Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Chemosphere ; 294: 133693, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35063561

RESUMO

Water-soluble ions were analysed in size segregated aerosol samples collected in the port of Alicante (Southeastern Spain) during summer and winter using a multistage cascade impactor. Seasonal variations in the size distributions of the analysed components and the influence of bulk materials handling (loading/unloading and stockpiling) at the docks were investigated. The size distributions of SO42-, NH4+ and K+ were characterized by prominent peaks in the condensation and droplet modes, both in summer and winter, while those of Ca2+, Na+, Mg2+ and Cl- had a main peak centred at ∼4 µm. Although oxalate size distributions were similar during both seasons, the fraction of coarse-mode oxalate increased in summer most likely as a result of volatilization and repartition processes or reactions of oxalic acid with coarse alkaline particles. Nitrate size distributions were dominated by a coarse mode; however, during winter, modal peaks in the submicron size range were also observed due to favourable conditions for the formation of fine-mode NH4NO3. Harbour activities had a significant impact only on the concentrations of calcium, particularly in the coarse fraction, during both summer and winter.


Assuntos
Poluentes Atmosféricos , Material Particulado , Aerossóis/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental , Nitratos/análise , Tamanho da Partícula , Material Particulado/análise , Estações do Ano , Solubilidade
2.
J Environ Manage ; 281: 111842, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33370677

RESUMO

The main objective of this work was to quantify the impact of handling of bulk materials on PM10 levels measured at the port-city border of Alicante (Spain), located on the western Mediterranean coast. To achieve that goal, 355 PM10 samples were collected at the perimeter of the harbor of Alicante from March 2017 to February 2018. A 181 sample subgroup was chemically characterized in order to perform a source apportionment study with the EPA PMF 5.0 model. Eight factors were identified, two of them directly related to the handling of bulk materials (Limestone + gypsum and Clinker), accounting jointly for 35% of the average PM10 concentration. A Road traffic factor was the second highest contributor to PM10 levels (17%) while the Shipping emissions factor accounted for only 6% of the average PM10 mass. Other factors such as Biomass burning+ secondary nitrate and Aged sea salt represented a joint contribution of 25% of the PM10 mass. Results indicate that emission abatement strategies should primarily focus on the reduction of fugitive emissions caused by the handling of bulk materials at the docks. Moreover, scenarios including reductions of more than 50% in bulk handling sources and 10% in other anthropogenic sources would help to reduce anthropogenic exceedances of the daily PM10 limit (50 µg·m-3) and to approach to WHO daily PM10 standard (20 µg m-3).


Assuntos
Poluentes Atmosféricos , Material Particulado , Poluentes Atmosféricos/análise , Cidades , Monitoramento Ambiental , Material Particulado/análise , Espanha
4.
Chemosphere ; 167: 382-395, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27744196

RESUMO

The occurrence and seasonal distribution of polycyclic aromatic hydrocarbons (PAHs) and legacy and current-use pesticides (CUPs) in air were characterized around the Mar Menor lagoon using both active and passive sampling devices. The seasonal distribution of these pollutants was determined at 6 points using passive samplers. Passive sampler sampling rates were estimated for all detected analytes using an active sampler, considering preferentially winter data, due to probable losses in active sampling during summer (high temperatures and solar irradiation). The presence of 28 compounds (14 CUPs, 11 PAHs and 3 organochlorinated pesticides) were detected in air by polyurethane passive sampling. The most commonly detected contaminants (>95% of samples) in air were chlorpyrifos, chlorpyrifos-methyl and phenanthrene. The maximum concentrations corresponded to phenanthrene (6000 pg m-3) and chlorpyrifos (4900 pg m-3). The distribution of contaminants was spatially and seasonally heterogeneous. The highest concentrations of PAHs were found close to the airport, while the highest concentrations of pesticides were found in the influence area of agricultural fields (western stations). PAH and herbicide concentrations were higher in winter than in the other seasons, although some insecticides such as chlorpyrifos were more abundant in autumn. The presence of PAHs and legacy and current-use pesticides in air confirmed their transference potential to marine coastal areas such as the Mar Menor lagoon.


Assuntos
Poluentes Atmosféricos/análise , Praguicidas/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Clorpirifos/análogos & derivados , Clorpirifos/análise , Monitoramento Ambiental/instrumentação , Mar Mediterrâneo , Fenantrenos/análise , Estações do Ano , Espanha
5.
Waste Manag ; 34(11): 2393-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25106121

RESUMO

Gaseous emissions are an important problem in municipal solid waste (MSW) treatment plants. The sources points of emissions considered in the present work are: fresh compost, mature compost, landfill leaks and leachate ponds. Hydrogen sulphide, ammonia and volatile organic compounds (VOCs) were analysed in the emissions from these sources. Hydrogen sulphide and ammonia were important contributors to the total emission volume. Landfill leaks are significant source points of emissions of H2S; the average concentration of H2S in biogas from the landfill leaks is around 1700 ppmv. The fresh composting site was also an important contributor of H2S to the total emission volume; its concentration varied between 3.2 and 1.7 ppmv and a decrease with time was observed. The mature composting site showed a reduction of H2S concentration (<0.1 ppmv). Leachate pond showed a low concentration of H2S (in order of ppbv). Regarding NH3, composting sites and landfill leaks are notable source points of emissions (composting sites varied around 30-600 ppmv; biogas from landfill leaks varied from 160 to 640 ppmv). Regarding VOCs, the main compounds were: limonene, p-cymene, pinene, cyclohexane, reaching concentrations around 0.2-4.3 ppmv. H2S/NH3, limonene/p-cymene, limonene/cyclohexane ratios can be useful for analysing and identifying the emission sources.


Assuntos
Poluentes Atmosféricos/análise , Biocombustíveis/análise , Resíduos Sólidos/análise , Poluentes Químicos da Água/análise , Amônia/análise , Sulfeto de Hidrogênio/análise , Compostos Orgânicos Voláteis/análise
6.
Sci Total Environ ; 466-467: 439-46, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23933449

RESUMO

In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25-1 µm) at the mountain site, 55.0 ± 3.0 cm(-3), was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm(-3)). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5-2 µm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1cm(-3) at the urban site and 0.9 ± 0.1cm(-3) at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of >4.0 cm(-3), than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O3 levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3-17%) with respect to its mean value.

7.
Int J Clin Pract ; 67(1): 81-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23241052

RESUMO

BACKGROUND: Low-density lipoprotein cholesterol (LDL-C) remains the primary target of therapy in most strategies of dyslipidaemia management focused on cardiovascular disease prevention. Different guidelines have identified specific LDL-C cut-off points as targets for therapeutic intervention. Many clinical situations characterised by dyslipidaemia and elevated triglycerides are common in our environment and in overall industrialised countries. Thus, lipid goals based only on LDL-C could misclassify an important percentage of subjects. The objective of the present study was to establish cut-off point values for apoB and non-HDL-C in relation to the identified LDL-C cut-off points for cardiovascular risk in a South European population. METHODS: We performed a cross-sectional study including 1501 subjects (770 women and 731 men) between 18 and 80 years of age. Samples were collected after 12-14 h of fasting. Cholesterol, HDL-C, triglycerides and apoB levels were measured using direct methods. LDL-C was calculated by the Friedewald formula. Non-HDL-C was calculated as total cholesterol minus HDL-C. RESULTS: The Spearman's rank correlations between apoB and LDL-C (r 0.86, p < 0.0001), and between apoB and non-HDL-C (r 0.91, p < 0.0001) were both significant. The proposed cut-off points for apoB, according to LDL-C goals (70, 100, 130 and 160 mg/dl) in our population are 70, 80, 100 and 115 mg/dl respectively. The proposed cut-off values for non-HDL-C are 100, 120, 150 and 190 mg/dl respectively. CONCLUSION: The established LDL-C cut-off values could not be accurate to estimate cardiovascular risk in subjects with mild hypertriglyceridaemia, as frequently occurs in our Mediterranean population. To take into consideration the burden of atherogenic particles and better classify patients at risk we propose cut-off values for apoB or the equivalent for non-HDL-C. Prospective trials including cardiovascular variables are needed to validate our assumption.


Assuntos
Apolipoproteínas B/sangue , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/etnologia , Estudos Transversais , Feminino , Humanos , Hipertrigliceridemia/sangue , Hipertrigliceridemia/etnologia , Masculino , Pessoa de Meia-Idade , Valores de Referência , Espanha/etnologia , Triglicerídeos/sangue , Adulto Jovem
8.
Water Sci Technol ; 66(12): 2517-23, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23109565

RESUMO

This study involved collaboration between three centres with expertise in viruses, bacteria and protozoa. The focus of the research was the study of the dissemination and removal of pathogens and faecal indicators in two sewage treatment plants (STP1 and STP2) using tertiary treatments. Samples were collected over a period of five months through the sewage treatment processes. Analysis of the samples revealed that the plants were not efficient at removing the faecal indicators and pathogens tested during the study. From entry point (raw sewage) to effluent level (tertiary treatment effluent water), the experimental results showed that the reduction ratios of human adenoviruses were 1.2 log10 in STP1 and 1.9 log10 in STP2. Whereas for Giardia spp. and Cryptosporidium spp. the reduction ratios were 2.3 log10 for both pathogens in STP1, and 3.0 and 1.7 log10 in STP2, respectively. Furthermore, the presence of faecal indicators and pathogens at different sampling points was evaluated revealing that the tested pathogens were present in reclaimed water. Human adenovirus and Arcobacter spp. showed positive results in infectivity assays for most of the tertiary effluent water samples that comply with current legislation in Spain. The pathogens detected must be evaluated using a risk assessment model, which will be essential for the development of improved guidelines for the re-use of reclaimed water.


Assuntos
Fezes/microbiologia , Esgotos/microbiologia , Microbiologia da Água/normas , Purificação da Água/métodos , Purificação da Água/normas , Adenoviridae/isolamento & purificação , Bactérias/isolamento & purificação , Cryptosporidium/isolamento & purificação , Fezes/parasitologia , Fezes/virologia , Giardia/isolamento & purificação , Humanos , Padrões de Referência , Esgotos/parasitologia , Esgotos/virologia
9.
Rev Calid Asist ; 26(4): 264-8, 2011.
Artigo em Espanhol | MEDLINE | ID: mdl-21621440

RESUMO

PURPOSE: To show the number of preanalytical sample errors in seven laboratories attending seven health departments of Valencian Community (Spain). METHODS: Cross-sectional study of the number of preanlytical errors in samples obtained in primary care centers. An error is defined as a rejected specimen: any blood or urine sample, which cannot be successfully tested as it does not meet the acceptability criteria of the laboratory or if the sample is not received. We collected preanalytical errors from the tests requested for hematology, coagulation, chemistry, and urine samples. Registers were collected and indicators calculated automatically through a data warehouse and OLAP cubes software. RESULTS: Large differences in the results of preanalytical errors were observed between health departments. The highest percentage of errors occurred in coagulation samples, followed by urine, hematology and biochemistry. With regard to the type of error, the largest proportion of errors was due to failures of process. CONCLUSIONS: The high incidence of preanalytical errors and variability between health departments suggests that there is a need to standardize the drawing practice.


Assuntos
Técnicas de Laboratório Clínico/normas , Estudos Transversais , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade
10.
Rev Calid Asist ; 26(2): 104-10, 2011.
Artigo em Espanhol | MEDLINE | ID: mdl-21256066

RESUMO

PURPOSE: To show turnaround time to client source in eight laboratories covering eight Health Areas (2,014,475 inhabitants) of the Valencian Community (Spain). MATERIAL AND METHODS: Internal Laboratory Information System (LIS) registers (test register and verification date and time), and daily LIS registers were used to design the indicators, These indicators showed the percentage of key tests requested (full blood count and serum glucose and thyrotropin) that were validated on the same day the blood was taken (inpatients and Primary Care and/or at 12 a.m. (inpatients). Urgent (stat) tests were also registered as key tests (serum troponin and potassium) and were recorded in minutes. Registers were collected and indicators calculated automatically through a Data Warehouse application and OLAP cube software. RESULTS: Long turnaround time differences were observed at 12 a.m. in inpatients, and in the day of sample extraction in primary care patients. The variability in turnaround of stat tests is related to hospital size, activity and validation by the laboratory physician. CONCLUSIONS: The study results show the large turnaround time disparity in eight Health Care Areas of Valencian Community. The various requesting sources covered by the laboratories create the need for continuous mapping processes redesign and benchmarking studies to achieve customer satisfaction.


Assuntos
Testes Diagnósticos de Rotina/estatística & dados numéricos , Eficiência Organizacional/estatística & dados numéricos , Laboratórios Hospitalares/estatística & dados numéricos , Benchmarking , Emergências , Número de Leitos em Hospital , Departamentos Hospitalares , Registros Hospitalares , Sistemas Computadorizados de Registros Médicos , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Espanha , Fatores de Tempo
11.
Sci Total Environ ; 408(21): 4999-5009, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20705329

RESUMO

The results of this study show the high impact that anthropogenic fugitive emissions of mineral dust have on air quality (levels of PM(10), PM(2.5) and some metals) in a region in SE Spain named L'Alacantí. This could be extensive to other areas of Europe with similar characteristics. Fugitive emissions, such as those arising from large public construction works, cement and ceramic manufacturing, mining, heavy industries, handling and transport of powdered raw materials and road dust, are very often left out of emission monitoring and inspections in Europe. The comparative study of daily PM(10) series in the area shows how the increase of annual average PM(10) concentrations over 40 microg/m(3) is due to extreme episodes occurring in 2006 and 2007, at a regional scale, given the simultaneous recording of PM episodes at distant monitoring sites. The annual average values of the PM(10) concentrations were close to or slightly higher than 40 microg/m(3) (limit value of Directive 2008/50/CE) during 2006-2007 (Alicante-University 39-41, Agost 40-42, Sant Vicent 42-46, Alicante-El Plà 40-42 microg/m(3)). The main PM(10) sources in the zone were identified with the assistance of the PMF receptor model. Six common factors were determined, mineral as a main source (37% at Agost and 32% at Sant Vicent), road traffic, secondary sulfate, petroleum coke, sea spray and industry. Mineralogical studies, with XRD and SEM-EDX techniques, support the hypothesis that the highest PM episodes are associated to fugitive emissions of mineral matter. Despite the fact that L'Alacantí region is a heavily industrialized area with two cement plants and a significant number of ceramic manufacturing plants, the fugitive emissions may have accounted for the exceedances of the PM limit values during these two years, part of them caused by the construction of a highway. These results may contribute to the interpretation of prior studies on source apportionment carried out in Southern Europe, with very high loads of anthropogenic dust in PM(10) and PM(2.5).


Assuntos
Poluentes Atmosféricos/análise , Atmosfera/química , Monitoramento Ambiental , Material Particulado/análise , Poluição do Ar/estatística & dados numéricos , Tamanho da Partícula , Espanha , Oligoelementos/análise
12.
Environ Pollut ; 118(2): 259-72, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11939288

RESUMO

Bulk deposition composition and pine branch washing were measured from April 1999 to March 2000 on the east coast of Spain. The main objective was to characterise N deposition patterns with special emphasis on dry deposition. Bulk deposition in the region is dominated by neutralisation processes by Ca2+ and HCO3-, ClNa of marine origin and a high correlation between NO3- and SO4(2-). SO4(2-) concentrations show a decrease with respect to previous studies in the region in agreement with generalized sulfur emission decreases while the remaining ions, including NO3-, are higher due to their general increase as well as to the inclusion of dry deposition in bulk collectors in the present study. An enrichment in NO3- has been observed in dry deposition composition branch washing) with respect to bulk deposition, while an impoverishment has been observed in the case of NH4+. Annual bulk deposition varies between 7.22-3.1 and 3.5-1.8 Kg ha(-1) year(-1) for S- SO4(2-) and N- NO3-, respectively. N total deposition goes from 9.78 to 6.8 Kg ha(-1) year(-1) at most stations, with the lowest deposition at the control station and Alcoi. The relative dry deposition with respect to the total was over 40% at most stations, going up to 75% at the southern station. N-deposition is expected to be higher considering that N-NH4+ deposition has been underestimated in this study.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Nitrogênio/análise , Clima Desértico , Região do Mediterrâneo , Pinus , Sulfatos/análise
13.
Environ Pollut ; 106(3): 359-67, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15093032

RESUMO

This work focuses on bulk deposition in a rural area located around a large coal-fired power station in northeast Spain. Deposition chemistry was characterised by high concentrations of SO(4)(2-), Ca(2+) and NH(4)(+), which were relatively high when compared with other rural areas. Monthly bulk deposition evolution of major ions was the result of two superimposed patterns: one pattern related to the volume of precipitation and the other showed the seasonal influence of the major ionic sources. A major local origin was attributed to bulk deposition of SO(4)(2-), NH(4)(+), and Ca(2+), whereas a relatively higher contribution of an external source was deduced for NO(3)(-), Na(+) and Cl(-). The SO(4)(2-) concentrations showed a significant correlation with the local SO(2) emissions. High levels of Ca(2+) were due to the high alkalinity of soils in the study area, although an external origin was attributed to the frequent air mass intrusions from the Sahara. Sources of NH(4)(+) were related to intensive livestock farming in the area. Total suspended particles exert a marked influence over bulk deposition and neutralisation. Thus, despite the high emissions of SO(2) in the area, neutral pH values have always been attained given that the concentrations of Ca(2+) and NH(4)(+) account for the total neutralisation of NO(3)(-) and SO(4)(2-).

14.
Nouv Rev Fr Hematol (1978) ; 25(6): 369-73, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6198618

RESUMO

A total of 200 cases of thalassaemia trait, 102 of F thalassaemia and 98 of A2 thalassaemia were studied, evaluating haematometric, and morphological aspects of both groups. Significantly higher values were found in F thalassaemia for PCV, MCV and MCH, with 33.5% of women and 52% of men being found anaemic in F thalassaemia and 45% of women and 62% of men in A2 thalassaemia. Asthenia was usually present in A2 thalassaemia more so in women 50.9% as compared to 25% in man. Only 4% of F thalassaemia carriers were affected by asthenia. Cholecystectomy had been performed on 10% of the A2 thalassaemia group and on 5% of the F thalassaemia thamia group. Both groups show a high proportion of red cells with basophilic stippling (80%), the groups being morphologically indistinguishable. Intrafamilial segregation of Hb F values affected 22% of families carriers of F thalassaemia, whereas only 8% of families carriers of A2 thalassaemia showed segregation of HbA2 values. The values obtained in this study were compared with those of other authors.


Assuntos
Hemoglobinas/análise , Talassemia/sangue , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Índices de Eritrócitos , Feminino , Hemoglobina Fetal/análise , Triagem de Portadores Genéticos , Hematócrito , Hemoglobina A2/análise , Humanos , Masculino , Pessoa de Meia-Idade , Talassemia/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...