Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; 37(10): e5195, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38845018

RESUMO

The neuronal tricarboxylic acid and glutamate/glutamine (Glu/Gln) cycles play important roles in brain function. These processes can be measured in vivo using dynamic 1H-[13C] MRS during administration of 13C-labeled glucose. Proton-observed carbon-edited (POCE) MRS enhances the signal-to-noise ratio (SNR) compared with direct 13C-MRS. Ultra-high field further boosts the SNR and increases spectral dispersion; however, even at 7 T, Glu and Gln 1H-resonances may overlap. Further gain can be obtained with selective POCE (selPOCE). Our aim was to create a setup for indirect dynamic 1H-[13C] MRS in the human brain at 7 T. A home-built non-shielded transmit-receive 13C-birdcage head coil with eight transmit-receive 1H-dipole antennas was used together with a 32-channel 1H-receive array. Electromagnetic simulations were carried out to ensure that acquisitions remained within local and global head SAR limits. POCE-MRS was performed using slice-selective excitation with semi-localization by adiabatic selective refocusing (sLASER) and stimulated echo acquisition mode (STEAM) localization, and selPOCE-MRS using STEAM. Sequences were tested in a phantom containing non-enriched Glu and Gln, and in three healthy volunteers during uniformly labeled 13C-glucose infusions. In one subject the voxel position was alternated between bi-frontal and bi-occipital placement within one session. [4-13C]Glu-H4 and [4-13C]Gln-H4 signals could be separately detected using both STEAM-POCE and STEAM-selPOCE in the phantom. In vivo, [4,5-13C]Glx could be detected using both sLASER-POCE and STEAM-POCE, with similar sensitivities, but [4,5-13C]Glu and [4,5-13C]Gln signals could not be completely resolved. STEAM-POCE was alternately performed bi-frontal and bi-occipital within a single session without repositioning of the subject, yielding similar results. With STEAM-selPOCE, [4,5-13C]Glu and [4,5-13C]Gln could be clearly separated. We have shown that with our setup indirect dynamic 1H-[13C] MRS at 7 T is feasible in different locations in the brain within one session, and by using STEAM-selPOCE it is possible to separate Glu from Gln in vivo while obtaining high quality spectra.


Assuntos
Encéfalo , Humanos , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem , Masculino , Espectroscopia de Prótons por Ressonância Magnética , Adulto , Imagens de Fantasmas , Feminino , Isótopos de Carbono
2.
J Pharm Sci ; 103(7): 2125-2130, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24890761

RESUMO

The ability to predict in vivo response of an oral dosage form based on an in vitro technique has been a sought after goal of the pharmaceutical scientist. Dissolution testing that demonstrates discrimination to various critical formulations or process attributes provides a sensitive quality check that may be representative or may be overpredictive of potential in vivo changes. Dissolution methodology with an established in vitro-in vivo relationship or correlation may provide the desired in vivo predictability. To establish this in vitro-in vivo link, a clinical study must be performed. In this article, recommendations are given in the selection of batches for the clinical study followed by potential outcome scenarios. The investigation of a Level C in vitro-in vivo correlation (IVIVC), which is the most common correlation for immediate-release oral dosage forms, is presented. Lastly, an IVIVC case study involving a biopharmaceutical classification system class IV compound is presented encompassing this strategy and techniques.


Assuntos
Biofarmácia/métodos , Modelos Biológicos , Preparações Farmacêuticas/classificação , Preparações Farmacêuticas/metabolismo , Farmacocinética , Administração Oral , Formas de Dosagem , Liberação Controlada de Fármacos , Humanos , Técnicas In Vitro , Preparações Farmacêuticas/administração & dosagem , Preparações Farmacêuticas/química , Ensaios Clínicos Controlados Aleatórios como Assunto , Solubilidade