Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(9)2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39329785

RESUMO

Loop-mediated isothermal amplification (LAMP) has attracted significant attention for rapid and accurate point-of-care diagnostics. However, integrating sample introduction, lysis, amplification, and detection steps into an easy-to-use, disposable system has so far been challenging. This has limited the uptake of the technique in practical applications. In this study, we developed a colourimetric one-step LAMP assay that combines thermolysis and LAMP reaction, to detect the SARS-CoV-2 virus in nasopharyngeal swab samples from COVID-19-infected individuals. The limit of detection was 500 copies per reaction at 65 °C for 25 min in reaction tubes. Additionally, we developed a finger-operated capillary-driven microfluidic device with selective PVA coating. This finger-actuated microfluidic device could self-dose the required sample amount for the LAMP reaction and inhibit sample evaporation. Finally, we integrated the LAMP assay into the microfluidic device by short-term pre-storage of the LAMP master mix. Using this device, nasopharyngeal swab samples from COVID-19-infected individuals showed positive results at a reaction time of 35 min at 65 °C. This integrated device may be adapted to detect other RNA viruses of interest rapidly.


Assuntos
COVID-19 , Dispositivos Lab-On-A-Chip , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , Humanos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular , Limite de Detecção , RNA Viral/análise
2.
Epilepsy Res ; 186: 106994, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35973309

RESUMO

OBJECTIVE: To assess the effects of synaptic vesicle protein 2A (SV2A) modulators brivaracetam and levetiracetam on amygdala kindling epileptogenesis in Tg2576 mice, a model of Alzheimer's disease which exhibits sensitivity to seizures. METHODS: First, aged Tg2576 mice (13-25 months; n = 17) were treated subcutaneously with either brivaracetam (10 mg/kg/day), levetiracetam (150 mg/kg/day) or vehicle via osmotic pumps for 28 days prior to, and during electrical amygdala kindling epileptogenesis. Next, we treated young (4-6 months; n = 24) Tg2576 mice with brivaracetam (10 mg/kg/day) or vehicle for 28 days and allowed one week's 'washout' before commencing kindling. Progression of seizure severity and duration were compared between treatment groups and wildtype mice (WT). RESULTS: In older Tg2576 mice, treatment with brivaracetam (p < 0.001) and levetiracetam (p < 0.05) before and during kindling significantly delayed the progression of seizure severity, compared to vehicle. Animals treated with brivaracetam required significantly more stimulations to reach the first class V (convulsive) seizure and had a lower mortality rate (p < 0.05) compared to those treated with vehicle. Young Tg2576 mice also exhibited increased susceptibility to kindling epileptogenesis compared to WT. Treatment with brivaracetam in younger animals only prior to kindling also delayed kindling acquisition compared to vehicle treatment, increasing the number of stimulations required to experience class V seizures (p < 0.05). SIGNIFICANCE: Brivaracetam treatment displayed marked anti-epileptogenic effects in both aged and young Tg2576 mice, including when treatment is ceased prior to initiating kindling. Targeting SV2A might represent a strategy for prevention of epilepsy in patients with Alzheimer's disease.


Assuntos
Doença de Alzheimer , Excitação Neurológica , Doença de Alzheimer/tratamento farmacológico , Animais , Anticonvulsivantes/farmacologia , Anticonvulsivantes/uso terapêutico , Modelos Animais de Doenças , Levetiracetam/farmacologia , Levetiracetam/uso terapêutico , Camundongos , Convulsões/metabolismo , Vesículas Sinápticas/metabolismo
3.
Biosens Bioelectron ; 211: 114410, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35617799

RESUMO

Acute stroke is the third leading cause of mortality and disability worldwide. Administration of appropriate therapy for acute stroke is critically dependent on timely classification into either ischemic or hemorrhagic subtypes, which have divergent treatment pathways. The current classification method is based on neuroimaging, which generally requires the transport of the patient to a hospital-based facility unless a mobile stroke unit is available. Plasma glial fibrillary acidic protein (GFAP) level has been identified as a useful blood-based biomarker to differentiate stroke subtypes. However, its conventional immunoassay methods are laboratory-based and time-consuming. Novel approaches for rapid stroke classification near the patients are urgently needed. Here, we report the development and testing of a microfluidic-based magnetoimpedance biosensor platform for measuring GFAP levels. The platform consists of a microfluidic chip for GFAP extraction from a blood sample and a magnetoimpedance (MI) biosensor that employs Dynabeads as a magnetic label to capture the GFAP molecules. We demonstrated the detection of recombinant GFAP protein in phosphate-buffered saline (PBS) and in mouse blood samples (detection limit 0.01 ng/mL) and of physiological GFAP in blood and plasma samples (detection limit 1.0 ng/mL) obtained from acute stroke patients. This detection level is within the range of cut-off levels required for clinical stroke subtype differentiation. This platform has the potential to be incorporated into a small device with further development to assist in the classification of acute stroke patients and clinical decision-making at the point-of-care.


Assuntos
Técnicas Biossensoriais , Isquemia Encefálica , Acidente Vascular Cerebral , Animais , Biomarcadores , Isquemia Encefálica/diagnóstico , Hemorragia Cerebral/diagnóstico , Hemorragia Cerebral/terapia , Proteína Glial Fibrilar Ácida , Humanos , Camundongos , Microfluídica , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia
4.
Biosensors (Basel) ; 12(2)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35200368

RESUMO

The magnetic beads detection-based immunoassay, also called magneto-immunoassay, has potential applications in point-of-care testing (POCT) due to its unique advantage of minimal background interference from the biological sample and associated reagents. While magnetic field detection technologies are well established for numerous applications in the military, as well as in geology, archaeology, mining, spacecraft, and mobile phones, adaptation into magneto-immunoassay is yet to be explored. The magnetic field biosensors under development tend to be multilayered and require an expensive fabrication process. A low-cost and affordable biosensing platform is required for an effective point-of-care diagnosis in a resource-limited environment. Therefore, we evaluated a single-layered magnetic biosensor in this study to overcome this limitation. The shape-induced magnetic anisotropy-based planar hall effect sensor was recently developed to detect a low-level magnetic field, but was not explored for medical application. In this study, the elliptical-shaped planar hall effect (EPHE) sensor was designed, fabricated, characterized, and optimized for the magneto-immunoassay, specifically. Nine sensor variants were designed and fabricated. A customized measurement setup incorporating a lock-in amplifier was used to quantify 4.5 µm magnetic beads in a droplet. The result indicated that the single-domain behaviour of the magnetic film and larger sensing area with a thinner magnetic film had the highest sensitivity. The developed sensor was tested with a range of magnetic bead concentrations, demonstrating a limit of detection of 200 beads/µL. The sensor performance encourages employing magneto-immunoassay towards developing a low-cost POCT device in the future.


Assuntos
Técnicas Biossensoriais , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Imunoensaio/instrumentação , Separação Imunomagnética , Magnetismo
5.
Sci Rep ; 11(1): 22493, 2021 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-34795308

RESUMO

The COVID-19 pandemic caused by SARS-CoV-2 has infected millions worldwide, therefore there is an urgent need to increase our diagnostic capacity to identify infected cases. Although RT-qPCR remains the gold standard for SARS-CoV-2 detection, this method requires specialised equipment in a diagnostic laboratory and has a long turn-around time to process the samples. To address this, several groups have recently reported the development of loop-mediated isothermal amplification (LAMP) as a simple, low cost and rapid method for SARS-CoV-2 detection. Herein we present a comparative analysis of three LAMP-based assays that target different regions of the SARS-CoV-2: ORF1ab RdRP, ORF1ab nsp3 and Gene N. We perform a detailed assessment of their sensitivity, kinetics and false positive rates for SARS-CoV-2 diagnostics in LAMP or RT-LAMP reactions, using colorimetric or fluorescent detection. Our results independently validate that all three assays can detect SARS-CoV-2 in 30 min, with robust accuracy at detecting as little as 1000 RNA copies and the results can be visualised simply by color changes. Incorporation of RT-LAMP with fluorescent detection further increases the detection sensitivity to as little as 100 RNA copies. We also note the shortcomings of some LAMP-based assays, including variable results with shorter reaction time or lower load of SARS-CoV-2, and false positive results in some experimental conditions and clinical saliva samples. Overall for RT-LAMP detection, the ORF1ab RdRP and ORF1ab nsp3 assays have faster kinetics for detection but varying degrees of false positives detection, whereas the Gene N assay exhibits no false positives in 30 min reaction time, which highlights the importance of optimal primer design to minimise false-positives in RT-LAMP. This study provides validation of the performance of LAMP-based assays as a rapid, highly sensitive detection method for SARS-CoV-2, which have important implications in development of point-of-care diagnostics for SARS-CoV-2.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2/genética , Saliva/metabolismo , Adulto , COVID-19/diagnóstico , COVID-19/genética , COVID-19/metabolismo , Feminino , Humanos , Masculino , Saliva/virologia
6.
Sensors (Basel) ; 21(19)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34640832

RESUMO

Thin-film magneto-impedance (MI) biosensors have attracted significant attention due to their high sensitivity and easy miniaturization. However, further improvement is required to detect weak biomagnetic signals. Here, we report a meander thin-film biosensor preparation to investigate the fabrication parameters influencing the MI effect. Specifically, we hypothesized that an optimal film thickness and sensing area size ratio could be achieved to obtain a maximum MI ratio. A meander multilayer MI biosensor based on a NiFe/Cu/NiFe thin-film was designed and fabricated into 3-, 6-, and 9-turn models with film thicknesses of 3 µm and 6 µm. The 9-turn biosensor resembled the largest sensing area, while the 3- and 6-turn biosensors were designed with identical sensing areas. The results indicated that the NiFe film thickness of 6 µm with a sensing area size of 14.4 mm2 resembling a 9-turn MI biosensor is the optimal ratio yielding the maximum MI ratio of 238%, which is 70% larger than the 3- and 6-turn structures. The 3- and 6-turn MI biosensors exhibited similar characteristics where the MI ratio peaked at a similar value. Our results suggest that the MI ratio can be increased by increasing the sensing area size and film thickness rather than the number of turns. We showed that an optimal film thickness to sensing area size ratio is required to obtain a high MI ratio. Our findings will be useful for designing highly sensitive MI biosensors capable of detecting low biomagnetic signals.


Assuntos
Técnicas Biossensoriais , Impedância Elétrica
7.
Sci Rep ; 11(1): 15176, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34312441

RESUMO

There is currently a high level of demand for rapid COVID-19 tests, that can detect the onset of the disease at point of care settings. We have developed an ultra-portable, self-contained, point-of-care nucleic acid amplification test for diagnosis of active COVID-19 infection, based on the principle of loop mediated isothermal amplification (LAMP). The LAMP assay is 100% sensitive and specific to detect a minimum of 300 RNA copies/reaction of SARS-CoV-2. All of the required sample transportation, lysing and amplification steps are performed in a standalone disposable cartridge, which is controlled by a battery operated, pocket size (6x9x4cm3) unit. The test is easy to operate and does not require skilled personnel. The total time from sample to answer is approximately 35 min; a colorimetric readout indicates positive or negative results. This portable diagnostic platform has significant potential for rapid and effective testing in community settings. This will accelerate clinical decision making, in terms of effective triage and timely therapeutic and infection control interventions.


Assuntos
Teste de Ácido Nucleico para COVID-19/instrumentação , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Testes Imediatos , RNA Viral/genética , SARS-CoV-2/genética , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/economia , Desenho de Equipamento , Humanos , Técnicas de Diagnóstico Molecular/economia , Técnicas de Amplificação de Ácido Nucleico/economia , Testes Imediatos/economia , RNA Viral/análise , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Fatores de Tempo
8.
Sensors (Basel) ; 21(10)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068416

RESUMO

HLA-B*15:02 screening before administering carbamazepine is recommended to prevent life-threatening hypersensitivity. However, the unavailability of a point-of-care device impedes this screening process. Our research group previously developed a two-step HLA-B*15:02 detection technique utilizing loop-mediated isothermal amplification (LAMP) on the tube, which requires two-stage device development to translate into a portable platform. Here, we report a heater-integrated lab-on-a-chip device for the LAMP amplification, which can rapidly detect HLA-B alleles colorimetrically. A gold-patterned micro-sized heater was integrated into a 3D-printed chip, allowing microfluidic pumping, valving, and incubation. The performance of the chip was tested with color dye. Then LAMP assay was conducted with human genomic DNA samples of known HLA-B genotypes in the LAMP-chip parallel with the tube assay. The LAMP-on-chip results showed a complete match with the LAMP-on-tube assay, demonstrating the detection system's concurrence.


Assuntos
Hipersensibilidade a Drogas , Antígenos HLA-B , Dispositivos Lab-On-A-Chip , Alelos , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico
9.
J Stroke Cerebrovasc Dis ; 29(8): 104901, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32439350

RESUMO

OBJECTIVE: Polymorphisms in the CYP2C9 gene may be associated with adverse vascular events following endovascular procedures independent of antiplatelet therapy. We aimed to investigate the impact of CYP2C9 loss-of-function polymorphisms on adverse vascular events following neurointervention. PATIENTS AND METHODS: Consecutive patients undergoing neurointervention were prospectively recruited between 2010 and 2016. Patients were genotyped for the CYP2C9*2 and *3 loss-of-function polymorphisms. On the basis of possible genetic influence on antiplatelet response, ex vivo clopidogrel response was measured using the VerifyNow® P2Y12 Assay. The primary endpoint was the 90-day incidence of adverse vascular events including ischemic stroke. RESULTS: A total of 229 patients were included. The median age was 57 years (IQR: 49-64), and 158 (69.00%) were female. Eighty-one (35.37%) patients carried at least one CYP2C9 loss-of-function (LOF) allele. After adjustment for stroke risk factors, the 90-day incidence of ischemic stroke was significantly lower in the LOF group compared to the wild type group (1.23% vs 10.14%; ORadj = 0.16, 95% CI: 0.03-0.91; p = 0.04). CONCLUSIONS: Our results suggest protection against ischemic stroke in carriers of CYP2C9*2 or *3 polymorphisms undergoing neurointervention. Our findings warrant further studies to investigate the mechanisms by which CYP2C9 may influence the risk of ischemic stroke.


Assuntos
Isquemia Encefálica/genética , Isquemia Encefálica/prevenção & controle , Transtornos Cerebrovasculares/terapia , Citocromo P-450 CYP2C9/genética , Procedimentos Endovasculares/efeitos adversos , Variantes Farmacogenômicos , Polimorfismo de Nucleotídeo Único , Acidente Vascular Cerebral/genética , Acidente Vascular Cerebral/prevenção & controle , Idoso , Isquemia Encefálica/diagnóstico , Clopidogrel/farmacocinética , Citocromo P-450 CYP2C9/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Inibidores da Agregação Plaquetária/farmacocinética , Estudos Prospectivos , Fatores de Proteção , Queensland , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Vitória
10.
Sci Rep ; 9(1): 17495, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31767887

RESUMO

Malaria elimination is a global public health priority. To fulfil the demands of elimination diagnostics, we have developed an interdigitated electrode sensor platform targeting the Plasmodium falciparum Histidine Rich Protein 2 (PfHRP2) protein in saliva samples. A protocol for frequency-specific PfHRP2 detection in phosphate buffered saline was developed, yielding a sensitivity of 2.5 pg/mL based on change in impedance magnitude of the sensor. This protocol was adapted and optimized for use in saliva with a sensitivity of 25 pg/mL based on change in resistance. Further validation demonstrated detection in saliva spiked with PfHRP2 from clinical isolates in 8 of 11 samples. With a turnaround time of ~2 hours, the label-free platform based on impedance sensors has the potential for miniaturization into a point-of-care diagnostic device for malaria elimination.


Assuntos
Antígenos de Protozoários/análise , Malária Falciparum/diagnóstico , Plasmodium falciparum/metabolismo , Proteínas de Protozoários/análise , Saliva/parasitologia , Técnicas Biossensoriais/instrumentação , Testes Diagnósticos de Rotina , Impedância Elétrica , Humanos , Miniaturização , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
11.
Sensors (Basel) ; 19(16)2019 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-31416185

RESUMO

Pre-treatment screening of individuals for human leukocyte antigens (HLA) HLA-B*57:01 is recommended for the prevention of life-threatening hypersensitivity reactions to abacavir, a drug widely prescribed for HIV treatment. However, the implementation of screening in clinical practice is hindered by the slow turnaround time and high cost of conventional HLA genotyping methods. We have developed a biosensor platform using interdigitated electrode (IDE) functionalized with a monoclonal antibody to detect cells expressing HLA-B*57:01. This platform was evaluated using cell lines and peripheral blood mononuclear cells expressing different HLA-B alleles. The functionalized IDE sensor was able to specifically capture HLA-B*57:01 cells, resulting in a significant change in the impedance magnitude in 20 min. This IDE platform has the potential to be further developed to enable point-of-care HLA-B*57:01 screening.


Assuntos
Técnicas Biossensoriais/métodos , Didesoxinucleosídeos/efeitos adversos , Hipersensibilidade a Drogas/prevenção & controle , Antígenos HLA-B/análise , Leucócitos Mononucleares/metabolismo , Alelos , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Didesoxinucleosídeos/uso terapêutico , Hipersensibilidade a Drogas/etiologia , Técnicas Eletroquímicas , Eletrodos , Infecções por HIV/tratamento farmacológico , Antígenos HLA-B/genética , Antígenos HLA-B/imunologia , Humanos
12.
Sensors (Basel) ; 19(11)2019 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-31146340

RESUMO

Elimination of malaria is a global health priority. Detecting an asymptomatic carrier of Plasmodium parasites to receive treatment is an important step in achieving this goal. Current available tools for detection of malaria parasites are either expensive, lacking in sensitivity for asymptomatic carriers, or low in throughput. We investigated the sensitivity of an impedimetric biosensor targeting the malaria biomarker Plasmodium lactate dehydrogenase (pLDH). Following optimization of the detection protocol, sensor performance was tested using phosphate-buffered saline (PBS), and then saliva samples spiked with pLDH at various concentrations. The presence of pLDH was determined by analyzing the sensor electrical properties before and after sample application. Through comparing percentage changes in impedance magnitude, the sensors distinguished pLDH-spiked PBS from non-spiked PBS at concentrations as low as 250 pg/mL (p = 0.0008). Percentage changes in impedance magnitude from saliva spiked with 2.5 ng/mL pLDH trended higher than those from non-spiked saliva. These results suggest that these biosensors have the potential to detect concentrations of pLDH up to two logs lower than currently available best-practice diagnostic tools. Successful optimization of this sensor platform would enable more efficient diagnosis of asymptomatic carriers, who can be targeted for treatment, contributing to the elimination of malaria.


Assuntos
Anticorpos Antiprotozoários/imunologia , Técnicas Biossensoriais , Impedância Elétrica , L-Lactato Desidrogenase/análise , Plasmodium/enzimologia , Eletrodos , Estudos de Viabilidade , Humanos , Plasmodium/imunologia , Saliva/enzimologia
13.
Biosens Bioelectron ; 111: 174-183, 2018 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-29673585

RESUMO

Prevention of life threatening hypersensitivity reactions to carbamazepine is possible through pre-treatment screening of the associated HLA-B*15:02 risk allele. However, clinical implementation of screening is hindered by the high cost and slow turnaround of conventional HLA typing methods. We have developed an interdigitated electrode (IDE) biosensor platform utilizing loop mediated isothermal amplification (LAMP) that can rapidly detect the HLA-B*15:02 allele. DNA amplification is followed by solid-phase hybridization of LAMP amplicons to a DNA probe immobilized on the IDE sensor surface, resulting in a change in sensor impedance. The testing platform does not require DNA extraction or post-amplification staining, achieving sample-to-answer in 1 h and 20 min. The platform was tested on 27 whole blood samples (14 HLA-B*15:02 positive and 13 negative) with sensitivity of 92.9% and specificity of 84.6% when applying a cutoff of impedance change. Based on these characters the LAMP-IDE platform has potential to be further developed into point-of-care use to help overcome barriers in HLA-B*15:02 screening.


Assuntos
Técnicas Biossensoriais/instrumentação , Hipersensibilidade a Drogas/genética , Técnicas de Genotipagem/instrumentação , Antígenos HLA-B/genética , Alelos , Sequência de Bases , Sondas de DNA/genética , Hipersensibilidade a Drogas/sangue , Eletricidade , Eletrodos , Desenho de Equipamento , Genótipo , Antígenos HLA-B/sangue , Humanos , Ácidos Nucleicos Imobilizados/genética , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito
14.
Epilepsia ; 58(9): e136-e141, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28710841

RESUMO

The biologic processes underlying epileptogenesis following a brain insult are not fully understood, but several lines of evidence suggest that hyperphosphorylation of tau may be an important factor in these processes. To provide further insight into the causal relationship between tau and epileptogenesis, this study applied amygdala kindling to rTg4510 mice that, concurrent with other pathologies, overexpress phosphorylated tau, tau knockout mice, or their respective wild-type controls. Mice were electrically stimulated twice daily, 5 days per week for 3 weeks. Electroencephalography was recorded to measure the primary afterdischarge duration, and the behavioral progression of kindling-induced seizures was assessed. rTg4510 mice (n = 10) had increased primary afterdischarge durations (p < 0.001), and significantly more rapid progression of kindling (p < 0.001), compared with wild-type mice (n = 10). Tau knockout mice (n = 7), however, did not differ from their wild-type counterparts (n = 8) on any of the seizure outcomes. These results suggest that Tg4510 mice are more vulnerable to epileptogenesis, but that the presence of tau itself is not necessary for kindling epileptogenesis to occur.


Assuntos
Excitação Neurológica/metabolismo , Proteínas tau/fisiologia , Tonsila do Cerebelo/metabolismo , Animais , Feminino , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Fosforilação , Proteínas tau/metabolismo
15.
Biosensors (Basel) ; 7(2)2017 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-28475117

RESUMO

The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems.


Assuntos
Técnicas Biossensoriais/métodos , Neoplasias Colorretais/sangue , Detecção Precoce de Câncer , Hemoglobinas/isolamento & purificação , Neoplasias Colorretais/diagnóstico , Fezes/química , Hemoglobinas/química , Humanos , Sangue Oculto
16.
Pharmacogenomics ; 16(12): 1399-409, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26229012

RESUMO

Point-of-care molecular diagnostic devices are a rapidly expanding market. A variety of technologies are being developed for DNA detection and amplification, mostly aiming to detect pathogens. Of the two devices for detection of human genetic variations, both focus on CYP2C19 and have obtained regulatory approval. Most other devices have not obtained US FDA approval and are still undergoing clinical trials. Most, if not all, devices in development require equipment to which disposable test cartridges are placed. Thus, they may not fulfill FDA's definition of being 'simple'. There is a clear need to develop completely disposable devices that do not require equipment maintenance, and to detect other genetic variants predictive of disease susceptibility and drug response.


Assuntos
Técnicas de Diagnóstico Molecular/instrumentação , Citocromo P-450 CYP2C19/genética , DNA/genética , Variação Genética/genética , Humanos , Técnicas de Diagnóstico Molecular/métodos , Patologia Molecular/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Estados Unidos , United States Food and Drug Administration
17.
Epilepsia ; 56(6): e73-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25879152

RESUMO

People with Alzheimer's disease (AD) are up to 10 times more likely to develop epilepsy than the age-matched general population. However, given that only a proportion of patients with AD develop epilepsy, it is likely that additional factors may be required for the epilepsy to emerge. This study aimed to better understand the relationship between AD pathology and seizure susceptibility. It also aimed to investigate a "two-hit" hypothesis for seizure susceptibility through amygdala kindling of rodent AD models. Aged AD mice (Tg2576 model) and wild-type (WT) mice underwent electrical amygdala kindling. Compared with WT mice, Tg2576 mice had significantly lower afterdischarge threshold. Significantly fewer stimulations were required for the Tg2576 mice to reach the first class V seizure. Higher death rate was observed with Tg2576 mice in the kindling group. Both sham and kindled Tg2576 animals had increased levels of sprouting in the supragranular layer of the dentate gyrus compared with the WT counterparts. These findings support the "two-hit" hypothesis and represent a potentially novel research model to help better understand the relationship between AD pathology and epilepsy.


Assuntos
Doença de Alzheimer/complicações , Doença de Alzheimer/patologia , Tonsila do Cerebelo/patologia , Epilepsia/complicações , Epilepsia/mortalidade , Excitação Neurológica/fisiologia , Doença de Alzheimer/genética , Precursor de Proteína beta-Amiloide/genética , Animais , Modelos Animais de Doenças , Suscetibilidade a Doenças , Estimulação Elétrica/efeitos adversos , Epilepsia/etiologia , Feminino , Humanos , Camundongos , Camundongos Transgênicos , Mutação/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...