1.
Br J Radiol ; 88(1048): 20140413, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25671247

RESUMO

OBJECTIVE: To determine the relationship between the dose to the inner ear or pituitary gland and radiation-induced late effects of skull base radiation therapy. METHODS: 140 patients treated between 2000 and 2008 were considered for this study. Hearing loss and endocrine dysfunction were retrospectively reviewed on pre- and post-radiation therapy audiometry or endocrine assessments. Two normal tissue complication probability (NTCP) models were considered (Lyman-Kutcher-Burman and log-logistic) whose parameters were fitted to patient data using receiver operating characteristics and maximum likelihood analysis. The method provided an estimation of the parameters of a generalized equivalent uniform dose (gEUD)-based NTCP after conversion of dose-volume histograms to equivalent doses. RESULTS: All 140 patients had a minimum follow up of 26 months. 26% and 44% of patients experienced mild hearing loss and endocrine dysfunction, respectively. The fitted values for TD50 and γ50 ranged from 53.6 to 60.7 Gy and from 1.9 to 2.9 for the inner ear and were equal to 60.6 Gy and 4.9 for the pituitary gland, respectively. All models were ranked equal according to Akaike's information criterion. CONCLUSION: Mean dose and gEUD may be used as predictive factors for late ear and pituitary gland late complications after skull base proton and photon radiation therapy. ADVANCES IN KNOWLEDGE: In this study, we have reported mean dose effects and dose-response relationship of small organs at risk (partial volumes of the inner ear and pituitary gland), which could be useful to define optimal dose constraints resulting in an improved therapeutic ratio.


Assuntos
Perda Auditiva/diagnóstico , Hipófise/efeitos da radiação , Lesões por Radiação/diagnóstico , Neoplasias da Base do Crânio/radioterapia , Adulto , Audiometria , Criança , Relação Dose-Resposta à Radiação , Feminino , Humanos , Hipotálamo/efeitos da radiação , Masculino , Órgãos em Risco , Fótons , Valor Preditivo dos Testes , Prótons , Doses de Radiação , Dosagem Radioterapêutica , Radioterapia Conformacional , Estudos Retrospectivos
2.
Phys Med Biol ; 58(12): 4255-76, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23719506

RESUMO

Proton beam range is of major concern, in particular, when images used for dose computations are artifacted (for example in patients with surgically treated bone tumors). We investigated several conditions and methods for determination of computed tomography Hounsfield unit (CT-HU) calibration curves, using two different conversion schemes. A stoichiometric methodology was used on either kilovoltage (kV) or megavoltage (MV) CT images and the accuracy of the calibration methods was evaluated. We then studied the effects of metal artifacts on proton dose distributions using metallic implants in rigid phantom mimicking clinical conditions. MV-CT images were used to evaluate relative proton stopping power in certain high density implants, and a methodology is proposed for accurate delineation and dose calculation, using a combined set of kV- and MV-CT images. Our results show good agreement between measurements and dose calculations or relative proton stopping power determination (<5%). The results also show that range uncertainty increases when only kV-CT images are used or when no correction is made on artifacted images. However, differences between treatment plans calculated on corrected kV-CT data and MV-CT data remained insignificant in the investigated patient case, even with streak artifacts and volume effects that reduce the accuracy of manual corrections.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Calibragem , Humanos , Metais , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Próteses e Implantes , Terapia com Prótons/efeitos adversos , Radiometria