Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Belg Soc Radiol ; 108(1): 81, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39308749

RESUMO

Teaching point: Perivascular spaces, also known as Virchow-Robin spaces, are fluid-filled spaces that surround the vessel walls from the subarachnoid space through the brain parenchyma.

2.
Neuroradiology ; 65(7): 1133-1141, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995375

RESUMO

PURPOSE: Sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE). Our study aims to (i) evaluate the diagnostic accuracy of SPACE compared to its use in combination with VIBE, (ii) investigate the effect of radiologist's experience in the sequence's performance, and (iii) analyze causes of discordants results. METHODS: Four hundred seventy-three 3T MRI scans were retrospectively analyzed following a monocentric study design. Two studies were formed: one including SPACE alone and one combining both sequences (SPACE + VIBE, the reference). An experienced neuroradiologist and a radiology trainee independently reviewed the images of each study and reported the number of brain metastases. The sensitivity (Se) and specificity (Sp) of SPACE compared to SPACE + VIBE in metastases detection were reported. Diagnostic accuracy of SPACE compared to SPACE + VIBE was assessed by using McNemar's test. Significance was set at p < 0.05. Cohen's kappa was used for inter-method and inter-observer variability. RESULTS: No significant difference was found between the two methods, with SPACE having a Se > 93% and a Sp > 87%. No effect of readers' experience was disclosed. CONCLUSION: Independently of radiologist's experience, SPACE alone is robust enough to replace SPACE + VIBE for brain metastases detection.


Assuntos
Neoplasias Encefálicas , Imageamento Tridimensional , Humanos , Estudos Retrospectivos , Fluxo de Trabalho , Imageamento Tridimensional/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
3.
J Belg Soc Radiol ; 105(1): 51, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34622139

RESUMO

Teaching point: MRI allows to assess deformity and viability of the tibia in Blount disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...