Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 362
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
2.
EMBO Mol Med ; 16(6): 1427-1450, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38684862

RESUMO

Lentiviral vectors (LV) are efficient vehicles for in vivo gene delivery to the liver. LV integration into the chromatin of target cells ensures their transmission upon proliferation, thus allowing potentially life-long gene therapy following a single administration, even to young individuals. The glycoprotein of the vesicular stomatitis virus (VSV.G) is widely used to pseudotype LV, as it confers broad tropism and high stability. The baculovirus-derived GP64 envelope protein has been proposed as an alternative for in vivo liver-directed gene therapy. Here, we perform a detailed comparison of VSV.G- and GP64-pseudotyped LV in vitro and in vivo. We report that VSV.G-LV transduced hepatocytes better than GP64-LV, however the latter showed improved transduction of liver sinusoidal endothelial cells (LSEC). Combining GP64-pseudotyping with the high surface content of the phagocytosis inhibitor CD47 further enhanced LSEC transduction. Coagulation factor VIII (FVIII), the gene mutated in hemophilia A, is naturally expressed by LSEC, thus we exploited GP64-LV to deliver a FVIII transgene under the control of the endogenous FVIII promoter and achieved therapeutic amounts of FVIII and correction of hemophilia A mice.


Assuntos
Células Endoteliais , Fator VIII , Terapia Genética , Vetores Genéticos , Hemofilia A , Lentivirus , Fígado , Animais , Hemofilia A/terapia , Hemofilia A/genética , Vetores Genéticos/genética , Células Endoteliais/metabolismo , Camundongos , Lentivirus/genética , Terapia Genética/métodos , Fígado/metabolismo , Fator VIII/genética , Fator VIII/metabolismo , Humanos , Proteínas do Envelope Viral/genética , Proteínas do Envelope Viral/metabolismo , Transdução Genética/métodos , Hepatócitos/metabolismo , Hepatócitos/virologia , Glicoproteínas de Membrana/genética , Glicoproteínas de Membrana/metabolismo
3.
J Clin Med ; 13(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38673430

RESUMO

Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.

5.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
6.
Heart Rhythm ; 2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38467355

RESUMO

BACKGROUND: Cardiac conduction disorder (CCD) in patients <50 years old is a rare and mostly unknown condition. OBJECTIVE: We aimed to assess clinical characteristics and genetic background of patients <50 years old with CCD of unknown origin. METHODS: We retrospectively reviewed a consecutive series of patients with a diagnosis of CCD before the age of 50 years referred to our center between January 2019 and December 2021. Patients underwent complete clinical examination and genetic evaluation. RESULTS: We enrolled 39 patients with a median age of 40 years (28-47 years) at the onset of symptoms. A cardiac implantable electronic device was implanted in 69% of the patients. In 15 of 39 CCD index patients (38%), we found a total of 13 different gene variations (3 pathogenic, 6 likely pathogenic, and 4 variants of uncertain significance), mostly in 3 genes (SCN5A, TRPM4, and LMNA). In our cohort, genetic testing led to the decision to implant an implantable cardioverter-defibrillator in 2 patients for the increased risk of sudden cardiac death. CONCLUSION: Patients with the occurrence of CCD before the age of 50 years present with a high rate of pathologic gene variations, mostly in 3 genes (SCN5A, TRPM4, and LMNA). The presence of pathogenic variations may add information about the prognosis and lead to an individualized therapeutic approach.

7.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

8.
Heart Rhythm ; 21(6): 874-880, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Pontuação de Propensão , Sistema de Registros , Volume Sistólico , Humanos , Masculino , Feminino , Idoso , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Estudos Prospectivos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Volume Sistólico/fisiologia , Resultado do Tratamento , Fascículo Atrioventricular/fisiopatologia , Seguimentos , Função Ventricular Esquerda/fisiologia
9.
Acta Cardiol ; 79(3): 367-373, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38441069

RESUMO

BACKGROUND: Conduction system disorders represent a frequent complication in patients undergoing surgical (surgical aortic valve replacement, SAVR) or percutaneous (transcatheter aortic valve implantation, TAVI) aortic valve replacement. The purpose of this survey was to evaluate experienced operators approach in this clinical condition. METHODS: This survey was independently conducted by the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) and it consisted of 24 questions regarding the respondents' profile, the characteristics of participating centres, and conduction disease management in different scenarios. RESULTS: Fifty-five physicians from 55 Italian arrhythmia centres took part in the survey. Prophylactic pacemaker implantation is rare. In case of persistent complete atrioventricular block (AVB), 49% and 73% respondents wait less than one week before implanting a definitive pacemaker after SAVR and TAVI, respectively. In case of second degree AVB, the respondents wait some days more for definitive implantation. Respondents consider bundle branch blocks, in particular pre-existing left bundle branch block (LBBB), the worst prognostic factors for pacemaker implantation after TAVI. The implanted valve type is considered a relevant element to evaluate. In patients with new-onset LBBB and severe/moderate left ventricular systolic dysfunction, respondents would implant a biventricular pacemaker in 100/55% of cases, respectively. CONCLUSIONS: Waiting time before a definitive pacemaker implantation after aortic valve replacement has reduced compared to the past, and it is anticipated in TAVI vs. SAVR. Bundle branch blocks are considered the worse prognostic factor for pacemaker implantation after TAVI. The type of pacemaker implanted in new-onset LBBB patients without severe left ventricular systolic dysfunction is heterogeneous.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Itália/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Doença do Sistema de Condução Cardíaco/terapia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Valvopatia Aórtica/cirurgia , Inquéritos e Questionários , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Sociedades Médicas , Marca-Passo Artificial , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Feminino , Masculino , Valva Aórtica/cirurgia , Gerenciamento Clínico , Sistema de Condução Cardíaco/fisiopatologia
11.
JACC Case Rep ; 29(4): 102211, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379650

RESUMO

Postpartum electrical storm due to torsade de pointes is a rare but life-threatening condition. The uniqueness of this case lies in the use of cabergoline to suppress postpartum ventricular arrhythmias in absence of heart disease. Timely multidisciplinary management is crucial to achieve final diagnosis, deliver proper treatment and improve prognosis.

12.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
13.
J Clin Med ; 13(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38256672

RESUMO

BACKGROUND: Bradyarrhythmia requiring pacemaker implantation among patients undergoing valve surgery may occur even after several years, with unclear predictors. Our aim was to investigate the incidence of pacemaker implantation at different follow-up times and identify associated predictors. METHODS: We conducted a retrospective study evaluating 1046 consecutive patients who underwent valve surgery at the Cardiac Surgery Division of Bologna University Hospital from 2005 to 2010. RESULTS: During 10 ± 4 years of follow-up, 11.4% of these patients required pacemaker implantation. Interventions on both atrioventricular valves independently predicted long-term pacemaker implantation (SHR 2.1, 95% CI 1.2-3.8, p = 0.014). Preoperative atrioventricular conduction disease strongly predicted long-term atrioventricular block, with right bundle branch block as the major predictor (SHR 7.0, 95% CI 3.9-12.4, p < 0.001), followed by left bundle branch block (SHR 4.9, 95% CI 2.4-10.1, p < 0.001), and left anterior fascicular block (SHR 3.9, 95% CI 1.8-8.3, p < 0.001). CONCLUSION: Patients undergoing valvular surgery have a continuing risk of atrioventricular block late after surgery until the 12-month follow-up, which was clearly superior to the rate of atrioventricular block observed at long-term. Pre-operative atrioventricular conduction disease and combined surgery on both atrioventricular valves are strong predictors of atrioventricular block requiring pacemaker implantation.

14.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
15.
Int J Cardiol ; 400: 131687, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38151163

RESUMO

The use of subcutaneous ICDs (S-ICD) is growing over years despite increasing alerts on premature battery depletion (PBD) and lead fractures leading to unanticipated device replacements. In our single-centre study including 192 patients, per year analysis demonstrated that incidence of PBD is higher than previously reported with overall greatest battery replacement requirements around the fifth year of follow-up. The underlying issue appears to be limited to old series devices, but only a longer follow-up will clarify the real impact of this phenomenon on patient outcomes. PBD is an underestimated S-ICDs issue and if the hereby demonstrated trend were to be confirmed in latest device series, this would bring significant concerns to patient safety and huge economic expense to health system.


Assuntos
Desfibriladores Implantáveis , Segurança do Paciente , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Resultado do Tratamento
16.
J Cardiovasc Med (Hagerstown) ; 24(12): 864-870, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37942788

RESUMO

AIMS: Brugada syndrome (BrS) is an inherited arrhythmic disease characterized by a coved ST-segment elevation in the right precordial electrocardiogram leads (type 1 ECG pattern) and is associated with a risk of malignant ventricular arrhythmias and sudden cardiac death. In order to assess the predictive value of the Shanghai Score System for the presence of a SCN5A mutation in clinical practice, we studied a cohort of 125 patients with spontaneous or fever/drug-induced BrS type 1 ECG pattern, variably associated with symptoms and a positive family history. METHODS: The Shanghai Score System items were collected for each patient and PR and QRS complex intervals were measured. Patients were genotyped through a next-generation sequencing (NGS) custom panel for the presence of SCN5A mutations and the common SCN5A polymorphism (H558R). RESULTS: The total Shanghai Score was higher in SCN5A+ patients than in SCN5A- patients. The 81% of SCN5A+ patients and the 100% of patients with a SCN5A truncating variant exhibit a spontaneous type 1 ECG pattern. A significant increase in PR (P = 0.006) and QRS (P = 0.02) was detected in the SCN5A+ group. The presence of the common H558R polymorphism did not significantly correlate with any of the items of the Shanghai Score, nor with the total score of the system. CONCLUSION: Data from our study suggest the usefulness of Shanghai Score collection in clinical practice in order to maximize genetic test appropriateness. Our data further highlight SCN5A mutations as a cause of conduction impairment in BrS patients.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , China/epidemiologia , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Arritmias Cardíacas , Mutação , Eletrocardiografia
17.
Eur Heart J Cardiovasc Imaging ; 25(1): e1-e32, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37861372

RESUMO

More than 500 000 cardiovascular implantable electronic devices (CIEDs) are implanted in the European Society of Cardiology countries each year. The role of cardiovascular imaging in patients being considered for CIED is distinctly different from imaging in CIED recipients. In the former group, imaging can help identify specific or potentially reversible causes of heart block, the underlying tissue characteristics associated with malignant arrhythmias, and the mechanical consequences of conduction delays and can also aid challenging lead placements. On the other hand, cardiovascular imaging is required in CIED recipients for standard indications and to assess the response to device implantation, to diagnose immediate and delayed complications after implantation, and to guide device optimization. The present clinical consensus statement (Part 1) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients undergoing implantation of conventional pacemakers, cardioverter defibrillators, and resynchronization therapy devices. The document summarizes the existing evidence regarding the use of imaging in patient selection and during the implantation procedure and also underlines gaps in evidence in the field. The role of imaging after CIED implantation is discussed in the second document (Part 2).


Assuntos
Sistema Cardiovascular , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/terapia , Cardioversão Elétrica , Coração
18.
Eur Heart J Cardiovasc Imaging ; 25(1): e33-e54, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37861420

RESUMO

Cardiac implantable electronic devices (CIEDs) improve quality of life and prolong survival, but there are additional considerations for cardiovascular imaging after implantation-both for standard indications and for diagnosing and guiding management of device-related complications. This clinical consensus statement (part 2) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients after implantation of conventional pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy (CRT) devices. The document summarizes the existing evidence regarding the role and optimal use of various cardiac imaging modalities in patients with suspected CIED-related complications and also discusses CRT optimization, the safety of magnetic resonance imaging in CIED carriers, and describes the role of chest radiography in assessing CIED type, position, and complications. The role of imaging before and during CIED implantation is discussed in a companion document (part 1).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis/efeitos adversos , Qualidade de Vida , Dispositivos de Terapia de Ressincronização Cardíaca , Imageamento por Ressonância Magnética , Marca-Passo Artificial/efeitos adversos
19.
J Clin Med ; 12(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685593

RESUMO

(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. PURPOSE: To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). METHODS: In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. RESULTS: A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III-IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1-13) to 42.2% (weeks_40-52, p < 0.001). CONCLUSIONS: High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence.

20.
Expert Rev Med Devices ; 20(11): 951-961, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37712650

RESUMO

BACKGROUND: The prognosis for heart failure (HF) patients remains poor, with a high mortality rate, and a marked reduction in quality of life (QOL) and functional status. This study aims to explore the ongoing needs of HF management and the epidemiology of patients followed by Italian HF clinics, with a specific focus on cardiac contractility modulation (CCM). RESEARCH DESIGN AND METHODS: Data from patients admitted to 14 HF outpatients clinics over 4 weeks were collected and compared to the results of a survey open to physicians involved in HF management operating in Italian centers. RESULTS: One hundred and five physicians took part in the survey. Despite 94% of patients receive a regular follow-up every 3-6 months, available therapies are considered insufficient in 30% of cases. Physicians reported a lack of treatment options for 23% of symptomatic patients with reduced ejection fraction (EF) and for 66% of those without reduced EF. Approximately 3% of HF population (two patients per month per HF clinic) meets the criteria for immediate CCM treatment, which is considered a useful option by 15% of survey respondents. CONCLUSIONS: Despite this relatively small percentage, considering total HF population, CCM could potentially benefit numerous HF patients, particularly the elderly, by reducing hospitalizations, improving functional capacity and QOL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...