Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 212
Filtrar
1.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986659

RESUMO

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Hemodinâmica
2.
Int J Cardiol ; 413: 132340, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38992809

RESUMO

BACKGROUND: The current incidence and outcomes of structural transcatheter procedures in heart transplant (HTx) recipients and left-ventricular assist devices (LVAD) carriers is unknown. AIMS: To provide insights on structural transcatheter procedures performed across HTx and LVAD patients in Spain. METHODS: Multicenter, ambispective, observational nationwide registry. RESULTS: Until May/2023, 36 percutaneous structural interventions were performed (78% for HTx and 22% for LVAD) widely varying among centers (0%-1.4% and 0%-25%, respectively). Percutaneous mitral transcatheter edge-to-edge (TEER) was the most common (n = 12, 33.3%), followed by trancatheter aortic valve replacement (n = 11, 30.5%), and tricuspid procedures (n = 9, 25%). Mitral TEER resulted in mild residual mitral regurgitation in all but one case, mean gradient was <5 mmHg in 75% of them at 1-year, with no mortality and 8.3% re-admission rate. Tricuspid TEER resulted in 100% none/mild residual regurgitation with a 1-year mortality and readmission rates of 22% and 28.5%, respectively. Finally, trancatheter aortic valve replacement procedures (n = 8 in LVADs due to aortic regurgitation and n = 3 in HTx), were successful in all cases with one prosthesis degeneration leading to severe aortic regurgitation at 1-year, 18.2% mortality rate and no re-admissions. Globally, major bleeding rates were 7.9% and 12.5%, thromboembolic events 3.7% and 12.5%, readmissions 37% and 25%, and mortality 22% and 25%, in HTx and LVADs respectively. No death was related to the implanted transcatheter device. CONCLUSIONS: Most centers with HTx/LVAD programs perform structural percutaneous procedures but with very inconsistent incidence. They were associated with good safety and efficacy, but larger studies are required to provide formal recommendations.

3.
Int J Cardiol Heart Vasc ; 53: 101460, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39070183

RESUMO

Objective: Bleeding is frequent during transcatheter aortic valve implantation (TAVI), especially when performed through a transapical approach (TA), and is associated with a worse prognosis. The present study aims to test the implication of red blood cell (RBC) transfusion and the optimal transfusion strategy in this context. Methods: Among 11,265 participants in the multicenter TRITAVI (Transfusion Requirements in Transcatheter Aortic Valve Implantation) registry, 548 patients (4.9%) who received TA-TAVI at 19 European centers were included. One-to-one propensity score matching was performed to reduce treatment selection bias and potential confounding among transfused versus non-transfused patients. The primary endpoint of the study was the 30-day occurrence of all-cause mortality. Results: 209 patients (38 %) received RBC transfusions. The primary endpoint occurred in 47 (8.6 %) patients. Propensity score matching identified 188 pairs of patients with and without RBC transfusion. In the propensity score-matched analysis, RBC transfusion was associated with increased 30-day mortality (HR 3.35, 95 % CI 1.51 - 7.39; p = 0.002). At multivariable cox regression analysis, RBC transfusion was an independent predictor of 30-day mortality (HR 3.07, 95 % CI 1.01-9.41, p = 0.048), as well as baseline ejection fraction (HR 0.96, 95 % CI 0.92-0.99, p = 0.043), and acute kidney injury (HR 3.95, 95 % CI 1.11-14.05, p = 0.034). Conclusions: RBC transfusion is an independent predictor of short-term mortality in patients undergoing TA-TAVI, regardless of major bleeding.Clinical trial registration: https://www.clinicaltrials.gov Unique identifier: NCT03740425.

4.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39068987

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve replacement (TMVR) is an emerging treatment alternative for mitral valve (MV) disease in patients who were ineligible for surgical intervention or edge-to-edge repair. This study aimed to assess the short- and mid-term outcomes of this procedure. METHODS: We conducted a prospective registry to include the initial experience with symptomatic, consecutive patients who underwent TMVR using the transapical Tendyne system at 7 centers in the Iberian Peninsula. Baseline clinical and imaging data, periprocedural information, and follow-up assessments were collected at 1 month and 1 year. RESULTS: A total of 40 patients (mean age 78.5 years [76-82], 47,5% males) underwent TMVR. The majority had significant surgical risk, comorbidities, and advanced functional class. All patients had significant mitral regurgitation (MR), except for 2 with severe stenosis. Previous MV intervention and off-label indication for the procedure were present in 4 (10.0%) and 8 (20.0%) patients, respectively. Technical success was recorded in 100%, device success in 95.0%, and procedural success in 85.0% at 30-day. All-cause mortality was 2.5% and 17.5% at the 1-month and 1-year follow-up, respectively. MR reduction (≤ 1) and functional class improvement (NYHA I-II) were observed at 1 year in 93.9% and 87.9% of survivors, respectively. CONCLUSIONS: Treatment with TMVR produced enduring resolution of MV disease and notable functional enhancement at 1 year of follow-up. The procedure demonstrated a satisfactory early safety profile, although 1-year mortality remained relatively high in this high-risk population.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38829174

RESUMO

BACKGROUND: Vasopressor test (VPT) might be useful in patients with functional mitral regurgitation (MR) and left ventricular dysfunction (MITRA-FR-like patients) during transcatheter edge-to-edge repair (TEER). AIMS: We aimed to evaluate the prognostic impact of VPT. METHODS: MR treated with TEER were included in a multicenter prospective registry. VPT was used intraprocedurally in patients with left ventricular dysfunction and/or hypotension. The 1-year echocardiographic and clinical outcomes were compared according to the use of VPT. The primary endpoint was a combination of mortality + heart failure (HF) readmission at 1-year. RESULTS: A total of 1115 patients were included, mean age was 72.8 ± 10.5 years and 30.4% were women. VPT was performed in 128 subjects (11.5%), more often in critically ill patients with biventricular dysfunction. Postprocedurally the VPT group had greater rate of MR ≥ 2+ (46.9% vs. 31.7%, p = 0.003) despite greater number of devices (≥2 clips, 52% vs. 40.6 p = 0.008) and device repositioning or new clip in 12.5%. At 1-year, the primary endpoint occurred more often in the VPT group (27.3% vs. 16.9%, p = 0.002) as well as all-cause mortality (21.9% vs. 8.1%, p ≤ 0.001) but no differences existed in HF readmission rate (14.8% vs. 13.2%, p = 0.610), cardiovascular mortality (4.4% vs. 3.9%, p = 0.713) or residual MR ≥ 2+ (51.1% vs 51.7%, p = 0.371). CONCLUSIONS: Dynamic evaluation of MR during TEER procedure through VPT was performed in patients with worse baseline risk who also presented higher all-cause mortality at 1-year follow-up. However, 1-year residual MR, cardiovascular mortality and HF readmission rate remained comparable suggesting that VPT might help in the management of MITRA-FR-like patients.

6.
Eur J Heart Fail ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899626

RESUMO

AIMS: Haemodynamic monitoring using implantable pressure sensors reduces the risk of heart failure (HF) hospitalizations. Patient self-management (PSM) of haemodynamics in HF has the potential to personalize treatment, increase adherence, and reduce the risk of worsening HF, while lowering clinicians' burden. METHODS AND RESULTS: The VECTOR-HF I and IIa studies are prospective, single-arm, open-label clinical trials assessing safety, usability and performance of left atrial pressure (LAP)-guided HF management using PSM in New York Heart Association class II and III HF patients. Physician-prescribed LAP thresholds trigger patient self-adjustment of diuretics. Primary endpoints include the ability to perform LAP measurements and transmit data to the healthcare provider (HCP) interface and the patient guidance application, and safety outcomes. This is an interim analysis of 13 patients using the PSM approach. Over 12 months, no procedure- or device-related major adverse cardiovascular or neurological events were observed, and there were no failures to obtain measurements from the sensor and transmit the data to the HCP interface and the patient guidance application. Patient adherence was 91.4%. Using PSM, annualized HF hospitalization rate significantly decreased compared to a similar period prior to PSM utilization (0 admissions vs. 0.69 admissions over 11.84 months, p = 0.004). At 6 months, 6-min walk test distance and the Kansas City Cardiomyopathy Questionnaire overall summary score demonstrated significant improvement. CONCLUSIONS: Interim findings suggest that PSM using a LAP monitoring system is feasible and safe. PSM is associated with high patient adherence, potentially improving HF patients' functional status, quality of life, and limiting HF hospitalizations.

7.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

8.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
Int J Cardiol ; 410: 132179, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38761972

RESUMO

BACKGROUND: Optimal strategies to manage embolization of transcatheter aortic valve implantation (TAVI) devices are unclear; valve-in-valve (ViV) is often used. We aimed to describe through one-single center experience its rate, causes, consequences, and management as well as the rate and relevance of commissural alignment (CA) in this context. METHODS: We identified across 1038 TAVI cases, those cases requiring ViV for the management of first device embolization. CA (absence or mild misalignment) after first and second device was assessed by CT or fluoroscopy. RESULTS: A total of 23 cases (2.2%) were identified, 52.3% embolized towards the aorta and 47.7% towards the ventricle. Suboptimal implant height (38%) and embolization at the time of post-dilation (23%) were the most frequent mechanisms together with greater rate of bicuspid valve (p < 0.001) and a trend to greater annular eccentricity. Procedural and 1-year death occurred in 13% and 34%, respectively (vs. 1.1% and 7.8% in the global cohort, p < 0.001). CA was present in 76.9% of the prostheses initially implanted but was only spontaneously achieved in 30.8% of the second ViV device. Adequate CA of both prostheses was identified in only two cases (8.7%). There were no cases of coronary obstruction. CONCLUSIONS: TAVI device embolization mechanisms can often be predicted and prevented. Mortality following bail-out ViV is higher than in regular TAVI procedures but 2/3 of these patients survived beyond 1-year follow-up. In them, valve degeneration or coronary re-access might be particularly challenging since CA was rarely achieved with both devices suggesting that greater efforts should be made in this regard.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Seguimentos , Desenho de Prótese , Embolia/etiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem
10.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
12.
Glob Heart ; 19(1): 38, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681970

RESUMO

Background: Opium consumption has been an overlooked health issue in the Iranian population, and the prognostic role of opium consumption in patients undergoing coronary revascularization is unknown. Hypothesis: We aimed to assess the association between opium consumption and long-term cardiovascular outcomes after percutaneous coronary intervention (PCI). Methods: We screened 2203 consecutive patients who underwent elective PCI between April 2009 and April 2010 at Tehran Heart Center. Exclusion criteria were unsuccessful PCI, non-elective PCI, and missing opium use data. Opium consumption was defined as self-reported ever use of any traditional opium substances. Outcomes of interest were all-cause mortality and a composite of major adverse cardiac and cerebrovascular events (MACCE). The association between opium use and study outcomes was evaluated using the inverse probability of treatment weighting (IPTW) method. Cumulative hazard curves were demonstrated to further assess the association visually. Furthermore, the effect of opium consumption on individual components of MACCE was evaluated in a competing risk setting. Results: A total of 2025 elective PCI patients were included (age: 58.7 ± 10.67, 29.1% women), among whom 297 (14.6%) patients were opium users. After a median follow-up of 10.7 years, opium consumption was associated with a higher risk of all-cause mortality (IPTW-hazard ratio [HR] = 1.705, 95% CI: 1.125-2.585; P = 0.012) and MACCE (IPTW-HR = 1.578, 95% CI: 1.156-2.153; P = 0.004). The assessment of MACCE components suggested a non-significant borderline trend for higher non-fatal myocardial infarction (IPTW-sub-distribution HR [SHR] = 1.731, 95% CI: 0.928-3.231; P = 0.084) and mortality (IPTW-SHR = 1.441, 95% CI: 0.884-2.351; P = 0.143) among opium users. Conclusions: Opium consumption is associated with a more than 50% increase in long-term risk of mortality and MACCE in patients undergoing PCI. These findings accentuate the importance of preventive strategies to quit opium addiction in this population.


Assuntos
Ópio , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Irã (Geográfico)/epidemiologia , Seguimentos , Fatores de Tempo , Dependência de Ópio/epidemiologia , Fatores de Risco , Doença da Artéria Coronariana/epidemiologia , Idoso , Estudos Retrospectivos , Taxa de Sobrevida/tendências
13.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533944

RESUMO

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Diálise Renal , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Multicêntricos como Assunto
14.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Sistema de Registros , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Remoção de Dispositivo/efeitos adversos , Embolia/etiologia , Embolia/mortalidade , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal , Oclusão do Apêndice Atrial Esquerdo
16.
Mayo Clin Proc ; 99(3): 400-410, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38432746

RESUMO

OBJECTIVE: To describe the evolution of symptoms in patients with symptomatic severe aortic stenosis (sSAS) undergoing valve replacement, the predictors of the persistence of these symptoms, and their prognostic significance. The evolution of symptoms after intervention in sSAS and their association with outcome are unknown. PATIENTS AND METHODS: Data from patients with sSAS who underwent intervention were collected. All-cause mortality and cardiovascular mortality were considered events. The evolution of symptoms and their association with events were studied. RESULTS: In this study, 451 consecutive patients with sSAS and no other valvular or coronary disease who were alive 30 days after intervention were included. Before valve replacement, 133 of the 451 patients (29.5%) had congestive heart failure requiring hospitalization. Of the remaining 318 patients, 287 (90.2%) had dyspnea on effort, 129 (40.6%) had angina, and 59 had syncope (18.6%). Symptoms disappeared after intervention in 192 of the 451 patients (42.6%) and remained in 259 (57.4%): 193 dyspnea, 9 angina, 17 syncope, and 60 admission for heart failure. Syncope on effort persisted in 4 of 33 patients (12.1%) and at rest in 11 of 20 (55.0%; P<.001). Age, body mass index, previous admission for heart failure, and chronic obstructive pulmonary disease were independently related to persistence of symptoms. Over a median follow-up of 56 months in our cohort of 451 patients, 129 deaths were registered (28.6%), 40 of which were cardiovascular (8.9%). Age, chronic obstructive pulmonary disease, chronic kidney disease, atrial fibrillation, heart failure, and persistence of symptoms were independently associated with all-cause mortality. CONCLUSION: Symptoms attributed to SAS remain after intervention in a high proportion of patients, particularly dyspnea on effort and syncope at rest. The persistence of symptoms after intervention identifies patients with poor outcome.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Doença Pulmonar Obstrutiva Crônica , Humanos , Prognóstico , Síncope , Constrição Patológica , Dispneia/etiologia , Doença Pulmonar Obstrutiva Crônica/complicações , Medidas de Resultados Relatados pelo Paciente , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
17.
Am Heart J ; 270: 86-94, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38309610

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Ponte de Artéria Coronária , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
20.
Rev Esp Cardiol (Engl Ed) ; 77(2): 138-147, 2024 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37354942

RESUMO

INTRODUCTION AND OBJECTIVES: Catheter-directed therapy (CDT) for acute pulmonary embolism (PE) is an emerging therapy that combines heterogeneous techniques. The aim of the study was to provide a nationwide contemporary snapshot of clinical practice and CDT-related outcomes. METHODS: This Investigator-initiated multicenter registry aimed to include consecutive patients with intermediate-high risk (IHR) or high-risk (HR), acute PE eligible for CDT. The primary outcome of the study was in-hospital all-cause death. RESULTS: A total of 253 patients were included, of whom 93 (36.8%) had HR-PE, and 160 (63.2%) had IHR-PE with a mean age of 62.3±15.1 years. Local thrombolysis was performed in 70.8% and aspiration thrombectomy in 51.8%, with 23.3% of patients receiving both. However, aspiration thrombectomy was favored in the HR-PE cohort (80.6% vs 35%; P<.001). Only 51 patients (20.2%) underwent CDT with specific PE devices. The success rate for CDT was 90.9% (98.1% of IHR-PE patients vs 78.5% of HR-PE patients, P<.001). In-hospital mortality was 15.5%, and was highly concentrated in the HR-PE patients (37.6%) and significantly lower in IHR-PE patients (2.5%), P<.001. Long-term (24-month) mortality was 40.2% in HR-PE patients vs 8.2% in IHR-PE patients (P<.001). CONCLUSIONS: Despite the high success rate for CDT, in-hospital mortality in HR-PE is still high (37.6%) compared with very low IHR-PE mortality (2.5%).


Assuntos
Fibrinolíticos , Embolia Pulmonar , Humanos , Pessoa de Meia-Idade , Idoso , Fibrinolíticos/uso terapêutico , Terapia Trombolítica/métodos , Resultado do Tratamento , Embolia Pulmonar/terapia , Trombectomia/métodos , Catéteres , Sistema de Registros , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...