Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Eur Rev Med Pharmacol Sci ; 27(21): 10716-10729, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37975397

RESUMO

OBJECTIVE: Combination and duration of antithrombotic therapy in order to prevent both stent thrombosis and thromboembolic complications after coronary artery stenting (PCI) in non-valvular atrial fibrillation (AF) is still debated. This uncertainty can be attributed mainly to the fact that the reference trials were open-label and not adequately powered in order to reach a definitive conclusion on ischemic endpoints (i.e., stent thrombosis). On these grounds, data from real-life studies could support evidence on dual antithrombotic treatment (DAT) safety (bleeding risk) and efficacy (stent thrombosis prevention). The aim of the meta-analysis is to investigate in both randomized controlled trials (RCTs) and observational studies (Obs) the risks and/or benefits related to DAT vs. triple antithrombotic treatment (TAT) regimens in patients affected by AF undergoing PCI. MATERIALS AND METHODS: RCTs and Obs were retrieved through PubMed database. The risk ratio with 95% confidence interval was used to compare the primary and the safety endpoints. RESULTS: Meta-analysis demonstrated no significant differences between DAT vs. TAT for mortality. However, a two-fold higher mortality rate was registered in Obs than in RCTs. The Obs did not confirm the expected significant reduction in bleeding risk shown by the RCTs; however, the bleeding rates in Obs were more than three-fold those of RCTs. In Obs, a significant greater risk for stent thrombosis was observed in DAT than in TAT. CONCLUSIONS: The safety and efficacy outcomes observed in RCTs are unrealistic with respect to the current clinical practice. So, more evidence is needed to have more exhaustive guidelines based on RCTs with homogeneous designs and protocols that should mimic real-life population and practice.


Assuntos
Fibrilação Atrial , Intervenção Coronária Percutânea , Trombose , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Inibidores da Agregação Plaquetária/uso terapêutico , Fibrinolíticos , Anticoagulantes/uso terapêutico , Trombose/etiologia , Quimioterapia Combinada , Intervenção Coronária Percutânea/efeitos adversos
2.
Eur Rev Med Pharmacol Sci ; 23(18): 8018-8027, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31599427

RESUMO

OBJECTIVE: The aim of the meta-analysis was to assess post-procedural outcome of the new generation of transcatheter aortic valve implantation (TAVI) devices, focusing on the transfemoral and balloon-expandable SAPIEN 3 (Edwards Lifesciences Inc., Irvine, CA, USA), the self-expanding CoreValveTM Evolut series R and PRO (R/PRO)TM (Medtronic Inc., Minneapolis, MN, USA) and ACURATE neoTM transcatheter aortic valve (Symetis SA, a Boston Scientific company, Ecublens, Switzerland). MATERIALS AND METHODS: All observational studies were retrieved through PubMed computerized database from January 2014 until June 30th, 2019. The risk difference (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. The primary end point was 30-day mortality. Safety end points included: (i) stroke, (ii) moderate/severe paravalvular leak, and (iii) the need for new permanent pacemaker implantation. RESULTS: Meta-analysis demonstrated no significant differences as regards to either 30-day mortality or stroke for all the groups of prostheses under comparison. ACURATE neo was associated with significantly less new permanent pacemaker implantation compared to SAPIEN 3 (RD: -0.06; 95% CI -0.08 to -0.03; p<0.0001; I2=0%) or to EVOLUT R/PRO (RD: -0.06; 95% CI -0.09 to -0.02; p=0.0009; I2=0%). A significant reduction of new permanent pacemaker need was observed in the group of patients implanted with SAPIEN 3 compared to EVOLUT R/PRO (RD: -0.07; 95% CI -0.09 to -0.04; p<0.00001; I2=7%). The occurrence of moderate/severe leak was significantly increased in the group of patients implanted with ACURATE neo vs. SAPIEN 3 (RD: 0.04; 95% CI 0.02 to 0.05; p<0.00001; I2=0%). No significant differences were found between ACURATE neo vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.02; p=0.69; I2=0%) and between SAPIEN 3 vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.01; p=0.28; I2=73%). CONCLUSIONS: The results of the meta-analysis show that: (1) ACURATE neo was associated with significantly less new permanent pacemaker implantation than SAPIEN 3 and EVOLUT R/PRO; (2) SAPIEN 3 had significantly lower occurrence of moderate/severe valvular leak than ACURATE neo.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Estimulação Cardíaca Artificial , Humanos , Mortalidade , Falha de Prótese , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
3.
Eur Rev Med Pharmacol Sci ; 23(12): 5402-5412, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31298393

RESUMO

OBJECTIVE: We studied the impact of transcatheter aortic valve implantation (TAVI) compared to the surgical aortic valve replacement (SAVR) on 30-day and one-year mortality from randomized controlled trials (RCTs) in patients with severe aortic stenosis at high or low-intermediate surgical risk. MATERIALS AND METHODS: All RCTs were retrieved through PubMed computerized database and the site https://www.clinicaltrials.gov from January 2010 until March 31st, 2019. The absolute risk reduction (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. We evaluated overall mortality rates at 30-day and one-year follow-up in the comparison between TAVI vs. SAVR. We also evaluated the role played by the site access for TAVI performed through the femoral or subclavian artery (TV-TAVI) vs. SAVR, or transapically (TA-TAVI) vs. SAVR. RESULTS: In the "as-treated population" the overall 30-day mortality was significantly lower in TAVI (p=0.03) with respect to SAVR. However, the analysis for TAVI subgroups showed that 30-day mortality was (1) significantly lower in TV-TAVI vs. SAVR (p=0.006), (2) increased, not significantly, in TA-TAVI vs. SAVR (p=0.62). No significant differences were found between TAVI vs. SAVR at one-year follow-up. CONCLUSIONS: The results of our meta-analysis suggest that TV-TAVI is a powerful tool in the treatment of severe aortic stenosis at high or low-intermediate surgical risk, with a significant lower mortality with respect to SAVR. On the contrary, SAVR seems to provide better results than TA-TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Mortalidade Hospitalar , Humanos , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
4.
Eur Rev Med Pharmacol Sci ; 22(8): 2405-2414, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29762859

RESUMO

OBJECTIVE: Intra-aortic balloon pump (IABP) is the device most commonly investigated in patients with cardiogenic shock (CS) complicating acute myocardial infarction (AMI). Recently meta-analyses on this topic showed opposite results: some complied with the actual guideline recommendations, while others did not, due to the presence of bias. We investigated the reasons for the discrepancy among meta-analyses and strategies employed to avoid the potential source of bias. MATERIALS AND METHODS: Scientific databases were searched for meta-analyses of IABP support in AMI complicated by CS. The presence of clinical diversity, methodological diversity and statistical heterogeneity were analyzed. When we found clinical or methodological diversity, we reanalyzed the data by comparing the patients selected for homogeneous groups. When the fixed effect model was employed despite the presence of statistical heterogeneity, the meta-analysis was repeated adopting the random effect model, with the same estimator used in the original meta-analysis. RESULTS: Twelve meta-analysis were selected. Six meta-analyses of randomized controlled trials (RCTs) were inconclusive because underpowered to detect the IABP effect. Five included RCTs and observational studies (Obs) and one only Obs. Some meta-analyses on RCTs and Obs had biased results due to presence of clinical and/or methodological diversity. The reanalysis of data reallocated for homogeneous groups was no more in contrast with guidelines recommendations. CONCLUSIONS: Meta-analyses performed without controlling for clinical and/or methodological diversity, represent a confounding message against a good clinical practice. The reanalysis of data demonstrates the validity of the current guidelines recommendations in addressing clinical decision making in providing IABP support in AMI complicated by CS.


Assuntos
Balão Intra-Aórtico , Infarto do Miocárdio/patologia , Choque Cardiogênico/terapia , Doença Aguda , Humanos , Balão Intra-Aórtico/efeitos adversos , Infarto do Miocárdio/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Choque Cardiogênico/patologia , Resultado do Tratamento
5.
Crit Care Med ; 28(6): 1841-6, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10890630

RESUMO

OBJECTIVE: In patients undergoing surgical repair of aortic dissection, false lumen perfusion during cardiopulmonary bypass may produce central nervous system damage, myocardial ischemia, aortic rupture, and death. We describe a method to detect false lumen perfusion at the beginning of retrograde aortic perfusion that may prevent these complications. DESIGN: Sonicated albumin microbubbles (8 mL) were injected through a side branch of the extracorporeal circulation line to detect true lumen and/or false lumen perfusion of the thoracic aorta at the beginning of cardiopulmonary bypass. Transesophageal echocardiography was used to image aortic perfusion. SETTING: The study was performed in a cardiac surgery theater. PATIENTS: A total of 27 consecutive patients undergoing operation for Type I aortic dissection were studied. INTERVENTIONS: All patients underwent surgical repair of aortic dissection and retrograde aortic perfusion through one femoral artery. MEASUREMENTS AND MAIN RESULTS: Patients were divided into three groups: Group I, those having adequate true lumen perfusion: brisk appearance and washout of contrast in the true lumen with no, poor, or delayed opacification of the false lumen; Group II, those having mixed true lumen and false lumen perfusion: simultaneous opacification of both lumens; Group III, those having inappropriate false lumen perfusion: same criteria as for adequate true lumen perfusion applied to the false lumen. The true lumen was perfused in 13 patients, both lumens in 11 patients, and false lumen alone in three patients. In these three patients, cannulation was repeated through the contralateral femoral artery with restoration of true lumen perfusion; the first patient died of diffuse cerebral ischemic damage and renal failure, another one experienced temporary postoperative monoparesis, and the last had no neurologic sequelae. CONCLUSIONS: Contrast echocardiography allows immediate detection of retrograde aortic perfusion during cardiopulmonary bypass and may help prevent neurologic complications and death in patients with Type I dissection.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ponte Cardiopulmonar , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
8.
J Am Coll Cardiol ; 34(2): 428-34, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10440155

RESUMO

OBJECTIVES: This study evaluates whether a quantitative measurement of Doppler intensity during handgrip may disclose coronary vasomotor dysfunction in patients with coronary artery disease (CAD). BACKGROUND: Atherosclerotic coronary segments show an exaggerated constrictive response to handgrip. The intensity of the scattered Doppler signal is proportional to the number of blood cells flowing through the vessel, and should be reduced during vasoconstriction. Therefore, changes in coronary flow during handgrip may be detected by measuring Doppler intensity rather than velocities. METHODS: The distal left anterior descending coronary artery (LAD) was imaged by high-resolution transthoracic color Doppler echocardiography during handgrip in 47 patients: 15 with normal coronary arteries and 32 with significant CAD involving the LAD. The Doppler signal was acquired at 70 dB dynamic range at baseline, 30-s handgrip and 5 min recovery. Peak and mean flow velocity, pressure half-time, deceleration time (ms), deceleration rate (cm/s2) and mean gray level intensity (intensity units [IU]) of the Doppler spectrum were measured in diastole. RESULTS The velocity parameters did not change significantly during handgrip both in normal and CAD patients. The Doppler intensity significantly decreased during handgrip (from 87.0 +/- 32.8 to 57.7 +/- 35.3 IU; p < 0.001) in patients with CAD, and it increased or remained unchanged in normals (from 74.1 +/- 27.3 to 85.1 +/- 31.2 IU; p = NS). The sensitivity of Doppler intensity in detecting CAD was 84.4%, specificity 93.3%, negative predictive value 73.7% and positive predictive value 96.4%. CONCLUSIONS: Doppler intensity measured by transthoracic echocardiography during handgrip allows the detection of CAD and coronary vasomotor dysfunction.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Ecocardiografia Doppler em Cores , Força da Mão , Vasoconstrição , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Sensibilidade e Especificidade
10.
J Thorac Cardiovasc Surg ; 113(3): 585-93, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9081106

RESUMO

OBJECTIVE: We evaluated, in the prevention of perioperative unintentional myocardial ischemia, the role of coronary collateral flow in patients with left anterior descending coronary artery stenosis or occlusion who underwent elective coronary artery bypass grafting. METHODS: Coronary lesions and collaterals were assessed by coronary angiography in 21 patients. Anteroseptal myocardial viability was evaluated by dobutamine echocardiography. Antegrade perfusion of cardioplegic solution was assessed by myocardial contrast echocardiography. Time-intensity curves were generated from the anteroseptal region. Twelve parameters were measured and averaged in the following four groups of patients: those with stenosis of the left anterior descending artery and poor collaterals; those with stenosis of the left anterior descending artery and good collaterals; those with occlusion of the left anterior descending artery and good collaterals; and those with occlusion of the left anterior descending artery and poor collaterals. RESULTS: Time-intensity curves were significantly different in patients with stenosis versus occlusion of the left anterior descending artery (p < 0.005); multiple comparisons with Bonferroni's correction showed that this difference was mainly a result of the impact of collateral circulation (p < 0.01). However, the role of collaterals was nonsignificant within the groups with stenosis and occlusion of the left anterior descending artery. Patients with occlusion of the left anterior descending artery and good collaterals had perfusion parameters similar to those of patients with stenosis of the left anterior descending artery (p = not significant), except for the ascending slope and time to peak values (p < 0.05 and p < 0.01, respectively), which reflected a higher flow resistance in the collateral circulation. Regional systolic function after coronary artery bypass grafting was depressed in patients with poor collaterals and poor perfusion of cardioplegic solution, as compared with findings in other subgroups. CONCLUSIONS: Incomplete myocardial protection may impair the early recovery of function after coronary artery bypass grafting.


Assuntos
Circulação Colateral , Ponte de Artéria Coronária , Circulação Coronária , Doença das Coronárias/cirurgia , Parada Cardíaca Induzida , Isquemia Miocárdica/prevenção & controle , Sobrevivência Celular , Constrição Patológica , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Ecocardiografia , Feminino , Parada Cardíaca Induzida/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/fisiopatologia
11.
Eur J Cardiothorac Surg ; 10(10): 890-6, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8911844

RESUMO

OBJECTIVES: The present report is a critical review on primary repair of aortic coarctation by patch aortoplasty on the basis of over 30 years surgical experience. METHODS: Since 1962, 60 patients (mean age 9.4 +/- 4.8 years, range 2-25 years), affected by aortic coarctation, underwent patch aortoplasty repair. During the operation protective guidelines were adopted: additional external Dacron was placed around the repaired site in cases of friable host tissue, the aortic ridge was not excised to leave the posterior aortic wall intact, and the patent ductus arteriosus or ligamentum arteriosum was transected and sutured. Prophylactic measures of neurologic sequelae were: dual pressure monitoring, sequential aortic clamping, surgical shunt or left heart bypass associated with moderate hypothermia when the distal aortic pressure was less than 50 mmHg. RESULTS: No early deaths occurred. The overall survival rate was 92.77 +/- 4.04% at 31 years from surgery. Three late deaths occurred. Pressure gradients across the patch ranged between 9 and 20 mmHg. Late aneurysm occurred in one patient (1.3%), 2 years after bacterial endocarditis had developed on a biscuspid aortic valve. CONCLUSIONS: Patch aortoplasty is an effective and safe surgical procedure for primary repair of isthmic aortic coarctation when other surgical techniques cannot be performed.


Assuntos
Coartação Aórtica/cirurgia , Prótese Vascular , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Aorta Torácica/cirurgia , Coartação Aórtica/mortalidade , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Recidiva , Fatores de Risco , Taxa de Sobrevida
12.
Am Heart J ; 129(3): 521-6, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7872183

RESUMO

Dobutamine echocardiography has recently been introduced for use in identification of viable myocardium in patients with acute myocardial infarction and prediction of the response of dysfunctioning myocardial segments to coronary angioplasty. The aim of this study was to evaluate whether this test may be used to predict the early response of dysfunctioning myocardial segments to surgical revascularization. We studied 30 patients with three-vessel disease and chronic, stable angina pectoris during coronary artery bypass grafting (CABG). Patients were monitored by intraoperative transesophageal echocardiography in the transgastric short-axis view at the papillary muscle level. The left ventricle was divided into eight segments; and 240 myocardial segments were analyzed. Percentage of systolic wall thickening (PSWT) was calculated in each segment at baseline (early after pericardiectomy), before bypass during dobutamine infusion (5 micrograms/kg/min), and after separation from cardiopulmonary bypass. Segments showing PSWT < 30% at baseline were considered dysfunctional. Segments showing an increase in PSWT > 10% during dobutamine infusion were considered responders. Segments showing an increase in PSWT < 10% during dobutamine infusion were considered nonresponders. At baseline, 161 (67%) of 240 segments had PSWT < 30% (dysfunctioning segments). During dobutamine, 98 (60%) of these segments increased PSWT > 10% (from 11.3% +/- 7.6% to 24.2% +/- 12.0%, p < 0.01; responder segments), and 63 (40%) increased PSWT < 10% (from 10.2% +/- 4.9% to 8.3% +/- 5.5%, p value not significant [NS]; nonresponder segments).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardiomiopatias/diagnóstico por imagem , Ponte de Artéria Coronária , Dobutamina , Ecocardiografia Transesofagiana , Adulto , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Sensibilidade e Especificidade
13.
Circulation ; 91(6): 1714-8, 1995 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-7882478

RESUMO

BACKGROUND: The pathogenesis of posterior papillary muscle dysfunction is poorly understood. We hypothesized that papillary muscle perfusion pattern may explain the higher prevalence of posterior papillary muscle dysfunction after myocardial infarction. METHODS AND RESULTS: Twenty patients were monitored by transesophageal echocardiography during coronary surgery. Superselective coronary graft injections of 0.2 to 0.5 mL of sonicated albumin microbubbles were performed to assess graft patency and papillary muscle perfusion. Thirty-five graft injections were analyzed: 13 in the right coronary artery, 15 in an obtuse marginal branch, 1 in the left anterior descending coronary artery, and 6 in the first diagonal branch. The posterior papillary muscle was opacified in 16 patients, 11 from the right coronary artery and 5 from one obtuse marginal branch. In 10 of 16 patients (63%), the papillary muscle was perfused by one vessel, while in 6 of 16 (37%), it was perfused by two vessels. The anterior papillary muscle was opacified in 14 patients. Ten patients (71%) had double-vessel and 4 (29%) had single-vessel supply. In the subgroup of 10 patients with old inferior myocardial infarction, mitral regurgitation was present only among those 6 with single rather than double blood supply (P < .05). CONCLUSIONS: Myocardial infarction may cause papillary muscle dysfunction when the blood supply is provided by one rather than two vessels, as is more frequently the case with the posterior rather than the anterior papillary muscle.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Infarto do Miocárdio/complicações , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/fisiopatologia , Adulto , Idoso , Ponte de Artéria Coronária/efeitos adversos , Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Ecocardiografia Transesofagiana , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Infarto do Miocárdio/diagnóstico por imagem
15.
Anesthesiology ; 79(5): 904-12, 1993 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8239008

RESUMO

BACKGROUND: Cardioplegia is used to protect the myocardium from ischemic injury during open-heart surgery. However, the delivery of cardioplegic solutions may be impaired by anatomic and/or functional conditions, such as the development of transient aortic regurgitation during antegrade administration of cardioplegia or shunting through a foramen ovale during retrograde administration. In this study, the authors used a new method of cardioplegia administration, based on intraoperative contrast echocardiography, to detect on-line causes of inadequate cardioplegia delivery. METHODS: Forty patients with coronary artery disease and a competent aortic valve, who were treated consecutively, were enrolled in this study. Patients were monitored intraoperatively by transesophageal contrast echocardiography during cardioplegia delivery. Antegrade cardioplegia was administered into the aortic root following aortic occlusion in all patients. Twenty-two patients also received retrograde cardioplegia, administered through the right atrium. The echo-contrast agent consisted of a stable suspension of 5% human albumin microbubbles with a concentration of 4 x 10(8) microbubbles/ml and a diameter of 4 +/- 1 mu. RESULTS: Antegrade cardioplegia was not associated with aortic regurgitation in 23 of 40 (58%) patients. Seven patients (17%) had only mild aortic regurgitation, four patients (10%) had moderate regurgitation, and six (15%) had severe aortic regurgitation. The percent of myocardial opacification was 76.0 +/- 10.5 in the 23 patients who did not have aortic regurgitation, 76.0 +/- 17.0 in the 7 patients who had mild regurgitation, 52.5 +/- 18.1 in the 4 patients who had moderate regurgitation, and 48.5 +/- 18.3 in 6 patients who had severe aortic regurgitation (Kruskal-Wallis stat, 12.9; P < 0.005). Retrograde cardioplegia was not associated with right-to-left shunt in 11 of 22 patients (50%). In seven patients (32%), there was only a mild passage of contrast material to the left atrium. In the remaining four patients (18%), there was a moderate (one patient) to severe (three patients) right-to-left shunt at the level of the fossa ovalis. CONCLUSIONS: This study shows that incomplete myocardial distribution of cardioplegia, secondary to transient aortic valve incompetence or shunting through the foramen ovale, is not uncommon in patients undergoing coronary surgery.


Assuntos
Soluções Cardioplégicas/administração & dosagem , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Ecocardiografia Transesofagiana , Monitorização Intraoperatória , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Cardiologia ; 38(7): 431-5, 1993 Jul.
Artigo em Italiano | MEDLINE | ID: mdl-8221737

RESUMO

The aim of this study was to assess the distribution of antegrade and retrograde cardioplegia with intraoperative contrast echocardiography in patients undergoing coronary artery bypass grafting. Fifteen patients with chronic stable angina pectoris and severe coronary artery disease were studied. The severity of coronary artery disease was assessed at coronary angiography, using the Jeopardy Score System. The presence and the extent of collateral circulation was evaluated on the basis of preoperative coronary angiography and graded as: absent or poor; good or excellent. Coronary revascularization was carried out during extracorporeal circulation and myocardial protection was performed with antegrade (aortic root) and retrograde (right atrial) cardioplegia. The echo contrast agent was sterilely prepared 1 hour prior to surgery and consisted of a solution of sonicated 5% human albumin microbubbles. Two ml of sonicated albumin were injected along with antegrade cardioplegia and 4 ml with retrograde cardioplegia. The echocardiographic images were obtained with transesophageal echocardiography in the transgastric left ventricular short-axis view. Images were recorded on videotape for off-line planimetric measurement of percent myocardial opacification. Data were analyzed with the analysis of variance. Multiple comparisons were made with Student's paired t test and using Bonferroni's correction. Myocardial opacification was 58.9 +/- 12.9% during antegrade cardioplegia and 77.5 +/- 16.4% during retrograde cardioplegia (p = 0.003). This overall difference was mainly due to the impact of collateral circulation in the distribution of antegrade cardioplegia. Patients with absent or poor collateral circulation showed a lower degree of myocardial opacification than patients with good or excellent myocardial opacification (44.3 +/- 12.0% versus 64.2 +/- 8.6%; p < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Ecocardiografia Doppler/métodos , Parada Cardíaca Induzida/métodos , Cuidados Intraoperatórios/métodos , Revascularização Miocárdica/métodos , Análise de Variância , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/epidemiologia , Doença das Coronárias/cirurgia , Ecocardiografia Doppler/estatística & dados numéricos , Feminino , Parada Cardíaca Induzida/estatística & dados numéricos , Humanos , Cuidados Intraoperatórios/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica/estatística & dados numéricos , Albumina Sérica
17.
Cardiologia ; 38(3): 173-8, 1993 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-8339306

RESUMO

The aim of this study was to detect by dopamine echocardiography dysfunctioning but viable myocardial segments. We have studied 19 patients with 3-vessel disease and chronic, stable angina pectoris. Patients were studied by intraoperative transesophageal echocardiography during coronary artery bypass surgery. The analysis of regional systolic function was performed utilizing the transgastric short-axis view at papillary muscle level and dividing the left ventricle in 8 segments, according to the recommendations of the American Society of Echocardiography. A total of 152 myocardial segments were analyzed. Percent systolic wall thickening was calculated in each segment at baseline (early after pericardiectomy), during dopamine infusion (5 mcg/kg/min) and 30 min after separation from cardiopulmonary bypass (after protamine administration). The administration of vasodilatory or inotropic drugs was avoided. The echocardiographic images were recorded on videotape and analyzed off-line by 2 independent observers. Segments showing at baseline percent systolic wall thickening < 30% were considered dysfunctional (134/152 = 88%). Eighty-four (63%) of these segments, increasing during dopamine infusion percent systolic wall thickening > 10% (from 12.9 +/- 3.5 to 20.7 +/- 5.4%; p < 0.05) were considered responder. On the other hand, 50 segments (37%) showing during dopamine an increment in percent systolic wall thickening < 10%, were considered non-responder. After coronary surgery, responder segments showed a significant increase in percent systolic wall thickening in comparison with baseline values (from 12.9 +/- 3.5 to 22.1 +/- 4.3%; p < 0.05). Segments non-responding to dopamine showed no significant changes in percent systolic wall thickening after myocardial revascularization.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Dopamina , Ecocardiografia/métodos , Coração/efeitos dos fármacos , Cuidados Intraoperatórios/métodos , Angina Pectoris/diagnóstico , Angina Pectoris/fisiopatologia , Angina Pectoris/cirurgia , Doença das Coronárias/diagnóstico , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Ecocardiografia/estatística & dados numéricos , Esôfago , Feminino , Coração/fisiopatologia , Humanos , Cuidados Intraoperatórios/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Estimulação Química
18.
Eur J Cardiothorac Surg ; 7(11): 612-4, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8297616

RESUMO

We report two cases of acquired coronary fistula in whom fistula flow and surgical repair were evaluated intraoperatively by contrast echocardiography. Surgical repair was carried out through the left atrium because of the associated surgical procedure on the mitral valve. Contrast echocardiography allowed easy identification of the fistula openings in the left atrium and intraoperative control of the efficacy of the surgical closure. Contrast echocardiography is an ideal tool for the intraoperative diagnosis of effective interruption of a coronary fistula.


Assuntos
Fístula Artério-Arterial/diagnóstico por imagem , Fístula Artério-Arterial/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ecocardiografia Transesofagiana , Feminino , Átrios do Coração , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade
19.
Anesth Analg ; 75(2): 213-8, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1632535

RESUMO

Echocardiography has revealed evidence of "subnormal" regional contraction patterns that result from myocardial ischemia and are often accompanied by nonadjacent "hyperkinetic" regions. Whether these regions of hyperkinetic wall motion persist unchanged or revert to normal after coronary artery bypass graft (CABG) surgery has not been studied in humans. Using echocardiography, we evaluated both dysfunctional and normal myocardial regions for changes in segmental wall motion and percent of systolic wall thickening that occurred immediately after CABG surgery in 32 patients. Segmental wall motion analysis before CABG surgery in these patients revealed that 170 (66%) of 256 myocardial segments were subnormal, of which 115 (67%) improved and 102 (60%) returned to normal immediately after CABG surgery. Eleven myocardial segments that were hyperkinetic before CABG surgery returned to normal after CABG surgery. Preoperatively, 162 (63%) of 256 myocardial segments had systolic wall thickening less than 30%, which increased from 11.8% +/- 8.9% to 24.3% +/- 14.3% (mean +/- SD) (P less than 0.01) postoperatively. Conversely, a reverse trend was found when systolic wall thickening was greater than 30% before CABG surgery: thickening decreased from 46.2% +/- 13.8% to 33.4% +/- 14.8% after CABG surgery (P less than 0.01). Thus, we conclude that immediately after CABG surgery, there is a recovery of function in some myocardial segments and a reduction in function in others. Furthermore, we conclude that the semiquantitative assessment of percent of systolic wall thickening is a more reliable (consistent) echocardiographic index of myocardial function compared with the qualitative assessment of segmental wall motion immediately after CABG surgery.


Assuntos
Ponte de Artéria Coronária , Ecocardiografia , Contração Miocárdica/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Cardiologia ; 37(2): 105-11, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1600528

RESUMO

This study evaluated the early effect of coronary artery bypass grafting (CABG) on left ventricular systolic function. Intraoperative echocardiography was performed in 32 patients with coronary artery disease and chronic, stable angina pectoris. Left ventricular short-axis images at mid-papillary muscle level were videotaped at similar loading conditions shortly after pericardiotomy and 28 +/- 5 min after weaning from cardiopulmonary bypass. Inotropic or vasodilator administration was avoided or suspended at least 5 min before echocardiography. The left ventricle was divided off-line into 8 segments. The ejection fraction and percent systolic wall thickening (PSWT) were calculated pre- and post-CABG. A total of 256 myocardial segments were analyzed. Any segment showing a preoperative PSWT of less than 30% was considered dysfunctional, while segments with a PSWT of greater than 30% were considered normal. After surgery, the PSWT in 162 dysfunctional segments (63%) increased from 11.8 +/- 8.9 to 24.3 +/- 14.3% (p less than 0.001). Conversely, a reverse trend was found in the remaining 94 normal segments (37%) with a decreasing PSWT from 46.2 +/- 13.8 to 33.4 +/- 14.8% (p less than 0.001). Ejection fraction also increased from 47.2 +/- 3.5 to 58.5 +/- 18.9% (p less than 0.05). Thus, CABG is followed by an immediate recovery of systolic function in dysfunctional myocardial segments, while compensatory hyperfunction is reduced in normal segments. These results indicate that the post-CABG improvement in PSWT is due to redistribution of coronary blood flow, rather than to pharmacological or hormonal influences. Intraoperative echocardiography is a useful technique to monitor left ventricular function during surgery.


Assuntos
Ponte de Artéria Coronária , Coração/fisiologia , Adulto , Idoso , Circulação Coronária , Ecocardiografia , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Volume Sistólico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...