Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros












Intervalo de ano de publicação
1.
Oper Dent ; 48(6): 720-731, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881067

RESUMO

OBJECTIVE: To evaluate the effects of commercial mouth rinses on color, roughness, sorption (SR), and solubility (SL) of resin composites. METHODS AND MATERIALS: Disc-shaped specimens (stage I: 6 mm × 2 mm; stage II: 10 mm × 1.5 mm) were made from the following resin composites (n=10): conventional nanofilled (Filtek Z350XT, 3M Oral Care), conventional nanohybrid (Luna, SDI), bulk-fill nanofilled (Filtek One Bulk-Fill, 3M Oral Care), and bulk-fill nanohybrid (Aura Bulk-Fill, SDI) exposed to distilled water (control), blue mouth rinse without alcohol (Colgate Total 12 Clean Mint, Colgate-Palmolive), or blue mouth rinse with alcohol and essential oil (Listerine Tartar Control, Johnson & Johnson). In stage I, tests were performed at the baseline, and after the immersion in solution time points to evaluate coordinates of the CIEL*a*b* system (ΔL*, Δa*, Δb*), general color change (ΔEab, ΔE00, and ΔSGU), and surface roughness (Ra). In stage II, SR and SL were evaluated (ISO 4049:2019) after immersion in the solutions for 7 days. The results were evaluated by generalized linear models (Ra, SR), Kruskal-Wallis, and Dunn tests (color, SL), with α = 0.05. RESULTS: There were no significative differences for Ra between the solutions. Both mouth rinses promoted significantly negative ΔL* (Luna), Δa* (Filtek One Bulk-fill), and Δb* (all materials except conventional nanofilled resin composite). Mouth rinse without alcohol promoted significantly negative Δa* on all resin composites tested. Both mouth rinses promoted higher ΔEab and ΔE00 for bulk-fill resin composites compared to control. Mouth rinse with alcohol caused higher ΔSGU for bulk-fill nanofilled resin composite. It also promoted greater SR in all the resin composites compared with mouth rinse without alcohol and higher SR in nanohybrid resin composites compared with control. Both mouth rinses promoted higher SL values in Luna and differed significantly from control. CONCLUSIONS: The physical properties were manufacturer dependent and mediated by mouth rinses. The mouth rinses promoted color changes in the resin composites, pointing out that bulk-fill resin composites were more affected by these effects, especially when the mouth rinse contained essential oil and alcohol.


Assuntos
Antissépticos Bucais , Óleos Voláteis , Antissépticos Bucais/farmacologia , Resinas Compostas , Etanol , Solubilidade , Teste de Materiais , Propriedades de Superfície
2.
Oper Dent ; 48(6): 677-688, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881103

RESUMO

OBJECTIVE: To evaluate the flexural strength of two types of high-viscosity resin composites (conventional or bulk-fill) that were repaired with either high-viscosity composites (conventional or bulk-fill) or low-viscosity composites (conventional or bulk-fill) of the same manufacturer (3M Oral Care, St Paul, MN, USA). METHODS AND MATERIALS: Specimens (25 mm × 2 mm × 2 mm) of both conventional nanofilled resin (Filtek Z350XT), and bulk-fill nanofilled resin (Filtek One Bulk Fill) were prepared. After fracture of the specimens in the 3-point bending test (initial), half of the specimens were repaired immediately afterwards (24 hours), and the other half were repaired after 6 months of storage in distilled water. Repairs were performed with (n=15) high-viscosity resin composites (Filtek Z350XT, Filtek One Bulk Fill), or their low-viscosity versions (Filtek Supreme XT Flow, Filtek Bulk Fill Flowable Restorative). The repair was performed by roughening the surface and applying phosphoric acid, silane, and adhesive. The bending test (results reported in MPa) was performed in a universal testing machine, and the fracture pattern was determined. Data were evaluated by generalized linear models, chi-square test and the Fisher exact test (α=0.05). RESULTS: There was no significant difference between the former pair of high-viscosity resins in terms of initial flexural strength (p=0.42). The repairs performed with low-viscosity resin composites after 24 hours or 6 months obtained higher MPa values compared with those using high-viscosity composites (p=0.0006). There was a significant decrease in MPa values when the repair was performed after 24 hours and an increase after 6 months, regardless of the material (p<0.0001). After 6 months, fractures involving the old (conventional) resin were more frequent in the repair performed with bulk-fill resin composites compared with the conventional composites (p=0.02). CONCLUSIONS: Considering the tested products, the material to be repaired did not influence the flexural strength of the repair composite; however, the use of the low-viscosity resin composites resulted in greater flexural strength of the repaired material. The repair of the aged composite resulted in an increase in its flexural strength, regardless of the material repaired or used to perform the repair.


Assuntos
Materiais Dentários , Resistência à Flexão , Viscosidade , Teste de Materiais , Resinas Compostas/uso terapêutico
3.
Epidemiol Infect ; 135(3): 505-18, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16893484

RESUMO

Health risks in the effluents of seven swine abattoirs and of seven poultry abattoirs were evaluated with regard to environment degradation and to dissemination of pathogenic microorganisms during the rainy and dry seasons. Supply-water samples from affluents and effluents of the treatment systems at different sites within the abattoir processing system were analysed. Similarly, water samples from the three recipient sites (emission point, 100 m upstream, 100 m downstream) were also analysed. Temperature, free residual chlorine (FRC), total coliform bacteria, Escherichia coli, enterococci, identification and serotyping of salmonellae were assessed. Scalding is the most significant stage in the slaughtering chain (P<0.05) when temperature is taken into account. Temperatures at effluents and at the sampled sites in the water bodies accorded to state and federal legislation standards. Supply waters did not meet the standards for FRC and microbial count standards according to the Ministry of Health and within limits imposed by the Industrial and Sanitary Inspection Regulations for Animal Products. Feather plucking and evisceration in poultry slaughter and the cleansing of carcasses and facilities in poultry and swine slaughtering had the highest contamination impact. The three loci at the water bodies were above the microbiological standards for classes II and III sites, in conformity with Law 8468 of the state of São Paulo, Brazil and Conama. Salmonella was found at several sites during slaughter, at both types of abattoirs, including in the effluent treatment system. This showed that these sites were the dissemination sources of the microorganism.


Assuntos
Matadouros , Eliminação de Resíduos Líquidos , Microbiologia da Água , Animais , Bactérias/isolamento & purificação , Cloro/análise , Escherichia coli/isolamento & purificação , Fezes/microbiologia , Aves Domésticas , Salmonella/isolamento & purificação , Estações do Ano , Suínos , Temperatura
4.
Arq. bras. med. vet. zootec ; Arq. bras. med. vet. zootec. (Online);55(5): 620-623, out. 2003. tab
Artigo em Português | LILACS | ID: lil-356868

RESUMO

Com o objetivo de verificar o papel da água utilizada durante a produção do leite como via de transmissão de Staphylococcus sp., fez-se a contagem de Staphylococcus coagulase negativa e Staphylococcus aureus nas amostras de água das fontes, dos reservatórios e dos estábulos de 30 propriedades leiteiras situadas na região Nordeste do Estado de São Paulo. As maiores ocorrências de isolamentos (10,0 e 16,6 por cento) e os maiores valores médios (4,3 10(4) e 2,5 10(4)) de contagens desses microrganismos foram encontrados nas amostras de água dos estábulos utilizada na obtenção de leite. Estes resultados são importantes pois evidenciam a possibilidade de contaminação do leite ou dos animais por cepas patogênicas.


Assuntos
Staphylococcus , Staphylococcus aureus , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...