Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
NMR Biomed ; : e5228, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169274

RESUMO

Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.

2.
Clin Neurol Neurosurg ; 244: 108414, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39002271

RESUMO

OBJECTIVE: Indocyanine green (ICG) and sodium fluorescein (Na-Fl) are two fluorophores, which are used for videoangiography purposes. This prospective study reports our experience by using surgical microscopes equipped with two special filters. We compared the imaging efficacy of Na-FL and ICG videoangiography techniques during aneurysm and arteriovenous malformations (AVM) surgeries. PATIENT AND METHODS: Fourtynine consecutive patients were operated between September 2015 and December 2022. Patients with ruptured/unruptured aneurysms or with AVMs presented with/without hemorrhage were included to the current study. RESULTS: There were a total of 48 aneurysms and 11 AVMs in 49 patients in the current study. Na-Fl enables the surgeon to manipulate vessels and aneurysms real-time. ICG provides the ability to watch the videoangiography repeatedly and understand the angioarchitecture. The use of FLOW-800 module allows the surgeon to make concrete judgements about the flow dynamics of AVMs and therefore ICG videoangiography found useful in AVM surgery. Na-Fl has been found more useful for the evalution of the low caliber perforating arteries and anatomical features of the aneursym dome in aneurysm surgery. CONCLUSION: The results of our series demonstrated the safety and efficacy of Na-Fl use in the surgery of aneurysms and AVMs. Both the ICG and Na-Fl videoangiographies are easy to perform and complimentary to each other. Combined use of these two mediums may provide better surgical results, considering the separate advantages and disadvantages of these both techniques.


Assuntos
Angiografia Cerebral , Fluoresceína , Verde de Indocianina , Aneurisma Intracraniano , Malformações Arteriovenosas Intracranianas , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Malformações Arteriovenosas Intracranianas/cirurgia , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Angiografia Cerebral/métodos , Idoso , Procedimentos Neurocirúrgicos/métodos , Estudos Prospectivos , Corantes , Adulto Jovem , Monitorização Intraoperatória/métodos
3.
MAGMA ; 37(4): 721-735, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39042205

RESUMO

OBJECTIVE: Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS: Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS: In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION: This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Próstata , Razão Sinal-Ruído , Humanos , Masculino , Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes
4.
MAGMA ; 37(3): 429-438, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38743377

RESUMO

OBJECT: To enable high-quality physics-guided deep learning (PG-DL) reconstruction of large-scale 3D non-Cartesian coronary MRI by overcoming challenges of hardware limitations and limited training data availability. MATERIALS AND METHODS: While PG-DL has emerged as a powerful image reconstruction method, its application to large-scale 3D non-Cartesian MRI is hindered by hardware limitations and limited availability of training data. We combine several recent advances in deep learning and MRI reconstruction to tackle the former challenge, and we further propose a 2.5D reconstruction using 2D convolutional neural networks, which treat 3D volumes as batches of 2D images to train the network with a limited amount of training data. Both 3D and 2.5D variants of the PG-DL networks were compared to conventional methods for high-resolution 3D kooshball coronary MRI. RESULTS: Proposed PG-DL reconstructions of 3D non-Cartesian coronary MRI with 3D and 2.5D processing outperformed all conventional methods both quantitatively and qualitatively in terms of image assessment by an experienced cardiologist. The 2.5D variant further improved vessel sharpness compared to 3D processing, and scored higher in terms of qualitative image quality. DISCUSSION: PG-DL reconstruction of large-scale 3D non-Cartesian MRI without compromising image size or network complexity is achieved, and the proposed 2.5D processing enables high-quality reconstruction with limited training data.


Assuntos
Vasos Coronários , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Humanos , Imageamento Tridimensional/métodos , Vasos Coronários/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Física
5.
Neurocirugia (Astur : Engl Ed) ; 35(5): 225-232, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38642616

RESUMO

INTRODUCTION AND OBJECTIVES: We aimed to assess the outcomes of patients with trigeminal neuralgia (TGN) who underwent Gamma Knife radiosurgery (GKRS). MATERIALS AND METHODS: Fifty-three patients with typical TGN underwent GKRS from May 2012 until December 2022. Among these patients, 45 patients who were follow-up for at least 12 months were included in the study. A mean dose of 87.5 Gy (range, 80-90) was administered to the trigeminal nerve. Postoperatively, outcome was considered excellent if the patient was pain- and medication-free. RESULTS: The mean symtpom duration was 9.53 years, and the mean patient age was 59.8 years (range, 34-85). The mean follow-up period was 46.8 months (range, 12-127 months). 46.7% of patients had a history of previous surgical interventions. A single nerve division was affected in 14 patients (31.1%), and multiple divisions were affected in 31 patients (68.9%). The rate of initial pain relief was 80%. Hypoesthesia in the area of trigeminal nerve developed in 30 (66.7%). Twenty patients (44.4%) exhibited excellent results within 72.4 months. Recurrence occurred in 11 patients (24.4%) with 27.6 months. CONCLUSIONS: Our results suggest that GKRS is a safe and effective procedure. Thus, it is an attractive first- and second-line treatment choice for TGN.


Assuntos
Radiocirurgia , Neuralgia do Trigêmeo , Humanos , Neuralgia do Trigêmeo/cirurgia , Neuralgia do Trigêmeo/radioterapia , Radiocirurgia/métodos , Pessoa de Meia-Idade , Feminino , Idoso , Masculino , Idoso de 80 Anos ou mais , Adulto , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Recidiva
6.
Neurocirugia (Astur : Engl Ed) ; 35(5): 267-271, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38588801

RESUMO

Hemiballism/hemichorea (HH) is a hyperkinetic movement disorder observed mostly in older adults with cerebrovascular diseases. Although the symptoms improve without any treatment, lesioning or DBS (deep brain stimulation) may be rarely required to provide symptomatic relief for patients with severe involuntary movements. HH is a rare complication of uncontrolled diabetes. There are only a few reported cases of diabetic HH that have been surgically treated. Thus, herein, we have reported the case of a 75-year-old female with type-II diabetes mellitus that presented with disabling involuntary limb movements of the left side, despite being treated conservatively for six months. DBS targeting the globus pallidus internus (GPi) and ventral intermediate (Vim) thalamic nucleus was performed. Complete resolution of symptoms was achieved with a combined stimulation of the thalamic Vim nucleus (at 1.7 mA) and GPi (at 2.4 mA). The combined stimulation of the Vim nucleus and GPi effectively resolved the diabetes-induced HH symptoms in our patient. Thus, although certain conclusions cannot be drawn due to the rarity of the surgically treated patients with HH, the combined stimulation is a novel treatment option for resistant HH.


Assuntos
Coreia , Estimulação Encefálica Profunda , Diabetes Mellitus Tipo 2 , Discinesias , Globo Pálido , Humanos , Feminino , Idoso , Diabetes Mellitus Tipo 2/complicações , Discinesias/etiologia , Discinesias/terapia , Coreia/etiologia , Coreia/terapia , Núcleos Ventrais do Tálamo , Tálamo
7.
Magn Reson Med ; 91(6): 2498-2507, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38247050

RESUMO

PURPOSE: To mitigate B 1 + $$ {B}_1^{+} $$ inhomogeneity at 7T for multi-channel transmit arrays using unsupervised deep learning with convolutional neural networks (CNNs). METHODS: Deep learning parallel transmit (pTx) pulse design has received attention, but such methods have relied on supervised training and did not use CNNs for multi-channel B 1 + $$ {B}_1^{+} $$ maps. In this work, we introduce an alternative approach that facilitates the use of CNNs with multi-channel B 1 + $$ {B}_1^{+} $$ maps while performing unsupervised training. The multi-channel B 1 + $$ {B}_1^{+} $$ maps are concatenated along the spatial dimension to enable shift-equivariant processing amenable to CNNs. Training is performed in an unsupervised manner using a physics-driven loss function that minimizes the discrepancy of the Bloch simulation with the target magnetization, which eliminates the calculation of reference transmit RF weights. The training database comprises 3824 2D sagittal, multi-channel B 1 + $$ {B}_1^{+} $$ maps of the healthy human brain from 143 subjects. B 1 + $$ {B}_1^{+} $$ data were acquired at 7T using an 8Tx/32Rx head coil. The proposed method is compared to the unregularized magnitude least-squares (MLS) solution for the target magnetization in static pTx design. RESULTS: The proposed method outperformed the unregularized MLS solution for RMS error and coefficient-of-variation and had comparable energy consumption. Additionally, the proposed method did not show local phase singularities leading to distinct holes in the resulting magnetization unlike the unregularized MLS solution. CONCLUSION: Proposed unsupervised deep learning with CNNs performs better than unregularized MLS in static pTx for speed and robustness.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Encéfalo/diagnóstico por imagem
8.
bioRxiv ; 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38076916

RESUMO

Purpose: To develop an extension to locally low rank (LLR) denoising techniques based on transform domain processing that reduces the number of images required in the MR image series for high-quality denoising. Theory and Methods: LLR methods with random matrix theory-based thresholds are successfully used in the denoising of MR image series in a number of applications. The performance of these methods depend on how well the LLR assumption is satisfied, which deteriorates with few numbers of images, as is commonly encountered in quantitative MRI applications. We propose a transform-domain approach for denoising of MR image series to represent the underlying signal with higher fidelity when using a locally low rank approximation. The efficacy of the method is demonstrated for fully-sampled k-space, undersampled k-space, DICOM images, and complex-valued SENSE-1 images in quantitative MRI applications with as few as 4 images. Results: For both MSK and brain applications, the transform domain denoising preserves local subtle variability, whereas the quantitative maps based on image domain LLR methods tend to be locally more homogeneous. Conclusion: A transform domain extension to LLR denoising produces high quality images and is compatible with both raw k-space data and vendor reconstructed data. This allows for improved imaging and more accurate quantitative analyses and parameters obtained therefrom.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38083374

RESUMO

Real-time cine cardiac MRI provides an ECG-free free-breathing alternative to clinical gold-standard ECG-gated breath-hold segmented cine MRI for evaluation of heart function. Real-time cine MRI data acquisition during free breathing snapshot imaging enables imaging of patient cohorts that cannot be imaged with segmented or breath-hold acquisitions, but requires rapid imaging to achieve sufficient spatial-temporal resolutions. However, at high acceleration rates, conventional reconstruction techniques suffer from residual aliasing and temporal blurring, including advanced methods such as compressed sensing with radial trajectories. Recently, deep learning (DL) reconstruction has emerged as a powerful tool in MRI. However, its utility for free-breathing real-time cine MRI has been limited, as database-learning of spatio-temporal correlations with varying breathing and cardiac motion patterns across subjects has been challenging. Zero-shot self-supervised physics-guided deep learning (PG-DL) reconstruction has been proposed to overcome such challenges of database training by enabling subject-specific training. In this work, we adapt zero-shot PG-DL for real-time cine MRI with a spatio-temporal regularization. We compare our method to TGRAPPA, locally low-rank (LLR) regularized reconstruction and database-trained PG-DL reconstruction, both for retrospectively and prospectively accelerated datasets. Results on highly accelerated real-time Cartesian cine MRI show that the proposed method outperforms other reconstruction methods, both visibly in terms of noise and aliasing, and quantitatively.


Assuntos
Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem
10.
PLoS One ; 18(7): e0283972, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37478080

RESUMO

The aim of this study is to develop and evaluate a regularized Simultaneous Multi-Slice (SMS) reconstruction method for improved Cardiac Magnetic Resonance Imaging (CMR). The proposed reconstruction method, SMS with COmpOsition of k-space IntErpolations (SMS-COOKIE) combines the advantages of Iterative Self-consistent Parallel Imaging Reconstruction (SPIRiT) and split slice-Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA), while allowing regularization for further noise reduction. The proposed SMS-COOKIE was implemented with and without regularization, and validated using a Saturation Pulse-Prepared Heart rate Independent inversion REcovery (SAPPHIRE) myocardial T1 mapping sequence. The performance of the proposed reconstruction method was compared to ReadOut (RO)-SENSE-GRAPPA and split slice-GRAPPA, on both retrospectively and prospectively three-fold SMS-accelerated data with an additional two-fold in-plane acceleration. All SMS reconstruction methods yielded similar T1 values compared to single band imaging. SMS-COOKIE showed lower spatial variability in myocardial T1 with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). The proposed method with additional locally low rank (LLR) regularization reduced the spatial variability, again with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). In conclusion, improved reconstruction quality was achieved with the proposed SMS-COOKIE, which also provided lower spatial variability with significant improvement over split slice-GRAPPA.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Miocárdio , Coração/diagnóstico por imagem , Algoritmos , Encéfalo , Imagens de Fantasmas
11.
IEEE Signal Process Mag ; 40(1): 98-114, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37304755

RESUMO

Physics-driven deep learning methods have emerged as a powerful tool for computational magnetic resonance imaging (MRI) problems, pushing reconstruction performance to new limits. This article provides an overview of the recent developments in incorporating physics information into learning-based MRI reconstruction. We consider inverse problems with both linear and non-linear forward models for computational MRI, and review the classical approaches for solving these. We then focus on physics-driven deep learning approaches, covering physics-driven loss functions, plug-and-play methods, generative models, and unrolled networks. We highlight domain-specific challenges such as real- and complex-valued building blocks of neural networks, and translational applications in MRI with linear and non-linear forward models. Finally, we discuss common issues and open challenges, and draw connections to the importance of physics-driven learning when combined with other downstream tasks in the medical imaging pipeline.

12.
Magn Reson Med ; 90(4): 1363-1379, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37246420

RESUMO

PURPOSE: The aim of this study is to develop and optimize an adiabatic T 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ ( T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ ) mapping method for robust quantification of spin-lock (SL) relaxation in the myocardium at 3T. METHODS: Adiabatic SL (aSL) preparations were optimized for resilience against B 0 $$ {\mathrm{B}}_0 $$ and B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities using Bloch simulations. Optimized B 0 $$ {\mathrm{B}}_0 $$ -aSL, Bal-aSL and B 1 $$ {\mathrm{B}}_1 $$ -aSL modules, each compensating for different inhomogeneities, were first validated in phantom and human calf. Myocardial T 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ mapping was performed using a single breath-hold cardiac-triggered bSSFP-based sequence. Then, optimized T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ preparations were compared to each other and to conventional SL-prepared T 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ maps (RefSL) in phantoms to assess repeatability, and in 13 healthy subjects to investigate image quality, precision, reproducibility and intersubject variability. Finally, aSL and RefSL sequences were tested on six patients with known or suspected cardiovascular disease and compared with LGE, T 1 $$ {\mathrm{T}}_1 $$ , and ECV mapping. RESULTS: The highest T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ preparation efficiency was obtained in simulations for modules comprising 2 HS pulses of 30 ms each. In vivo T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ maps yielded significantly higher quality than RefSL maps. Average myocardial T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ values were 183.28 ± $$ \pm $$ 25.53 ms, compared with 38.21 ± $$ \pm $$ 14.37 ms RefSL-prepared T 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ . T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ maps showed a significant improvement in precision (avg. 14.47 ± $$ \pm $$ 3.71% aSL, 37.61 ± $$ \pm $$ 19.42% RefSL, p < 0.01) and reproducibility (avg. 4.64 ± $$ \pm $$ 2.18% aSL, 47.39 ± $$ \pm $$ 12.06% RefSL, p < 0.0001), with decreased inter-subject variability (avg. 8.76 ± $$ \pm $$ 3.65% aSL, 51.90 ± $$ \pm $$ 15.27% RefSL, p < 0.0001). Among aSL preparations, B 0 $$ {\mathrm{B}}_0 $$ -aSL achieved the better inter-subject variability. In patients, B 1 $$ {\mathrm{B}}_1 $$ -aSL preparations showed the best artifact resilience among the adiabatic preparations. T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ times show focal alteration colocalized with areas of hyper-enhancement in the LGE images. CONCLUSION: Adiabatic preparations enable robust in vivo quantification of myocardial SL relaxation times at 3T.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Coração/diagnóstico por imagem , Miocárdio , Suspensão da Respiração , Imagens de Fantasmas
13.
bioRxiv ; 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36824797

RESUMO

Real-time cine cardiac MRI provides an ECG-free free-breathing alternative to clinical gold-standard ECG-gated breath-hold segmented cine MRI for evaluation of heart function. Real-time cine MRI data acquisition during free breathing snapshot imaging enables imaging of patient cohorts that cannot be imaged with segmented or breath-hold acquisitions, but requires rapid imaging to achieve sufficient spatial-temporal resolutions. However, at high acceleration rates, conventional reconstruction techniques suffer from residual aliasing and temporal blurring, including advanced methods such as compressed sensing with radial trajectories. Recently, deep learning (DL) reconstruction has emerged as a powerful tool in MRI. However, its utility for free-breathing real-time cine MRI has been limited, as database-learning of spatio-temporal correlations with varying breathing and cardiac motion patterns across subjects has been challenging. Zero-shot self-supervised physics-guided deep learning (PG-DL) reconstruction has been proposed to overcome such challenges of database training by enabling subject-specific training. In this work, we adapt zero-shot PG-DL for real-time cine MRI with a spatio-temporal regularization. We compare our method to TGRAPPA, locally low-rank (LLR) regularized reconstruction and database-trained PG-DL reconstruction, both for retrospectively and prospectively accelerated datasets. Results on highly accelerated real-time Cartesian cine MRI show that the proposed method outperforms other reconstruction methods, both visibly in terms of noise and aliasing, and quantitatively.

14.
Neuroimage ; 270: 119949, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36804422

RESUMO

As the neuroimaging field moves towards detecting smaller effects at higher spatial resolutions, and faster sampling rates, there is increased attention given to the deleterious contribution of unstructured, thermal noise. Here, we critically evaluate the performance of a recently developed reconstruction method, termed NORDIC, for suppressing thermal noise using datasets acquired with various field strengths, voxel sizes, sampling rates, and task designs. Following minimal preprocessing, statistical activation (t-values) of NORDIC processed data was compared to the results obtained with alternative denoising methods. Additionally, we examined the consistency of the estimates of task responses at the single-voxel, single run level, using a finite impulse response (FIR) model. To examine the potential impact on effective image resolution, the overall smoothness of the data processed with different methods was estimated. Finally, to determine if NORDIC alters or removes temporal information important for modeling responses, we employed an exhaustive leave-p-out cross validation approach, using FIR task responses to predict held out timeseries, quantified using R2. After NORDIC, the t-values are increased, an improvement comparable to what could be achieved by 1.5 voxels smoothing, and task events are clearly visible and have less cross-run error. These advantages are achieved with smoothness estimates increasing by less than 4%, while 1.5 voxel smoothing is associated with increases of over 140%. Cross-validated R2s based on the FIR models show that NORDIC is not measurably distorting the temporal structure of the data under this approach and is the best predictor of non-denoised time courses. The results demonstrate that analyzing 1 run of data after NORDIC produces results equivalent to using 2 to 3 original runs and that NORDIC performs equally well across a diverse array of functional imaging protocols. Significance Statement: For functional neuroimaging, the increasing availability of higher field strengths and ever higher spatiotemporal resolutions has led to concomitant increase in concerns about the deleterious effects of thermal noise. Historically this noise source was suppressed using methods that reduce spatial precision such as image blurring or averaging over a large number of trials or sessions, which necessitates large data collection efforts. Here, we critically evaluate the performance of a recently developed reconstruction method, termed NORDIC, which suppresses thermal noise. Across datasets varying in field strength, voxel sizes, sampling rates, and task designs, NORDIC produces substantial gains in data quality. Both conventional t-statistics derived from general linear models and coefficients of determination for predicting unseen data are improved. These gains match or even exceed those associated with 1 voxel Full Width Half Max image smoothing, however, even such small amounts of smoothing are associated with a 52% reduction in estimates of spatial precision, whereas the measurable difference in spatial precision is less than 4% following NORDIC.


Assuntos
Neuroimagem Funcional , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem Funcional/métodos , Projetos de Pesquisa , Processamento de Imagem Assistida por Computador/métodos
15.
medRxiv ; 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36711813

RESUMO

This work seeks to evaluate multiple methods for quantitative parameter estimation from standard T2 mapping acquisitions in the prostate. The T2 estimation performance of methods based on neural networks (NN) was quantitatively compared to that of conventional curve fitting techniques. Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Ten combinations of different NN architectures, training strategies, and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst all the methods. On in vivo data, this best-performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.

16.
Magn Reson Med ; 89(1): 308-321, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36128896

RESUMO

PURPOSE: To develop a physics-guided deep learning (PG-DL) reconstruction strategy based on a signal intensity informed multi-coil (SIIM) encoding operator for highly-accelerated simultaneous multislice (SMS) myocardial perfusion cardiac MRI (CMR). METHODS: First-pass perfusion CMR acquires highly-accelerated images with dynamically varying signal intensity/SNR following the administration of a gadolinium-based contrast agent. Thus, using PG-DL reconstruction with a conventional multi-coil encoding operator leads to analogous signal intensity variations across different time-frames at the network output, creating difficulties in generalization for varying SNR levels. We propose to use a SIIM encoding operator to capture the signal intensity/SNR variations across time-frames in a reformulated encoding operator. This leads to a more uniform/flat contrast at the output of the PG-DL network, facilitating generalizability across time-frames. PG-DL reconstruction with the proposed SIIM encoding operator is compared to PG-DL with conventional encoding operator, split slice-GRAPPA, locally low-rank (LLR) regularized reconstruction, low-rank plus sparse (L + S) reconstruction, and regularized ROCK-SPIRiT. RESULTS: Results on highly accelerated free-breathing first pass myocardial perfusion CMR at three-fold SMS and four-fold in-plane acceleration show that the proposed method improves upon the reconstruction methods use for comparison. Substantial noise reduction is achieved compared to split slice-GRAPPA, and aliasing artifacts reduction compared to LLR regularized reconstruction, L + S reconstruction and PG-DL with conventional encoding. Furthermore, a qualitative reader study indicated that proposed method outperformed all methods. CONCLUSION: PG-DL reconstruction with the proposed SIIM encoding operator improves generalization across different time-frames /SNRs in highly accelerated perfusion CMR.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imageamento por Ressonância Magnética/métodos , Física , Perfusão
17.
IEEE Signal Process Mag ; 39(2): 28-44, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36186087

RESUMO

Recently, deep learning approaches have become the main research frontier for biological image reconstruction and enhancement problems thanks to their high performance, along with their ultra-fast inference times. However, due to the difficulty of obtaining matched reference data for supervised learning, there has been increasing interest in unsupervised learning approaches that do not need paired reference data. In particular, self-supervised learning and generative models have been successfully used for various biological imaging applications. In this paper, we overview these approaches from a coherent perspective in the context of classical inverse problems, and discuss their applications to biological imaging, including electron, fluorescence and deconvolution microscopy, optical diffraction tomography and functional neuroimaging.

18.
Front Cardiovasc Med ; 9: 917180, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36247474

RESUMO

Late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR) imaging is the clinical reference for assessment of myocardial scar and focal fibrosis. However, current LGE techniques are confined to imaging of a single cardiac phase, which hampers assessment of scar motility and does not allow cross-comparison between multiple phases. In this work, we investigate a three step approach to obtain cardiac phase-resolved LGE images: (1) Acquisition of cardiac phase-resolved imaging data with varying T 1 weighting. (2) Generation of semi-quantitative T 1 * maps for each cardiac phase. (3) Synthetization of LGE contrast to obtain functional LGE images. The proposed method is evaluated in phantom imaging, six healthy subjects at 3T and 20 patients at 1.5T. Phantom imaging at 3T demonstrates consistent contrast throughout the cardiac cycle with a coefficient of variation of 2.55 ± 0.42%. In-vivo results show reliable LGE contrast with thorough suppression of the myocardial tissue is healthy subjects. The contrast between blood and myocardium showed moderate variation throughout the cardiac cycle in healthy subjects (coefficient of variation 18.2 ± 3.51%). Images were acquired at 40-60 ms and 80 ms temporal resolution, at 3T and 1.5, respectively. Functional LGE images acquired in patients with myocardial scar visualized scar tissue throughout the cardiac cycle, albeit at noticeably lower imaging resolution and noise resilience than the reference technique. The proposed technique bears the promise of integrating the advantages of phase-resolved CMR with LGE imaging, but further improvements in the acquisition quality are warranted for clinical use.

19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1690-1693, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085994

RESUMO

Magnetic Resonance Imaging (MRI) is the clinical gold standard for the assessment of myocardial viability but requires injection of exogenous gadolinium-based contrast agents. Recently, T1ρ-mapping has been proposed as a fully non-invasive alternative for imaging myocardial fibrosis without the need for contrast agent injection. However, its applicability at high fields is hindered by susceptibility to MRI system imperfections, such as inhomogeneities in the B0 and B1+ fields. In this work we propose a single breath-hold ECG-triggered single-shot bSSFP sequence to enable T1ρ-mapping in vivo at 3T. Adiabatic T1ρ preparations are evaluated to reduce B0 and B1+ sensitivity in comparison with conventional spin-lock (SL) modules. Numerical Bloch simulations were performed to identify optimal parameters for the adiabatic pulses. Experiments yield T1ρ values in the myocardium equal to 48.13±54.08 ms for the best adiabatic preparation and 16.01±20.75 ms for the reference non-adiabatic SL, with 26.91% against 89.74% relative difference in T1ρ values across two shimming conditions. Both phantom and in vivo measurements show increased myocardium/blood contrast and improved resilience against system imperfections compared to non-adiabatic T1ρ preparations, enabling the use at 3T. Clinical relevance- Adiabatically-prepared T1ρ-mapping sequences form a promising candidate for non-contrast evaluation of ischemic and non-ischemic cardiomyopathies at 3T.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1472-1476, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086262

RESUMO

Dynamic contrast enhanced (DCE) MRI acquires a series of images following the administration of a contrast agent, and plays an important clinical role in diagnosing various diseases. DCE MRI typically necessitates rapid imaging to provide sufficient spatio-temporal resolution and coverage. Conventional MRI acceleration techniques exhibit limited image quality at such high acceleration rates. Recently, deep learning (DL) methods have gained interest for improving highly-accelerated MRI. However, DCE MRI series show substantial variations in SNR and contrast across images. This hinders the quality and generalizability of DL methods, when applied across time frames. In this study, we propose signal intensity informed multi-coil MRI encoding operator for improved DL reconstruction of DCE MRI. The output of the corresponding inverse problem for this forward operator leads to more uniform contrast across time frames, since the proposed operator captures signal intensity variations across time frames while not altering the coil sensitivities. Our results in perfusion cardiac MRI show that high-quality images are reconstructed at very high acceleration rates, with substantial improvement over existing methods.


Assuntos
Meios de Contraste , Aprendizado Profundo , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Física
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...