Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
BMC Rheumatol ; 8(1): 9, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424614

RESUMO

BACKGROUND: Impella is an advanced ventricular assist device frequently used as a bridge to heart transplantation. The association of Impella with increased rates of gout flares has not been studied. Our primary aim is to determine the rates of gout flares in patients on Impella support. METHODOLOGY: A retrospective study was conducted between January 2017 and September 2022 involving all patients who underwent heart transplantation. The cohort was divided into two groups based on Impella support for statistical analysis. In patients receiving Impella support, outcome measures were compared based on the development of gout flares. 1:1 nearest neighbor propensity match, as well as inverse propensity of treatment weighted analyses, were performed to explore the causal relationship between impella use and gout flare in our study population. RESULTS: Our analysis included 213 patients, among which 42 (19.71%) patients were supported by Impella. Impella and non-Impella groups had similar age, race, and BMI, but more males were in the Impella group. Gout and chronic kidney disease were more prevalent in Impella-supported patients, while coronary artery disease was less common. The prevalence of gout flare was significantly higher in Impella patients (30.9% vs. 5.3%). 42 Impella-supported patients were matched with 42 patients from the non-impella group upon performing a 1:1 propensity matching. Impella-supported patients were noted to have a significantly higher risk of gout flare (30.9% vs. 7.1%, SMD = 0.636), despite no significant difference in pre-existing gout history and use of anti-gout medications. Impella use was associated with a significantly increased risk of gout flare in unadjusted (OR 8.07), propensity-matched (OR 5.83), and the inverse propensity of treatment-weighted analysis (OR 4.21). CONCLUSION: Our study is the first to identify the potential association between Impella support and increased rates of gout flares in hospitalized patients. Future studies are required to confirm this association and further elucidate the biological pathways. It is imperative to consider introducing appropriate measures to prevent and promptly manage gout flares in Impella-supported patients.

2.
Perfusion ; : 2676591231220305, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060246

RESUMO

Background: Impella 5.5® with Smart Assist is a minimally invasive Left Ventricular Assist Devices (LVAD) approved by the Food and Drug Administration (FDA) for treating ongoing cardiogenic shock for up to 14 days. The Impella® intends to reduce ventricular workload and provide the circulatory support necessary for myocardial recovery.Research Question: Compared to standard practice, does adding an extension piece to the purge tube side arm of the Impella® Device decrease the incidence of device failure and positively impact the health outcome of adult patients receiving Impella® support?Study Design and Methods: A retrospective chart review of ICU patients was done at a tertiary care center from August 2018 to August 2022 to assess the differences in patient outcomes related to Impella® Device utilization before and after the implementation of the extension piece to the purge tube sidearm. Among patients reviewed, a total of 20 were included in our review, with seven not having the purge tube side arm extension added, while 13 patients had the extension.Results: The two study groups had no significant difference in patient health outcomes. Additionally, there were no instances of device failure requiring explanation without the extension tubing. However, there were no cases of the purge cassette cracking with the addition of the extension tubing.Conclusion: The addition of extension tubing to the purge cassette of the Impella® Device did not impact patient health outcomes or the incidence of device failure. There was a complete reduction in the incidence of the purge cassette cracking, which could reduce the potential for infection or device failure over a long period of mechanical support. There is a need for long-term prospective studies to confirm the results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...