Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 73(13): 2911-9, 2001 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-11467535

RESUMO

A model is presented describing the effects of dead time and mass bias correction factor uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision using inductively coupled plasma mass spectrometry (ICPMS) with a single collector. Noise spectral analysis is exploited to enable estimation of the flicker noise parameters. For the instrument used, the flicker noise component exhibited a fairly weak frequency (t) dependence (is proportional to f -0.33+/-0.12), but was directly proportional to the total number of counts, Q. As white noise, determined by counting statistics, is given by Q0.5, the isotope ratio measurement uncertainties will actually cease to improve when Q exceeds a certain threshold. This would suggest that flicker noise could become the limiting factor for the precision with which isotope ratios can be determined by ICPMS. However, under most experimental conditions, uncertainties associated with mass discrimination and dead time correction factors are decisive. For ratios up to approximately 22 (115In/113In), optimum major isotope count rates are generally below 0.3 MHz, for which precision in the mass discrimination factor is limiting. The model derived could be used as a starting point for determining optimum conditions and understanding the limitations of single-collector ICPMS for precise isotope ratio measurements.

2.
J Environ Monit ; 1(3): 211-7, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11529105

RESUMO

A comparison of two systems for the quantitation of metal-humic complexes and free metal ions, consisting of the separation by coupled ion exchange columns followed by detection by inductively coupled plasma mass spectrometry or cold vapour atomic fluorescence spectrometry, is presented. The systems evaluated comprised the serially coupled anion and cation exchangers, Sephadex A-25/Chelex 100 and Dowex 1X8/Chelamine Metalfix. Separation and preconcentration of the species studied were accomplished with both systems, elution being carried out using 2 M HNO3. Total concentrations, metal-humic complex fractions and free metal ion fractions of Al, Ba, Cd, Co, Cu, Fe, Hg, Mn, Pb, Sr, U and Zn in nine natural waters were determined. Statistical evaluation of the data from the two cation exchange materials, including results for additional elements, showed better precision (for Al, Ba, Cr, Cu and Mo) and higher recoveries (Al, Ba, Cd, Fe, Sr and Zn) for Chelex 100 than Chelamine Metalfix for free metal ions. On the other hand, Chelamine Metalfix recovered a significantly greater amount of Ni. The amounts of metal-humic complexes were compared with modelled distributions of these species, and one advantage of the preferred Sephadex A-25/Chelex 100 system is that the elements studied are all correctly classified with respect to their binding strengths to humic substances, which is not the case with the Dowex 1X8/Chelamine Metalfix pair. With the preferred system, metal-humic complexes can be reliably determined, as indicated by the results of equilibrium speciation modelling. However, comparison with the total concentrations showed statistically significant, non-quantitative recoveries of Al, Cu, Hg, Mn, U and Zn from some samples. Thus a combination of speciation and total concentration measurements is required to obtain a complete representation of the distribution of trace elements in natural waters.


Assuntos
Substâncias Húmicas/química , Metais Pesados/análise , Poluentes da Água/análise , Monitoramento Ambiental/métodos , Metais Pesados/química , Sensibilidade e Especificidade , Análise Espectral/métodos , Oligoelementos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...