Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Sci Rep ; 14(1): 20739, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39237605

RESUMO

Indoor air quality is negatively affected by the emission of different combustion sources releasing airborne particles and related particle-bound toxic compounds (e.g., heavy metals and polycyclic aromatic hydrocarbons). To date, very few studies focused on the chemical characterization of the airborne particles emitted by indoor sources were carried out; moreover, no data on their size-resolved chemical compositions are available. In the present study, an experimental analysis aimed at determining the size-segregated content of heavy metals and polycyclic aromatic hydrocarbons in airborne particles (including sub-micrometric ones) emitted by widely-used indoor combustion sources (i.e., incenses, candles, mosquito-coils, and cooking activities) was carried out. To this purpose, airborne particles were collected through an electric low-pressure impactor and were post-analyzed by means of chromatography-mass spectrometry and atomic emission spectrometry techniques. Results of the analyses showed that the chemical composition of the emitted particles is not invariant to the particle size, indeed, an important contribution of sub-micrometric particle range to the total mass of chemical compounds emitted by the sources was noticed. These findings also demonstrated that significant underestimations of particle-bound compounds depositing in the lungs could occur if size-dependent compositions are not adopted.

2.
Atmos Pollut Res ; 13(7): 101473, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35692900

RESUMO

The spread of respiratory diseases via aerosol particles in indoor settings is of significant concern. The SARS-CoV-2 virus has been found to spread widely in confined enclosures like hotels, hospitals, cruise ships, prisons, and churches. Particles exhaled from a person indoors can remain suspended long enough for increasing the opportunity for particles to spread spatially. Careful consideration of the ventilation system is essential to minimise the spread of particles containing infectious pathogens. Previous studies have shown that indoor airflow induced by opened windows would minimise the spread of particles. However, how outdoor airflow through an open window influences the indoor airflow has not been considered. The aim of this study is to provide a clear understanding of the indoor particle spread across multiple rooms, in a situation similar to what is found in quarantine hotels and cruise ships, using a combination of HVAC (Heating, Ventilation and Air-Conditioning) ventilation and an opening window. Using a previously validated mathematical model, we used 3D CFD (computational fluid dynamics) simulations to investigate to what extent different indoor airflow scenarios contribute to the transport of a single injection of particles ( 1 . 3 µ m ) in a basic 3D multi-room indoor environment. Although this study is limited to short times, we demonstrate that in certain conditions approximately 80% of the particles move from one room to the corridor and over 60% move to the nearby room within 5 to 15 s. Our results provide additional information to help identifying relevant recommendations to limit particles from spreading in enclosures.

3.
J Hazard Mater ; 428: 128279, 2022 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-35063838

RESUMO

The airborne transmission of SARS-CoV-2 remains surprisingly controversial; indeed, health and regulatory authorities still require direct proof of this mode of transmission. To close this gap, we measured the viral load of SARS-CoV-2 of an infected subject in a hospital room (through an oral and nasopharyngeal swab), as well as the airborne SARS-CoV-2 concentration in the room resulting from the person breathing and speaking. Moreover, we simulated the same scenarios to estimate the concentration of RNA copies in the air through a novel theoretical approach and conducted a comparative analysis between experimental and theoretical results. Results showed that for an infected subject's viral load ranging between 2.4 × 106 and 5.5 × 106 RNA copies mL-1, the corresponding airborne SARS-CoV-2 concentration was below the minimum detection threshold when the person was breathing, and 16.1 (expanded uncertainty of 32.8) RNA copies m-3 when speaking. The application of the predictive approach provided concentrations metrologically compatible with the available experimental data (i.e. for speaking activity). Thus, the study presented significant evidence to close the gap in understanding airborne transmission, given that the airborne SARS-CoV-2 concentration was shown to be directly related to the SARS-CoV-2 emitted. Moreover, the theoretical analysis was shown to be able to quantitatively link the airborne concentration to the emission.


Assuntos
Microbiologia do Ar , COVID-19 , SARS-CoV-2 , Aerossóis , COVID-19/virologia , Humanos , Carga Viral
4.
Environ Sci Technol ; 56(2): 1125-1137, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34985868

RESUMO

Some infectious diseases, including COVID-19, can undergo airborne transmission. This may happen at close proximity, but as time indoors increases, infections can occur in shared room air despite distancing. We propose two indicators of infection risk for this situation, that is, relative risk parameter (Hr) and risk parameter (H). They combine the key factors that control airborne disease transmission indoors: virus-containing aerosol generation rate, breathing flow rate, masking and its quality, ventilation and aerosol-removal rates, number of occupants, and duration of exposure. COVID-19 outbreaks show a clear trend that is consistent with airborne infection and enable recommendations to minimize transmission risk. Transmission in typical prepandemic indoor spaces is highly sensitive to mitigation efforts. Previous outbreaks of measles, influenza, and tuberculosis were also assessed. Measles outbreaks occur at much lower risk parameter values than COVID-19, while tuberculosis outbreaks are observed at higher risk parameter values. Because both diseases are accepted as airborne, the fact that COVID-19 is less contagious than measles does not rule out airborne transmission. It is important that future outbreak reports include information on masking, ventilation and aerosol-removal rates, number of occupants, and duration of exposure, to investigate airborne transmission.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Aerossóis , Surtos de Doenças , Humanos , SARS-CoV-2 , Ventilação
5.
Geosci Front ; 13(6): 101398, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37521135

RESUMO

Public transport environments are thought to play a key role in the spread of SARS-CoV-2 worldwide. Indeed, high crowding indexes (i.e. high numbers of people relative to the vehicle size), inadequate clean air supply, and frequent extended exposure durations make transport environments potential hotspots for transmission of respiratory infections. During the COVID-19 pandemic, generic mitigation measures (e.g. physical distancing) have been applied without also considering the airborne transmission route. This is due to the lack of quantified data about airborne contagion risk in transport environments. In this study, we apply a novel combination of close proximity and room-scale risk assessment approaches for people sharing public transport environments to predict their contagion risk due to SARS-CoV-2 respiratory infection. In particular, the individual infection risk of susceptible subjects and the transmissibility of SARS-CoV-2 (expressed through the reproduction number) are evaluated for two types of buses, differing in terms of exposure time and crowding index: urban and long-distance buses. Infection risk and reproduction number are calculated for different scenarios as a function of the ventilation rates (both measured and estimated according to standards), crowding indexes, and travel times. The results show that for urban buses, the close proximity contribution significantly affects the maximum occupancy to maintain a reproductive number of <1. In particular, full occupancy of the bus would be permitted only for an infected subject breathing, whereas for an infected subject speaking, masking would be required. For long-distance buses, full occupancy of the bus can be maintained only if specific mitigation solutions are simultaneously applied. For example, for an infected person speaking for 1 h, appropriate filtration of the recirculated air and simultaneous use of FFP2 masks would permit full occupancy of the bus for a period of almost 8 h. Otherwise, a high percentage of immunized persons (>80%) would be needed.

6.
BMC Infect Dis ; 21(1): 1193, 2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34836502

RESUMO

BACKGROUND: Effective vaccines are now available for SARS-CoV-2 in the 2nd year of the COVID-19 pandemic, but there remains significant uncertainty surrounding the necessary vaccination rate to safely lift occupancy controls in public buildings and return to pre-pandemic norms. The aim of this paper is to estimate setting-specific vaccination thresholds for SARS-CoV-2 to prevent sustained community transmission using classical principles of airborne contagion modeling. We calculated the airborne infection risk in three settings, a classroom, prison cell block, and restaurant, at typical ventilation rates, and then the expected number of infections resulting from this risk at varying percentages of occupant immunity. RESULTS: We estimate the setting-specific immunity threshold for control of wild-type SARS-CoV-2 to range from a low of 40% for a mechanically ventilation classroom to a high of 85% for a naturally ventilated restaurant. CONCLUSIONS: If vaccination rates are limited to a theoretical minimum of approximately two-thirds of the population, enhanced ventilation above minimum standards for acceptable air quality is needed to reduce the frequency and severity of SARS-CoV-2 superspreading events in high-risk indoor environments.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Vacinação , Ventilação
7.
Sci Total Environ ; 794: 148749, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34225157

RESUMO

Although the interpersonal distance represents an important parameter affecting the risk of infection due to respiratory viruses, the mechanism of exposure to exhaled droplets remains insufficiently characterized. In this study, an integrated risk assessment is presented for SARS-CoV-2 close proximity exposure between a speaking infectious subject and a susceptible subject. It is based on a three-dimensional transient numerical model for the description of exhaled droplet spread once emitted by a speaking person, coupled with a recently proposed SARS-CoV-2 emission approach. Particle image velocimetry measurements were conducted to validate the numerical model. The contribution of the large droplets to the risk is barely noticeable only for distances well below 0.6 m, whereas it drops to zero for greater distances where it depends only on airborne droplets. In particular, for short exposures (10 s) a minimum safety distance of 0.75 m should be maintained to lower the risk below 0.1%; for exposures of 1 and 15 min this distance increases to about 1.1 and 1.5 m, respectively. Based on the interpersonal distances across countries reported as a function of interacting individuals, cultural differences, and environmental and sociopsychological factors, the approach presented here revealed that, in addition to intimate and personal distances, particular attention must be paid to exposures longer than 1 min within social distances (of about 1 m).


Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , COVID-19/transmissão , Expiração , Humanos , Medição de Risco
8.
Build Environ ; 202: 108042, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34127877

RESUMO

Reducing the transmission of SARS-CoV-2 through indoor air is the key challenge of the COVID-19 pandemic. Crowded indoor environments, such as schools, represent possible hotspots for virus transmission since the basic non-pharmaceutical mitigation measures applied so far (e.g. social distancing) do not eliminate the airborne transmission mode. There is widespread consensus that improved ventilation is needed to minimize the transmission potential of airborne viruses in schools, whether through mechanical systems or ad-hoc manual airing procedures in naturally ventilated buildings. However, there remains significant uncertainty surrounding exactly what ventilation rates are required, and how to best achieve these targets with limited time and resources. This paper uses a mass balance approach to quantify the ability of both mechanical ventilation and ad-hoc airing procedures to mitigate airborne transmission risk in the classroom environment. For naturally-ventilated classrooms, we propose a novel feedback control strategy using CO2 concentrations to continuously monitor and adjust the airing procedure. Our case studies show how such procedures can be applied in the real world to support the reopening of schools during the pandemic. Our results also show the inadequacy of relying on absolute CO2 concentration thresholds as the sole indicator of airborne transmission risk.

9.
J Hosp Infect ; 110: 89-96, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33453351

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has caused untold disruption throughout the world. Understanding the mechanisms for transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is key to preventing further spread, but there is confusion over the meaning of 'airborne' whenever transmission is discussed. Scientific ambivalence originates from evidence published many years ago which has generated mythological beliefs that obscure current thinking. This article collates and explores some of the most commonly held dogmas on airborne transmission in order to stimulate revision of the science in the light of current evidence. Six 'myths' are presented, explained and ultimately refuted on the basis of recently published papers and expert opinion from previous work related to similar viruses. There is little doubt that SARS-CoV-2 is transmitted via a range of airborne particle sizes subject to all the usual ventilation parameters and human behaviour. Experts from specialties encompassing aerosol studies, ventilation, engineering, physics, virology and clinical medicine have joined together to produce this review to consolidate the evidence for airborne transmission mechanisms, and offer justification for modern strategies for prevention and control of COVID-19 in health care and the community.


Assuntos
Aerossóis , Microbiologia do Ar , COVID-19/prevenção & controle , COVID-19/transmissão , Controle de Infecções/métodos , Pandemias/prevenção & controle , Ventilação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2
10.
Environ Int ; 145: 106112, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32927282

RESUMO

Airborne transmission is a recognized pathway of contagion; however, it is rarely quantitatively evaluated. The numerous outbreaks that have occurred during the SARS-CoV-2 pandemic are putting a demand on researchers to develop approaches capable of both predicting contagion in closed environments (predictive assessment) and analyzing previous infections (retrospective assessment). This study presents a novel approach for quantitative assessment of the individual infection risk of susceptible subjects exposed in indoor microenvironments in the presence of an asymptomatic infected SARS-CoV-2 subject. The application of a Monte Carlo method allowed the risk for an exposed healthy subject to be evaluated or, starting from an acceptable risk, the maximum exposure time. We applied the proposed approach to four distinct scenarios for a prospective assessment, highlighting that, in order to guarantee an acceptable risk of 10-3 for exposed subjects in naturally ventilated indoor environments, the exposure time could be well below one hour. Such maximum exposure time clearly depends on the viral load emission of the infected subject and on the exposure conditions; thus, longer exposure times were estimated for mechanically ventilated indoor environments and lower viral load emissions. The proposed approach was used for retrospective assessment of documented outbreaks in a restaurant in Guangzhou (China) and at a choir rehearsal in Mount Vernon (USA), showing that, in both cases, the high attack rate values can be justified only assuming the airborne transmission as the main route of contagion. Moreover, we show that such outbreaks are not caused by the rare presence of a superspreader, but can be likely explained by the co-existence of conditions, including emission and exposure parameters, leading to a highly probable event, which can be defined as a "superspreading event".


Assuntos
Infecções por Coronavirus/transmissão , Coronavirus , Pneumonia Viral/transmissão , Medição de Risco/métodos , Aerossóis , Poluição do Ar em Ambientes Fechados , Betacoronavirus , COVID-19 , China , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Humanos , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Estudos Prospectivos , Estudos Retrospectivos , SARS-CoV-2
11.
Environ Int ; 141: 105794, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32416374

RESUMO

Airborne transmission is a pathway of contagion that is still not sufficiently investigated despite the evidence in the scientific literature of the role it can play in the context of an epidemic. While the medical research area dedicates efforts to find cures and remedies to counteract the effects of a virus, the engineering area is involved in providing risk assessments in indoor environments by simulating the airborne transmission of the virus during an epidemic. To this end, virus air emission data are needed. Unfortunately, this information is usually available only after the outbreak, based on specific reverse engineering cases. In this work, a novel approach to estimate the viral load emitted by a contagious subject on the basis of the viral load in the mouth, the type of respiratory activity (e.g. breathing, speaking, whispering), respiratory physiological parameters (e.g. inhalation rate), and activity level (e.g. resting, standing, light exercise) is proposed. The results showed that high quanta emission rates (>100 quanta h-1) can be reached by an asymptomatic infectious SARS-CoV-2 subject performing vocalization during light activities (i.e. walking slowly) whereas a symptomatic SARS-CoV-2 subject in resting conditions mostly has a low quanta emission rate (<1 quantum h-1). The findings in terms of quanta emission rates were then adopted in infection risk models to demonstrate its application by evaluating the number of people infected by an asymptomatic SARS-CoV-2 subject in Italian indoor microenvironments before and after the introduction of virus containment measures. The results obtained from the simulations clearly highlight that a key role is played by proper ventilation in containment of the virus in indoor environments.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Infecções por Coronavirus/transmissão , Pneumonia Viral/transmissão , Betacoronavirus , COVID-19 , Expiração , Humanos , Itália , Boca/virologia , Pandemias , Medição de Risco , SARS-CoV-2 , Carga Viral
12.
Environ Int ; 138: 105670, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32203802

RESUMO

Ship traffic emissions degrade air quality in coastal areas and contribute to climate impacts globally. The estimated health burden of exposure to shipping emissions in coastal areas may inform policy makers as they seek to reduce exposure and associated potential health impacts. This work estimates the PM2.5-attributable impacts in the form of premature mortality and cardiovascular and respiratory hospital admissions, from long-term exposure to shipping emissions. Health impact assessment (HIA) was performed in 8 Mediterranean coastal cities, using a baseline conditions from the literature and a policy case accounting for the MARPOL Annex VI rules requiring cleaner fuels in 2020. Input data were (a) shipping contributions to ambient PM2.5 concentrations based on receptor modelling studies found in the literature, (b) population and health incidence data from national statistical registries, and (c) geographically-relevant concentration-response functions from the literature. Long-term exposure to ship-sourced PM2.5 accounted for 430 (95% CI: 220-650) premature deaths per year, in the 8 cities, distributed between groups of cities: Barcelona and Athens, with >100 premature deaths/year, and Nicosia, Brindisi, Genoa, Venice, Msida and Melilla, with tens of premature deaths/year. The more stringent standards in 2020 would reduce the number of PM2.5-attributable premature deaths by 15% on average. HIA provided a comparative assessment of the health burden of shipping emissions across Mediterranean coastal cities, which may provide decision support for urban planning with a special focus on harbour areas, and in view of the reduction in sulphur content of marine fuels due to MARPOL Annex VI in 2020.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/toxicidade , Poluição do Ar/análise , Cidades , Humanos , Região do Mediterrâneo , Material Particulado/análise , Material Particulado/toxicidade
13.
Sci Total Environ ; 712: 135673, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-31810696

RESUMO

Indoor school gyms are environments characterized by high concentrations of different airborne particulate and gaseous pollutants. In particular, like other naturally-ventilated school environments, in addition to indoor pollutants children can be exposed to sub-micron particles and gaseous pollutants emitted by outdoor sources and penetrating the building envelope; moreover, high concentrations of super-micron particles can be reached due to the resuspension phenomena related to the physical activity performed therein. The present paper aims to evaluate the effect of different ventilation methods (natural ventilation, manual airing) and the use of air purifiers in reducing the indoor concentrations of different airborne particles and gaseous pollutants in school gyms. To this end, an experimental campaign was performed in two naturally-ventilated school gyms in Barcelona (Spain) of different volumes and different distance to major urban roads. Indoor and outdoor measurements of particle number, black carbon and PM1-10 concentrations were performed as well as indoor measurements of CO2 and NO2 concentrations. The study revealed that the use of air purifiers with windows kept closed (natural ventilation) can lead to a significant reduction in terms of indoor-to-outdoor concentration ratios. In the smaller gym (air changes per hour of the purifiers, ACH, equal to 9.2 h-1) the I/O ratios were reduced by 93% and 95% in terms of particle number and PM1-10, respectively; whereas in the larger school gym (ACH = 1.7 h-1) the corresponding reductions were 70% and 84%. For manual airing scenarios, the effect of the air purifiers on outdoor-generated sub-micron particles is reduced; in particular, for low ACH values (i.e. ACH = 1.7 h-1), the reduction is quite negligible (6%).


Assuntos
Filtros de Ar , Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Criança , Monitoramento Ambiental , Gases , Humanos , Tamanho da Partícula , Material Particulado , Instituições Acadêmicas , Espanha , Ventilação
14.
Waste Manag ; 101: 9-17, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31586878

RESUMO

The paper is focused on the emission of sub-micron particles from incinerator plants characterized by different treatment sections. In particular, measurement of particle number concentrations and distributions in different sampling points of the flue-gas treatment sections, and/or over several years, allowed to detect, for the very first time through in-field tests, the effect of the age of the fabric filter bags and of the SCR system on the emission of sub-micron particles. In fact, tests showed that the age of the fabric filter bags can affect the particle number concentrations at the stack: indeed, for older bags higher concentrations at the stack were measured likely due to the filter cleaning process. Concerning the effect of the SCR system, the natural gas combustion performed in the SCR system leads to an increase of sub-micron particle concentrations at the stack with respect to the values measured after the filtration section.


Assuntos
Poluentes Atmosféricos , Incineração , Filtração , Tamanho da Partícula
15.
Sci Total Environ ; 656: 1032-1042, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30625635

RESUMO

Air quality still represents a main threat to human health in cities. Even in developed countries, decades of air pollution control not yet allowed to reduce pollutant concentrations in urban areas adequately. Indeed, high airborne particle concentrations are measured in several European cities; this is a main issue since particles represent a carrier for carcinogenic compounds. Numerous researches measuring the exposure to the different aerosol metrics in urban areas were recently performed, nonetheless, few data on the lung cancer risk in such environments are available. In the present paper a novel approach to evaluate the lung cancer risk related to the airborne particles emitted by the different sources located in a city is proposed and applied to a pilot case-study (i.e. an Italian city). In particular, an existing lung cancer risk model was modified and applied to assess the particle-related lung cancer "emitted" by the different sources of the city using pollutant emission factors provided by accredited emission inventory databases. Therefore, the average toxicity of the particles emitted by the city (i.e. lung cancer slope factor) and the lung cancer risk globally emitted by the city, expressed as new cases of lung cancer, were evaluated. The proposed emission inventory also allowed to identify and localize the main contributors to the overall risk emitted in a city. As an example, for the city under investigation, the research revealed that the main contributor, amongst the sources considered, is the vehicular traffic which is characterized by a lower mass fraction of carcinogenic compounds but a much higher sub-micron particle emission with respect to the other sources.


Assuntos
Poluentes Atmosféricos/efeitos adversos , Carcinógenos/toxicidade , Monitoramento Ambiental/métodos , Gases/efeitos adversos , Neoplasias Pulmonares/epidemiologia , Material Particulado/efeitos adversos , Cidades/epidemiologia , Humanos , Itália/epidemiologia , Neoplasias Pulmonares/induzido quimicamente , Tamanho da Partícula , Medição de Risco/métodos
16.
Sci Total Environ ; 650(Pt 1): 1582-1590, 2019 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-30308844

RESUMO

Cycling and walking are promoted as means of transportation which can contribute to the reduction of traffic pollution in urban areas. However, cyclists and pedestrians may be exposed to high concentrations of air pollutants due to their proximity to vehicle emissions. Commercial face mask respirators are widely used, in both developing and developed countries, as an individual protective measure against particle pollution. However scientific data on the efficacy of face mask respirators in reducing airborne particle exposure is limited. In this study, a custom experimental set-up was developed in order to measure the effectiveness of nine different respirators under real environmental conditions in terms of particle mass concentration below 2.5 µm (PM2.5), particle number concentration (PNC), Lung Deposited Surface Area (LDSA) and Black Carbon concentration (BC). Face mask performances were assessed in a typical traffic affected urban background environment in the city of Barcelona under three different simulated breathing rates to investigate the influence of flow rate. Results showed a median face mask effectiveness for PM2.5 equal to 48% in a range of 14-96%, 19% in a range of 6%-61% for BC concentration, 19% in a range of 4%-63% for PNC and 22% in a range of 5%-65% for LDSA. For each pollutant under investigation, the best performance was found always with the same mask (N7) although it is not the most expensive (in a range of price of 1 to 44, its cost was 20 euros), which has a filter on the entire surface except for the 2 exhalation valves where air cannot enter but just exit and shows a good fit on the dummy head.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Exposição por Inalação/prevenção & controle , Máscaras , Material Particulado/análise , Cidades , Humanos , Exposição por Inalação/estatística & dados numéricos , Roupa de Proteção , Emissões de Veículos/análise
17.
Environ Pollut ; 240: 248-254, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29747109

RESUMO

Smoking activities were recognized as a main risk factor for population. Indeed, mainstream smoke aerosol is directly inhaled by smokers then delivering harmful compounds in the deepest regions of the lung. In order to reduce the potential risk of smoking, different nicotine delivery products have been recently developed. The latest device released is an electrically heated tobacco system (iQOS®, Philip Morris) which is able to warm the tobacco with no combustion. In the present paper a dimensional and volatility characterization of iQOS-generated particles was performed through particle number concentration and distribution measurements in the mainstream aerosol. The experimental analysis was carried out through a condensation particle counter, a fast mobility particle sizer and a thermo-dilution sampling system allowing aerosol samplings at different temperatures. Estimates of the particle surface area dose received by smokers were also carried out on the basis of measured data and typical smoking patterns. The particle number concentrations in the mainstream aerosols resulted lower than 1 × 108 part. cm-3 with particle number distribution modes of about 100 nm. Nonetheless, the volatility analysis showed the high amount of volatile fraction of iQOS-generated particles, indeed, samplings performed at 300 °C confirmed a significant particle shrinking phenomena (modes of about 20 nm). Anyway, the particle number concentration does not statistically decrease at higher sampling temperatures, then showing that a non-volatile fraction is always presents in the emitted particles. The dose received by smokers in terms of non-volatile amount of particle surface area was equal to 1-2 mm2 per puff, i.e. up to 4-fold larger than that received by electronic cigarette vapers.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Sistemas Eletrônicos de Liberação de Nicotina , Fumaça/análise , Eletricidade , Temperatura Alta , Humanos , Pulmão/química , Nicotina/análise , Tamanho da Partícula , Fumar , Nicotiana , Produtos do Tabaco , Fumar Tabaco , Volatilização
18.
Sci Total Environ ; 631-632: 1109-1116, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29727937

RESUMO

Combustion-generated nanoparticles are responsible for negative health effects due to their ability to penetrate in the lungs, carrying toxic compounds with them. In urban areas, the coexistence of nanoparticle sources and particular street-building configurations can lead to very high particle exposure levels. In the present paper, an innovative approach for the evaluation of lung cancer incidence in street canyon due to exposure to traffic-generated particles was proposed. To this end, the literature-available values of particulate matter, PAHs and heavy metals emitted from different kind of vehicles were used to calculate the Excess Lifetime Cancer Risk (ELCR) at the tailpipe. The estimated ELCR was then used as input data in a numerical CFD (Computational Fluid Dynamics) model that solves the mass, momentum, turbulence and species transport equations, in order to evaluate the cancer risk in every point of interest inside the street canyon. Thus, the influence of wind speed and street canyon geometry (H/W, height of building, H and width of the street, W) on the ELCR at street level was evaluated by means of a CFD simulation. It was found that the ELCR calculated on the leeward and windward sides of the street canyon at a breathable height of 1.5 m, for people exposed 15 min per day for 20 years, is equal to 1.5 × 10-5 and 4.8 × 10-6, respectively, for wind speed of 1 m/s and H/W equal to 1. The ELCR at street level results higher on the leeward side for aspect ratios equal to 1 and 3, while for aspect ratio equal to 2 it is higher on the windward side. In addition, the simulations showed that with the increasing of wind speed the ELCR becomes lower everywhere in the street canyon, due to the increased in dispersion.


Assuntos
Poluição do Ar/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Modelos Teóricos , Poluentes Atmosféricos/análise , Cidades/epidemiologia , Humanos , Metais Pesados , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Medição de Risco , Emissões de Veículos/análise , Vento
19.
Sci Total Environ ; 616-617: 720-729, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29089125

RESUMO

Schools represent a critical microenvironment in terms of air quality due to the proximity to outdoor particle sources and the frequent lack of proper ventilation and filtering systems. Moreover, the population exposed in schools (i.e. children) represents a susceptible population due to their age. Air quality-based studies involving students' exposure at schools are still scarce and often limited to mass-based particle metrics and may thus underestimate the possible effect of sub-micron particles and particle toxicity. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured inside and outside schools in Barcelona (Spain) and Cassino (Italy). Simultaneously, PM samples were collected and chemically analysed to obtain mass fractions of carcinogenic compounds. School time airborne particle doses received by students in classrooms were evaluated as well as their excess lung cancer risk due to a five-year primary school period. Median surface area dose received by students during school time in Barcelona and Cassino resulted equal to 110mm2 and 303mm2, respectively. The risk related to the five-year primary school period was estimated as about 2.9×10-5 and 1.4×10-4 for students of Barcelona and Cassino, respectively. The risk in Barcelona is slightly higher with respect to the maximum tolerable value (10-5, according to the U.S. Environmental Protection Agency), mainly due to toxic compounds on particles generated from anthropogenic emissions (mainly industry). On the other hand, the excess lung cancer risk in Cassino is cause of concern, being one order of magnitude higher than the above-mentioned threshold value due to the presence of biomass burning heating systems and winter thermal inversion that cause larger doses and great amount of toxic compounds on particles.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar , Criança , Europa (Continente) , Humanos , Itália/epidemiologia , Instituições Acadêmicas , Espanha/epidemiologia
20.
Environ Pollut ; 235: 65-73, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29274539

RESUMO

Homes represent a critical microenvironment in terms of air quality due to the proximity to main particle sources and the lack of proper ventilation systems. Biomass-fed heating systems are still extensively used worldwide, then likely emitting a significant amount of particles in indoor environments. Nonetheless, research on biomass emissions are limited to their effects on outdoor air quality then not properly investigating the emission in indoor environments. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds in dwellings where three different heating systems were used: open fireplaces, closed fireplaces and pellet stoves. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured during the biomass combustion activities, moreover, PM10 samples were collected and chemically analyzed to obtain mass fractions of carcinogenic compounds attached onto particles. Airborne particle doses received by people exposed in such environments were evaluated as well as their excess lung cancer risk. Most probable surface area extra-doses received by people exposed to open fireplaces on hourly basis (56 mm2 h-1) resulted one order of magnitude larger than those experienced for exposure to closed fireplaces and pellet stoves. Lifetime extra risk of Italian people exposed to the heating systems under investigation were larger than the acceptable lifetime risk (10-5): in particular, the risk due to the open fireplace (8.8 × 10-3) was non-negligible when compared to the overall lung cancer risk of typical Italian population.


Assuntos
Poluentes Atmosféricos/toxicidade , Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Calefação , Neoplasias Pulmonares/epidemiologia , Poluentes Atmosféricos/análise , Biomassa , Humanos , Tamanho da Partícula , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...