffer and spiked human serum condition, respectively. Therefore, this study has shown successful development of a simple yet effective LFSA for vaspin detection, and this development is not only limited to this target, but also other targets with a pair of aptamers available, without any special and laborious instrumentations. This system will be particularly useful as a screening tool for rapid on-site detection of any targets with a pair of aptamers generated.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Nanopartículas Metálicas/química , Serpinas/sangue , Biotina/química , Ouro/química , Humanos , Limite de Detecção , Serpinas/química , Estreptavidina/química , Trombina/química
8.
Biosens Bioelectron ; 70: 261-7, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25829224

RESUMO

A cognate aptamer duo for visceral adipose tissue-derived serpin (vaspin) which distinctively bind to two different sites on vaspin with high affinity and specificity were successfully developed by using graphene oxide-based systematic evolution of ligands by exponential enrichment (GO-SELEX), which offers immobilization-free screening of aptamers. The specific and simultaneous bindings of this aptamer duo (V1 and V49 aptamers) to the different sites of vaspin were confirmed by circular dichroism (CD) analysis and both sandwich-type surface plasmon resonance (SPR) and quantum dot labelled fluorescence imaging analysis (V1 aptamer serves as primary capturing aptamer and V49 aptamer as secondary signalling aptamer or vice versa). With this vaspin cognate aptamer duo on SPR platform, the detection of the target vaspin were improved to the limit of detection down to 3.5 ng/ml in buffer and 4.7 ng/ml in human serum samples. This cognate aptamer duo based biosensor could be utilized in the early diagnosis of type-2 diabetes.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas de Amplificação de Ácido Nucleico/métodos , Serpinas/sangue , Ressonância de Plasmônio de Superfície/métodos , Aptâmeros de Nucleotídeos/genética , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Serpinas/genética
9.
Chem Commun (Camb) ; 50(1): 40-2, 2014 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-24185440

RESUMO

A shortened 8-mer ssDNA aptamer was successfully truncated for four different tetracyclines with high affinity. The ultrasensitive colorimetric detection of oxytetracycline using this shortened aptamer was possible, which was about 500-fold enhanced compared to that obtained using the original 76-mer aptamer.


Assuntos
Aptâmeros de Nucleotídeos/genética , Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , Tetraciclina/análise , Tetraciclina/metabolismo , Sequência de Bases , Colorimetria , DNA de Cadeia Simples/genética , DNA de Cadeia Simples/metabolismo , Limite de Detecção , Tetraciclina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...