Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 96(21): 8342-8348, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38728056

RESUMO

In this study, we reported a selective impedimetric biosensor for the detection of A29 which is the target protein of the monkeypox virus (MPXV). The working principle of the biosensor relies on the interaction mechanism between A29, which is an internal membrane protein of MPXV, and the heparan sulfate receptor. For this purpose, after immobilizing heparan sulfate onto the gold screen-printed electrode surface, its interaction with A29 protein was monitored using electrochemical impedance spectroscopy. After the optimization of experimental parameters, the analytical characteristics of the developed MPVX immunosensor were examined. The developed immunosensor exhibited a linear detection range between 2.0 and 50 ng mL-1, with a detection limit of 2.08 ng mL-1 and a quantification limit of 6.28 ng mL-1. Furthermore, a relative standard deviation value of 2.82% was determined for 25 ng mL-1. Apart from that, sample application studies were also performed with the standard addition of A29 protein to 1:10 diluted real serum samples that were taken from healthy individuals, and very good recovery values were obtained.


Assuntos
Técnicas Eletroquímicas , Monkeypox virus , Humanos , Imunoensaio/métodos , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Limite de Detecção , Ouro/química , Eletrodos , Espectroscopia Dielétrica
2.
Diagn Microbiol Infect Dis ; 109(4): 116352, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38768547

RESUMO

In this article, a colorimetric biosensor for detection of Leishmania major surface protease (Gp63) antibody (anti-gp63) was developed by using gold nanoparticle (AuNP) as a color reagent. The dispersion or aggregation of AuNPs leads to a distinct and sensitive change in UV-vis spectra and solution color. For this purpose, kinetoplastid membrane protein-11 (KMP-11) was labeled with AuNPs surface directly. After that, Gp63 antibody was added in the KMP-11@AuNP solution and a color change from red/pink to purple/violet was observed. As a result, anti-gp63 solution diluted at a ratio of 1:640 can be detected with the developed colorimetric leishmania biosensor. The relative standard deviation value for 1:320 diluted anti-gp63 was calculated as 1.29 %. Furthermore, the linear range of the developed colorimetric biosensor was determined as 1:80 to 1:640. Moreover, developed Leishmania biosensor was applied for detection of leishmania parasite crude antigen and rabbit serum which were used as positive and negative samples respectively. As a result, the recovery values for the measurements of aforementioned samples were calculated as 95.3 % ± 0.02, 103.1 % ± 0.02, 96.2 % ± 0.01 and 95.5 % ± 0.03 for dilutions of 1:200, 1:160, 1:320 and 1:640 anti-gp63 solutions respectively.


Assuntos
Técnicas Biossensoriais , Colorimetria , Ouro , Leishmaniose , Nanopartículas Metálicas , Colorimetria/métodos , Técnicas Biossensoriais/métodos , Ouro/química , Nanopartículas Metálicas/química , Leishmaniose/diagnóstico , Animais , Coelhos , Humanos , Leishmania major/imunologia , Anticorpos Antiprotozoários/sangue , Sensibilidade e Especificidade , Antígenos de Protozoários/imunologia , Antígenos de Protozoários/análise , Metaloendopeptidases
3.
J Food Sci Technol ; 61(3): 585-595, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38327863

RESUMO

A facile electrochemical sensor based on carbon felt electrode (CFE) modified with gold nanoparticles decorated copper based metal organic framework (AuNPs@Cu-MOF) was achieved for the electrochemical sensing of L-Cysteine (L-Cys). For this purpose, AuNPs@Cu-MOF was synthesized and characterized. The electrochemical behaviors of L-Cys at plain and modified CFEs were investigated via cyclic voltammetry (CV). According CV results, AuNPs@Cu-MOF structure showed a catalytic effect on the oxidation of L-Cys as well as increasing the active electrode surface area by 206% compared to bare CFE. In addition, the pH effect on electrochemical determination of L-Cys at AuNPs@Cu-MOF/CFE was widely examined, and it was determined that the best oxidation peak current of L-Cys was obtained in pH 5 acetate buffer. Moreover, a linear detection range of 30-400 µM for L-Cys with a limit of detection value of 2.21 µM (n = 3) was achieved with the proposed electrochemical sensor. The developed L-Cys sensor was also applied for L-Cys detection in various milk samples and acceptable recovery values were obtained ranging from 100.05 to 108.45%. Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-023-05866-1.

4.
Biosensors (Basel) ; 13(2)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36831942

RESUMO

H1N1 is a kind of influenza A virus that causes serious health issues throughout the world. Its symptoms are more serious than seasonal flu and can sometimes be lethal. For this reason, rapid, accurate, and effective diagnostic tests are needed. In this study, an electrochemical immunosensor for the sensitive, selective, and practical detection of the H1N1 virus was developed. The sensor platform included multi-walled carbon nanotube gold-platinum (MWCNT-Au-Pt) hybrid nanomaterial and anti-hemagglutinin (anti-H1) monoclonal antibody. For the construction of this biosensor, a gold screen-printed electrode (AuSPE) was used as a transducer. Firstly, AuSPE was modified with MWCNT-Au-Pt hybrid nanomaterial via drop casting. Anti-H1 antibody was immobilized onto the electrode surface after the modification process with cysteamine was applied. Then, the effect of the interaction time with cysteamine for surface modification was investigated. Following that, the experimental parameters, such as the amount of hybrid nanomaterial and the concentration of anti-H1 were optimized. Under the optimized conditions, the analytical characteristics of the developed electrochemical immunosensor were investigated for the H1N1 virus by using electrochemical impedance spectroscopy. As a result, a linear range was obtained between 2.5-25.0 µg/mL with a limit of the detection value of 3.54 µg/mL. The relative standard deviation value for 20 µg/mL of the H1N1 virus was also calculated and found as 0.45% (n = 3). In order to determine the selectivity of the developed anti-H1-based electrochemical influenza A immunosensor, the response of this system towards the H3N2 virus was investigated. The matrix effect was also investigated by using synthetic saliva supplemented with H1N1 virus.


Assuntos
Técnicas Biossensoriais , Vírus da Influenza A Subtipo H1N1 , Vírus da Influenza A , Nanopartículas Metálicas , Nanocompostos , Imunoensaio , Vírus da Influenza A Subtipo H3N2 , Técnicas Biossensoriais/métodos , Cisteamina , Nanocompostos/química , Anticorpos , Eletrodos , Ouro/química , Técnicas Eletroquímicas , Limite de Detecção , Nanopartículas Metálicas/química
5.
Talanta ; 254: 124166, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36493566

RESUMO

A facile amperometric biosensor that included oxidase mimicking Co/2Fe metal-organic framework (MOF) for sialic acid (SA) detection was prepared. Amperometric SA biosensor was constructed on a gold screen-printed electrode via immobilization of Co/2Fe MOF and N-acetylneuraminic Acid Aldolase (NANA-Aldolase) enzyme, respectively. NANA-Aldolase enzyme converts free SA into pyruvate and N-acetyl-d-mannosamine. After this conversion, oxidase mimicking Co/2Fe bimetallic MOF converts pyruvate into acetylphosphate and O2 into H2O2. Investigation of analytical characteristics resulted with the linear range of 0.02 mM-1.00 mM of SA concentration with limit of detection value of 0.026 mM. Sample application studies with developed SA biosensor were carried out with GD3 ganglioside and HeLa cancer cell lines which have high SA concentrations while A549 cell lines were also used as control group. Before detecting free SA, the bound SA was freed from SA sources where every step was monitored via electron impedance spectroscopy. Then, free SA was successfully detected with the amperometric SA biosensor and as a result, more practical and accurate system was developed.


Assuntos
Técnicas Biossensoriais , Estruturas Metalorgânicas , Oxirredutases , Ácido N-Acetilneuramínico , Enzimas Imobilizadas/química , Peróxido de Hidrogênio/química , Técnicas Biossensoriais/métodos , Ácido Pirúvico , Limite de Detecção , Eletrodos
6.
Analyst ; 147(1): 130-138, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34859794

RESUMO

In this study, an electrochemical approach for the determination of coronavirus disease (COVID-19) was developed. The biosensor system relied on the spike protein (S-protein) based infection mechanism of the virus and included separate interactions of receptors like angiotensin-converting enzyme 2 (ACE2) and CD147. After the optimization of experimental parameters, the analytical characteristics of both receptors ACE2 and CD147 were investigated. For ACE2 receptor, the linear detection ranges of the S-protein were found in the range of 700 ng mL-1 to 1500 ng mL-1 and from 1500 ng mL-1 to 7000 ng mL-1 with a limit of detection (LOD) value of 299.30 ng mL-1. Meanwhile, for CD147 receptor the linear range was in the range of 500 ng mL-1 to 5000 ng mL-1 with a LOD value of 38.99 ng mL-1. After the examination of analytical characteristics, the developed electrochemical approach was applied for severe acute respiratory syndrome coronavirus 2 samples and the obtained results were validated with real time polymerase chain reaction method.


Assuntos
COVID-19 , SARS-CoV-2 , Testes Diagnósticos de Rotina , Humanos
7.
Mikrochim Acta ; 188(10): 335, 2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34505191

RESUMO

A practical colorimetric assay was developed for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). For this purpose, magnetic γ Fe2O3 nanoparticles were synthesized and used as a peroxidase-like mimic activity molecule. In the presence of γ Fe2O3 nanoparticles, the color change of H2O2 included 3,3',5,5'-tetramethylbenzidine was monitored at the wavelength of 654 nm when spike protein interacted with angiotensin-converting enzyme 2 receptor. This oxidation-reduction reaction was examined both spectroscopically and by using electrochemical techniques. The experimental parameters were optimized and the analytical characteristics investigated. The developed assay was applied to real SARS-CoV-2 samples, and very good results that were in accordance with the real time polymerase chain reaction were obtained.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Colorimetria/métodos , Nanopartículas Magnéticas de Óxido de Ferro/química , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/química , Enzima de Conversão de Angiotensina 2/metabolismo , Benzidinas/química , Técnicas Biossensoriais/métodos , Teste para COVID-19/instrumentação , Catálise , Compostos Cromogênicos/química , Cisteína/química , Humanos , Peróxido de Hidrogênio/química , Limite de Detecção , Nasofaringe/virologia , Orofaringe/virologia , Oxirredução , Peroxidase/química , Glicoproteína da Espícula de Coronavírus/metabolismo
8.
Mater Sci Eng C Mater Biol Appl ; 101: 88-91, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31029367

RESUMO

Cancer Biomarkers are important biological molecules which provide early detection, diagnosis and classification of cancer cells. In this work, nanoparticle tags with different redox potentials have been used as an electrochemical coding technology for the simultaneous detection of carcinoembryonic antigen (CEA), vascular endothelial growth factor (VEGF) and α-fetoprotein (AFP) biomarkers. As far as we know, this is the only work that covers the simultaneous detections of these biomarkers. For this purpose, basically, an electrochemical sandwich immunosensor, which was fabricated from carbon screen printed electrode, was utilized as a diagnostic platform. As nanoparticle tags, PbAu@É£Fe2O3, CuAu@É£Fe2O3 and ZnAu@É£Fe2O3 hybrid nanolabels were synthesized and used for labelling anti-CEA, anti-VEGF and anti-AFP, respectively. By monitoring differential pulse voltammetric oxidation peaks of labeling metals (Pb, Cu, Zn), CEA, VEGF and AFP biomarkers were detected at the same time.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/métodos , Antígeno Carcinoembrionário/análise , Imunoensaio/métodos , Fator A de Crescimento do Endotélio Vascular/análise , alfa-Fetoproteínas/análise , Anticorpos/metabolismo , Espectroscopia Dielétrica , Técnicas Eletroquímicas , Humanos , Nanopartículas/química , Oxirredução
9.
Mikrochim Acta ; 186(3): 196, 2019 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-30788595

RESUMO

Metal-organic frameworks (MOFs) are porous coordination polymers (CP) produced by metal-based nodes and multitopic organic ligands. Based on their porous and microcrystalline powder structures, they have initially been used for storage, catalysis and separation. Then, because of their advantageous properties like ease of the tailoring, they also have been applied in areas like chemical sensing, biological applications, etc. The CPs were combined with molecules such as organic dyes, small biomolecules, nanomaterials like nanoparticles, nanowires, nanofibers and polymers and as a result, composite MOFs have been produced. By this way, better mechanical stability, conductivity, and catalytic performance were obtained. This review (with 135 refs.) summarizes the progress made in the past years in the field of electrochemical and optical sensing based on the use of MOFs. Following an introduction into the field, large sections cover MOF based sensors exploiting (a) carbon nanomaterials (with subsections on carbon nanotubes, graphene and its derivatives), (b) metal/metal oxide MOFs; including gold, silver, copper and/or copper oxide nanoparticle and other metal/MOF composites. Enzyme mimicking MOFs are discussed next. In this context, after the brief information about focused MOFs, the nanomaterial/MOF composites were discussed and related examples were presented. Graphical abstract MOF structures in Sensing Systems.

10.
Biosens Bioelectron ; 107: 170-177, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29455027

RESUMO

Influenza is a viral infectious disease considered as a source of many health problems and enormous socioeconomic disruptions. Conventional methods are inadequate for in-field detection of the virus and generally suffer from being laborious and time-consuming. Thus, studies aiming to develop effective alternatives to conventional methods are urgently needed. In this work, we developed an approach for the isolation and detection of influenza A virus subtype H9N2. For this aim, two specific influenza receptors were used. The first, anti-matrix protein 2 (M2) antibody, was attached to iron magnetic nanoparticles (MNPs) and used for the isolation of the virus from allantoic fluid. The second biomolecule, Fetuin A, was attached to an electrochemical detectable label, gold nanoparticles (AuNPs), and used to detect the virus tacking advantage from fetuin-hemagglutinin interaction. The MNP-Influenza virus-AuNP formed complex was isolated and treated by an acid solution then the collected gold nanoparticles were deposited onto a screen printed carbon electrode. AuNPs catalyzes the hydrogen ions reduction in acidic medium while applying an appropriate potential, and the generated current signal was proportional to the virus titer. This approach allows the rapid detection of influenza virus A/H9N2 at a less than 16 HAU titer.


Assuntos
Técnicas Biossensoriais/métodos , Carbono/química , Ouro/química , Vírus da Influenza A Subtipo H9N2/isolamento & purificação , Influenza Aviária/diagnóstico , Nanopartículas de Magnetita/química , Animais , Anticorpos Imobilizados/química , Catálise , Galinhas/virologia , Ovos/virologia , Glicoproteínas de Hemaglutininação de Vírus da Influenza/análise , Glicoproteínas de Hemaglutininação de Vírus da Influenza/isolamento & purificação , Imunoensaio/métodos , Influenza Aviária/virologia , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Microeletrodos
11.
Analyst ; 143(1): 150-156, 2017 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-29134205

RESUMO

An effective electrochemical influenza A biosensor based on a graphene-gold (Au) hybrid nanocomposite modified Au-screen printed electrode has been developed. The working principle of the developed biosensor relies on the measurement of neuraminidase (N) activity. After the optimization of experimental parameters like the effect of bovine serum albumin addition and immobilization times of fetuin A and PNA lectin, the analytical characteristics of the influenza A biosensor were investigated. As a result, a linear range between 10-8 U mL-1 and 10-1 U mL-1 was found with a relative standard deviation value of 3.23% (for 10-5 U mL-1 of N, n:3) and a limit of detection value of 10-8 U mL-1 N. The developed biosensor was applied for real influenza virus A (H9N2) detection and very successful results were obtained.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Vírus da Influenza A Subtipo H9N2/isolamento & purificação , Nanocompostos , Neuraminidase/metabolismo , Ouro , Grafite , Vírus da Influenza A Subtipo H9N2/enzimologia
12.
Anal Chem ; 88(12): 6151-3, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27281347

RESUMO

Neuroaminidase (NA) enzyme is a kind of glycoprotein that is found on the influenza A virus. During infection, NA is important for the release of influenza virions from the host cell surface together with viral aggregates. It may also be involved in targeting the virus to respiratory epithelial cells. In this study, a model electrochemical influenza A viral biosensor in which receptor-binding properties have been based on NA was developed for the first time. The biosensor's working principle is based on monitoring the interactions between fetuin A and NA enzyme. The assay was monitored step by step by using electrochemical impedance spectroscopy.


Assuntos
Técnicas Biossensoriais , Espectroscopia Dielétrica , Vírus da Influenza A/enzimologia , Neuraminidase/metabolismo , Eletrodos , Modelos Biológicos , Aglutinina de Amendoim/metabolismo , Ligação Proteica , alfa-2-Glicoproteína-HS/metabolismo
13.
Artif Cells Nanomed Biotechnol ; 44(3): 971-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25697045

RESUMO

A biosensor was developed using glutathione peroxidase (GSH-Px) as the enzyme. Firstly, platinum (Pt) nanoparticles were deposited onto a glassy carbon paste electrode (GCPE), and then GSH-Px was immobilized by means of gelatin that was then crosslinked with glutaraldehyde. The measurement was based on the electrochemical oxidation of GSH to its disulfide form in the presence of hydrogen peroxide. The linear range was found to be between 10 and 250 µM, with a correlation coefficient of R(2) = 0.9968. The R.S.D value for 25 µM GSH (n = 6) was calculated as 2.92%. Finally, the proposed biosensor was used to analyze GSH in a synthetically prepared plasma sample, and a promising recovery value was obtained.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Glutationa/análise , Carbono/química , Peróxido de Hidrogênio/química , Oxirredução
14.
Talanta ; 129: 523-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25127628

RESUMO

Glassy carbon paste electrode (GCPE) was modified with graphene platinum hybrid nanoparticle (Gr-Pt hybrid NP) and used as a transducer for label and indicator free electrochemical genosensor. 22 mer oligonucleotides representing Escherichia coli bacteria were used as a model case. As far as it is known, this study is the first study where Gr-Pt hybrid NP was incorporated into GCPE and used for genosensor transducer. The extent of hybridization was determined by using differential pulse voltammetric signals of guanin oxidation. After the optimization of experimental parameters, analytical characteristics were investigated. The linear range was found between 1.5×10(-7) and 2.25×10(-6) M with the equation of y=1.6566x-2.6161 and R(2) of 0.9959. RSD and LOD were calculated as 4.2% (n=6) and 1.12×10(-9) M respectively.


Assuntos
Eletroquímica/métodos , Grafite/química , Nanopartículas/química , Hibridização de Ácido Nucleico/métodos , Platina/química , Escherichia coli/química , Guanina/química , Limite de Detecção , Nanotecnologia/métodos , Oligonucleotídeos/química , Oxigênio/química
15.
Artif Cells Nanomed Biotechnol ; 41(1): 8-12, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22757635

RESUMO

A composite electrode was prepared by modifying glassy carbon micro particles with gold nanoparticles and glucose oxidase enzyme for glucose detection. In terms of analytical characteristics, a linearity was obtained in the concentration range between 50.0 and 1000.0 µM with equation of y = 0.0015x + 0.2336 with the correlation coefficient of R(2) = 0.9801. R.S.D. value was calculated for 400 µM glucose (n = 6) and found to be 4.89%. LOD and LOQ values were also calculated and revealed to be 52.9 µM and 176.3 µM, respectively. The developed system was also applied for detection of glucose in four types of alcoholic beverages.


Assuntos
Bebidas Alcoólicas/análise , Técnicas Biossensoriais/métodos , Glucose/análise , Nanopartículas Metálicas/química , Técnicas Biossensoriais/normas , Carbono , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Ouro , Concentração de Íons de Hidrogênio
16.
Nanoscale Res Lett ; 5(5): 846-52, 2010 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-20672081

RESUMO

The electroanalytic performances of glassy carbon paste electrode (GCPE), multi-walled carbon nanotube (MWCNT)-GCPE and double-walled carbon nanotube (DWCNT)-GCPE, which include HNO3 washed/unwashed materials, were compared by monitoring cyclic voltammograms of potassium ferricyanide and catechol. Electrodes were prepared by introducing proper amount of DWCNT and MWCNT into GCPE. First untreated materials (DWCNT, MWCNT, GC µ-particles) were used in the electrodes and then HNO3-treated materials were utilized for comparing difference in electrochemical performances. The effect of treatment procedure was also examined by applying Raman spectroscopy to treated and untreated materials. Moreover, TEM images were obtained for further investigation of MWCNT and DWCNT.

17.
Anal Chim Acta ; 598(1): 143-6, 2007 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-17693318

RESUMO

A biosensing system based on alpha-glucosidase (AG) activity was developed by using bismuth film modified glassy carbon electrode (BiFE). AG enzyme was immobilized on the BiFE by means of gelatin membrane and the activity was measured by the following of liberated 4-nitrophenol from the 4-nitrophenyl-alpha-D-glucopyranoside (PNPGP) which is the synthetic substrate of the enzyme at the working potential of -950 mV. The proposed system was used as an AG based biosensing system. Experimental data showed that the response current of 4-nitrophenol obtained at the BiFE was linear in concentration range between 0.033 and 0.33 mM of PNPGP. Before examining the analytical characteristics, pH optimization of the AG-biosensor was also performed. Furthermore, the proposed method was applied to analyze two different AG inhibitors (Amaryl and Acorbose) which are important in Noninsulin-dependent diabetes mellitus (NIDDM).


Assuntos
Bismuto/química , Inibidores Enzimáticos/análise , Enzimas Imobilizadas/química , Nitrofenóis/química , alfa-Glucosidases/química , Técnicas Biossensoriais , Eletroquímica , Eletrodos , Inibidores Enzimáticos/farmacologia , Inibidores de Glicosídeo Hidrolases , Concentração de Íons de Hidrogênio , Compostos de Sulfonilureia/análise , Compostos de Sulfonilureia/farmacologia , alfa-Glucosidases/metabolismo
18.
Talanta ; 74(3): 434-9, 2007 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371660

RESUMO

A composite electrode was prepared by modifying glassy carbon microparticles with gold nanoparticles (Au-nps) and xanthine oxidase enzyme (XOD) for xanthine (X) and hypoxanthine (Hx) detection. After the optimization of the system for X, the biosensor was characterized for X and Hx. A linearity was obtained in the concentration range between 5.00 x 10(-7) and 1.00 x 10(-5) M for X with equation of y=0.24 x + 0.712 and 5.00 x 10(-6) to 1.50 x 10(-4) M for Hx, with equation of y = 0.014 x + 0.575, respectively. Obtained results were compared to X and/or Hx biosensors including/not including Au-np in the structure. The developed system was also applied for detection of Hx in canned tuna fish sample and very promising results were obtained.


Assuntos
Técnicas Biossensoriais/instrumentação , Carbono/química , Ouro/química , Hipoxantina/análise , Nanopartículas Metálicas/química , Xantina Oxidase/metabolismo , Xantina/análise , Eletroquímica , Eletrodos , Vidro/química , Concentração de Íons de Hidrogênio , Modelos Lineares , Microscopia Eletrônica de Varredura , Nanocompostos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...