Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Acta Neurochir (Wien) ; 166(1): 209, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727725

RESUMO

Based on a personal experience of 4200 surgeries, radiofrequency thermocoagulation is useful lesional treatment for those trigeminal neuralgias (TNs) not amenable to microvascular decompression (idiopathic or secondary TNs). Introduced through the foramen ovale, behind the trigemnial ganglion in the triangular plexus, the needle is navigated by radiology and neurophysiological testing to target the retrogasserian fibers corresponding to the trigger zone. Heating to 55-75 °C can achieve hypoesthesia without anaesthesia dolorosa if properly controlled. Depth of anaesthesia varies dynamically sedation for cannulation and lesioning, and awareness during neurophysiologic navigation. Proper technique ensures long-lasting results in more than 75% of patients.


Assuntos
Eletrocoagulação , Neuralgia do Trigêmeo , Neuralgia do Trigêmeo/cirurgia , Neuralgia do Trigêmeo/diagnóstico por imagem , Humanos , Eletrocoagulação/métodos , Nervo Trigêmeo/cirurgia , Forame Oval/cirurgia , Forame Oval/diagnóstico por imagem , Gânglio Trigeminal/cirurgia , Cirurgia de Descompressão Microvascular/métodos , Resultado do Tratamento
2.
Rev Neurol (Paris) ; 177(3): 283-289, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32305140

RESUMO

BACKGROUND: Little is known about outcome and settings adaptations after replacement of constant-voltage non-rechargeable implantable pulse generator (CV-nrIPG) by constant-current rechargeable IPG (CC-rIPG). OBJECTIVE: To determine the feasibility and safety of replacing a CV-nrIPG by a CC-rIPG in Parkinson's disease (PD) and the subsequent outcome. METHODS: A prospective cohort of thirty PD patients, whose CV-nrIPG was replaced by a CC-rIPG in University Hospital of Lyon between January 2017 and December 2018 (rIPG group) and 39 PD patients, who underwent the replacement of a CV-nrIPG by the same device in 2016 (nrIPG group), were enrolled in this study. Three surgeons performed the operations. Duration of hospitalization for the replacement as well as the number of in or outpatient visits during the first 3 months after the surgery were recorded. In the rIPG group, we compared preoperative DBS settings and the theoretical amplitude estimated using Ohm's law to the amplitude used at the end of follow-up. We assessed patients' and clinicians' opinion on the patient global functioning after the replacement using Clinical Global Impression score. RESULTS: Duration of hospitalization (P=0.47) and need for additional hospitalizations (P=0.73) or consultations (P=0.71) to adapt DBS parameters did not differ between the two groups. Neurological condition (CGI score) was considered as unchanged by both patients and neurologists. Final amplitude of stimulation using CC-rIPG was not predicted by Ohm's law in most cases. CONCLUSIONS: Replacing CV-nrIPG by CC-rIPG is safe and well tolerated but require neurological expertise to set the new parameters of stimulation.


Assuntos
Doença de Parkinson , Estimulação Encefálica Profunda , Eletrodos Implantados , Estudos de Viabilidade , Humanos , Doença de Parkinson/terapia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...