Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Clin Res Cardiol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39230714

RESUMO

AIMS: To quantify greyzone fibrosis (GZF) in patients after acute myocardial infarction (MI) and to evaluate its correlation with MI-free survival and improvements in left ventricular ejection fraction (LVEF) compared with the established risk factors high-sensitivity cardiac troponin T (hs-cTnT) and Late Gadolinium Enhancement (LGE). METHODS AND RESULTS: The study involved 176 patients who experienced acute MI and underwent cardiac magnetic resonance (CMR) prior to hospital discharge, followed by a second CMR on average six months later. LGE was quantified in both examinations, a separate analysis of the GZF was conducted only in the follow-up CMR after resolution of the initial infarct edema. LVEF was measured in both CMR. hs-cTnT levels were assessed at hospital admission, as well as 8, 16, 24, 48 and 72 h after coronary intervention. Telephone follow-ups were conducted annually for up to 8 years. LGE measurements showed better correlation with MI-free survival (Harrell's C of 0.711 of LGE mass) compared to GZF (0.579 of GZF mass). Additionally, hs-cTnT outperformed GZF (Harrell's C of 0.645). As an univariable predictor for MI-free survival, only hs-cTnT reached significance (p < 0.05). With regard to improvements in ejection fraction, both hs-cTnT and LGE measurements showed acceptable correlation with improvement in ejection fraction (p < 0.05), while GZF measurements showed no correlation (p > 0.5). CONCLUSIONS: In CMR, the assessment of GZF demonstrated inferior p correlation compared to hs-cTnT and LGE in patients after acute MI with respect to the endpoint of MI-free survival. Furthermore, GZF showed no correlation with the improvement of LVEF.

2.
J Clin Med ; 13(18)2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39336936

RESUMO

Background/Objectives: For patients with percutaneous coronary intervention (PCI) of an unprotected left main coronary artery (uLMCA) stenosis, the optimal duration of dual antiplatelet therapy (DAPT) remains a matter of debate. The purpose of this study was to compare clinical outcomes of 6- versus 12-month DAPT duration in patients with PCI of an uLMCA and stable angina. Methods: In this retrospective analysis, we included consecutive patients of our centre who underwent PCI of uLMCA stenosis for stable angina and who received DAPT with acetylsalicylic acid and clopidogrel for either 6 or 12 months. The primary endpoint was the composite of all-cause mortality, myocardial infarction, and target lesion revascularization at one year. Secondary endpoints included individual components of the primary endpoint, definite/probable stent thrombosis, and bleeding. Clinical outcomes were assessed by unadjusted analysis and by inverse probability of treatment weighting (IPTW). Results: Out of 984 included patients, 339 (34.5%) received DAPT for 6 months and 645 (65.5%) for 12 months. The primary endpoint occurred in 51 patients (15.2%) in the 6-month group and in 104 (16.3%) in the 12-month group (p = 0.674). Incidences of stent thrombosis (0.9% versus 0.3%, p = 0.224) and BARC 3,4,5 bleeding (6% versus 5.8%, p = 0.808) were also comparable in both groups. We found no significant differences in the primary endpoint and its components or BARC 3,4,5 bleeding between 6 and 12 months. Conclusions: Our findings do not support the extension of DAPT beyond 6 months after PCI for uLMCA in patients with stable angina.

3.
Kidney360 ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167454

RESUMO

BACKGROUND: Renin-angiotensin-aldosterone system inhibitor (RAASi) therapy provides cardiorenal protection but is often down-titrated or discontinued following a hyperkalemia episode. This observational study describes the extent of hyperkalemia-related RAASi reduction in patients with chronic kidney disease (CKD) and/or heart failure (HF), and estimates the number needed to treat (NNT) to avoid a first hospitalization if RAASi had been maintained at the prior dose. METHODS: Healthcare registers and claims data from Germany, Spain, Sweden, and the UK were used to identify non-dialysis patients with CKD and/or HF who had a hyperkalemia episode while on RAASi. Patients whose RAASi therapy was reduced (down-titrated/discontinued) after the hyperkalemia episode were propensity score (PS)-matched to those with maintained RAASi, and their risks of a hospitalization within 6 months were estimated using the Kaplan-Meier method. Based on the absolute difference in this 6-month risk, the NNT framework was applied to estimate the number of patients who needed to have maintained instead of reduced their RAASi to avoid a first hospitalization during this period. RESULTS: Overall, 40,059 patients from Germany, Spain, Sweden, and the UK were included. Presence of CKD at baseline was similar across countries (72%-92%), while HF was less common in Spain (18%) versus other countries (32%-71%). After the hyperkalemia episode, RAASi was reduced in 25%-57% of patients. Following PS matching, the 6-month risk of hospitalization was consistently higher in those with reduced versus maintained RAASi; the absolute risk difference ranged from 2.7% to 7.3%. Applying the NNT framework, these data suggest that a first hospitalization within 6 months could potentially have been avoided if 25 patients had maintained instead of reduced their RAASi. CONCLUSIONS: Our findings suggest a potential for avoiding a first hospitalization, even within a short time frame, by increasing adherence to guidelines to maintain instead of reduce RAASi after a hyperkalemia episode.

4.
Eur Heart J Case Rep ; 8(6): ytae300, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38947146

RESUMO

Background: Delayed coronary obstruction (DCO) is a rare but potentially life-threatening complication after transcatheter aortic valve implantation (TAVI) mostly affecting the left main coronary artery (LMCA) and often caused by prosthesis endothelialization or thrombus formations. Herein, we report an unusual case of a delayed LMCA-obstruction caused by a calcium nodule, which was diagnosed 4 months after TAVI due to recurrent ventricular tachycardia (VT) episodes. Case summary: A 73-year-old patient was readmitted to an external hospital with syncope three months after TAVI. Fast VT could be induced in electrophysiological examination, why the patient received a two-chamber implantable cardioverter defibrillator (ICD). However, after 1 month the patient was readmitted to our department with another syncope. Implantable cardioverter defibrillator records revealed multiple fast VT episodes (200-220 b.p.m.). In addition, the patient reported new-onset exertional dyspnoea (New York Class Association Stage III) and elevated high-sensitive cardiac troponin of 115 ng/L. Due to the symptoms and laboratory markers indicating potential myocardial ischaemia, a cardiac computed tomography angiography (CCTA) was performed. Cardiac computed tomography angiography revealed obstruction of the LMCA likely caused by calcium shift during TAVI. After CCTA-guided percutaneous coronary intervention, patient's course remained uneventful. Discussion: The present case report highlights the role of CCTA as a powerful non-invasive diagnostic tool in complex settings after TAVI. Delayed coronary obstruction as a procedural complication can occur after TAVI and manifest with various symptoms, including new-onset or recurrent VTs, like in the present case. Cardiac computed tomography angiography provided accurate assessment of the implanted prosthesis and detection of DCO, thus guiding the subsequent PCI.

5.
Clin Res Cardiol ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080016

RESUMO

AIM: To evaluate the effects of lipid-lowering medications of different intensities on total, calcified, and non-calcified plaque volumes in patients undergoing serial cardiac computed tomography angiography (CCTA). METHODS: Individuals with chronic coronary syndromes from 11 centers were included in a retrospective registry. Total, calcified, and non-calcified plaque volumes were quantified and the relative difference in plaque volumes between baseline and follow-up CCTA was calculated. The intensity of lipid-lowering treatment was designated as low, moderate, or high, based on current recommendations. RESULTS: Of 216 patients (mean age 63.1 ± 9.7 years), undergoing serial CCTA (median timespan = 824.5 [IQR = 463.0-1323.0] days), 89 (41.2%) received no or low-intensity lipid-lowering medications, and 80 (37.0%) and 47 (21.8%) moderate- and high-intensity lipid-lowering agents, respectively. Progression of total and non-calcified plaque was attenuated in patients on moderate-/high- versus those on no/low-intensity treatment and arrested in patients treated with high-intensity statins or PCSK9 inhibitors (p < 0.001). Halted increase of non-calcified plaque was associated with LDL-cholesterol reduction (p < 0.001), whereas calcified plaque mass and Agatston score increased irrespective of the lipid-lowering treatment (p = NS). The intensity of lipid-lowering therapy robustly predicted attenuation of non-calcified plaque progression as a function of the time duration between the two CCTA scans, and this was independent of age and cardiovascular risk factors (HR = 3.83, 95% CI = 1.81-8.05, p < 0.001). CONCLUSION: The LOCATE multi-center observational study shows that progression of non-calcified plaques, which have been previously described as precursors of acute coronary syndromes, can be attenuated with moderate-intensity, and arrested with high-intensity lipid-lowering therapy. GERMAN CLINICAL TRIALS REGISTER: DRKS00031954.

6.
BMC Geriatr ; 24(1): 517, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872086

RESUMO

BACKGROUND: In the hospital setting, frailty is a significant risk factor, but difficult to measure in clinical practice. We propose a reweighting of an existing diagnoses-based frailty score using routine data from a tertiary care teaching hospital in southern Germany. METHODS: The dataset includes patient characteristics such as sex, age, primary and secondary diagnoses and in-hospital mortality. Based on this information, we recalculate the existing Hospital Frailty Risk Score. The cohort includes patients aged ≥ 75 and was divided into a development cohort (admission year 2011 to 2013, N = 30,525) and a validation cohort (2014, N = 11,202). A limited external validation is also conducted in a second validation cohort containing inpatient cases aged ≥ 75 in 2022 throughout Germany (N = 491,251). In the development cohort, LASSO regression analysis was used to select the most relevant variables and to generate a reweighted Frailty Score for the German setting. Discrimination is assessed using the area under the receiver operating characteristic curve (AUC). Visualization of calibration curves and decision curve analysis were carried out. Applicability of the reweighted Frailty Score in a non-elderly population was assessed using logistic regression models. RESULTS: Reweighting of the Frailty Score included only 53 out of the 109 frailty-related diagnoses and resulted in substantially better discrimination than the initial weighting of the score (AUC = 0.89 vs. AUC = 0.80, p < 0.001 in the validation cohort). Calibration curves show a good agreement between score-based predictions and actual observed mortality. Additional external validation using inpatient cases aged ≥ 75 in 2022 throughout Germany (N = 491,251) confirms the results regarding discrimination and calibration and underlines the geographic and temporal validity of the reweighted Frailty Score. Decision curve analysis indicates that the clinical usefulness of the reweighted score as a general decision support tool is superior to the initial version of the score. Assessment of the applicability of the reweighted Frailty Score in a non-elderly population (N = 198,819) shows that discrimination is superior to the initial version of the score (AUC = 0.92 vs. AUC = 0.87, p < 0.001). In addition, we observe a fairly age-stable influence of the reweighted Frailty Score on in-hospital mortality, which does not differ substantially for women and men. CONCLUSIONS: Our data indicate that the reweighted Frailty Score is superior to the original Frailty Score for identification of older, frail patients at risk for in-hospital mortality. Hence, we recommend using the reweighted Frailty Score in the German in-hospital setting.


Assuntos
Registros Eletrônicos de Saúde , Idoso Fragilizado , Fragilidade , Mortalidade Hospitalar , Humanos , Idoso , Alemanha/epidemiologia , Feminino , Masculino , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Fragilidade/mortalidade , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Medição de Risco/métodos , Mortalidade Hospitalar/tendências , Avaliação Geriátrica/métodos , Fatores de Risco , Hospitalização
7.
J Clin Med ; 13(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38673658

RESUMO

Background: The goal of our study is to evaluate a method to quantify aortic valve calcification (AVC) in contrast-enhanced computed tomography for patients with suspected severe aortic stenosis pre-interventionally. Methods: A total of sixty-five patients with aortic stenosis underwent both a native and a contrast-enhanced computed tomography (CECT) scan of the aortic valve (45 in the training cohort and 20 in the validation cohort) using a standardized protocol. Aortic valve calcification was semi-automatically quantified via the Agatston score method for the native scans and was used as a reference. For contrast-enhanced computed tomography, a calcium threshold of the Hounsfield units of the aorta plus four times the standard deviation was used. Results: For the quantification of aortic valve calcification in contrast-enhanced computed tomography, a conversion formula (691 + 1.83 x AVCCECT) was derived via a linear regression model in the training cohort. The validation in the second cohort showed high agreement for this conversion formula with no significant proportional bias (Bland-Altman, p = 0.055) and with an intraclass correlation coefficient in the validation cohort of 0.915 (confidence interval 95% 0.786-0.966) p < 0.001. Conclusions: Calcium scoring in patients with aortic valve stenosis can be performed using contrast-enhanced computed tomography with high validity. Using a conversion factor led to an excellent agreement, thereby obviating an additional native computed tomography scan. This might contribute to a decrease in radiation exposure.

8.
Diagnostics (Basel) ; 14(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38248031

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary widely in the degree of automation, resulting in differences in terms of reproducibility and time spent. AIM: To compare the reproducibility and time spent of two CCTA analysis software tools using different algorithms for the quantitative assessment of coronary plaque volumes and composition in two independent patient cohorts. METHODS: The study population included 100 patients from two different cohorts: 50 patients from a single-center (Siemens Healthineers, SOMATOM Force (DSCT)) and another 50 patients from a multi-center study (5 different > 64 slice CT scanner types). Quantitative measurements of total calcified and non-calcified plaque volume of the right coronary artery (RCA), left anterior descending (LAD), and left circumflex coronary artery (LCX) were performed on a total of 300 coronaries by two independent readers, using two different CCTA analysis software tools (Tool #1: Siemens Healthineers, syngo.via Frontier CT Coronary Plaque Analysis and Tool #2: Siemens Healthineers, successor CT Coronary Plaque Analysis prototype). In addition, the total time spent for the analysis was recorded with both programs. RESULTS: The patients in cohorts 1 and 2 were 62.8 ± 10.2 and 70.9 ± 11.7 years old, respectively, 10 (20.0%) and 35 (70.0%) were female and 34 (68.0%) and 20 (40.0%), respectively, had hyperlipidemia. In Cohort #1, the inter- and intra-observer variabilities for the assessment of plaque volumes per patient for Tool #1 versus Tool #2 were 22.8%, 22.0%, and 26.0% versus 2.3%, 3.9%, and 2.5% and 19.7%, 21.4%, and 22.1% versus 0.2%, 0.1%, and 0.3%, respectively, for total, noncalcified, and calcified lesions (p < 0.001 for all between Tools #1 and 2 both for inter- and intra-observer). The inter- and intra-observer variabilities using Tool #2 remained low at 2.9%, 2.7%, and 3.0% and 3.8%, 3.7%, and 4.0%, respectively, for total, non-calcified, and calcified lesions in Cohort #2. For each dataset, the median processing time was higher for Tool #1 versus Tool #2 (459.5 s IQR = 348.0-627.0 versus 208.5 s; IQR = 198.0-216.0) (p < 0.001). CONCLUSION: The plaque analysis Tool #2 (CT-guided PCI) encompassing a higher degree of automated support required less manual editing, was more time-efficient, and showed a higher intra- and inter-observer reproducibility for the quantitative assessment of plaque volumes both in a representative single-center and in a multi-center validation cohort.

9.
J Clin Med ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959289

RESUMO

Background: We aimed to evaluate the feasibility of a non-contrast time-of-flight magnetic resonance angiography (TOF-MRA) protocol for the pre-procedural access route assessment of transcatheter aortic valve implantation (TAVI) in comparison with contrast-enhanced cardiac dual-source computed tomography angiography (CTA). Methods and Results: In total, 51 consecutive patients (mean age: 82.69 ± 5.69 years) who had undergone a pre-TAVI cardiac CTA received TOF-MRA for a pre-procedural access route assessment. The MRA image quality was rated as very good (median of 5 [IQR 4-5] on a five-point Likert scale), with only four examinations rated as non-diagnostic. The TOF-MRA systematically underestimated the minimal effective vessel diameter in comparison with CTA (for the effective vessel diameter in mm, the right common iliac artery (CIA)/external iliac artery (EIA)/common femoral artery (CFA) MRA vs. CTA was 8.04 ± 1.46 vs. 8.37 ± 1.54 (p < 0.0001) and the left CIA/EIA/CFA MRA vs. CTA was 8.07 ± 1.32 vs. 8.28 ± 1.34 (p < 0.0001)). The absolute difference between the MRA and CTA was small (for the Bland-Altman analyses in mm, the right CIA/EIA/CFA was -0.36 ± 0.77 and the left CIA/EIA/CFA was -0.25 ± 0.61). The overall correlation between the MRA and CTA measurements was very good (with a Pearson correlation coefficient of 0.87 (p < 0.0001) for the right CIA/EIA/CFA and a Pearson correlation coefficient of 0.9 (p < 0.0001) for the left CIA/EIA/CFA). The feasibility agreement between the MRA and CTA for transfemoral access was good (the right CIA/EIA/CFA agreement was 97.9% and the left CIA/EIA/CFA agreement was 95.7%, Kohen's kappa: 0.477 (p = 0.001)). Conclusions: The TOF-MRA protocol was feasible for the assessment of the access route in an all-comer pre-TAVI population. This protocol might be a reliable technique for patients at an increased risk of contrast-induced nephropathy.

10.
Eur Heart J Cardiovasc Imaging ; 24(12): 1672-1681, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37409579

RESUMO

AIMS: To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically relevant. METHODS AND RESULTS: The study included 100 patients (age: 81.5 ± 5.5 years; female 63%), thereof 50 patients with HALT. After anonymization and randomization, blinded readers measured maximum thrombus thickness per prosthesis (MT_pr) and movement restriction (MR_pr) on electrocardiogram (ECG)-gated whole heart cycle computed tomography angiography. These measurements were compared with echocardiographic mean pressure gradient (mPG), its increase from baseline (ΔmPG), and Doppler velocity index (DVI). Haemodynamic valve deterioration (HVD) was defined as mPG > 20 mmHg. Age, body mass index, valve type, valve size, left ventricular ejection fraction, and atrial fibrillation were considered as influencing factors. Multiple regression analysis revealed that only valve size (P = 0.001) and MT_pr (P = 0.02) had a significant influence on mPG. In an interaction model, valve size moderated the effect of MT_pr on mPG significantly (P = 0.004). Sub-group analysis stratified by valve sizes showed a strong correlation between MT_pr and echocardiographic parameters for 23 mm valves (mPG: r = 0.57, ΔmPG: r = 0.68, DVI: r = 0.55, each with P < 0.001), but neither for 26 nor 29 mm valves (r < 0.2, P > 0.2 for all correlations). Six of seven prostheses with HVD had a 23 mm valve diameter, while one had 29 mm (P = 0.02). CONCLUSION: Early HALT rarely causes significant mPG increase. Our study shows that valve size is a key factor influencing the haemodynamic impact of HALT. In small valve sizes, mPG is more likely to increase. Our study is the first to offer in vivo evidence supporting previous in vitro findings on this topic.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Volume Sistólico , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Masculino
11.
Clin Res Cardiol ; 112(9): 1252-1262, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36928928

RESUMO

BACKGROUND: Evidence on the optimal timing of RA is scarce, although increased periprocedural complications for unplanned procedures have been reported. AIMS: To compare planned versus unplanned use of rotational atherectomy (RA) for plaque modification in patients with severely calcified coronary lesions. METHODS: Procedural and 1-year follow-up data of planned (n = 562 lesions in 448 vessels of 416 patients) and unplanned (n = 490 lesions in 435 vessels of 403 patients) RA between 2008 and 2020 were analyzed using the propensity score methods. The primary composite endpoint was target lesion failure (TLF), defined as cardiovascular death (CVD), target vessel myocardial infarction (TVMI), or target lesion revascularization (TLR). RESULTS: Angiographic success was > 99% in both groups. Fluoroscopy time and contrast volume were significantly lower in planned RA (p < 0.001). Periprocedural complications including slow-flow, coronary dissection, and MI occurred in 4.8% after planned, and in 5.7% after unplanned RA. TLF occurred in 18.5% after planned, and in 14.7% after unplanned RA. Weighted subdistribution hazard ratios for TLFs revealed an unfavorable 1-year outcome for planned RA (sHR 1.62 [1.07-2.45], p = 0.023), which was driven by TLR (sHR 2.01 [1.18-3.46], p = 0.011), but not by CVD, or TVMI. No differences were observed in all-cause mortality. CONCLUSIONS: Unplanned RA was associated with favorable outcome when compared to planned RA. Thus, RA can safely be reserved for lesions that prove untreatable by conventional means. Randomized and prospective trials are needed to evaluate a predominant use of rotational atherectomy as a bailout strategy in the future.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Placa Aterosclerótica , Calcificação Vascular , Humanos , Aterectomia Coronária/efeitos adversos , Aterectomia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Calcificação Vascular/cirurgia , Fatores de Tempo , Angiografia Coronária , Estudos Retrospectivos
12.
JACC Cardiovasc Interv ; 15(11): 1113-1122, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680190

RESUMO

BACKGROUND: Early hypoattenuated leaflet thickening (HALT) occurs in at least 10% of all transcatheter aortic valve replacement (TAVR) patients. The long-term prognostic impact of HALT is uncertain. OBJECTIVES: The aim of this study was to assess the long-term risk of early HALT post-TAVR. METHODS: We report outcome data from our prospective observational registry with post-TAVR computed tomography angiography performed between May 2012 and December 2017. The outcomes were survival, cardiovascular mortality, ischemic cerebrovascular events, and symptomatic hemodynamic valve deterioration. RESULTS: Early HALT was diagnosed in 115 (16.0%) of 804 patients. During a median follow-up of 3.25 years, survival rates did not differ significantly between patients with and without HALT (Kaplan-Meier 3-year estimates for survival 70.1% vs 74.0%, P = 0.597). The 3-year cardiovascular mortality rate was 13.2% versus 11.3% (with vs without HALT, P = 0.733). The 3-year event rate for cerebrovascular events was 2.0% versus 4.4% (with vs without HALT, P = 0.246), and the 3-year event rate of symptomatic hemodynamic valve deterioration was 9.4% versus 1.5% (with vs without HALT, P < 0.001). Multivariable analysis revealed the following predictors of symptomatic hemodynamic valve deterioration: HALT (HR: 6.10; 95% CI: 2.59-14.29; P < 0.001), the mixed valve-type group (HR: 6.51; 95% CI: 2.38-17.81; P < 0.001), and prosthesis diameter (HR valve size per 3 mm [HR: 0.37; 95% CI: 0.17-0.79]; P = 0.011). CONCLUSIONS: During a median follow-up of more than 3 years, HALT was not associated with mortality or cerebrovascular events. However, we observed an association of HALT with symptomatic hemodynamic valve deterioration.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
J Clin Med ; 11(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35456350

RESUMO

BACKGROUND: The impact of transcatheter heart valve (THV) position on the occurrence of paravalvular leakage and permanent pacemaker implantation caused by new-onset conduction disturbances is well described. The purpose of this study was to investigate the influence of the geometry of the thoracic aorta on the implantation depth after TAVI (transcatheter heart valve implantation) using self-expanding valve (SEV) types. METHODS: We evaluated three-dimensional geometry of the thoracic aorta based on computed tomography angiography (CTA) in 104 subsequently patients receiving TAVI with SEV devices (Evolut R). Prosthesis position was determined using the fusion imaging method of pre- and post-procedural CTA. An implantation depth of ≥4 mm was defined as the cut-off value for low prosthesis position. RESULTS: The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm below annulus plane. THV position was low in 66 (63.5%) patients and high in 38 (36.5%) patients. After multivariate adjustment none of the aortic geometry characteristics showed an independent influence on the prosthesis position-neither the Sinus of Valsalva area (p = 0.335) nor the proximal aortic arch diameter (p = 0.754) or the distance from annulus to descending aorta (p = 0.309). CONCLUSION: The geometry of the thoracic aorta showed no influence on the positioning of self-expanding TAVI valve types.

14.
J Clin Med ; 11(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35407425

RESUMO

(1) Background: Early hypo-attenuated leaflet thickening (HALT) is diagnosed by computed tomography angiography (CTA) in approximately 15% of patients undergoing transcatheter aortic valve replacement (TAVR). We sought to investigate the diagnostic performance of CTA for the diagnosis of HALT, focusing on timing data assessment within the cardiac cycle. (2) Methods: The study enrolled 50 patients with and 50 without HALT with available post-TAVR-CTA. The primary objective was to compare the diagnostic performance of CTA readings at specific intervals and time points during the cardiac cycle (entire systole, entire diastole, end-systole, and mid-diastole) versus gold standard (consensus reading by two observers based on multiphase full cardiac cycle data sets). (3) Results: 100 CTAs were independently analysed by two observers blinded to clinical characteristics of the study population and the results from the gold standard reading. Sensitivity and specificity for the diagnosis of HALT were 84%/94% in systole, 87%/92% in diastole, 78%/95% at end-systole, and 80%/94% at mid-diastole. End-systole had the highest positive predictive value (0.88) and positive likelihood ratio (36). Cohen's kappa for interobserver reliability was 0.715 in systole, 0.578 in diastole, 0.650 at end-systole, and 0.517 at mid-diastole. (4) Conclusion: Limiting CTA reading to distinct intervals or time points during the cardiac cycle has good specificity but lowers sensitivity. For a reliable diagnosis of HALT, data sets from a multiphase CTA covering the entire cardiac cycle should be analysed. A double reader approach would be desirable in further studies investigating HALT.

16.
Clin Res Cardiol ; 110(11): 1832-1840, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34448040

RESUMO

OBJECTIVES: We assessed possible myocardial involvement in previously cardiac healthy post-COVID patients referred for persisting symptoms with suspected myocarditis. BACKGROUND: Prior studies suggested myocardial inflammation in patients with coronavirus-induced disease 2019 (COVID-19). However, the prevalence of cardiac involvement among COVID patients varied between 1.4 and 78%. METHODS: A total of 56 post-COVID patients without previous heart diseases were included consecutively into this study. All patients had positive antibody titers against SARS-CoV-2. Patients were referred for persistent symptoms such as chest pain/discomfort, shortness of breath, or intolerance to activity. All patients underwent standardized cardiac assessment including electrocardiogram (ECG), cardiac biomarkers, echocardiography, and cardiac magnetic resonance (CMR). RESULTS: 56 Patients (46 ± 12 years, 54% females) presented 71 ± 66 days after their COVID-19 disease. In most patients, the course of COVID-19 was mild, with hospital treatment being necessary in five (9%). At presentation, patients most often reported persistent fatigue (75%), chest pain (71%), and shortness of breath (66%). Acute myocarditis was confirmed by T1/T2-weighed CMR and elevated NTpro-BNP levels in a single patient (2%). Left ventricular ejection fraction was 56% in this patient. Additional eight patients (14%) showed suspicious CMR findings, including myocardial edema without fibrosis (n = 3), or non-ischemic myocardial injury suggesting previous inflammation (n = 5). However, myocarditis could ultimately not be confirmed according to 2018 Lake Louise criteria; ECG, echo and lab findings were inconspicuous in all eight patients. CONCLUSIONS: Among 56 post-COVID patients with persistent thoracic complaints final diagnosis of myocarditis could be confirmed in a single patient using CMR.


Assuntos
COVID-19/complicações , Coração/virologia , Imageamento por Ressonância Magnética/métodos , Miocardite/virologia , Adulto , COVID-19/diagnóstico , Ecocardiografia , Eletrocardiografia , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
17.
J Clin Med ; 10(12)2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34207892

RESUMO

BACKGROUND: Prior data suggest a correlation between the position of transcatheter heart valves (THV) and the occurrence of complications after transcatheter aortic valve implantation (TAVI) in patients with tricuspid aortic valves (TAV). However, data including a detailed analysis of prosthesis positioning in bicuspid aortic valves (BAV) are limited. Therefore, the purpose of this study was to investigate THV position after TAVI in BAV. METHODS: We evaluated the THV position in 50 BAV and 50 TAV patients (all received the balloon-expandable Sapien 3 prosthesis) using fusion imaging of pre- and post-procedural computed tomography angiography. According to the manufacturers' recommendations, a low implantation position was defined as >30% of the prosthesis below the annulus. RESULTS: THV position was appropriate in the majority of the patients within both groups (90.0% for BAV vs. 96.0% for TAV, p = 0.240). In BAV, we observed a more pronounced THV waist (7.4 ± 4.5% vs. 5.8 ± 3.0%, p = 0.043) and a lower average THV expansion (91.9 ± 12.2% vs. 95.5 ± 2.7% of nominal expansion, p = 0.044). CONCLUSIONS: Accurate positioning in relation to the aortic annulus of the TAVI Sapien 3 prosthesis is possible in patients with BAV with results comparable to TAV. However, there is a more pronounced prosthesis waist and a lower average THV expansion in BAV.

18.
JACC Cardiovasc Interv ; 14(14): 1578-1590, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34294400

RESUMO

OBJECTIVES: The aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR). BACKGROUND: Impaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences. METHODS: In this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected. A total of 449 patients from 25 sites with acute coronary syndromes (89.1%) and other acute cardiovascular situations (10.9%) were included. RESULTS: Success rates were high for CA of the right coronary artery (98.3%) and left coronary artery (99.3%) and were higher among patients with short stent-frame prostheses (SFPs) than in those with long SFPs for CA of the right coronary artery (99.6% vs 95.9%; P = 0.005) but not for CA of the left coronary artery (99.7% vs 98.7%; P = 0.24). PCI of native coronary arteries was successful in 91.4% of cases and independent of valve type (short SFP 90.4% vs long SFP 93.4%; P = 0.44). Guide engagement failed in 6 patients, of whom 3 underwent emergent coronary artery bypass grafting and another 3 died in the hospital. Among patients requiring revascularization of native vessels, independent predictors of 30-day all-cause mortality were prior diabetes, cardiogenic shock, and failed PCI but not valve type or success of coronary engagement. CONCLUSIONS: CA or PCI after TAVR in acute settings is usually successful, but selective coronary engagement may be more challenging in the presence of long SFPs. Among patients requiring PCI, prior diabetes, cardiogenic shock, and failed PCI were predictors of early mortality.


Assuntos
Síndrome Coronariana Aguda , Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Estudos de Viabilidade , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Int J Cardiovasc Imaging ; 37(10): 3081-3092, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33988801

RESUMO

Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P < 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI] 1.312[1.119-1.539], P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Clin Res Cardiol ; 110(1): 93-101, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32399896

RESUMO

BACKGROUND: Low prosthesis position after transcatheter aortic valve implantation (TAVI) is associated with higher rates of new onset conduction disturbances and permanent pacemaker implantations. Purpose of this study was to investigate possible predictors of a low prosthesis position of the SAPIEN 3 (Edwards Lifesciences, Irvine, California, USA) valve type using fusion imaging of pre- and post-procedural computed tomography angiography (CTA). METHODS: CTA fusion imaging was performed in 120 TAVI-patients with 3D-reconstruction of the transcatheter heart valve (THV) position within the device landing zone. A low implantation position was defined according to the manufacturer's recommendations as > 30% of the prosthesis below the native annulus plane. RESULTS: A low THV position was found in 17 patients (14%). Patients with low THV position had less calcification of the annulus region and a smaller annulus size compared to patients with a normal or high THV position (P = 0.003 and 0.041, respectively). The only independent predictor of a low THV position in multivariate logistic regression analysis was the extent of calcification of the cusp region (odds ratio [CI] 0.842 [0.727-0.976], P = 0.022). CONCLUSIONS: Fusion imaging of pre-and post-procedural CTA identified reduced calcification of the cusp region as an independent predictor of a low THV position of the SAPIEN 3. This should be considered when planning the TAVI procedure. Correlation of cusp region calcification and prosthesis position after TAVI.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Período Pós-Operatório , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...