Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Radiography (Lond) ; 28(2): 454-459, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34973869

RESUMO

INTRODUCTION: MR facilities must implement and maintain adequate screening and safety procedures to ensure safety during MR examinations. The aim of this study was to evaluate a multi-step MR safety screening process used at a 7T facility regarding incidence of different types of safety risks detected during the safety procedure. METHODS: Subjects scheduled for an MR examination and having entered the 7T facility during 2016-2019 underwent a pre-defined multi-step MR safety screening process. Screening documentation of 1819 included subjects was reviewed, and risks identified during the different screening steps were compiled. These data were also related to documented decisions made by a 7T MR safety committee and reported MR safety incidents. RESULTS: Passive or active implants (n = 315) were identified in a screening form and/or an additional documented interview in 305 subjects. Additional information not previously self-reported by the subject, regarding implants necessitating safety decisions performed by the staff was revealed in the documented interview in 102 subjects (106 items). In total, the 7T MR safety committee documented a decision in 36 (2%) of the included subjects. All of these subjects were finally cleared for scanning. CONCLUSION: A multi-step screening process allows a thorough MR screening of subjects, avoiding safety incidents. Different steps in the process allow awareness to rise and items to be detected that were missed in earlier steps. IMPLICATIONS FOR PRACTICE: Safety questions posed at a single timepoint during an MR screening process might not reveal all safety risks. Repetition and rephrasing of screening questions leads to increased detection of safety risks. This could be effectively mitigated by a multi-step screening process. A multi-disciplinary safety committee is efficient at short notice responding to unexpected safety issues.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos
2.
Int J Obes (Lond) ; 43(3): 533-544, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30181653

RESUMO

BACKGROUND/OBJECTIVES: Hypothalamic obesity (HO) occurs in 50% of patients with the pituitary tumor craniopharyngioma (CP). Attempts have been made to predict the risk of HO based on hypothalamic (HT) damage on magnetic resonance imaging (MRI), but none have included volumetry. We performed qualitative and quantitative volumetric analyses of HT damage. The results were explored in relation to feeding related peptides and body fat. SUBJECTS/METHODS: A cross-sectional study of childhood onset CPs involving 3 Tesla MRI, was performed at median 22 years after first operation; 41 CPs, median age 35 (range: 17-56), of whom 23 had HT damage, were compared to 32 controls. After exclusions, 35 patients and 31 controls remained in the MRI study. Main outcome measures were the relation of metabolic parameters to HT volume and qualitative analyses of HT damage. RESULTS: Metabolic parameters scored persistently very high in vascular risk particularly among HT damaged patients. Patients had smaller HT volumes compared to controls 769 (35-1168) mm3 vs. 879 (775-1086) mm3; P < 0.001. HT volume correlated negatively with fat mass and leptin among CP patients (rs = -0.67; P < .001; rs = -0.53; P = 0.001), and explained 39% of the variation in fat mass. For every 100 mm3 increase in HT volume fat mass decreased by 2.7 kg (95% CI: 1.5-3.9; P < 0.001). Qualitative assessments revealed HT damage in three out of six patients with normal volumetry, but HT damage according to operation records. CONCLUSIONS: A decrease in HT volume was associated with an increase in fat mass and leptin. We present a method with a high inter-rater reliability (0.94) that can be applied by nonradiologists for the assessment of HT damage. The method may be valuable in the risk assessment of diseases involving the HT.


Assuntos
Craniofaringioma , Hipotálamo , Obesidade/complicações , Neoplasias Hipofisárias , Adolescente , Adulto , Craniofaringioma/complicações , Craniofaringioma/diagnóstico por imagem , Craniofaringioma/epidemiologia , Craniofaringioma/patologia , Estudos Transversais , Feminino , Humanos , Hipotálamo/diagnóstico por imagem , Hipotálamo/patologia , Masculino , Pessoa de Meia-Idade , Neoplasias Hipofisárias/complicações , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/epidemiologia , Neoplasias Hipofisárias/patologia , Fatores de Risco , Adulto Jovem
3.
Eur J Endocrinol ; 178(6): 577-587, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29599407

RESUMO

CONTEXT: Patients with craniopharyngioma (CP) and hypothalamic lesions (HL) have cognitive deficits. Which neural pathways are affected is unknown. OBJECTIVE: To determine whether there is a relationship between microstructural white matter (WM) alterations detected with diffusion tensor imaging (DTI) and cognition in adults with childhood-onset CP. DESIGN: A cross-sectional study with a median follow-up time of 22 (6-49) years after operation. SETTING: The South Medical Region of Sweden (2.5 million inhabitants). PARTICIPANTS: Included were 41 patients (24 women, ≥17 years) surgically treated for childhood-onset CP between 1958-2010 and 32 controls with similar age and gender distributions. HL was found in 23 patients. MAIN OUTCOME MEASURES: Subjects performed cognitive tests and magnetic resonance imaging, and images were analyzed using DTI of uncinate fasciculus, fornix, cingulum, hippocampus and hypothalamus as well as hippocampal volumetry. RESULTS: Right uncinate fasciculus was significantly altered (P ≤ 0.01). Microstructural WM alterations in left ventral cingulum were significantly associated with worse performance in visual episodic memory, explaining approximately 50% of the variation. Alterations in dorsal cingulum were associated with worse performance in immediate, delayed recall and recognition, explaining 26-38% of the variation, and with visuospatial ability and executive function, explaining 19-29%. Patients who had smaller hippocampal volume had worse general knowledge (P = 0.028), and microstructural WM alterations in hippocampus were associated with a decline in general knowledge and episodic visual memory. CONCLUSIONS: A structure to function relationship is suggested between microstructural WM alterations in cingulum and in hippocampus with cognitive deficits in CP.


Assuntos
Disfunção Cognitiva/diagnóstico por imagem , Craniofaringioma/diagnóstico por imagem , Hipocampo/diagnóstico por imagem , Neoplasias Hipofisárias/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adolescente , Adulto , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/psicologia , Craniofaringioma/epidemiologia , Craniofaringioma/psicologia , Estudos Transversais , Imagem de Tensor de Difusão/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Neoplasias Hipofisárias/epidemiologia , Neoplasias Hipofisárias/psicologia , Distribuição Aleatória , Adulto Jovem
4.
Acta Anaesthesiol Scand ; 60(1): 93-102, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26251260

RESUMO

BACKGROUND: Currently 80% of donor lungs are not accepted for transplantation, often due to fluid overload. Our aim was to investigate if forced fluid infusion may be replaced by a new pharmacological therapy to stabilize circulation after brain death in an animal model, and to assess therapy effects on lung function and morphology trough blood gas parameters and state-of-the-art High-resolution CT (HRCT). METHODS: Brain death was caused by surgical decapitation. To maintain mean aortic pressure > 60 mmHg, pigs were treated with forced electrolyte solution infusion (GI; n = 6) or the pharmacological therapy (GII; n = 11). GIII (n = 11) were non-decapitated controls. Lung function was investigated with blood gases and lung morphology with HRCT. RESULTS: GI pigs became circulatory instable 4-6 h after brain death in spite of forced fluid infusion, five pigs showed moderate to severe pulmonary edema on HRCT and median final PaO2 /FiO2 was 29 kPa (Q1; Q3; range 26; 40; 17-76). GII and GIII were circulatory stable (mean aortic pressure > 80 mmHg) and median final PaO2 /FiO2 after 24 h was 72 kPa (Q1; Q3; range 64; 76; 53-91) (GII) and 66 kPa (55; 78; 43-90) (GIII). On HRCT, only two pigs in GII had mild pulmonary edema and none in GIII. More than 50% of HRCT exams revealed unexpected lung disease even in spite of PaO2 /FiO2 > 40 kPa. CONCLUSION: Pharmacological therapy but not forced fluid infusion prevented circulatory collapse and extensive HRCT verified pulmonary edema after acute brain death. HRCT was useful to evaluate lung morphology and revealed substantial occult parenchymal changes justifying efforts toward a more intense use of HRCT in the pre-transplant evaluation.


Assuntos
Circulação Sanguínea , Morte Encefálica/diagnóstico , Pulmão/diagnóstico por imagem , Animais , Gasometria , Decapitação , Eletrólitos/administração & dosagem , Eletrólitos/uso terapêutico , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Oxigênio/sangue , Respiração com Pressão Positiva , Edema Pulmonar/fisiopatologia , Respiração Artificial , Sus scrofa , Suínos , Tomografia Computadorizada por Raios X
6.
Br J Radiol ; 86(1031): 20130388, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24049128

RESUMO

OBJECTIVE: To evaluate the image quality produced by six different iterative reconstruction (IR) algorithms in four CT systems in the setting of brain CT, using different radiation dose levels and iterative image optimisation levels. METHODS: An image quality phantom, supplied with a bone mimicking annulus, was examined using four CT systems from different vendors and four radiation dose levels. Acquisitions were reconstructed using conventional filtered back-projection (FBP), three levels of statistical IR and, when available, a model-based IR algorithm. The evaluated image quality parameters were CT numbers, uniformity, noise, noise-power spectra, low-contrast resolution and spatial resolution. RESULTS: Compared with FBP, noise reduction was achieved by all six IR algorithms at all radiation dose levels, with further improvement seen at higher IR levels. Noise-power spectra revealed changes in noise distribution relative to the FBP for most statistical IR algorithms, especially the two model-based IR algorithms. Compared with FBP, variable degrees of improvements were seen in both objective and subjective low-contrast resolutions for all IR algorithms. Spatial resolution was improved with both model-based IR algorithms and one of the statistical IR algorithms. CONCLUSION: The four statistical IR algorithms evaluated in the study all improved the general image quality compared with FBP, with improvement seen for most or all evaluated quality criteria. Further improvement was achieved with one of the model-based IR algorithms. ADVANCES IN KNOWLEDGE: The six evaluated IR algorithms all improve the image quality in brain CT but show different strengths and weaknesses.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Humanos , Modelos Teóricos , Neuroimagem , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/instrumentação , Tomografia Computadorizada por Raios X/métodos
7.
Acta Radiol ; 53(4): 468-72, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22509068

RESUMO

BACKGROUND: Computed tomography (CT) of the brain is performed with high local doses due to high demands on low contrast resolution. Advanced algorithms for noise reduction might be able to preserve critical image information when reducing radiation dose. PURPOSE: To evaluate the effect of advanced noise filtering on image quality in brain CT acquired with reduced radiation dose. MATERIAL AND METHODS: Thirty patients referred for non-enhanced CT of the brain were examined with two helical protocols: normal dose (ND, CTDI(vol) 57 mGy) and low dose (LD, CTDI(vol) 40 mGy) implying a 30% radiation dose reduction. Images from the LD examinations were also postprocessed with a noise reduction software with non-linear filters (SharpView CT), creating filtered low dose images (FLD) for each patient. The three image stacks for each patient were presented side by side in randomized order. Five radiologists, blinded for dose level and filtering, ranked these three axial image stacks (ND, LD, FLD) as best to poorest (1 to 3) regarding three image quality criteria. Measurements of mean Hounsfield units (HU) and standard deviation (SD) of the HU were calculated for large region of interest in the centrum semiovale as a measure for noise. RESULTS: Ranking results in pooled data showed that the advanced noise filtering significantly improved the image quality in FLD as compared to LD images for all tested criteria. No significant differences in image quality were found between ND examinations and FLD. However, there was a notable inter-reader spread of the ranking. SD values were 15% higher for LD as compared to ND and FLD. CONCLUSION: The advanced noise filtering clearly improves image quality of CT examinations of the brain. This effect can be used to significantly lower radiation dose.


Assuntos
Encéfalo/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Doses de Radiação
8.
Magn Reson Imaging ; 22(7): 929-35, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15288133

RESUMO

The implications of changing the echo time of a gradient-echo echo planar imaging sequence applied to dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) for perfusion imaging at 3T were investigated. Four echo times in the range of 21 to 45 ms were examined in a total of 17 patients who received a dose of 0.1 mmol/kg bodyweight Gadobutrol (Gadovist, 1.0 mmol/ml). As the primary optimization parameter, the concentration-to-noise ratio (SNRc) was selected as it takes effects of variations in baseline as well as in signal drop into account. In an analysis of gray matter, white matter and arterial regions of interest, SNRc showed the highest values for the shortest applied echo time in all cases. Maps of regional cerebral blood volume (rCBV) and blood flow (rCBF) were calculated using deconvolution based on singular value decomposition. The quality of rCBF and rCBV images was judged to be good or excellent in all cases, independent of the echo time. Calculated gray matter/white matter ratios of rCBF and rCBV displayed no significant dependence on the applied echo time. Considering the better SNRc and arterial signal saturation aspects, we found that the shortest investigated echo time was the superior one. We thus suggest that short echo times should be applied, taking technical limitations and clinical demands into consideration.


Assuntos
Encéfalo/irrigação sanguínea , Imagem Ecoplanar/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/anatomia & histologia , Mapeamento Encefálico/métodos , Circulação Cerebrovascular , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Fluxo Sanguíneo Regional/fisiologia , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...