Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 408
Filtrar
1.
Eur J Radiol ; 177: 111595, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38970994

RESUMO

PURPOSE: CT perfusion (CTP) is a valuable tool in suspected acute ischemic stroke. A substantial variability of the delay between contrast injection and bolus arrival in the brain is conceivable. We investigated the distribution of the peak positions of the concentration time curves measured in an artery (arterial input function, AIF) and - in cases with ischemia - also measured in the penumbra. METHODS: We report on 2624 perfusion scans (52 % female, mean age 72.2 ± 14.4 years) with stroke present in 1636 cases. From the attenuation time curves of the AIF and the penumbra, we calculated the respective bolus peak positions and investigated the distribution of the peak positions. Further, we analyzed the bolus peak positions for associations with age. RESULTS: The bolus peaked significantly later in older patients, both in the AIF and in the penumbra (all p < 0.001). In the whole cohort, we found a significant association of age with the bolus peak position of the AIF (ρ = 0.334; p < 0.001). In patients with stroke, age was also associated to the peak position of the AIF (ρ = 0.305; p < 0.001), and the penumbra (ρ = 0.246, p < 0.001). However, a substantial range of peak positions of the AIF and penumbra was noted across all age ranges. CONCLUSIONS: This study revealed a strong age-dependency of the contrast bolus arrival in both healthy and ischemic tissue. This variability makes non-uniform sampling schemes, which have been suggested to reduce radiation dose, problematic, as they might not always optimally capture the bolus in all cases.

2.
Sci Rep ; 14(1): 14664, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918570

RESUMO

Aim of this study was to analyse the associations of cardiovascular health and adrenal gland volume as a rather new imaging biomarker of chronic hypothalamic-pituitary-adrenal (HPA) axis activation. The study population originates from the KORA population-based cross-sectional prospective cohort. 400 participants without known cardiovascular disease underwent a whole-body MRI. Manual segmentation of adrenal glands was performed on VIBE-Dixon gradient-echo sequence. MRI based evaluation of cardiac parameters was achieved semi-automatically. Cardiometabolic risk factors were obtained through standardized interviews and medical examination. Univariate and multivariate associations were derived. Bi-directional causal mediation analysis was performed. 351 participants were eligible for analysis (56 ± 9.1 years, male 58.7%). In multivariate analysis, significant associations were observed between adrenal gland volume and hypertension (outcome hypertension: Odds Ratio = 1.11, 95% CI [1.01, 1.21], p = 0.028), left ventricular remodelling index (LVRI) (outcome LVRI: ß = 0.01, 95% CI [0.00, 0.02], p = 0.011), and left ventricular (LV) wall thickness (outcome LV wall thickness: ß = 0.06, 95% CI [0.02, 0.09], p = 0.005). In bi-directional causal mediation analysis adrenal gland volume had a borderline significant mediating effect on the association between hypertension and LVRI (p = 0.052) as well as wall thickness (p = 0.054). MRI-based assessment of adrenal gland enlargement is associated with hypertension and LV remodelling. Adrenal gland volume may serve as an indirect cardiovascular imaging biomarker.


Assuntos
Glândulas Suprarrenais , Doenças Cardiovasculares , Imageamento por Ressonância Magnética , Humanos , Masculino , Pessoa de Meia-Idade , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/patologia , Imageamento por Ressonância Magnética/métodos , Feminino , Doenças Cardiovasculares/diagnóstico por imagem , Estudos Transversais , Idoso , Estudos Prospectivos , Hipertensão/diagnóstico por imagem , Hipertensão/patologia , Remodelação Ventricular , Tamanho do Órgão , Sistema Hipotálamo-Hipofisário/diagnóstico por imagem , Sistema Hipófise-Suprarrenal/diagnóstico por imagem
3.
Insights Imaging ; 15(1): 124, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825600

RESUMO

OBJECTIVES: Achieving a consensus on a definition for different aspects of radiomics workflows to support their translation into clinical usage. Furthermore, to assess the perspective of experts on important challenges for a successful clinical workflow implementation. MATERIALS AND METHODS: The consensus was achieved by a multi-stage process. Stage 1 comprised a definition screening, a retrospective analysis with semantic mapping of terms found in 22 workflow definitions, and the compilation of an initial baseline definition. Stages 2 and 3 consisted of a Delphi process with over 45 experts hailing from sites participating in the German Research Foundation (DFG) Priority Program 2177. Stage 2 aimed to achieve a broad consensus for a definition proposal, while stage 3 identified the importance of translational challenges. RESULTS: Workflow definitions from 22 publications (published 2012-2020) were analyzed. Sixty-nine definition terms were extracted, mapped, and semantic ambiguities (e.g., homonymous and synonymous terms) were identified and resolved. The consensus definition was developed via a Delphi process. The final definition comprising seven phases and 37 aspects reached a high overall consensus (> 89% of experts "agree" or "strongly agree"). Two aspects reached no strong consensus. In addition, the Delphi process identified and characterized from the participating experts' perspective the ten most important challenges in radiomics workflows. CONCLUSION: To overcome semantic inconsistencies between existing definitions and offer a well-defined, broad, referenceable terminology, a consensus workflow definition for radiomics-based setups and a terms mapping to existing literature was compiled. Moreover, the most relevant challenges towards clinical application were characterized. CRITICAL RELEVANCE STATEMENT: Lack of standardization represents one major obstacle to successful clinical translation of radiomics. Here, we report a consensus workflow definition on different aspects of radiomics studies and highlight important challenges to advance the clinical adoption of radiomics. KEY POINTS: Published radiomics workflow terminologies are inconsistent, hindering standardization and translation. A consensus radiomics workflow definition proposal with high agreement was developed. Publicly available result resources for further exploitation by the scientific community.

4.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
6.
Skeletal Radiol ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940940

RESUMO

OBJECTIVE: Fatty infiltration of skeletal muscle (Myosteatosis) is associated with increased frailty, decreased muscle and mobility function, which seems fairly prevalent in multiple myeloma (MM) patients. This study aimed to determine the prognostic value of myosteatosis assessed by CT for progression-free survival (PFS) and overall survival (OS). MATERIALS AND METHODS: This IRB-approved cohort study included patients with newly diagnosed MM who were treated at a single university hospital and received CT at baseline. Geriatric assessment was performed via International Myeloma Working Group frailty score and Revised Myeloma Comorbidity Index. Myosteatosis was determined through measurement of paravertebral muscle radiodensity. Statistical analyses included uni- and multivariable Cox proportional hazard models and the Kaplan-Meier-method. RESULTS: A total of 226 newly diagnosed MM patients (median age: 65 years [range: 29-89], 63% males, mean BMI: 25 [14-42]) were analyzed. The prevalence of myosteatosis was 51%. Muscle radiodensity was significantly decreased in individuals with International Staging System stage III vs. I (p < 0.001), indicating higher fatty muscle infiltration in patients with advanced disease. Both PFS and OS were significantly decreased in patients with myosteatosis (PFS: median 32.0 months (95% CI 20.5.5-42.2) vs. 66.4 months without myosteatosis (95% CI 42.5-not reached), p < .001); OS: median 58.6 (95% CI 51.3-90.2) vs. not reached, p < .001). Myosteatosis remained an independent predictor of OS in multivariable analyses (HR: 1.98; 95%-CI: 1.20-3.27). CONCLUSION: Myosteatosis seems fairly prevalent in patients with newly diagnosed MM and associated with impaired overall survival. Prospective clinical trials are required to better understand the role of myosteatosis in MM patients.

7.
Eur Radiol Exp ; 8(1): 60, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38755410

RESUMO

BACKGROUND: We investigated the potential of an imaging-aware GPT-4-based chatbot in providing diagnoses based on imaging descriptions of abdominal pathologies. METHODS: Utilizing zero-shot learning via the LlamaIndex framework, GPT-4 was enhanced using the 96 documents from the Radiographics Top 10 Reading List on gastrointestinal imaging, creating a gastrointestinal imaging-aware chatbot (GIA-CB). To assess its diagnostic capability, 50 cases on a variety of abdominal pathologies were created, comprising radiological findings in fluoroscopy, MRI, and CT. We compared the GIA-CB to the generic GPT-4 chatbot (g-CB) in providing the primary and 2 additional differential diagnoses, using interpretations from senior-level radiologists as ground truth. The trustworthiness of the GIA-CB was evaluated by investigating the source documents as provided by the knowledge-retrieval mechanism. Mann-Whitney U test was employed. RESULTS: The GIA-CB demonstrated a high capability to identify the most appropriate differential diagnosis in 39/50 cases (78%), significantly surpassing the g-CB in 27/50 cases (54%) (p = 0.006). Notably, the GIA-CB offered the primary differential in the top 3 differential diagnoses in 45/50 cases (90%) versus g-CB with 37/50 cases (74%) (p = 0.022) and always with appropriate explanations. The median response time was 29.8 s for GIA-CB and 15.7 s for g-CB, and the mean cost per case was $0.15 and $0.02, respectively. CONCLUSIONS: The GIA-CB not only provided an accurate diagnosis for gastrointestinal pathologies, but also direct access to source documents, providing insight into the decision-making process, a step towards trustworthy and explainable AI. Integrating context-specific data into AI models can support evidence-based clinical decision-making. RELEVANCE STATEMENT: A context-aware GPT-4 chatbot demonstrates high accuracy in providing differential diagnoses based on imaging descriptions, surpassing the generic GPT-4. It provided formulated rationale and source excerpts supporting the diagnoses, thus enhancing trustworthy decision-support. KEY POINTS: • Knowledge retrieval enhances differential diagnoses in a gastrointestinal imaging-aware chatbot (GIA-CB). • GIA-CB outperformed the generic counterpart, providing formulated rationale and source excerpts. • GIA-CB has the potential to pave the way for AI-assisted decision support systems.


Assuntos
Estudo de Prova de Conceito , Humanos , Diagnóstico Diferencial , Gastroenteropatias/diagnóstico por imagem
8.
Clin Exp Med ; 24(1): 103, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758248

RESUMO

COVID-19 vaccination has been shown to prevent and reduce the severity of COVID-19 disease. The aim of this study was to explore the cardioprotective effect of COVID-19 vaccination in hospitalized COVID-19 patients. In this retrospective, single-center cohort study, we included hospitalized COVID-19 patients with confirmed vaccination status from July 2021 to February 2022. We assessed outcomes such as acute cardiac events and cardiac biomarker levels through clinical and laboratory data. Our analysis covered 167 patients (69% male, mean age 58 years, 42% being fully vaccinated). After adjustment for confounders, vaccinated hospitalized COVID-19 patients displayed a reduced relative risk for acute cardiac events (RR: 0.33, 95% CI [0.07; 0.75]) and showed diminished troponin T levels (Cohen's d: - 0.52, 95% CI [- 1.01; - 0.14]), compared to their non-vaccinated peers. Type 2 diabetes (OR: 2.99, 95% CI [1.22; 7.35]) and existing cardiac diseases (OR: 4.31, 95% CI [1.83; 10.74]) were identified as significant risk factors for the emergence of acute cardiac events. Our findings suggest that COVID-19 vaccination may confer both direct and indirect cardioprotective effects in hospitalized COVID-19 patients.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Hospitalização , SARS-CoV-2 , Humanos , COVID-19/prevenção & controle , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Vacinas contra COVID-19/administração & dosagem , Vacinas contra COVID-19/imunologia , Idoso , Hospitalização/estatística & dados numéricos , SARS-CoV-2/imunologia , Vacinação , Cardiopatias/prevenção & controle , Fatores de Risco , Adulto , Troponina T/sangue
10.
JCO Clin Cancer Inform ; 8: e2300231, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38588476

RESUMO

PURPOSE: Body composition (BC) may play a role in outcome prognostication in patients with gastroesophageal adenocarcinoma (GEAC). Artificial intelligence provides new possibilities to opportunistically quantify BC from computed tomography (CT) scans. We developed a deep learning (DL) model for fully automatic BC quantification on routine staging CTs and determined its prognostic role in a clinical cohort of patients with GEAC. MATERIALS AND METHODS: We developed and tested a DL model to quantify BC measures defined as subcutaneous and visceral adipose tissue (VAT) and skeletal muscle on routine CT and investigated their prognostic value in a cohort of patients with GEAC using baseline, 3-6-month, and 6-12-month postoperative CTs. Primary outcome was all-cause mortality, and secondary outcome was disease-free survival (DFS). Cox regression assessed the association between (1) BC at baseline and mortality and (2) the decrease in BC between baseline and follow-up scans and mortality/DFS. RESULTS: Model performance was high with Dice coefficients ≥0.94 ± 0.06. Among 299 patients with GEAC (age 63.0 ± 10.7 years; 19.4% female), 140 deaths (47%) occurred over a median follow-up of 31.3 months. At baseline, no BC measure was associated with DFS. Only a substantial decrease in VAT >70% after a 6- to 12-month follow-up was associated with mortality (hazard ratio [HR], 1.99 [95% CI, 1.18 to 3.34]; P = .009) and DFS (HR, 1.73 [95% CI, 1.01 to 2.95]; P = .045) independent of age, sex, BMI, Union for International Cancer Control stage, histologic grading, resection status, neoadjuvant therapy, and time between surgery and follow-up CT. CONCLUSION: DL enables opportunistic estimation of BC from routine staging CT to quantify prognostic information. In patients with GEAC, only a substantial decrease of VAT 6-12 months postsurgery was an independent predictor for DFS beyond traditional risk factors, which may help to identify individuals at high risk who go otherwise unnoticed.


Assuntos
Adenocarcinoma , Aprendizado Profundo , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Inteligência Artificial , Prognóstico , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Composição Corporal
11.
Radiol Med ; 129(6): 890-900, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38689182

RESUMO

PURPOSE: Artifacts caused by metallic implants remain a challenge in computed tomography (CT). We investigated the impact of photon-counting detector computed tomography (PCD-CT) for artifact reduction in patients with orthopedic implants with respect to image quality and diagnostic confidence using different artifact reduction approaches. MATERIAL AND METHODS: In this prospective study, consecutive patients with orthopedic implants underwent PCD-CT imaging of the implant area. Four series were reconstructed for each patient (clinical standard reconstruction [PCD-CTStd], monoenergetic images at 140 keV [PCD-CT140keV], iterative metal artifact reduction (iMAR) corrected [PCD-CTiMAR], combination of iMAR and 140 keV monoenergetic [PCD-CT140keV+iMAR]). Subsequently, three radiologists evaluated the reconstructions in a random and blinded manner for image quality, artifact severity, anatomy delineation (adjacent and distant), and diagnostic confidence using a 5-point Likert scale (5 = excellent). In addition, the coefficient of variation [CV] and the relative quantitative artifact reduction potential were obtained as objective measures. RESULTS: We enrolled 39 patients with a mean age of 67.3 ± 13.2 years (51%; n = 20 male) and a mean BMI of 26.1 ± 4 kg/m2. All image quality measures and diagnostic confidence were significantly higher for the iMAR vs. non-iMAR reconstructions (all p < 0.001). No significant effect of the different artifact reduction approaches on CV was observed (p = 0.26). The quantitative analysis indicated the most effective artifact reduction for the iMAR reconstructions, which was higher than PCD-CT140keV (p < 0.001). CONCLUSION: PCD-CT allows for effective metal artifact reduction in patients with orthopedic implants, resulting in superior image quality and diagnostic confidence with the potential to improve patient management and clinical decision making.


Assuntos
Artefatos , Metais , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Próteses e Implantes , Idoso de 80 Anos ou mais , Fótons , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
12.
J Cardiothorac Surg ; 19(1): 184, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582893

RESUMO

The occurrence of ectopic pancreas in the mediastinum is rare. Herein, we report a 22-year-old female who presented with right shoulder pain, dysphagia, fever and headaches. Chest computer tomography revealed a mass in the posterior mediastinum with accompanying signs of acute mediastinitis. Needle biopsy and fine-needle aspiration revealed ectopic gastral tissue and ectopic pancreas tissue, respectively. Surgical resection was attempted due to recurring acute pancreatitis episodes. However, due to chronic-inflammatory adhesions of the mass to the tracheal wall, en-bloc resection was not possible without major tracheal resection. Since then, recurring pancreatitis episodes have been treated conservatively with antibiotics. We report this case due to its differing clinical and radiological findings in comparison to previous case reports, none of which pertained a case of ectopic pancreas tissue in the posterior mediastinum with recurring acute pancreatitis and mediastinitis.


Assuntos
Coristoma , Mediastinite , Pancreatite , Feminino , Humanos , Adulto Jovem , Doença Aguda , Coristoma/cirurgia , Coristoma/diagnóstico , Mediastinite/diagnóstico , Mediastinite/cirurgia , Mediastinite/complicações , Mediastino/diagnóstico por imagem , Mediastino/patologia , Pâncreas/patologia , Pancreatite/complicações , Pancreatite/diagnóstico
13.
Neuroradiology ; 66(5): 749-759, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38498208

RESUMO

PURPOSE: CT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke. METHODS: We retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared. RESULTS: The agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4. CONCLUSION: Reducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Redução da Medicação , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Tomografia Computadorizada por Raios X/métodos , Isquemia Encefálica/terapia , Perfusão , Imagem de Perfusão/métodos
14.
Eur Radiol Exp ; 8(1): 36, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480588

RESUMO

BACKGROUND: Accurate assessment of breast implants is important for appropriate clinical management. We evaluated silicone properties and diagnostic accuracy for characterizing silicone implants and detecting degenerative changes including rupture in photon-counting computed tomography (PCCT). METHODS: Over 16 months, we prospectively included patients with silicone implants and available breast magnetic resonance imaging (MRI) who received thoracic PCCT performed in prone position. Consensus reading of all available imaging studies including MRI served as reference standard. Two readers evaluated all implants in PCCT reconstructions for degenerative changes. In a subgroup of implants, mean density of silicone, adjacent muscle, and fat were measured on PCCT reconstructions. Contrast-to-noise ratios (CNRs) were calculated for implant-to-muscle and implant-to-fat. RESULTS: Among 21 subjects, aged 60 ± 13.1 years (mean ± standard deviation) with 29 implants PCCT showed the following: high accuracy for linguine sign, intraimplant fluid (all > 0.99), peri-implant silicone (0.95), keyhole sign (0.90), and folds of the membrane (0.81); high specificity for linguine sign, intraimplant fluid, keyhole sign, folds of the membrane (all > 0.99), and peri-implant silicone (0.98); and high sensitivity for linguine sign and intraimplant fluid (all > 0.99). In a subgroup of 12 implants, the highest CNR for implant-to-muscle was observed on virtual unenhanced reconstructions (20.9) and iodine maps (22.9), for implant-to-fat on iodine maps (27.7) and monoenergetic reconstructions (31.8). CONCLUSIONS: Our findings demonstrate that silicone breast implants exhibit distinct contrast properties at PCCT, which may provide incremental information for detection of degenerative changes and rupture of implants. RELEVANCE STATEMENT: Thoracic photon-counting computed tomography is a promising modality for the diagnostic assessment of silicone breast implants. KEY POINTS: • Thoracic photon-counting computed tomography demonstrates unique contrast properties of silicone breast implants. • Iodine map reconstructions reveal strong contrast-to-noise ratios for implant-to-muscle and implant-to-fat. • Thoracic photon-counting computed tomography shows high diagnostic accuracy in detecting implant degeneration and rupture. TRIAL REGISTRATION: German Clinical Trials Register number DRKS00028997, date of registration 2022-08-08, retrospectively registered.


Assuntos
Implantes de Mama , Iodo , Humanos , Implantes de Mama/efeitos adversos , Projetos Piloto , Silicones , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso , Feminino
15.
Radiol Med ; 129(5): 669-676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512614

RESUMO

PURPOSE: To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. MATERIAL AND METHODS: We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification-Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification. RESULTS: 19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values (p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT (p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images. CONCLUSION: PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.


Assuntos
Doenças Renais Císticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Doenças Renais Císticas/diagnóstico por imagem , Pessoa de Meia-Idade , Fótons , Idoso de 80 Anos ou mais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
16.
Dtsch Arztebl Int ; 121(9): 284-290, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38530931

RESUMO

BACKGROUND: Population-wide research on potential new imaging biomarkers of the kidney depends on accurate automated segmentation of the kidney and its compartments (cortex, medulla, and sinus). METHODS: We developed a robust deep-learning framework for kidney (sub-)segmentation based on a hierarchical, three-dimensional convolutional neural network (CNN) that was optimized for multiscale problems of combined localization and segmentation. We applied the CNN to abdominal magnetic resonance images from the population-based German National Cohort (NAKO) study. RESULTS: There was good to excellent agreement between the model predictions and manual segmentations. The median values for the body-surface normalized total kidney, cortex, medulla, and sinus volumes of 9934 persons were 158, 115, 43, and 24 mL/m2. Distributions of these markers are provided both for the overall study population and for a subgroup of persons without kidney disease or any associated conditions. Multivariable adjusted regression analyses revealed that diabetes, male sex, and a higher estimated glomerular filtration rate (eGFR) are important predictors of higher total and cortical volumes. Each increase of eGFR by one unit (i.e., 1 mL/min per 1.73 m2 body surface area) was associated with a 0.98 mL/m2 increase in total kidney volume, and this association was significant. Volumes were lower in persons with eGFR-defined chronic kidney disease. CONCLUSION: The extraction of image-based biomarkers through CNN-based renal sub-segmentation using data from a population-based study yields reliable results, forming a solid foundation for future investigations.


Assuntos
Rim , Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Rim/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Adulto , Alemanha , Taxa de Filtração Glomerular/fisiologia , Biomarcadores/análise , Redes Neurais de Computação , Aprendizado Profundo , Estudos de Coortes
17.
Biomark Res ; 12(1): 31, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38444025

RESUMO

BACKGROUND: Changes in serum metabolites in individuals with altered cardiac function and morphology may exhibit information about cardiovascular disease (CVD) pathway dysregulations and potential CVD risk factors. We aimed to explore associations of cardiac function and morphology, evaluated using magnetic resonance imaging (MRI) with a large panel of serum metabolites. METHODS: Cross-sectional data from CVD-free individuals from the population-based KORA cohort were analyzed. Associations between 3T-MRI-derived left ventricular (LV) function and morphology parameters (e.g., volumes, filling rates, wall thickness) and markers of carotid plaque with metabolite profile clusters and single metabolites as outcomes were assessed by adjusted multinomial logistic regression and linear regression models. RESULTS: In 360 individuals (mean age 56.3 years; 41.9% female), 146 serum metabolites clustered into three distinct profiles that reflected high-, intermediate- and low-CVD risk. Higher stroke volume (relative risk ratio (RRR): 0.53, 95%-CI [0.37; 0.76], p-value < 0.001) and early diastolic filling rate (RRR: 0.51, 95%-CI [0.37; 0.71], p-value < 0.001) were most strongly protectively associated against the high-risk profile compared to the low-risk profile after adjusting for traditional CVD risk factors. Moreover, imaging markers were associated with 10 metabolites in linear regression. Notably, negative associations of stroke volume and early diastolic filling rate with acylcarnitine C5, and positive association of function parameters with lysophosphatidylcholines, diacylphosphatidylcholines, and acylalkylphosphatidylcholines were observed. Furthermore, there was a negative association of LV wall thickness with alanine, creatinine, and symmetric dimethylarginine. We found no significant associations with carotid plaque. CONCLUSIONS: Serum metabolite signatures are associated with cardiac function and morphology even in individuals without a clinical indication of CVD.

18.
Eur J Radiol ; 173: 111360, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342061

RESUMO

PURPOSE: To determine the diagnostic accuracy of volumetric interpolated breath-hold examination sequences with fat suppression in Dixon technique (VIBE-Dixon) for cardiac thrombus detection. METHOD: From our clinical database, we retrospectively identified consecutive patients between 2014 and 2022 who had definite diagnosis or exclusion of cardiac thrombus confirmed by an independent adjudication committee, serving as the reference standard. All patients received 2D-Cine plus 2D-Late-Gadolinium-Enhancement (Cine + LGE) and VIBE-Dixon sequences. Two blinded readers assessed all images for the presence of cardiac thrombus. The diagnostic accuracy of Cine + LGE and VIBE-Dixon was determined and compared. RESULTS: Among 141 MRI studies (116 male, mean age: 61 years) mean image examination time was 28.8 ± 3.1 s for VIBE-Dixon and 23.3 ± 2.5 min for Cine + LGE. Cardiac thrombus was present in 49 patients (prevalence: 35 %). For both readers sensitivity for thrombus detection was significantly higher in VIBE-Dixon compared with Cine + LGE (Reader 1: 96 % vs.73 %, Reader 2: 96 % vs. 78 %, p < 0.01 for both readers), whereas specificity did not differ significantly (Reader 1: 96 % vs. 98 %, Reader 2: 92 % vs. 93 %, p > 0.1). Overall diagnostic accuracy of VIBE-Dixon was higher than for Cine + LGE (95 % vs. 89 %, p = 0.02) and was non-inferior to the reference standard (Delta ≤ 5 % with probability > 95 %). CONCLUSIONS: Biplanar VIBE-Dixon sequences, acquired within a few seconds, provided a very high diagnostic accuracy for cardiac thrombus detection. They could be used as stand-alone sequences to rapidly screen for cardiac thrombus in patients not amenable to lengthy acquisition times.


Assuntos
Meios de Contraste , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Gadolínio , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Trombose/diagnóstico por imagem , Aumento da Imagem/métodos
19.
Rofo ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408477

RESUMO

PURPOSE: Large language models (LLMs) such as ChatGPT have shown significant potential in radiology. Their effectiveness often depends on prompt engineering, which optimizes the interaction with the chatbot for accurate results. Here, we highlight the critical role of prompt engineering in tailoring the LLMs' responses to specific medical tasks. MATERIALS AND METHODS: Using a clinical case, we elucidate different prompting strategies to adapt the LLM ChatGPT using GPT4 to new tasks without additional training of the base model. These approaches range from precision prompts to advanced in-context methods such as few-shot and zero-shot learning. Additionally, the significance of embeddings, which serve as a data representation technique, is discussed. RESULTS: Prompt engineering substantially improved and focused the chatbot's output. Moreover, embedding of specialized knowledge allows for more transparent insight into the model's decision-making and thus enhances trust. CONCLUSION: Despite certain challenges, prompt engineering plays a pivotal role in harnessing the potential of LLMs for specialized tasks in the medical domain, particularly radiology. As LLMs continue to evolve, techniques like few-shot learning, zero-shot learning, and embedding-based retrieval mechanisms will become indispensable in delivering tailored outputs. KEY POINTS: · Large language models might impact radiological practice and decision-masking.. · However, implementation and performance are dependent on the assigned task.. · Optimization of prompting strategies can substantially improve model performance.. · Strategies for prompt engineering range from precision prompts to zero-shot learning..

20.
Eur Radiol Exp ; 8(1): 23, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353812

RESUMO

BACKGROUND: The growing prevalence of musculoskeletal diseases increases radiologic workload, highlighting the need for optimized workflow management and automated metadata classification systems. We developed a large-scale, well-characterized dataset of musculoskeletal radiographs and trained deep learning neural networks to classify radiographic projection and body side. METHODS: In this IRB-approved retrospective single-center study, a dataset of musculoskeletal radiographs from 2011 to 2019 was retrieved and manually labeled for one of 45 possible radiographic projections and the depicted body side. Two classification networks were trained for the respective tasks using the Xception architecture with a custom network top and pretrained weights. Performance was evaluated on a hold-out test sample, and gradient-weighted class activation mapping (Grad-CAM) heatmaps were computed to visualize the influential image regions for network predictions. RESULTS: A total of 13,098 studies comprising 23,663 radiographs were included with a patient-level dataset split, resulting in 19,183 training, 2,145 validation, and 2,335 test images. Focusing on paired body regions, training for side detection included 16,319 radiographs (13,284 training, 1,443 validation, and 1,592 test images). The models achieved an overall accuracy of 0.975 for projection and 0.976 for body-side classification on the respective hold-out test sample. Errors were primarily observed in projections with seamless anatomical transitions or non-orthograde adjustment techniques. CONCLUSIONS: The deep learning neural networks demonstrated excellent performance in classifying radiographic projection and body side across a wide range of musculoskeletal radiographs. These networks have the potential to serve as presorting algorithms, optimizing radiologic workflow and enhancing patient care. RELEVANCE STATEMENT: The developed networks excel at classifying musculoskeletal radiographs, providing valuable tools for research data extraction, standardized image sorting, and minimizing misclassifications in artificial intelligence systems, ultimately enhancing radiology workflow efficiency and patient care. KEY POINTS: • A large-scale, well-characterized dataset was developed, covering a broad spectrum of musculoskeletal radiographs. • Deep learning neural networks achieved high accuracy in classifying radiographic projection and body side. • Grad-CAM heatmaps provided insight into network decisions, contributing to their interpretability and trustworthiness. • The trained models can help optimize radiologic workflow and manage large amounts of data.


Assuntos
Aprendizado Profundo , Radiologia , Humanos , Inteligência Artificial , Estudos Retrospectivos , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...