Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 30: e943353, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825814

RESUMO

BACKGROUND Dentin contamination with hemostatic agents before bonding indirect restorations negatively affects the bond strength. However, the consensus on which materials could be used to clean contamination of hemostatic agents has not been explored. The aim of this study was to assess the effect of Katana Cleaner applied on the surface of dentin contaminated with hemostatic agents on the shear bond strength (SBS) of self-adhesive resin cement by comparing it with three other surface cleaners. MATERIAL AND METHODS Ninety dentin specimens were divided into a no contamination group (control) (n=10), 4 groups contaminated with 25% aluminum chloride (Viscostat Clear) (n=40), and 4 groups contaminated with 20% ferric sulfate (Viscostat) (n=40). Subsequently, 4 different cleaners were used for each contamination group (water rinse, phosphoric acid, chlorhexidine, and Katana Cleaner). Then, self-adhesive resin cement was directly bonded to the treated surfaces. All specimens were subjected to 5000 thermal cycles of artificial aging. The shear bond strength was measured using a universal testing machine. RESULTS Two-way analysis of variance showed that the contaminant type as the main factor was statistically non-significant (p=0.655), cleaner type as the main factor was highly significant (p<0.001), and interaction between the contaminant and cleaner was non-significant (p=0.51). The cleaner type was the main factor influencing the bond strength. Phosphoric acid and chlorhexidine showed better performance than Katana Cleaner. CONCLUSIONS Cleaning dentin surface contamination with phosphoric acid and chlorhexidine had better performance than with Katana Cleaner.


Assuntos
Colagem Dentária , Dentina , Hemostáticos , Cimentos de Resina , Resistência ao Cisalhamento , Humanos , Dentina/efeitos dos fármacos , Hemostáticos/farmacologia , Colagem Dentária/métodos , Clorexidina/análogos & derivados , Clorexidina/farmacologia , Teste de Materiais/métodos , Propriedades de Superfície/efeitos dos fármacos , Adesivos Dentinários , Compostos Férricos/química
2.
BMC Oral Health ; 24(1): 38, 2024 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-38185744

RESUMO

BACKGROUND: Various methods can be used for creating zirconia dental restorations, including 3-dimensional (3D) printing and computer-aided design/ computer-aided manufacturing (CAD/CAM) milling. The fused deposition modeling (FDM) printing method for zirconia presents numerous advantages, albeit research on the mechanical properties of these materials and resultant restorations remains scarce. Such developments are undeniably intriguing and warrant further investigation. The objective of the present study was to evaluate the impact of the sintering firing cycle (Conventional vs. Speed sintering) on the flexural strength, flexural modulus, and Vickers Microhardness of milled vs. FDM printed zirconia. METHODS: A total of 60 bars (2 × 5 × 27 mm) were fabricated for flexural strength testing, along with 40 discs (12 × 1.5 mm) for Vickers microhardness testing. Half of the specimens underwent conventional sintering, while the other half underwent a speed sintering cycle. The flexural strength and modulus were determined by a three-point bending test in a universal testing machine. The microhardness of the specimens was evaluated using a Vickers microhardness tester. Statistical analysis was performed using a two-way ANOVA test with a post-hoc Tukey test (p < 0.05). RESULTS: CAD/CAM milled zirconia had significantly higher flexural strength and modulus than FDM-printed zirconia. The sintering process did not significantly affect the flexural strength or modulus of milled or FDM-printed zirconia. The milled speed sintering group had significantly higher values in the Vickers microhardness test compared to the other groups. CONCLUSIONS: The mechanical properties of FDM-printed zirconia specimens were not found to be comparable to those of milled zirconia. Speed sintering cycle may produce milled zirconia restorations with similar flexural strength and modulus to conventional sintering, and even higher Vickers Microhardness values.


Assuntos
Desenho Assistido por Computador , Resistência à Flexão , Humanos , Análise de Variância , Impressão Tridimensional
3.
Materials (Basel) ; 16(18)2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37763425

RESUMO

The aim of this study was to investigate the effect of repeated pressing of lithium disilicate ceramic on the shear bond strength (SBS) of three types of resin cement. METHODOLOGY: A lithium disilicate ceramic (IPS e.max® Press) was first heat-pressed to form rectangular disk specimens. Then, leftovers were used for the second and third presses. A total of 90 specimens were prepared and separated, according to the number of pressing cycles, into three groups: 1st, 2nd, and 3rd presses (n = 30). Each group was further subdivided into three groups (n = 10) according to the type of resin cement used, as follows: Multilink N (MN), Variolink Esthetic DC (VDC), and Variolink Esthetic LC (VLC). All the cement was bonded to the ceramic surface, which was etched with hydrofluoric acid and primed with Monobond Plus. All samples were light-cured and stored for 24 h. Shear bond strength was tested on a universal testing machine. RESULTS: A two-way ANOVA was used to evaluate the influence of repeated pressing cycles and cement type as well as their interaction. The results indicated that cement type has a significant impact (p < 0.001) but not the number of pressing cycles (p = 0.970) or their interaction (p = 0.836). The Bonferroni post-hoc test showed that the SBS of MN was significantly higher than that of VDC and VLC in the first press and second press cycles, respectively. The SBS of MN was significantly higher than that of VDC and VLC cements in the third pressing cycle. There was no significant difference in the SBS between VLC and VDC in all three pressing cycles. CONCLUSION: The results of the current study did not report a detrimental effect of repeated pressing up to three cycles on the shear bond strength of the IPS e.max® Press. Multilink resin cement showed the highest SBS to IPS e.max® Press at the third pressing cycle. For all types of cement and heat pressing cycles, the majority of cement failures were adhesive. No cohesive failures occurred in any of the tested resin cements, regardless of the cement type or the number of heat pressing cycles tested.

4.
Bioengineering (Basel) ; 10(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37370594

RESUMO

The emergence of digital dentistry has led to the introduction of various three-dimensional (3D) printing materials in the market, specifically for provisional fixed restoration. This study aimed to undertake a systematic review of the published literature on the Mechanical Properties of 3D- Printed Provisional Resin Materials for crown and fixed dental prosthesis (FDP). The electronic database on PubMed/Medline was searched for relevant studies. The search retrieved articles that were published from January 2011 to March 2023. The established focus question was: "Do provisional 3D-printed materials have better mechanical properties than conventional or milled provisional materials?". The systematically extracted data included the researcher's name(s), publication year, evaluation method, number of samples, types of materials, and study outcome. A total of 19 studies were included in this systematic review. These studies examined different aspects of the mechanical properties of 3D-printed provisional materials. Flexural Strength and Microhardness were the frequently used mechanical testing. Furthermore, 3D-printed provisional restorations showed higher hardness, smoother surfaces, less wear volume loss, and higher wear resistance compared to either milled or conventional, or both. 3D-printed provisional resin materials appear to be a promising option for fabricating provisional crowns and FDPs.

5.
PeerJ ; 10: e14135, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36221260

RESUMO

Background and Objectives: White spot lesions (WSLs) are a common problem that can be conservatively managed by resin infiltration. Consumption of dark beverages such as coffee causes staining of dental hard tissues, which can deteriorate the esthetic qualities of treated WSLs. The aims of this study were to investigate the effect of dark coffee heavy consumption on ICON® resin infiltrated WSLs and the influence of bleaching on them after staining. Methods: Twenty surfaces from sound human extracted third molars were used in the study. Two square-shaped buccal and lingual window areas had artificially created WSLs (received buccal resin infiltration afterward). Using VITA Easyshade, the baseline ΔE was recorded. Espresso coffee was used to immerse all surfaces for 8 days. The color coordinates according to CIE LAB were recorded for all surfaces at 2, 4, 6, and 8 days of immersion, and ΔE was calculated at each timepoint. After 8 days, in-office bleaching was applied to all surfaces according to the manufacturer's instructions and the color. Coordinates and ΔE were recorded. For statistical analysis, an independent sample t-test was used to compare each group. A general linear mixed model (GLMM) repeated measure ANOVA was applied for statistical analysis of L*and changes due to staining over time. Results: Analysis of time as a main effect on the L values of surfaces was statistically highly significant (p < 0.01). The interaction of time with surfaces under investigation and type of surface (test vs. control) as a main effect were non-significant (p = 0.47 and p = 0.35, respectively). Bleaching showed a significant difference in color lightness in both test and control surfaces compared to the mean L value at 8 days of staining (p < 0.01). Conclusion: Capsule-coffee consumption gradually influences the esthetic of resin infiltration on treated teeth. However, bleaching materials might restore an esthetic shade.


Assuntos
Cárie Dentária , Resinas Sintéticas , Humanos , Café , Cor , Espectrofotometria , Resinas Vegetais , Esmalte Dentário
6.
Materials (Basel) ; 15(19)2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36234124

RESUMO

The aim of this study was to investigate the effect of repressing leftover heat-pressed lithium disilicate material on its mechanical and optical properties. A lithium disilicate ingot (IPS e.max® Press, IvoclarVivadent, Schaan, Liechtenstein) shade (A1) low translucency was first heat-pressed to yield ceramic bars and disks. Then, the second and third presses were fabricated from the leftovers of the previous pressing cycles. A total of 36 bars and 15 disk specimens were fabricated and divided into three groups according to the number of pressing cycles (n = 12 bars and n = 5 disks): P1: first press (control), P2: second press, and P3: third press. The specimens were tested for flexural strength, color change, Vickers hardness, and surface topography under scanning electron microscopy. One-way ANOVA testing was used to evaluate flexural strength and hardness, while an independent t-test was performed to evaluate color change. There was no significant difference in flexural strength as the number of heat-pressed cycles increased (p = 0.283). Similarly, there was no significant difference in the microhardness values between all groups (p = 0.220). The overall color change ∆E between P1-P2 and P1-P3 were 2.01 and 2.14, respectively. The SEM images showed evenly distributed and densely packed lithium disilicate crystals in the P1 group. However, larger and less densely packed crystals were noticeable in P2 and P3. The IPS e.max Press could be repressed up to two times without an adverse effect on mechanical properties or color stability. These results may support the reuse of pressed lithium disilicate for economical purposes, but further clinical evaluation should be conducted to confirm these findings.

7.
Cureus ; 14(8): e27831, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36106305

RESUMO

One of the most challenging steps in dentistry is taking final impressions for full mouth rehabilitation of a dentate patient. Final impressions should include the necessary details needed to fabricate a definitive cast. This cast will be used to construct indirect restorations in the laboratory. Besides all the improvement of impression materials and systems used for taking final impressions, the intraoral cavity is a challenging environment and there are some cases that prevent clinicians from recording the needed details in a single final impression. The objective of this case report is to describe a technique for fabrication of a definitive cast for a full mouth rehabilitation case by using resin-transfer coping impression technique. This technique is used as an alternative option for cases that prevent the clinician from capturing all the needed details in a single full-arch final impression.

8.
J Prosthet Dent ; 126(6): 787-792, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33172647

RESUMO

STATEMENT OF PROBLEM: Evidence for the accuracy of a recently introduced intraoral scanner is lacking. PURPOSE: The purpose of this in vitro study was to evaluate and compare the trueness (validity) and precision (reliability) of 2 intraoral scanners by scanning a quadrant and a sextant. MATERIAL AND METHODS: A maxillary typodont with plastic teeth made from a shade A3 polymethyl methacrylate was scanned (n=10) with each intraoral scanner (Planmeca Emerald and 3Shape TRIOS 3) to obtain sextant and quadrant scans. Control scans were made with an industrial optical scanner. The scans were analyzed with a 3D reverse engineering software program and an independent samples t test and general linear model 2-way analysis of variance (α=.05). RESULTS: The 3Shape TRIOS 3 scanner showed no significant difference between the sextant and quadrant scans in trueness (P=.118) or in precision (P<.285). The Emerald scanner had statistically significant higher trueness for the sextant scan (P=.007). The 3Shape TRIOS 3 scanner had better performance in trueness and precision when compared with the Emerald scanner. CONCLUSIONS: The 3Shape TRIOS 3 scanner was found to be more accurate than the Emerald scanner in terms of trueness and precision, regardless of the scanning field. The Emerald scanner's trueness decreased as the scanning field increased from a sextant to a quadrant.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Imageamento Tridimensional , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...