Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
2.
Pacing Clin Electrophysiol ; 43(6): 593-601, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32333406

RESUMO

BACKGROUND: Pericardial access is complicated by two difficulties: confirming when the needle tip is in the pericardial space, and avoiding complications during access, such as inadvertently puncturing other organs. Conventional imaging tools are inadequate for addressing these difficulties, as they lack soft-tissue markers that could be used as guidance during access. A system that can both confirm access and avoid inadvertent organ injury is needed. METHODS: A 21G micropuncture needle was modified to include two small electrodes at the needle tip. With continuous bioimpedance monitoring from the electrodes, the needle was used to access the pericardium in porcine models (n  =  4). The needle was also visualized in vivo by using an electroanatomical map (n  =  2). Bioimpedance data from different tissues were analyzed retrospectively. RESULTS: Bioimpedance data collected from the subcutaneous space (992.8 ± 13.1 Ω), anterior mediastinum (972.2 ± 14.2 Ω), pericardial space (323.2 ± 17.1 Ω), mid-myocardium (349.7 ± 87.6 Ω), right ventricular cavity (235.0 ± 9.7 Ω), lung (1142.0 ± 172.0 Ω), liver (575.0 ± 52.6 Ω), and blood (177.5 ± 1.9 Ω) differed significantly by tissue type (P < .01). Phase data in the frequency domain correlated well with the needle being in the pericardial space. A simple threshold analysis effectively separated lung (threshold  =  1120.0 Ω) and blood (threshold  =  305.9 Ω) tissues from the other tissue types. CONCLUSIONS: Continuous bioimpedance monitoring from a modified micropuncture needle during pericardial access can be used to clearly differentiate tissues. Combined with traditional imaging modalities, this system allows for confirming access to the pericardial space while avoiding inadvertent puncture of other organs, creating a safer and more efficient needle-access procedure.


Assuntos
Pericárdio/cirurgia , Punções/instrumentação , Punções/métodos , Animais , Impedância Elétrica , Desenho de Equipamento , Agulhas , Suínos
3.
Artif Organs ; 40(12): 1105-1112, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27187888

RESUMO

To investigate longitudinal trends in valvular and ventricular function with long-term left ventricular assist device (LVAD) therapy, we analyzed hemodynamic and echocardiographic data of patients with at least 2 years of continuous LVAD support. All 130 patients who underwent HeartMate II implantation at our institution between 2005 and 2012 were reviewed. Twenty patients had hemodynamic and echocardiographic evaluations in both the early (0-6 months) and late (2-3 years) postoperative period. Patients on inotropic therapy or temporary mechanical support were excluded. The average times of early and late hemodynamic evaluations were 59 ± 41 days and 889 ± 160 days, respectively. Cardiac index (CI) declined by an average of 0.4 L/min/m2 (P = 0.04) with concomitant increase in pulmonary capillary wedge pressure (PCWP; P = 0.02). The right atrial pressure to PCWP (RAP:PCWP) ratio decreased during LVAD support suggesting improvement in right ventricular function. While there was an increase in degree of aortic insufficiency (AI) at the late follow-up period (P = 0.008), dichotomization by median decline in CI (-0.4 L/min/m2 ) indicated no difference in prevalence of AI among the groups. CI declined in patients with HeartMate II after 2 years of continuous support. An increase in preload and afterload was observed in those with the greatest decline in CI.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Adulto , Ecocardiografia , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Implantação de Prótese
5.
J Invasive Cardiol ; 24(7): E135-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22781482

RESUMO

Percutaneous and surgical procedures intended to potentially cure atrial fibrillation require creating lines of conduction block in specific locations throughout the atrial chambers. In patients presenting with recurrent atrial fibrillation, repeat procedures are often performed, resulting in more extensive regions of conduction block and the potential for regions of dissociated atrial rhythms. The present case describes a patient post-multiple ablation procedures who presented with a symptomatic atrial arrhythmia, the mechanism of which was hidden by the presence of extensive atrial dissociation. Electrophysiologic study revealed the appropriate mechanism and a beneficial ablative procedure was then successfully accomplished.


Assuntos
Arritmia Sinusal/complicações , Flutter Atrial/etiologia , Síndrome do Nó Sinusal/complicações , Idoso , Arritmia Sinusal/fisiopatologia , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Humanos , Masculino , Síndrome do Nó Sinusal/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...