Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Med Syst ; 48(1): 28, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441786

RESUMO

BACKGROUND: The Virtual Reality Headset (VRH) is a device aiming at improving patient's comfort by reducing pain and anxiety during medical interventions. Its interest during cardiac implantable electronic devices (CIED) implant procedures has not been studied. METHODS: We randomized consecutive patients admitted for pacemaker or Implantable Cardioverter Defibrillator (ICD) at our center to either standard analgesia care (STD-Group), or to VRH (VRH-Group). Patients in the STD-Group received intra-venous paracetamol (1 g) 60 min before the procedure, and local anesthesia was performed with lidocaine. For patients of the VRH-Group, VRH was used on top of standard care. We monitored patients' pain and anxiety using numeric rating scales (from 0 to 10) at the time of sub-cutaneous pocket creation, and during deep axillary vein puncture. Patient comfort during the procedure was assessed using a detailed questionnaire. Morphine consumption was also assessed. RESULTS: We randomized 61 patients to STD-Group (n = 31) or VRH-Group (n = 30). Pain and anxiety were lower in the VRH-Group during deep venous puncture (3.0 ± 2.0 vs. 4.8 ± 2.2, p = 0.002 and 2.4 ± 2.2 vs. 4.1 ± 2.4, p = 0.006) but not during pocket creation (p = 0.58 and p = 0.5). Morphine consumption was lower in the VRH-Group (1.6 ± 0.7 vs. 2.1 ± 1.1 mg; p = 0.041). Patients' overall comfort during procedure was similar in both groups. CONCLUSION: VRH use improved pain and anxiety control during deep venous puncture compared to standard analgesia care, and allowed morphine consumption reduction. However, pain and anxiety were similar at the time of sub-cutaneous pocket creation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Ansiedade/prevenção & controle , Dor , Derivados da Morfina
2.
Heart Rhythm ; 18(3): 360-365, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33181323

RESUMO

BACKGROUND: Electrical cardioversion is the first-line rhythm control therapy for symptomatic persistent atrial fibrillation (AF). Contemporary use of biphasic shock waveforms and anterior-posterior positioning of defibrillation electrodes have improved cardioversion efficacy; however, it remains unsuccessful in >10% of patients. OBJECTIVE: The purpose of this study was to assess the efficacy of applying active compression on defibrillation electrodes during AF cardioversion. METHODS: We performed a bicenter randomized study including patients referred for persistent AF cardioversion. Elective external cardioversion was performed by a standardized step-up protocol with increasing biphasic shock energy (50-100-150-200 J). Patients were randomly assigned to standard anterior-posterior defibrillation or to defibrillation with active compression applied over the anterior electrode. If sinus rhythm was not achieved at 200 J, a single crossover shock (200 J) was applied. Defibrillation threshold, total delivered energy, number of shocks, and success rate were compared between groups. RESULTS: We included 100 patients, 50 in each group. In the active compression group, defibrillation threshold was lower (103.1 ± 49.9 J vs 130.4 ± 47.7 J; P = .008), as well as total delivered energy (203 ± 173.3 J vs 309 ± 213.5 J; P = .0076) and number of shocks (2.2 ± 1.1 vs 2.9 ± 1.2; P = .0033), and cardioversion was more often successful (48 of 50 patients [96%] vs 42 of 50 patients [84%]; P = .0455) than that in the standard anterior-posterior group. Crossover from the compression group to the standard group was not successful (0 of 2 patients), whereas crossover from the standard group to the compression group was successful in 50% of patients (4 of 8). CONCLUSION: Active compression applied to the anterior defibrillation electrode is more effective for persistent AF cardioversion than standard anterior-posterior cardioversion, with lower defibrillation threshold and higher success rate.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores , Cardioversão Elétrica/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Estudos Cross-Over , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...