Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 248
Filtrar
1.
Rev Cardiovasc Med ; 25(8): 305, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39228483

RESUMO

Atrial high-rate episodes (AHREs) and subclinical atrial fibrillation (AF) are frequently registered in asymptomatic patients with cardiac implantable electronic devices (CIEDs) and insertable cardiac monitors (ICMs). While an increased risk of thromboembolic events (e.g., stroke) and benefits from anticoagulation have been widely assessed in the setting of clinical AF, concerns persist about optimal clinical management of subclinical AF/AHREs. As a matter of fact, an optimal threshold of subclinical episodes' duration to predict stroke risk is still lacking and recently published randomized clinical trials assessing the impact of anticoagulation on thromboembolic events in this specific setting have shown contrasting results. The aim of this review is to summarize current evidence regarding classification and clinical impact of subclinical AF/AHREs and to discuss the latest evidence regarding the potential benefit of anticoagulation in this setting, highlighting which clinical questions are still unanswered.

3.
J Am Coll Cardiol ; 84(10): 921-933, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39197982

RESUMO

BACKGROUND: Young (<18 years of age) patients with Brugada syndrome (BrS) are often under-represented in BrS studies and their management, especially related to syncopal episodes, remains unclear. OBJECTIVES: This study sought to describe the arrhythmia prevalence among young patients with BrS undergoing continuous rhythm monitoring by implantable loop recorder (ILR) and to assess the etiology behind syncope of undetermined origin. METHODS: A total of 147 patients with BrS with ILR were enrolled in 12 international centers and divided into pediatric (age <12 years; n = 77, 52%) and adolescents (age 13-18 years; n = 70, 48%). RESULTS: Mean age was 11.3 years, 53 patients (36.1%) were female, and 31 (21.1%) had spontaneous type 1 electrocardiograms. Over a median follow-up of 3.6 years (Q1-Q3: 1.6-4.8 years), an arrhythmic event was recorded in 33 patients (22.4%), mainly of nonventricular origin: 15 atrial (10.2%) and 16 bradyarrhythmic events (10.9%). Ventricular arrhythmias occurred in 4 patients, all with spontaneous BrS, and were fever-related in one-half. Among all patients with recurrence of syncope during follow-up, true arrhythmic syncope was documented in 5 (17.8%), and it was due to bradyarrhythmias or atrial arrhythmias in 3 cases (60%). CONCLUSIONS: Continuous rhythm monitoring with ILRs in young patients with BrS detects a broad range of arrhythmias. Ventricular arrhythmias occur predominantly in patients with spontaneous type 1 electrocardiograms and during fever. Despite the young age, bradyarrhythmias and atrial arrhythmias are frequent and represent the cause of arrhythmic syncope in 60% of patients. Young patients with BrS with syncope of undetermined origin may benefit from ILR implant.


Assuntos
Síndrome de Brugada , Eletrocardiografia Ambulatorial , Humanos , Adolescente , Feminino , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/complicações , Criança , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Seguimentos , Síncope/diagnóstico , Síncope/etiologia , Síncope/fisiopatologia
4.
Heart Rhythm ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39117003

RESUMO

BACKGROUND: Recurrence during the 3-month blanking period after radiofrequency ablation of atrial fibrillation (AF) is typically not considered as a predictor for late recurrence. OBJECTIVE: We investigated the significance of early recurrence as a risk factor for late recurrence in patients with AF receiving pulsed-field ablation (PFA). METHODS: Consecutive patients undergoing PFA were prospectively followed up for 1 year. All patients received isolation of pulmonary veins. Additional ablation procedures were performed per operator's discretion. After the procedure, all remained on their previously ineffective antiarrhythmic drugs (AADs) during the 2-month blanking period after which the AADs were discontinued. Early recurrence was defined as atrial arrhythmia of >30-second duration during the 3-month blanking period, and any recurrence beyond 3 months was considered as late recurrence. RESULTS: A total of 337 patients undergoing PFA for AF were included. Early recurrence was recorded in 53 patients (15.7%): 10 in the first month, 12 in the second month, and 31 in the third month. Of the 10 patients having recurrence during the first month, 7 (70%) remained in sinus rhythm after cardioversion whereas 3 (30%) underwent a redo procedure because of late recurrence. At 1 year, all patients with recurrence in the second and third months experienced late recurrence; among these patients, 10 (83.3%) of 12 and 27 (87%) of 31 underwent a redo procedure and the remaining 6 patients were in sinus rhythm on AADs. CONCLUSION: In this consecutive series of patients with AF, early recurrence in the second or third month after the PFA procedure was associated with a high risk of late recurrence. Thus, blanking period could be redefined as 1 month after PFA.

5.
Circ Arrhythm Electrophysiol ; : e012788, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39171384

RESUMO

BACKGROUND: Sustained ventricular tachycardia (VT) in cardiac amyloidosis is uncommon, and the substrate and outcomes of catheter ablation are not defined. METHODS: We included 22 consecutive patients (mean age, 68±10 years; male sex, 91%) with cardiac amyloidosis (ATTR [transthyretin], n=16; light chain, n=6) undergoing catheter ablation for VT/ventricular fibrillation (VF) between 2013 and 2023 in a retrospective, observational, international study. The primary efficacy outcome was recurrent VT/VF during follow-up, while the primary safety end point included major procedure-related adverse events. RESULTS: The indication for ablation was drug-refractory VT in 17 patients (77%), and premature ventricular complex-initiated polymorphic VT/VF in 5 patients (23%). Catheter ablation was performed using endocardial (n=17.77%) or endo-epicardial approaches (n=5.23%). Complete endocardial electroanatomical voltage maps of the left and right ventricles were obtained in 17 (77%) and 10 (45%) patients, respectively. Each patient had evidence of low-voltage areas, most commonly involving the interventricular septum (n=16); late potentials were recorded in 16 patients (73%). A median of 1 (1-2) VT was inducible per patient; 12 of the 26 mappable VTs (46%) originated from the interventricular septum. Complete procedural success was achieved in 16 patients (73%), with 4 (18%) major procedure-related adverse events. After a median follow-up of 32 (14-42) months, sustained VT/VF recurrence was observed in 9 patients (41%); survival free from VT/VF recurrence was 56% (95% CI, 36%-86%) at 36-month follow-up, and most patients remained on antiarrhythmic drugs. A significant reduction in per patient implantable cardioverter defibrillator therapies was noted in the 6-month period after ablation (before: 6 [4-9] versus after: 0 [0-0]; P<0.001). In multivariable analysis, complete procedural success was associated with reduced risk of recurrent VT/VF (hazard ratio, 0.002; P=0.034). CONCLUSIONS: Catheter ablation can achieve control of recurrent VT/VF in more than half of patients with cardiac amyloidosis, and the reduction in VT/VF burden post-ablation may be relevant for quality of life. Septal substrate and risk of procedure-related complications challenge successful management of patients with cardiac amyloidosis and VT/VF.

6.
Eur Heart J ; 45(32): 2968-2979, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39011630

RESUMO

BACKGROUND AND AIMS: Pathogenic desmoplakin (DSP) gene variants are associated with the development of a distinct form of arrhythmogenic cardiomyopathy known as DSP cardiomyopathy. Patients harbouring these variants are at high risk for sustained ventricular arrhythmia (VA), but existing tools for individualized arrhythmic risk assessment have proven unreliable in this population. METHODS: Patients from the multi-national DSP-ERADOS (Desmoplakin SPecific Effort for a RAre Disease Outcome Study) Network patient registry who had pathogenic or likely pathogenic DSP variants and no sustained VA prior to enrolment were followed longitudinally for the development of first sustained VA event. Clinically guided, step-wise Cox regression analysis was used to develop a novel clinical tool predicting the development of incident VA. Model performance was assessed by c-statistic in both the model development cohort (n = 385) and in an external validation cohort (n = 86). RESULTS: In total, 471 DSP patients [mean age 37.8 years, 65.6% women, 38.6% probands, 26% with left ventricular ejection fraction (LVEF) < 50%] were followed for a median of 4.0 (interquartile range: 1.6-7.3) years; 71 experienced first sustained VA events {2.6% [95% confidence interval (CI): 2.0, 3.5] events/year}. Within the development cohort, five readily available clinical parameters were identified as independent predictors of VA and included in a novel DSP risk score: female sex [hazard ratio (HR) 1.9 (95% CI: 1.1-3.4)], history of non-sustained ventricular tachycardia [HR 1.7 (95% CI: 1.1-2.8)], natural logarithm of 24-h premature ventricular contraction burden [HR 1.3 (95% CI: 1.1-1.4)], LVEF < 50% [HR 1.5 (95% CI: .95-2.5)], and presence of moderate to severe right ventricular systolic dysfunction [HR 6.0 (95% CI: 2.9-12.5)]. The model demonstrated good risk discrimination within both the development [c-statistic .782 (95% CI: .77-.80)] and external validation [c-statistic .791 (95% CI: .75-.83)] cohorts. The negative predictive value for DSP patients in the external validation cohort deemed to be at low risk for VA (<5% at 5 years; n = 26) was 100%. CONCLUSIONS: The DSP risk score is a novel model that leverages readily available clinical parameters to provide individualized VA risk assessment for DSP patients. This tool may help guide decision-making for primary prevention implantable cardioverter-defibrillator placement in this high-risk population and supports a gene-first risk stratification approach.


Assuntos
Desmoplaquinas , Humanos , Desmoplaquinas/genética , Feminino , Masculino , Medição de Risco/métodos , Adulto , Pessoa de Meia-Idade , Arritmias Cardíacas/genética , Heterozigoto , Taquicardia Ventricular/genética
7.
Heart Rhythm O2 ; 5(6): 374-384, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38984361

RESUMO

Background: Posterior wall ablation (PWA) is commonly added to pulmonary vein isolation (PVI) during catheter ablation (CA) of persistent atrial fibrillation (AF). Objective: The purpose of this study was to compare PVI plus PWA using very-high-power short-duration (vHPSD) vs standard-power (SP) ablation index-guided CA among consecutive patients with persistent AF and to determine the voltage correlation between microbipolar and bipolar mapping in AF. Methods: We compared 40 patients undergoing PVI plus PWA using vHPSD to 40 controls receiving PVI plus PWA using SP. The primary efficacy endpoint was recurrence of atrial tachyarrhythmias after a 3-month blanking period. The primary safety outcome was a composite of major complications within 30 days after CA. In the vHPSD group, high-density mapping of the posterior wall was performed using both a multipolar catheter and microelectrodes on the tip of the ablation catheter. Results: PVI was more commonly obtained with vHPSD compared to SP ablation (98%vs 75%; P = .007), despite shorter procedural and fluoroscopy times (P <.001). Survival free from recurrent atrial tachyarrhythmias at 18 months was 68% and 47% in the vHPSD and SP groups, respectively (log-rank P = .071), without major adverse events. The vHPSD approach was significantly associated with reduced risk of recurrent AF at multivariable analysis (hazard ratio 0.39; P = .030). Microbipolar voltage cutoffs of 0.71 and 1.69 mV predicted minimum bipolar values of 0.16 and 0.31 mV in AF, respectively, with accuracies of 0.67 and 0.88. Conclusion: vHPSD PWA plus PVI may be faster and as safe as SP CA among patients with persistent AF, with a trend for superior efficacy. Adapted voltage cutoffs should be used for identifying atrial low-voltage areas with microbipolar mapping.

8.
J Cardiovasc Med (Hagerstown) ; 25(8): 601-608, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949147

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) represents an effective heart failure treatment, associated with reduction in mortality and heart failure hospitalizations. This Italian survey aimed to address relevant CRT issues. METHODS: An online survey was administered to AIAC members. RESULTS: One hundred and five electrophysiologists participated, with a median of 40 (23-70) CRT implantations/year (33% in high-volume centres). Forty-five percent of respondents (especially working in high-volume centres) reported an increase in CRT implantations in the last 2 years, in 16% a decrease, and in 38% CRT remained stable. Seventy-five percent of respondents implanted CRT only in patients with European Heart Rhythm Association (EHRA) class I indications. All operators collected ECG and echocardiography before implantation. Eighty-five percent of respondents selected coronary sinus target vein empirically, whereas 10% used mechanical and/or electrical delay techniques. Physicians working in high-volume centres reported a lower failure rate compared with others (16 vs. 34%; P = 0.03). If the coronary sinus lead could not be positioned in the target branch, 80% placed it in another vein, whereas 16% opted for a surgical approach or for conduction system pacing (CSP). Eighty percent accomplished CRT optimization in all patients, 17% only in nonresponders. Regarding anticoagulation, high agreement with EHRA guidelines emerged. CONCLUSION: CRT represents a valid therapeutic option in heart failure treatment. Nowadays, CRT implantations remain stable and are mainly performed in patients with class I indications. ECG remains the preferred tool for patient selection, whereas imaging is increasingly used to determine the left pacing target area. In most patients, the left ventricular lead can be successfully positioned in the target vein, but in some cases, the result can be unsatisfactory; however, the decision to explore alternative resynchronization approaches is rarely pursued.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Seleção de Pacientes , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Itália/epidemiologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Pesquisas sobre Atenção à Saúde , Dispositivos de Terapia de Ressincronização Cardíaca , Padrões de Prática Médica/tendências , Padrões de Prática Médica/estatística & dados numéricos , Eletrocardiografia , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Resultado do Tratamento , Inquéritos e Questionários
9.
JACC Adv ; 3(3): 100832, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938828

RESUMO

Background: Patients with likely pathogenic/pathogenic desmoplakin (DSP) variants are poorly characterized. Some of them meet diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC), but it is unclear how risk stratification strategies for ARVC perform in this setting. Objectives: The purpose of this study was to characterize arrhythmic outcomes and to test the performance of the recently validated ARVC risk calculator in patients with DSP likely pathogenic/pathogenic variants fulfilling definite 2010 ARVC Task Force Criteria (DSP-TFC+). Methods: DSP-TFC+ patients were enrolled from 20 institutions across 3 continents. Ventricular arrhythmias (VA), defined as a composite of sustained ventricular tachycardia (VT), appropriate implantable cardioverter defibrillator therapies, and ventricular fibrillation/sudden cardiac death events in follow-up, were reported as the primary outcome. We tested the performance of the ARVC risk calculator for VA prediction, reporting c-statistics. Results: Among 252 DSP-TFC+ patients (age 39.6 ± 16.9 years, 35.3% male), 94 (37.3%) experienced VA over 44.5 [IQR: 19.6-78.3] months. Patients with left ventricle involvement (n = 194) were at higher VA risk (log-rank P = 0.0239). History of nonsustained VT (aHR 2.097; P = 0.004) showed the strongest association with VA occurrence during the first 5-year follow-up. Neither age (P = 0.723) nor male sex (P = 0.200) was associated with VAs at follow-up. In 204 patients without VA at diagnosis, incident VA rate was high (32.8%; 7.37%/y). The ARVC risk calculator performed poorly overall (c-statistic 0.604 [0.594-0.614]) and very poorly in patients with left ventricular disease (c-statistic 0.558 [0.556-0.560]). Conclusions: DSP-TFC+ patients are at substantial risk for VAs. The ARVC risk calculator performs poorly in DSP-TFC+ patients suggesting need for a gene-specific risk algorithm. Meanwhile, DSP-TFC+ patients with nonsustained VT should be considered as high-risk.

10.
Heart Rhythm ; 21(9): 1526-1536, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38810922

RESUMO

BACKGROUND: Pulsed field ablation (PFA) and very high-power short-duration (vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA vs vHPSD are currently unknown. OBJECTIVE: The study aimed to compare PFA with vHPSD for the treatment of paroxysmal or persistent AF. METHODS: We conducted an observational, multicenter study enrolling 534 consecutive patients (63 ± 9 years; 36% female) with paroxysmal (n = 368 [69%]) or persistent (n = 166 [31%]) AF undergoing ablation by either PFA (Farapulse; n = 192) or vHPSD (90 W/4 seconds; QDOT Micro; n = 342) between 2020 and 2023. Atrial tachyarrhythmia recurrence after a 1-month blanking period was the primary efficacy end point and was assessed both overall and in propensity score-matched patients. The primary safety end point was a composite of procedure-related complications. RESULTS: Successful pulmonary vein isolation was achieved in all patients, with shorter procedure duration (PFA,70 minutes; vHPSD, 100 minutes; P < .001) but longer fluoroscopy time (PFA, 15 minutes; vHPSD, 7 minutes; P < .001) in the PFA group. PFA was associated with more frequent use of general anesthesia (P < .001). Primary safety outcome events occurred in 19 patients (3.5%), with similar prevalence in both groups (PFA, 4%; vHPSD, 3%; P = .745). After a median follow-up of 12 (9-12) months, survival free from recurrent atrial tachyarrhythmia was similar between the PFA and vHPSD groups, both overall (12-month estimate: PFA, 75%; vHPSD, 76%; log-rank P = .73) and in propensity score-matched patients (n = 342; 12-month estimate: PFA, 75%; vHPSD, 77%; log-rank P = .980). CONCLUSION: In a large, multicenter experience, PFA was associated with more common use of general anesthesia, shorter procedural times, and longer fluoroscopy exposure compared with vHPSD ablation, with both techniques displaying superimposable safety and efficacy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fatores de Tempo , Seguimentos , Recidiva , Idoso , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Pontuação de Propensão
11.
Artigo em Inglês | MEDLINE | ID: mdl-38814525

RESUMO

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

12.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38674168

RESUMO

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/normas , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Arritmias Cardíacas/diagnóstico por imagem
13.
J Clin Med ; 13(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38592178

RESUMO

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

15.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
16.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38674259

RESUMO

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Assuntos
Amiloidose , Cardiomiopatias , Cicatriz , Imageamento por Ressonância Magnética , Humanos , Masculino , Projetos Piloto , Feminino , Cardiomiopatias/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Amiloidose/complicações , Idoso , Cicatriz/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Software
17.
J Clin Med ; 13(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610635

RESUMO

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

18.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
19.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
20.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...