Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Inflammopharmacology ; 32(1): 393-404, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37429999

RESUMO

Medulla Tetrapanacis (MT) is a commonly used herb to promote lactation and manage mastitis in lactating mothers. However, its anti-inflammatory and anti-bacterial effects are currently unknown. We hypothesized that MT water extract possesses anti-inflammatory and anti-bacterial effects by modulating macrophage polarization to reduce the release of inflammatory mediators and phagocytosis via inactivation of MAPKs pathways. The chemical composition of the MT water extract was analyzed by UPLC-Orbitrap-mass spectrometry. The anti-inflammatory and anti-bacterial properties of the MT water extract were examined using LPS-stimulated inflammation and Staphylococcus aureus infection model in RAW 264.7 cells, respectively. The underlying mechanism of action of the MT water extract was also investigated. We identified eight compounds by UPLC-Orbitrap-mass spectrometry that are abundant within the MT water extract. MT water extract significantly suppressed LPS-induced nitric oxide, TNF-α and IL-6 secretion in RAW 264.7 cells which was accompanied by the promotion of macrophage polarization from pro-inflammatory towards anti-inflammatory phenotypes. MT water extract significantly suppressed the LPS-induced MAPK activation. Finally, MT water extract decreased the phagocytic capacity of the RAW 264.7 cells against S. aureus infection. MT water extract could suppress LPS-induced inflammation by promoting macrophages towards an anti-inflammatory phenotype. In addition, MT also inhibited the growth of S. aureus.


Assuntos
Lactação , Lipopolissacarídeos , Feminino , Humanos , Lipopolissacarídeos/farmacologia , Staphylococcus aureus , Transdução de Sinais , Inflamação/tratamento farmacológico , Macrófagos , Anti-Inflamatórios/farmacologia
2.
J Vasc Interv Radiol ; 34(12): 2208-2212, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37652297

RESUMO

This study aimed to investigate the feasibility of ultrasound (US)-guidance in reducing adverse event (AE) rates when using Angioseal device during antegrade lower limb angioplasty via common femoral artery access. From December 2016 to November 2022, 1,322 patients were identified, including 1,131 (85.6%) patients who underwent US-guided closure and 191 (14.4%) who underwent non-US-guided closure. Moderate AEs were encountered in 10 (5.2%) patients in the non-US-guided closure group compared to 38 (3.4%) patients in the US-guided closure group (P = .208). Severe AEs were encountered in 4 (2.1%) patients in the non-US-guided closure group compared to 3 (0.3%) patients in the US-guided closure group (P = .010). Overall AEs occurred in 14 (7.3%) patients in the non-US-guided closure group compared to 41 (3.6%) patients in the US-guided closure group (P = .029). Binary logistic regression showed that only non-US guidance was an independent risk factor for the occurrence of severe AEs (P = .008).


Assuntos
Artéria Femoral , Técnicas Hemostáticas , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Resultado do Tratamento , Punções , Extremidade Inferior , Estudos Retrospectivos
3.
JHEP Rep ; 5(9): 100793, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37575885

RESUMO

Background & Aims: Rat hepatitis E virus (Rocahepevirus ratti; HEV-C1) is an emerging cause of hepatitis E that is divergent from conventional human-infecting HEV variants (Paslahepevirus balayani; HEV-A). Validated serological assays for HEV-C1 are lacking. We aimed to develop a parallel enzymatic immunoassay (EIA) system that identifies individuals with HEV-C1 exposure. We also aimed to conduct the first HEV-C1 seroprevalence study in humans using this validated EIA system. Methods: Expressed HEV-A (HEV-A4 p239) and HEV-C1 (HEV-C1 p241) peptides were characterised. Blood samples were simultaneously tested in HEV-A4 p239 and HEV-C1 p241 IgG EIAs. An optical density (OD) cut-off-based interpretation algorithm for identifying samples seropositive for HEV-A or HEV-C1 was validated using RT-PCR-positive infection sera. This algorithm was used to measure HEV-C1 seroprevalence in 599 solid organ transplant recipients and 599 age-matched immunocompetent individuals. Results: Both peptides formed virus-like particles. When run in HEV-A4 p239 and HEV-C1 p241 EIAs, HEV-A and HEV-C1 RT-PCR-positive samples formed distinct clusters with minimal overlap in a two-dimensional plot of optical density values. The final EIA interpretation algorithm showed high agreement with RT-PCR results (Cohen's κ = 0.959) and was able to differentiate HEV-A and HEV-C1 infection sera with an accuracy of 94.2% (95% CI: 85.8-98.4%). HEV-C1 IgG seroprevalence was 7/599 (1.2%) among solid organ transplant recipients and 4/599 (0.7%) among immunocompetent individuals. Five of 11 (45.5%) of these patients had history of transient hepatitis of unknown cause. Conclusions: HEV-C1 exposure was identified in 11/1198 (0.92%) individuals in Hong Kong indicating endemic exposure. This is the first estimate of HEV-C1 seroprevalence in humans. The parallel IgG EIA algorithm is a valuable tool for investigating epidemiology and risk factors for HEV-C1 infection. Impact and Implications: Rat hepatitis E virus has recently been discovered to infect humans, but antibody tests for this infection are lacking, making it difficult to gauge how common this infection is. We developed an antibody test algorithm that can identify individuals with past rat hepatitis E virus exposure. We used this algorithm to estimate rat hepatitis E exposure rates in humans in Hong Kong and found that approximately 1% of all tested people had been exposed to this virus previously.

6.
Front Pharmacol ; 13: 981152, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36147350

RESUMO

Ageing is a risk factor for many degenerative diseases. Cardiovascular diseases (CVDs) are usually big burdens for elderly, caregivers and the health system. During the aging process, normal functions of vascular cells and tissue progressively lost and eventually develop vascular diseases. Endothelial dysfunction, reduced bioavailability of endothelium-derived nitric oxide are usual phenomena observed in patients with cardiovascular diseases. Myriad of studies have been done to investigate to delay the vascular dysfunction or improve the vascular function to prolong the aging process. Tumor suppressor gene p53, also a transcription factor, act as a gatekeeper to regulate a number of genes to maintain normal cell function including but not limited to cell proliferation, cell apoptosis. p53 also crosstalk with other key transcription factors like hypoxia-inducible factor 1 alpha that contribute to the progression of cardiovascular diseases. Therefore, in recent three decades, p53 has drawn scientists' attention on its effects in vascular function. Though the role of tumor suppressor gene p53 is still not clear in vascular function, it is found to play regulatory roles and may involve in vascular remodeling, atherosclerosis or pulmonary hypertension. p53 may have a divergent role in endothelial and vascular muscle cells in those conditions. In this review, we describe the different effects of p53 in cardiovascular physiology. Further studies on the effects of endothelial cell-specific p53 deficiency on atherosclerotic plaque formation in common animal models are required before the therapeutic potential can be realized.

7.
Mar Drugs ; 20(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35877723

RESUMO

Lectins are a unique group of nonimmune carbohydrate-binding proteins or glycoproteins that exhibit specific and reversible carbohydrate-binding activity in a non-catalytic manner. Lectins have diverse sources and are classified according to their origins, such as plant lectins, animal lectins, and fish lectins. Marine organisms including fish, crustaceans, and mollusks produce a myriad of lectins, including rhamnose binding lectins (RBL), fucose-binding lectins (FTL), mannose-binding lectin, galectins, galactose binding lectins, and C-type lectins. The widely used method of extracting lectins from marine samples is a simple two-step process employing a polar salt solution and purification by column chromatography. Lectins exert several immunomodulatory functions, including pathogen recognition, inflammatory reactions, participating in various hemocyte functions (e.g., agglutination), phagocytic reactions, among others. Lectins can also control cell proliferation, protein folding, RNA splicing, and trafficking of molecules. Due to their reported biological and pharmaceutical activities, lectins have attracted the attention of scientists and industries (i.e., food, biomedical, and pharmaceutical industries). Therefore, this review aims to update current information on lectins from marine organisms, their characterization, extraction, and biofunctionalities.


Assuntos
Organismos Aquáticos , Lectinas de Plantas , Animais , Peixes , Galectinas , Glicoproteínas , Lectinas Tipo C
9.
J Ren Nutr ; 32(3): 347-353, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33941439

RESUMO

OBJECTIVE: Obesity is prevalent in patients with chronic kidney disease and is associated with increased complications after kidney transplantation (KT). A body mass index limit is used in most transplant programs, though few studies have focused on conservative weight loss in KT candidates. The objective of this retrospective study is to evaluate the efficacy of a basic conservative weight management program in morbidly obese KT candidates and to perform a comprehensive nutritional evaluation. METHODS: This retrospective study included patients with a body mass index (BMI) >35 kg/m2, with grade IV or V chronic kidney disease. The conservative weight loss program consisted of anthropometric measurements every 3 months, consultation with a nutritionist, daily exercise, and counseling for healthier eating habits. Overall and quarterly BMI targets were defined. A subset of patients further underwent a comprehensive nutritional evaluation to measure socioeconomic characteristics, food intake behavior, motivation for change, and a 4-day food diary. RESULTS: Eighty patients were observed for a mean of 24 months. Successful weight loss (BMI < 35 kg/m2) was achieved in 26.3%, associated with women and those already close to the limit. The mean 1-year excess body weight loss was 8.4%. No patient with a BMI >40 kg/m2 was successful. The comprehensive nutritional evaluation was performed with 44 patients and found that only 14.6% had previously received nutritional counseling for weight loss. Cognitive restraint scored highest in the food-intake behavior. Most patients were motivated to lose weight with 66% in the action phase. There was little evidence of overeating with a recommended mean calculated daily caloric intake of 82.9%. CONCLUSION: The conservative weight loss program can have limited but non-negligible, success. Future successful nutritional interventions should take into consideration this surprising comprehensive profile of morbidly obese KT candidates.


Assuntos
Transplante de Rim , Obesidade Mórbida , Insuficiência Renal Crônica , Índice de Massa Corporal , Tratamento Conservador , Feminino , Humanos , Masculino , Obesidade Mórbida/complicações , Obesidade Mórbida/terapia , Insuficiência Renal Crônica/complicações , Estudos Retrospectivos , Redução de Peso
10.
J Belg Soc Radiol ; 105(1): 25, 2021 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-33987526

RESUMO

This article demonstrates the technique of using a coaxial guiding needle to perform combined percutaneous biopsy and microwave ablation via a single tract. From May 2019 to July 2020, 14 patients underwent combined biopsy and microwave ablation by using a coaxial guiding cannula. Tumors were in the kidney of six patients (43%), the liver of six patients (43%), and the lung in two patients (14%). The diagnostic yield of biopsy was 86% (12/14). Ablation technical success rate was 100%. In conclusion, using a coaxial guiding needle in microwave ablation and biopsy is safe and effective.

11.
Am J Case Rep ; 22: e929048, 2021 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-33750755

RESUMO

BACKGROUND Malignant disease is a common etiology of superior vena cava syndrome (SVCS). Being a medical emergency, it often requires rapid diagnostic evaluation and therapy. Transcaval biopsy and endovascular stenting in a single-setting has been described, but only in a handful of cases. These cases utilized intra-operative venograms. In this study, we also used intra-operative cone beam computed tomography (CBCT) to increase the safety and efficacy of such single-setting procedures. CASE REPORT From January 2017 to July 2019, there were 5 patients with malignant SVCS who underwent single-setting superior vena cava biopsy and endovascular stenting utilizing intra-operative CBCT as an adjunct. Demographic data, clinical presentation, investigation results, procedural details, and patient outcomes were recorded. CBCT was utilized in all cases to optimize sampling of biopsies, visualize subsequent stent positioning, and for early detection of procedure-related complications. Transcaval biopsy was diagnostic in 4 of the 5 patients. Endovascular stents were deployed successfully in all cases, with post-stenting venogram demonstrating relief of prior obstructed segments. One patient had a complication of an apical pneumothorax, with no associated long-term pneumothorax-related morbidity or mortality. CONCLUSIONS This study demonstrates that single-setting transcaval biopsy and stenting in the context of malignant SVCS is a cost-efficient, safe, and feasible approach. In addition, the additional use of intra-operative CBCT is a useful tool to increase procedure efficacy and safety.


Assuntos
Síndrome da Veia Cava Superior , Veia Cava Superior , Biópsia , Tomografia Computadorizada de Feixe Cônico , Humanos , Stents , Síndrome da Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/etiologia , Síndrome da Veia Cava Superior/cirurgia , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
12.
Transpl Int ; 34(5): 964-973, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33630394

RESUMO

Morbid obesity in kidney transplant (KT) candidates is associated with increased complications and graft failure. Multiple series have demonstrated rapid and significant weight loss after laparoscopic sleeve gastrectomy (LSG) in this population. Long-term and post-transplant weight evolutions are still largely unknown. A retrospective review was performed in eighty patients with end-stage kidney disease (ESKD) who underwent LSG in preparation for KT. From a median initial BMI of 43.7 kg/m2 , the median change at 1-year was -10.0 kg/m2 . Successful surgical weight loss (achieving a BMI < 35 kg/m2 or an excess body weight loss >50%) was attained in 76.3% and was associated with male gender, predialysis status, lower obesity class and lack of coronary artery disease. Thirty-one patients subsequently received a KT with a median delay of 16.7 months. Weight regain (increase in BMI of 5 kg/m2 postnadir) and recurrent obesity (weight regain + BMI > 35) remain a concern, occurring post-KT in 35.7% and 17.9%, respectively. Early LSG should be considered for morbidly obese patients with ESKD for improved weight loss outcomes. Early KT after LSG does not appear to affect short-term surgical weight loss. Candidates with a BMI of up to 45 kg/m2 can have a reasonable expectation to achieve the limit within 1 year.


Assuntos
Transplante de Rim , Laparoscopia , Obesidade Mórbida , Índice de Massa Corporal , Gastrectomia , Humanos , Masculino , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
13.
Front Med (Lausanne) ; 7: 583331, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33344473

RESUMO

Hypertension affects an estimated 1.4 billion people and is a major cause of morbidity and mortality worldwide. Early diagnosis and intervention can potentially decrease cardiovascular events later in life. However, blood pressure (BP) measurements take time and require training for health care professionals. The measurements are also inconvenient for patients to access, numerous daily variables affect BP values, and only a few BP readings can be collected per session. This leads to an unmet need for an accurate, 24-h continuous, and portable BP measurement system. Electrocardiograms (ECGs) have been considered as an alternative way to measure BP and may meet this need. This review summarizes the literature published from January 1, 2010, to January 1, 2020, on the use of only ECG wave morphology to monitor BP or identify hypertension. From 35 articles analyzed (9 of those with no listed comorbidities and confounders), the P wave, QTc intervals and TpTe intervals may be promising for this purpose. Unfortunately, with the limited number of articles and the variety of participant populations, we are unable to make conclusions about the effectiveness of ECG-only BP monitoring. We provide 13 recommendations for future ECG-only BP monitoring studies and highlight the limited findings in pregnant and pediatric populations. With the advent of convenient and portable ECG signal recording in smart devices and wearables such as watches, understanding how to apply ECG-only findings to identify hypertension early is crucial to improving health outcomes worldwide.

14.
Nat Commun ; 11(1): 1969, 2020 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-32327649

RESUMO

Since 2013, China has implemented a large-scale initiative to systematically deploy solar photovoltaic (PV) projects to alleviate poverty in rural areas. To provide new understanding of China's targeted poverty alleviation strategy, we use a panel dataset of 211 pilot counties that received targeted PV investments from 2013 to 2016, and find that the PV poverty alleviation pilot policy increases per-capita disposable income in a county by approximately 7%-8%. The effect of PV investment is positive and significant in the year of policy implementation and the effect is more than twice as high in the subsequent two to three years. The PV poverty alleviation effect is stronger in poorer regions, particularly in Eastern China. Our results are robust to alternative specifications and variable definitions. We propose several policy recommendations to sustain progress in China's efforts to deploy PV for poverty alleviation.

15.
J Clin Med ; 9(4)2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32331360

RESUMO

Elevated blood pressure (BP) is a major cause of death, yet hypertension commonly goes undetected. Owing to its nature, it is typically asymptomatic until later in its progression when the vessel or organ structure has already been compromised. Therefore, noninvasive and continuous BP measurement methods are needed to ensure appropriate diagnosis and early management before hypertension leads to irreversible complications. Photoplethysmography (PPG) is a noninvasive technology with waveform morphologies similar to that of arterial BP waveforms, therefore attracting interest regarding its usability in BP estimation. In recent years, wearable devices incorporating PPG sensors have been proposed to improve the early diagnosis and management of hypertension. Additionally, the need for improved accuracy and convenience has led to the development of devices that incorporate multiple different biosignals with PPG. Through the addition of modalities such as an electrocardiogram, a final measure of the pulse wave velocity is derived, which has been proved to be inversely correlated to BP and to yield accurate estimations. This paper reviews and summarizes recent studies within the period 2010-2019 that combined PPG with other biosignals and offers perspectives on the strengths and weaknesses of current developments to guide future advancements in BP measurement. Our literature review reveals promising measurement accuracies and we comment on the effective combinations of modalities and success of this technology.

16.
J Clin Med ; 9(3)2020 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-32155976

RESUMO

One in three adults worldwide has hypertension, which is associated with significant morbidity and mortality. Consequently, there is a global demand for continuous and non-invasive blood pressure (BP) measurements that are convenient, easy to use, and more accurate than the currently available methods for detecting hypertension. This could easily be achieved through the integration of single-site photoplethysmography (PPG) readings into wearable devices, although improved reliability and an understanding of BP estimation accuracy are essential. This review paper focuses on understanding the features of PPG associated with BP and examines the development of this technology over the 2010-2019 period in terms of validation, sample size, diversity of subjects, and datasets used. Challenges and opportunities to move single-site PPG forward are also discussed.

17.
J Clin Transl Res ; 6(3): 94-96, 2020 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-33426360
18.
Am J Transplant ; 20(2): 582-588, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31529773

RESUMO

Laparoscopic sleeve gastrectomy induces weight loss via the creation of a restrictive gastric tube for early satiety and is associated with an accelerated gastric transit time. A prospective, single-dose pharmacokinetic study was performed, prior to and after laparoscopic sleeve gastrectomy, for tacrolimus, extended-release tacrolimus, mycophenolate mofetil, and enteric-coated mycophenolate sodium. The study included 12 morbidly obese patients in chronic renal failure. The median decrease in body mass index was 8.8 kg/m2 with an excess body weight loss of 54.9%. The AUC24 of all drugs were increased after laparoscopic sleeve gastrectomy by 46%, 55%, 77%, and 74%, respectively. The maximum concentrations were increased for tacrolimus, extended-release tacrolimus, and mycophenolate mofetil by 43%, 46%, and 65%. The apparent total clearances were decreased for tacrolimus, mycophenolate mofetil, and enteric-coated mycophenolate sodium by 36%, 57%, and 38%. Laparoscopic sleeve gastrectomy can be associated with significant changes in pharmacokinetics of the drugs evaluated. The mechanism is likely decreased apparent drug clearance due to an increased drug exposure (from a more distal site of intestinal absorption with decreased intestinal metabolism), or decreased clearance (liver metabolism). Adapting the monitoring of immunosuppression will be important to avoid overdosing and potential side effects.


Assuntos
Gastrectomia/métodos , Imunossupressores/farmacocinética , Ácido Micofenólico/farmacocinética , Tacrolimo/farmacocinética , Feminino , Humanos , Falência Renal Crônica/cirurgia , Laparoscopia , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Estudos Prospectivos
19.
J Clin Med ; 8(11)2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31683938

RESUMO

Hypertension is one of the most prevalent diseases and is often called the "silent killer" because there are usually no early symptoms. Hypertension is also associated with multiple morbidities, including chronic kidney disease and cardiovascular disease. Early detection and intervention are therefore important. The current routine method for diagnosing hypertension is done using a sphygmomanometer, which can only provide intermittent blood pressure readings and can be confounded by various factors, such as white coat hypertension, time of day, exercise, or stress. Consequently, there is an increasing need for a non-invasive, cuff-less, and continuous blood pressure monitoring device. Multi-site photoplethysmography (PPG) is a promising new technology that can measure a range of features of the pulse, including the pulse transit time of the arterial pulse wave, which can be used to continuously estimate arterial blood pressure. This is achieved by detecting the pulse wave at one body site location and measuring the time it takes for it to reach a second, distal location. The purpose of this review is to analyze the current research in multi-site PPG for blood pressure assessment and provide recommendations to guide future research. In a systematic search of the literature from January 2010 to January 2019, we found 13 papers that proposed novel methods using various two-channel PPG systems and signal processing techniques to acquire blood pressure using multi-site PPG that offered promising results. However, we also found a general lack of validation in terms of sample size and diversity of populations.

20.
Semin Intervent Radiol ; 36(3): 213-220, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31435129

RESUMO

Irreversible electroporation (IRE) is a relatively recent method of ablation. In contrast to many ablation devices that use thermal methods to induce cell death, IRE employs the use of an electric field to cause irreversible permeability of the cell membrane, thus inducing apoptosis. Since its use in the pancreas was first described in 2012, IRE has become established as part of the armamentarium of ablation devices currently available. The crucial advantage of IRE compared with other devices employing thermal ablation is the safety around vital structures such as vessels and ducts. This is especially important in the pancreas due to the close proximity of multiple major vascular structures, biliary ducts, and adjacent gastrointestinal organs. This article will explore the current evidence regarding the use of IRE in the pancreas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...