RESUMO
Laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF-MS) analysis is harnessed to investigate the chemical structure and photochemical properties of two distinct graphene oxide (GO) derivatives simultaneously. The GO derivatives are synthesized with modified Brodie's method (BGO) and Hummers' method (HGO) and characterized by LDI-TOF-MS as well as conventional tools. A series of LDI-TOF-MS analyses reveal that BGO provides higher laser energy absorption, photochemical stability, and photothermal conversion property than HGO based on their fragmentation patterns and laser desorption/ionization behavior of a thermometer molecule. Based on these characteristics, BGO exhibits higher efficiency in the LDI-TOF-MS analysis of various small molecules and synthetic polymers than HGO. These different photochemical properties of BGO are derived from its large sp2 carbon domains compared to HGO. Based on our findings, the analytical potential of LDI-TOF-MS for GO derivatives is clearly demonstrated, which can be an efficient and unique characterization tool to explore both chemical structures and photochemical properties of various carbon materials.
RESUMO
Highly stable conducting fibers have attracted significant attention in electronic textile (e-textile) applications. Here, we fabricate highly conducting poly(vinyl alcohol) (PVA) nanocomposite fibers with high thermal and chemical stability based on silver nanobelt (AgNB)/multiwalled carbon nanotube (MWCNT) hybrid materials as conducting fillers. At 20 vol % AgNB/MWCNT, the electrical conductivity of the fiber dramatically increased (â¼533 times) from 3 up to 1600 S/cm after thermal treatment at 300 °C for 5 min. Moreover, PVA/AgNB/MWCNT fiber resists the harsh conditions of good solvents for PVA as well as high temperatures over the melting point of PVA, whereas pure PVA fiber is unstable in these environments. The significantly enhanced electrical conductivity and chemical stability can be realized through the post-thermal curing process, which is attributed to the coalescence between adjacent AgNBs and additional intensive cross-linking of PVA. These remarkable characteristics make our conducting fibers suitable for applications in e-textiles such as water leakage detectors and wearable heaters. In particular, heating behavior of e-textiles by Joule heating can accelerate the desorption of physically trapped moisture from the fiber surface, resulting in the fully reversible operation of water leakage monitoring. This smart e-textile sensor based on highly stable and conductive composite fibers will pave the way for diverse e-textile applications.
RESUMO
Soft electronic devices that are bendable and stretchable require stretchable electric or electronic components. Nanostructured conducting materials or soft conducting polymers are one of the most promising fillers to achieve high performance and durability. Here, we report silver nanoparticles (AgNPs) embedded with single-walled carbon nanotubes (SWCNTs) synthesized in aqueous solutions at room temperature, using NaBH4 as a reducing agent in the presence of highly oxidized SWCNTs as efficient nucleation agents. Elastic composite films composed of the AgNPs-embedded SWCNTs, Ag flake, and polydimethylsiloxane are irradiated with radiation from a Xenon flash lamp within a time interval of one second for efficient sintering of conductive fillers. Under high irradiation energy, the stretchable electrodes are created with a maximum conductivity of 4,907 S cm-1 and a highly stretchable stability of over 10,000 cycles under a 20% strain. Moreover, under a low irradiation energy, strain sensors with a gauge factor of 76 under a 20% strain and 5.4 under a 5% strain are fabricated. For practical demonstration, the fabricated stretchable electrode and strain sensor are attached to a human finger for detecting the motions of the finger.
RESUMO
The thermal stability of solution-exfoliated graphene oxide (GO) in air is one of the most important physical properties influencing its potential applications. To date, the majority of the GO prepared by the KMnO4-based oxidation of graphite is thermally unstable in air due to the presence of highly oxidative functional groups, such as carboxyl and lactol groups that possess defective basal plane structures. Here, we demonstrate that less defective and metal ion-free GO nanosheets including those with a high oxidation level can remain very stable even above 300 °C under ambient conditions. These GO nanosheets were produced by the exfoliation of graphite oxide fabricated by the modified Brodie method in NH4OH solution, effectively excluding metal ions that can promote the thermal decomposition of GO in air at elevated temperatures. The deoxygenation of ammonia-assisted GO (AGO) was initiated at temperatures above 200 °C, while GO exfoliated in the KOH solution (KGO) decomposed, even at 180 °C. Notably, AGO was exceptionally resistant at 400 °C, even at a very slow heating rate of 2 °C min-1. Conversely, KGO was significantly oxidized, even at 250 °C. The superior thermal stability of AGO is favorable for the fabrication of conductive surface graphene films and conductive fibers by low-temperature annealing.
RESUMO
The kainic acid-induced seizure mouse model is widely used in epilepsy research. In this study, we applied kainic acid to the subcutaneous injections of three different sources of DBA/2 mice to compare and evaluate the seizure response. The three mouse sources consisted of DBA/2Kor1 (Korea FDA source), DBA/2A (USA source), and DBA/2 (Japan source), and were purchased from different vendors. To compare the responses of DBA/2 mice to kainic acid injections, we examined the survival rate, seizure phenotype scoring, and behavioral changes. We also evaluated brain lesions using histopathological analysis. Following the administration of kainic acid, almost half of the cohort survived, and the seizure phenotype displayed a moderate level of sensitivity (2 ~ 4 out of 6). In the histopathologic analysis, there was no change in morphological features, and levels of glial fibrillary acidic protein (GFAP) and ionized calcium binding adaptor molecule 1 (Iba-1) increased in the kainic acid-treated groups. However, there was no difference in the neuronal nuclei (NeuN) expression level. All the data showed that the responses in the kainic acid-treated group were similar across the three strains. In conclusion, our results suggest that the three sources of DBA/2 mice (DBA/2Kor1, DBA/2A, and DBA/2B) have similar pathological responses to kainic acid-induced seizures.
RESUMO
Compared with traditional metal-oxide lithium-ion battery (LIB) cathodes, nanocarbon-based cathode materials have received much attention for potential application in LIBs because of their superior power density and long-term cyclability. However, their lithium-ion storage capacity needs further improvement for practical applications, and the trade-off between capacity and conductivity, when oxygen functional groups as lithium-ion storage sites are introduced to the nanocarbon materials, needs to be addressed. Here, we report a sequential oxidation-reduction process for the synthesis of single-walled carbon nanotubes (SWCNTs) for LIB cathodes with fast charging, long-term cyclability, and high gravimetric capacity. A LIB cathode based on highly exfoliated (dbundle < 10 nm) and oxygen-functionalized single-walled carbon nanotubes is obtained via the modified Brodie's method using fuming nitric acid and a mild oxidant (B-SWCNTs). Post treatment including horn sonication and hydrogen thermal reduction developed surface defects and removed the unnecessary C-O groups, resulting in an increase in the Li-ion storage capacity. The B-SWCNTs exhibit a high reversible gravimetric capacity of 344 mA h g-1 at 0.1 A g-1 without noticeable capacity fading after 1000 cycles. Furthermore, it delivers a high gravimetric energy density of 797 W h kgelectrode-1 at a low gravimetric power density of 300 W kgelectrode-1 and retains its high gravimetric energy density of â¼100 W h kgelectrode-1 at a high gravimetric power of 105 W kgelectrode-1. These results suggest that the highly exfoliated, oxygen-functionalized single-walled carbon nanotubes can be applied to LIBs designed for high-rate operations and long cycling.
RESUMO
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.
RESUMO
This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, Avertin®) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak CO2 (ETCO2), mean arterial blood pressure, heart rate, oxygen saturation (SpO2), body temperature, pH, PCO2, and PO2 of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, SPO2, arterial blood PCO2, and PO2, which decreased after TBE anesthesia, or in heart rate and ETCO2, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.
RESUMO
Animal model, as an indispensable tool for scientific purposes of biomedical researches and clinical application, is a commonly used in various researches. Regarding to this, it is necessary to establish the metabolic phenotype of animal model to minimize spurious interpretations and ensure a level of accuracy and reliability adequate for experimental research. However, the metabolic phenotype-related analysis within rodent strains derived from different source is nonexistent, especially in C57BL/6Korl mice and Korl:ICR mice (a domestic mouse strain). To compare the physiological and metabolic phenotypes over a period of time, we utilized the C57BL/6 mice (C57BL/6Korl, A:C57BL/6, and B:C57BL/6) and ICR mice (Korl:ICR, A:ICR, and B:ICR) derived from three different sources. Our data showed that average body weight, body temperature, food intake, and water consumption have a similar tendency among the C57BL/6 and ICR groups, except for the higher body weight of C57BL/6Korl mice over a period of time. Moreover, some significant differences was observed in adipose tissue mass and adipocyte size among the groups, with a higher tendency of C57BL/6Korl mice and Korl:ICR mice. Most importantly, resting metabolic rate (RMR) serves as an approximation of the metabolic phenotype showed no significant difference among the groups of C57BL/6 mice and ICR mice, except for the lower oxygen uptake of C57BL/6Korl mice compare to the A:C57BL/6 mice. Taken together, our data suggest that C57BL/6 mice and ICR mice derived from three different sources have an overall similar feature of physiological and metabolic phenotypes.
RESUMO
C57BL/6N is the most widely used inbred mouse strain applied in a wide variety of research areas including cancer, cardiovascular biology, developmental biology, diabetes and obesity, genetics, immunology, neurobiology, and sensorineural research. To compare the fertilization rates of C57BL/6NKorl mice with two commercial C57BL/6N stocks, differences in reproductive organ structures, sperm and egg numbers, fertilization rates, and embryo development rates among C57BL/6NKorl (Korea FDA source), C57BL/6NA (USA source), and C57BL/6NB (Japan source) mice were determined. Among the stocks, no significant differences were detected in organ weight and histological structure of male and female reproductive organs, although body weight was higher in C57BL/6NKorl mice than that in the other groups. The concentration and morphology of sperm and eggs in C57BL/6NKorl mice were similar to those of C57BL/6NA and C57BL/6NB mice. Furthermore, the three stocks had similar in vitro fertilization and embryo development rates, although these rates tended to be higher in C57BL/6NB mice. Pup body weight was higher in C57BL/6NKorl and C57BL/6NB mice than that in C57BL/6NA mice. The results of the present study suggest that C57BL/6NKorl, C57BL/6NA, and C57BL/6NB mice obtained from three different sources have similar fertilization and embryo development rates, although there were slight differences in the magnitude of their responses rates.
RESUMO
Most synthetic processes of metallic nanostructures were assisted by organic/inorganic or polymeric materials to control their shapes to one-dimension or two-dimension. However, these additives have to be removed after synthesis of metal nanostructures for applications. Here we report a straightforward method for the low-temperature and additive-free synthesis of nanobelt-like silver nanostructures templated by nanocarbon (NC) materials via bio-inspired shape control by introducing supramolecular 2-ureido-4[1H]pyrimidinone (UPy) groups into the NC surface. The growth of the Ag nanobelt structure was found to be induced by these UPy groups through observation of the selective formation of Ag nanobelts on UPy-modified carbon nanotubes and graphene surfaces. The synthesized NC/Ag nanobelt hybrid materials were subsequently used to fabricate the highly conductive fibres (>1000S/cm) that can function as a conformable electrode and highly tolerant strain sensor, as well as a highly conductive and robust paper (>10000S/cm after thermal treatment).
RESUMO
Directly printed superhydrophobic surfaces containing conducting nanomaterials can be used for a wide range of applications in terms of nonwetting, anisotropic wetting, and electrical conductivity. Here, we demonstrated that direct-printable and flexible superhydrophobic surfaces were fabricated on flexible substrates via with an ultrafacile and scalable screen printing with carbon nanotube (CNT)-based conducting pastes. A polydimethylsiloxane (PDMS)-polyethylene glycol (PEG) copolymer was used as an additive for conducting pastes to realize the printability of the conducting paste as well as the hydrophobicity of the printed surface. The screen-printed conducting surfaces showed a high water contact angle (WCA) (>150°) and low contact angle hysteresis (WCA < 5°) at 25 wt % PDMS-PEG copolymer in the paste, and they have an electrical conductivity of over 1000 S m-1. Patterned superhydrophobic surfaces also showed sticky superhydrophobic characteristics and were used to transport water droplets. Moreover, fabricated films on metal meshes were used for an oil/water separation filter, and liquid evaporation behavior was investigated on the superhydrophobic and conductive thin-film heaters by applying direct current voltage to the film.
RESUMO
[This corrects the article on p. 124 in vol. 33, PMID: 28747978.].
RESUMO
[This corrects the article on p. 132 in vol. 33, PMID: 28747979.].
RESUMO
[This corrects the article on p. 140 in vol. 33, PMID: 28747980.].
RESUMO
[This corrects the article on p. 157 in vol. 33, PMID: 28747982.].
RESUMO
[This corrects the article on p. 165 in vol. 33, PMID: 28747983.].
RESUMO
[This corrects the article on p. 171 in vol. 33, PMID: 28747984.].
RESUMO
BACKGROUND: Most surgeons favor the pledgeted suture technique for heart valve replacements because they believe it decreases the risk of paravalvular leak (PVL). We hypothesized that the use of nonpledgeted rather than pledgeted sutures during mitral valve replacement (MVR) may decrease the incidence of prosthetic valve endocarditis (PVE) and risk of a major PVL. METHODS: We analyzed 263 patients, divided into 175 patients who underwent MVR with nonpledgeted sutures from January 2003 to December 2013 and 88 patients who underwent MVR with pledgeted sutures from January 1995 to December 2001. We compared the occurrence of PVL and PVE between these groups. RESULTS: In patients who underwent MVR with or without tricuspid valve surgery and/or a Maze operation, PVL occurred in 1.1% of the pledgeted group and 2.9% of the nonpledgeted group. The incidence of PVE was 2.9% in the nonpledgeted group and 1.1% in the pledgeted group. No differences were statistically significant. CONCLUSION: We suggest that a nonpledgeted suture technique can be an alternative to the traditional use of pledgeted sutures in most patients who undergo MVR, with no significant difference in the incidence of PVL.