Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Trials ; 25(1): 386, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886851

RESUMO

BACKGROUND: Liver disease is the third leading cause of premature death in the UK. Transplantation is the only successful treatment for end-stage liver disease but is limited by a shortage of suitable donor organs. As a result, up to 20% of patients on liver transplant waiting lists die before receiving a transplant. A third of donated livers are not suitable for transplant, often due to steatosis. Hepatic steatosis, which affects 33% of the UK population, is strongly associated with obesity, an increasing problem in the potential donor pool. We have recently tested defatting interventions during normothermic machine perfusion (NMP) in discarded steatotic human livers that were not transplanted. A combination of therapies including forskolin (NKH477) and L-carnitine to defat liver cells and lipoprotein apheresis filtration were investigated. These interventions resulted in functional improvement during perfusion and reduced the intrahepatocellular triglyceride (IHTG) content. We hypothesise that defatting during NMP will allow more steatotic livers to be transplanted with improved outcomes. METHODS: In the proposed multi-centre clinical trial, we will randomly assign 60 livers from donors with a high-risk of hepatic steatosis to either NMP alone or NMP with defatting interventions. We aim to test the safety and feasibility of the defatting intervention and will explore efficacy by comparing ex-situ and post-reperfusion liver function between the groups. The primary endpoint will be the proportion of livers that achieve predefined functional criteria during perfusion which indicate potential suitability for transplantation. These criteria reflect hepatic metabolism and injury and include lactate clearance, perfusate pH, glucose metabolism, bile composition, vascular flows and transaminase levels. Clinical secondary endpoints will include proportion of livers transplanted in the two arms, graft function; cell-free DNA (cfDNA) at follow-up visits; patient and graft survival; hospital and ITU stay; evidence of ischemia-reperfusion injury (IRI); non-anastomotic biliary strictures and recurrence of steatosis (determined on MRI at 6 months). DISCUSSION: This study explores ex-situ pharmacological optimisation of steatotic donor livers during NMP. If the intervention proves effective, it will allow the safe transplantation of livers that are currently very likely to be discarded, thereby reducing waiting list deaths. TRIAL REGISTRATION: ISRCTN ISRCTN14957538. Registered in October 2022.


Assuntos
Fígado Gorduroso , Transplante de Fígado , Perfusão , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Transplante de Fígado/métodos , Perfusão/métodos , Fígado Gorduroso/terapia , Doadores de Tecidos/provisão & distribuição , Fígado/patologia , Estudos Multicêntricos como Assunto , Preservação de Órgãos/métodos , Fatores de Tempo , Resultado do Tratamento
2.
Med Phys ; 51(2): 809-825, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37477551

RESUMO

BACKGROUND: There is increasing interest in using ultrasound for thermal ablation, histotripsy, and thermal or cavitational enhancement of drug delivery for the treatment of pancreatic cancer. Ultrasonic and thermal modelling conducted as part of the treatment planning process requires acoustic property values for all constituent tissues, but the literature contains no data for the human pancreas. PURPOSE: This study presents the first acoustic property measurements of human pancreatic samples and provides examples of how these properties impact a broad range of ultrasound therapies. METHODS: Data were collected on human pancreatic tissue samples at physiological temperature from 23 consented patients in cooperation with a hospital pathology laboratory. Propagation of ultrasound over the 2.1-4.5 MHz frequency range through samples of various thicknesses and pathologies was measured using a set of custom-built ultrasonic calipers, with the data processed to estimate sound speed and attenuation. The results were used in acoustic and thermal simulations to illustrate the impacts on extracorporeal ultrasound therapies for mild hyperthermia, thermal ablation, and histotripsy implemented with a CE-marked clinical system operating at 0.96 MHz. RESULTS: The mean sound speed and attenuation coefficient values for human samples were well below the range of values in the literature for non-human pancreata, while the human attenuation power law exponents were substantially higher. The simulated impacts on ultrasound mediated therapies for the pancreas indicated that when using the human data instead of the literature average, there was a 30% reduction in median temperature elevation in the treatment volume for mild hyperthermia and 43% smaller volume within a 60°C contour for thermal ablation, all driven by attenuation. By comparison, impacts on boiling and intrinsic threshold histotripsy were minor, with peak pressures changing by less than 15% (positive) and 1% (negative) as a consequence of the counteracting effects of attenuation and sound speed. CONCLUSION: This study provides the most complete set of speed of sound and attenuation data available for the human pancreas, and it reiterates the importance of acoustic material properties in the planning and conduct of ultrasound-mediated procedures, particularly thermal therapies.


Assuntos
Neoplasias Pancreáticas , Terapia por Ultrassom , Humanos , Som , Ultrassonografia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Pâncreas/diagnóstico por imagem
3.
Blood ; 143(8): 721-733, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38048591

RESUMO

ABSTRACT: The volume of oxygen drawn from systemic capillaries down a partial pressure gradient is determined by the oxygen content of red blood cells (RBCs) and their oxygen-unloading kinetics, although the latter is assumed to be rapid and, therefore, not a meaningful factor. Under this paradigm, oxygen transfer to tissues is perfusion-limited. Consequently, clinical treatments to optimize oxygen delivery aim at improving blood flow and arterial oxygen content, rather than RBC oxygen handling. Although the oxygen-carrying capacity of blood is increased with transfusion, studies have shown that stored blood undergoes kinetic attrition of oxygen release, which may compromise overall oxygen delivery to tissues by causing transport to become diffusion-limited. We sought evidence for diffusion-limited oxygen release in viable human kidneys, normothermically perfused with stored blood. In a cohort of kidneys that went on to be transplanted, renal respiration correlated inversely with the time-constant of oxygen unloading from RBCs used for perfusion. Furthermore, the renal respiratory rate did not correlate with arterial O2 delivery unless this factored the rate of oxygen-release from RBCs, as expected from diffusion-limited transport. To test for a rescue effect, perfusion of kidneys deemed unsuitable for transplantation was alternated between stored and rejuvenated RBCs of the same donation. This experiment controlled oxygen-unloading, without intervening ischemia, holding all non-RBC parameters constant. Rejuvenated oxygen-unloading kinetics improved the kidney's oxygen diffusion capacity and increased cortical oxygen partial pressure by 60%. Thus, oxygen delivery to tissues can become diffusion-limited during perfusion with stored blood, which has implications in scenarios, such as ex vivo organ perfusion, major hemorrhage, and pediatric transfusion. This trial was registered at www.clinicaltrials.gov as #ISRCTN13292277.


Assuntos
Eritrócitos , Oxigênio , Humanos , Criança , Rim
4.
Molecules ; 28(23)2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38067464

RESUMO

Ultrasound-mediated cavitation shows great promise for improving targeted drug delivery across a range of clinical applications. Cavitation nuclei-sound-sensitive constructs that enhance cavitation activity at lower pressures-have become a powerful adjuvant to ultrasound-based treatments, and more recently emerged as a drug delivery vehicle in their own right. The unique combination of physical, biological, and chemical effects that occur around these structures, as well as their varied compositions and morphologies, make cavitation nuclei an attractive platform for creating delivery systems tuned to particular therapeutics. In this review, we describe the structure and function of cavitation nuclei, approaches to their functionalization and customization, various clinical applications, progress toward real-world translation, and future directions for the field.


Assuntos
Sistemas de Liberação de Medicamentos , Microbolhas , Ultrassonografia
5.
BMC Cancer ; 23(1): 896, 2023 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-37741968

RESUMO

BACKGROUND: The dense stroma of pancreatic ductal adenocarcinomas is a major barrier to drug delivery. To increase the local drug diffusion gradient, high doses of chemotherapeutic agent doxorubicin can be released from thermally-sensitive liposomes (ThermoDox®) using ultrasound-mediated hyperthermia at the tumour target. PanDox is designed as a Phase 1 single centre study to investigate enhancing drug delivery to adult patients with non-operable pancreatic ductal adenocarcinomas. The study compares a single cycle of either conventional doxorubicin alone or ThermoDox® with focused ultrasound-induced hyperthermia for targeted drug release. METHODS: Adults with non-resectable pancreatic ductal adenocarcinoma are allocated to receive a single cycle of either doxorubicin alone (Arm A) or ThermoDox® with focused ultrasound-induced hyperthermia (Arm B), based on patient- and tumour-specific safety conditions. Participants in Arm B will undergo a general anaesthetic and pre-heating of the tumour by extra-corporal focused ultrasound (FUS). Rather than employing invasive thermometry, ultrasound parameters are derived from a patient-specific treatment planning model to reach the 41 °C target temperature for drug release. ThermoDox® is then concurrently infused with further ultrasound exposure. Tumour biopsies at the targeted site from all patients are analysed post-treatment using high performance liquid chromatography to quantify doxorubicin delivered to the tumour. The primary endpoint is defined as a statistically significant enhancement in concentration of total intra-tumoural doxorubicin, comparing samples from patients receiving liposomal drug with FUS to free drug alone. Participants are followed for 21 days post-treatment to assess secondary endpoints, including radiological assessment to measure changes in tumour activity by Positron Emission Tomography Response Criteria in Solid Tumours (PERCIST) criteria, adverse events and patient-reported symptoms. DISCUSSION: This early phase study builds on previous work targeting tumours in the liver to investigate whether enhancement of chemotherapy delivery using ultrasound-mediated hyperthermia can be translated to the stroma-dense environment of pancreatic ductal adenocarcinoma. If successful, it could herald a new approach towards managing these difficult-to-treat tumours. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04852367 . Registered 21st April 2022. EudraCT number: 2019-003950-10 (Registered 2019) Iras Project ID: 272253 (Registered 2019) Ethics Number: 20/EE/0284.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Policetídeos , Adulto , Humanos , Tomografia Computadorizada por Raios X , Doxorrubicina/uso terapêutico , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/tratamento farmacológico , Antraciclinas , Antibióticos Antineoplásicos/uso terapêutico , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/tratamento farmacológico , Ensaios Clínicos Fase I como Assunto , Neoplasias Pancreáticas
6.
Pharmaceutics ; 15(8)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37631324

RESUMO

The promotion of anti-tumour immune responses can be an effective route to the complete remission of primary and metastatic tumours in a small proportion of patients. Hence, researchers are currently investigating various methods to further characterise and enhance such responses to achieve a beneficial impact across a wider range of patients. Due to its non-invasive, non-ionising, and targetable nature, the application of ultrasound-mediated cavitation has proven to be a popular method to enhance the delivery and activity of immune checkpoint inhibitors. However, to optimise this approach, it is important to understand the biological and physical mechanisms by which cavitation may promote anti-tumour immune responses. Here, the published literature relating to the role that cavitation may play in modulating anti-tumour immunity is therefore assessed.

7.
Ann Surg ; 278(5): e912-e921, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37389552

RESUMO

OBJECTIVE: To compare conventional low-temperature storage of transplant donor livers [static cold storage (SCS)] with storage of the organs at physiological body temperature [normothermic machine perfusion (NMP)]. BACKGROUND: The high success rate of liver transplantation is constrained by the shortage of transplantable organs (eg, waiting list mortality >20% in many centers). NMP maintains the liver in a functioning state to improve preservation quality and enable testing of the organ before transplantation. This is of greatest potential value with organs from brain-dead donor organs (DBD) with risk factors (age and comorbidities), and those from donors declared dead by cardiovascular criteria (donation after circulatory death). METHODS: Three hundred eighty-three donor organs were randomized by 15 US liver transplant centers to undergo NMP (n = 192) or SCS (n = 191). Two hundred sixty-six donor livers proceeded to transplantation (NMP: n = 136; SCS: n = 130). The primary endpoint of the study was "early allograft dysfunction" (EAD), a marker of early posttransplant liver injury and function. RESULTS: The difference in the incidence of EAD did not achieve significance, with 20.6% (NMP) versus 23.7% (SCS). Using exploratory, "as-treated" rather than "intent-to-treat," subgroup analyses, there was a greater effect size in donation after circulatory death donor livers (22.8% NMP vs 44.6% SCS) and in organs in the highest risk quartile by donor risk (19.2% NMP vs 33.3% SCS). The incidence of acute cardiovascular decompensation at organ reperfusion, "postreperfusion syndrome," as a secondary outcome was reduced in the NMP arm (5.9% vs 14.6%). CONCLUSIONS: NMP did not lower EAD, perhaps related to the inclusion of lower-risk liver donors, as higher-risk donor livers seemed to benefit more. The technology is safe in standard organ recovery and seems to have the greatest benefit for marginal donors.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36112556

RESUMO

Nonlinear ultrasonic emissions produced during a therapeutic ultrasound procedure can be detected, localized, and quantified through a class of methods that can be referred to as passive acoustic mapping (PAM). While a variety of PAM beamforming algorithms may be employed, they share a common limitation that a single sound speed is specified for both phase steering of array elements and for calculation of source power or energy. The specified value may be inadequate whether derived from B-mode-based metrics or literature values for constituent materials. This study employed experiments and simulations with linear and curvilinear array geometries to investigate the impact of in situ sound speed uncertainties on source localization in layered media. The data were also used to evaluate a new method for optimizing coregistration of PAM and B-mode images. Coregistration errors as large as 10 mm were observed with the curvilinear array, which also showed much greater sound speed sensitivity than the linear array. Errors with both array geometries were typically reduced to the order of 0.1 mm using the proposed optimization method regardless of beamformer choice or whether the array was calibrated. In a further step toward reliable implementation of PAM, the current work provides an approach that can help ensure that therapeutic ultrasound procedures are accurately guided by cavitation emissions.


Assuntos
Acústica , Terapia por Ultrassom , Terapia por Ultrassom/métodos , Ultrassonografia/métodos , Algoritmos , Som
9.
Int J Hyperthermia ; 39(1): 918-934, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35853611

RESUMO

BACKGROUND: PanDox is a Phase-1 trial of chemotherapeutic drug delivery to pancreatic tumors using ultrasound-mediated hyperthermia to release doxorubicin from thermally sensitive liposomes. This report describes trial-related hyperthermia simulations featuring: (i) new ultrasonic properties of human pancreatic tissues, (ii) abdomen deflections imposed by a water balloon, and (iii) respiration-driven organ motion. METHODS: Pancreas heating simulations were carried out using three patient body models. Pancreas acoustic properties were varied between values found in the literature and those determined from our human tissue study. Acoustic beam distortion was assessed with and without balloon-induced abdomen deformation. Target heating was assessed for static, normal respiratory, and jet-ventilation-controlled pancreas motion. RESULTS: Human pancreatic tumor attenuation is 63% of the literature values, so that pancreas treatments require commensurately higher input intensity to achieve adequate hyperthermia. Abdominal wall deformation decreased the peak field pressure by as much as 3.5 dB and refracted the focal spot by as much as 4.5 mm. These effects were thermally counteracted by sidelobe power deposition, so the net impact on achieving mild hyperthermia was small. Respiratory motion during moving beam hyperthermia produced localized regions overheated by more than 8.0 °C above the 4.0 °C volumetric goal. The use of jet ventilation reduced this excess to 0.7 °C and yielded temperature field uniformity that was nearly identical to having no respiratory motion. CONCLUSION: Realistic modeling of the ultrasonic propagation environment is critical to achieving adequate mild hyperthermia without the use of real time thermometry for targeted drug delivery in pancreatic cancer patients.


Assuntos
Parede Abdominal , Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida , Neoplasias Pancreáticas , Acústica , Ensaios Clínicos Fase I como Assunto , Sistemas de Liberação de Medicamentos , Humanos , Hipertermia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/tratamento farmacológico
10.
Expert Opin Drug Deliv ; 19(8): 899-912, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35830722

RESUMO

INTRODUCTION: Many small molecules and biologic therapeutics have been developed for solid tumor therapy. However, the unique physiology of tumors makes the actual delivery of these drugs into the tumor mass inefficient. Such delivery requires transport from blood vessels, across the vasculature and into and through interstitial space within a tumor. This transportation is dependent on the physiochemical properties of the therapeutic agent and the biological properties of the tumor. It was hoped the application of nanoscale drug carrier systems would solve this problem. However, issues with poor tumor accumulation and limited drug release have impeded clinical impact. In response, these carrier systems have been redesigned to be paired with targetable external mechanical stimuli which can trigger much enhanced drug release and deposition. AREAS COVERED: The pre-clinical and clinical progress of thermolabile drug carrier systems and the modalities used to trigger the release of their cargo are assessed. EXPERT OPINION: Combined application of mild hyperthermia and heat-responsive liposomal drug carriers has great potential utility. Clinical trials continue to progress this approach and serve to refine the technologies, dosing regimens and exposure parameters that will provide optimal patient benefit.


Assuntos
Antineoplásicos , Hipertermia Induzida , Neoplasias , Doxorrubicina , Portadores de Fármacos/uso terapêutico , Sistemas de Liberação de Medicamentos , Humanos , Lipossomos/química , Neoplasias/tratamento farmacológico
11.
Magn Reson Med ; 86(6): 3246-3258, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34272767

RESUMO

PURPOSE: A shortage of suitable donor livers is driving increased use of higher risk livers for transplantation. However, current biomarkers are not sensitive and specific enough to predict posttransplant liver function. This is limiting the expansion of the donor pool. Therefore, better noninvasive tests are required to determine which livers will function following implantation and hence can be safely transplanted. This study assesses the temperature sensitivity of proton density fat fraction and relaxometry parameters and examines their potential for assessment of liver function ex vivo. METHODS: Six ex vivo human livers were scanned during static cold storage following normothermic machine perfusion. Proton density fat fraction, T1 , T2 , and T2∗ were measured repeatedly during cooling on ice. Temperature corrections were derived from these measurements for the parameters that showed significant variation with temperature. RESULTS: Strong linear temperature sensitivities were observed for proton density fat fraction (R2 = 0.61, P < .001) and T1 (R2 = 0.78, P < .001). Temperature correction according to a linear model reduced the coefficient of repeatability in these measurements by 41% and 36%, respectively. No temperature dependence was observed in T2 or T2∗ measurements. Comparing livers deemed functional and nonfunctional during normothermic machine perfusion by hemodynamic and biochemical criteria, T1 differed significantly: 516 ± 50 ms for functional versus 679 ± 60 ms for nonfunctional, P = .02. CONCLUSION: Temperature correction is essential for robust measurement of proton density fat fraction and T1 in cold-stored human livers. These parameters may provide a noninvasive measure of viability for transplantation.


Assuntos
Fígado Gorduroso , Transplante de Fígado , Fígado Gorduroso/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão
12.
Mol Ther Oncolytics ; 21: 47-61, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33869742

RESUMO

Vaccinia virus (VV) is a powerful tool for cancer treatment with the potential for tumor tropism, efficient cell-to-cell spread, rapid replication in cancer cells, and stimulation of anti-tumor immunity. It has a well-defined safety profile and is being assessed in late-stage clinical trials. However, VV clinical utility is limited by rapid bloodstream neutralization and poor penetration into tumors. These factors have often restricted its route of delivery to intratumoral or intrahepatic artery injection and may impede repeat dosing. Chemical stealthing improves the pharmacokinetics of non-enveloped viruses, but it has not yet been applied to enveloped viruses such as VV. In the present study, amphiphilic polymer was used to coat VV, leading to reduced binding of a neutralizing anti-VV antibody (81.8% of polymer-coated VV [PCVV] staining positive versus 97.1% of VV [p = 0.0038]). Attachment of anti-mucin-1 (aMUC1) targeting antibody, to give aMUC1-PCVV, enabled binding of the construct to MUC1. In high MUC1 expressing CAPAN-2 cells, infection with PCVV was reduced compared to VV, while infection was restored with aMUC1-PCVV. Pharmacokinetics of aMUC1-PCVV, PCVV, and VV were evaluated. After intravenous (i.v.) injection of 1 × 108 viral genomes (VG) or 5 × 108 VG, circulation time for PCVV and aMUC1-PCVV was increased, with ~5-fold higher circulating dose at 5 min versus VV.

13.
Sci Rep ; 11(1): 4404, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33623089

RESUMO

Triggered release and targeted drug delivery of potent anti-cancer agents using hyperthermia-mediated focused-ultrasound (FUS) is gaining momentum in the clinical setting. In early phase studies, tissue biopsy samples may be harvested to assess drug delivery efficacy and demonstrate lack of instantaneous cell death due to FUS exposure. We present an optimised tissue cell recovery method and a cell viability assay, compatible with intra-cellular doxorubicin. Flow cytometry was used to determine levels of cell death with suspensions comprised of: (i) HT29 cell line exposed to hyperthermia (30 min at 47 °C) and/or doxorubicin, or ex-vivo bovine liver tissue exposed to (ii) hyperthermia (up to 2 h at 45 °C), or (iii) ablative high intensity FUS (HIFU). Flow cytometric analysis revealed maximal cell death in HT29 receiving both heat and doxorubicin insults and increases in both cell granularity (p < 0.01) and cell death (p < 0.01) in cells recovered from ex-vivo liver tissue exposed to hyperthermia and high pressures of HIFU (8.2 MPa peak-to-peak free-field at 1 MHz) relative to controls. Ex-vivo results were validated with microscopy using pan-cytokeratin stain. This rapid, sensitive and highly quantitative cell-viability method is applicable to the small masses of liver tissue typically recovered from a standard core biopsy (5-20 mg) and may be applied to tissues of other histological origins including immunostaining.


Assuntos
Antineoplásicos/toxicidade , Apoptose , Doxorrubicina/toxicidade , Tratamento por Ondas de Choque Extracorpóreas/efeitos adversos , Citometria de Fluxo/métodos , Animais , Bovinos , Células Cultivadas , Células HT29 , Hepatócitos/efeitos dos fármacos , Hepatócitos/efeitos da radiação , Temperatura Alta/efeitos adversos , Humanos , Camundongos
14.
Nanomedicine (Lond) ; 16(1): 37-50, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33426913

RESUMO

Aims: Testing ultrasound-mediated cavitation for enhanced delivery of the therapeutic antibody cetuximab to tumors in a mouse model. Methods: Tumors with strong EGF receptor expression were grown bilaterally. Cetuximab was coadministered intravenously with cavitation nuclei, consisting of either the ultrasound contrast agent Sonovue or gas-stabilizing nanoscale SonoTran Particles. One of the two tumors was exposed to focused ultrasound. Passive acoustic mapping localized and monitored cavitation activity. Both tumors were then excised and cetuximab concentration was quantified. Results: Cavitation increased tumoral cetuximab concentration. When nucleated by Sonovue, a 2.1-fold increase (95% CI 1.3- to 3.4-fold) was measured, whereas SonoTran Particles gave a 3.6-fold increase (95% CI 2.3- to 5.8-fold). Conclusions: Ultrasound-mediated cavitation, especially when nucleated by nanoscale gas-entrapping particles, can noninvasively increase site-specific delivery of therapeutic antibodies to solid tumors.


Assuntos
Nanopartículas , Neoplasias , Animais , Meios de Contraste , Xenoenxertos , Humanos , Camundongos , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Ultrassonografia
15.
Ultrasound Med Biol ; 47(4): 982-997, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33451816

RESUMO

Lyso-thermosensitive liposomes (LTSLs) are specifically designed to release chemotherapy agents under conditions of mild hyperthermia. Preclinical studies have indicated that magnetic resonance (MR)-guided focused ultrasound (FUS) systems can generate well-controlled volumetric hyperthermia using real-time thermometry. However, high-throughput clinical translation of these approaches for drug delivery is challenging, not least because of the significant cost overhead of MR guidance and the much larger volumes that need to be heated clinically. Using an ultrasound-guided extracorporeal clinical FUS device (Chongqing HAIFU, JC200) with thermistors in a non-perfused ex vivo bovine liver tissue model with ribs, we present an optimised strategy for rapidly inducing (5-15 min) and sustaining (>30 min) mild hyperthermia (ΔT <+4°C) in large tissue volumes (≤92 cm3). We describe successful clinical translation in a first-in-human clinical trial of targeted drug delivery of LTSLs (TARDOX: a phase I study to investigate drug release from thermosensitive liposomes in liver tumours), in which targeted tumour hyperthermia resulted in localised chemo-ablation. The heating strategy is potentially applicable to other indications and ultrasound-guided FUS devices.


Assuntos
Adenocarcinoma/tratamento farmacológico , Antibióticos Antineoplásicos/administração & dosagem , Neoplasias Colorretais/patologia , Sistemas de Liberação de Medicamentos , Hipertermia Induzida/instrumentação , Neoplasias Hepáticas/tratamento farmacológico , Ultrassonografia/instrumentação , Adenocarcinoma/secundário , Animais , Bovinos , Análise Custo-Benefício , Sistemas de Liberação de Medicamentos/efeitos adversos , Humanos , Hipertermia Induzida/efeitos adversos , Hipertermia Induzida/métodos , Lipossomos , Fígado , Neoplasias Hepáticas/secundário , Costelas , Temperatura , Ultrassonografia de Intervenção
16.
Artigo em Inglês | MEDLINE | ID: mdl-32845836

RESUMO

Passive acoustic mapping (PAM) techniques have been developed for the purposes of detecting, localizing, and quantifying cavitation activity during therapeutic ultrasound procedures. Implementation with conventional diagnostic ultrasound arrays has allowed planar mapping of bubble acoustic emissions to be overlaid with B-mode anatomical images, with a variety of beamforming approaches providing enhanced resolution at the cost of extended computation times. However, no passive signal processing techniques implemented to date have overcome the fundamental physical limitation of the conventional diagnostic array aperture that results in point spread functions with axial/lateral beamwidth ratios of nearly an order of magnitude. To mitigate this problem, the use of a pair of orthogonally oriented diagnostic arrays was recently proposed, with potential benefits arising from the substantially expanded range of observation angles. This article presents experiments and simulations intended to demonstrate the performance and limitations of the dual-array system concept. The key finding of this study is that source pair resolution of better than 1 mm is now possible in both dimensions of the imaging plane using a pair of 7.5-MHz center frequency conventional arrays at a distance of 7.6cm. With an eye toward accelerating computations for real-time applications, channel count reductions of up to a factor of eight induce negligible performance losses. Modest sensitivities to sound speed and relative array position uncertainties were identified, but if these can be kept on the order of 1% and 1 mm, respectively, then the proposed methods offer the potential for a step improvement in cavitation monitoring capability.


Assuntos
Acústica , Terapia por Ultrassom , Processamento de Sinais Assistido por Computador , Som , Ultrassonografia
17.
Front Med (Lausanne) ; 8: 801098, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35083252

RESUMO

Kidney transplantation is the best renal-replacement option for most patients with end-stage renal disease. Normothermic machine preservation (NMP) of the kidney has been studied extensively during the last two decades and implemented in clinical trials. Biomarker research led to success in identifying molecules with diagnostic, predictive and therapeutic properties in chronic kidney disease. However, perfusate biomarkers and potential predictive mechanisms in NMP have not been identified yet. Twelve discarded human kidneys (n = 7 DBD, n = 5 DCD) underwent NMP for up to 24 h. Eight were perfused applying urine recirculation (URC), four with replacement of urine (UR) using Ringer's lactate. The aim of our study was to investigate biomarkers (NGAL, KIM-1, and L-FABP), cells and cytokines in the perfusate in context with donor characteristics, perfusate hemodynamics and metabolic parameters. Cold ischemia time did not correlate with any of the markers. Perfusates of DBD kidneys had a significantly lower number of leukocytes after 6 h of NMP compared to DCD. Arterial flow, pH, NGAL and L-FABP correlated with donor creatinine and eGFR. Arterial flow was higher in kidneys with lower perfusate lactate. Perfusate TNF-α was higher in kidneys with lower arterial flow. The cytokines IL-1ß and GM-CSF decreased during 6 h of NMP. Kidneys with more urine output had lower perfusate KIM-1 levels. Median and 6-h values of lactate, arterial flow, pH, NGAL, KIM-1, and L-FABP correlated with each other indicating a 6-h period being applicable for kidney viability assessment. The study results demonstrate a comparable cytokine and cell profile in perfusates with URC and UR. In conclusion, clinically available perfusate and hemodynamic parameters correlate well with donor characteristics and measured biomarkers in a discarded human NMP model.

18.
Am J Transplant ; 21(5): 1740-1753, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33021021

RESUMO

We describe a proteomics analysis to determine the molecular differences between normothermically perfused (normothermic machine perfusion, NMP) human kidneys with urine recirculation (URC) and urine replacement (UR). Proteins were extracted from 16 kidney biopsies with URC (n = 8 donors after brain death [DBD], n = 8 donors after circulatory death [DCD]) and three with UR (n = 2 DBD, n = 1 DCD), followed by quantitative analysis by mass spectrometry. Damage-associated molecular patterns (DAMPs) were decreased in kidney tissue after 6 hours NMP with URC, suggesting reduced inflammation. Vasoconstriction was also attenuated in kidneys with URC as angiotensinogen levels were reduced. Strikingly, kidneys became metabolically active during NMP, which could be enhanced and prolonged by URC. For instance, mitochondrial succinate dehydrogenase enzyme levels as well as carbonic anhydrase were enhanced with URC, contributing to pH stabilization. Levels of cytosolic and the mitochondrial phosphoenolpyruvate carboxykinase were elevated after 24 hours of NMP, more prevalent in DCD than DBD tissue. Key enzymes involved in glucose metabolism were also increased after 12 and 24 hours of NMP with URC, including mitochondrial malate dehydrogenase and glutamic-oxaloacetic transaminase, predominantly in DCD tissue. We conclude that NMP with URC permits prolonged preservation and revitalizes metabolism to possibly better cope with ischemia reperfusion injury in discarded kidneys.


Assuntos
Preservação de Órgãos , Proteômica , Homeostase , Humanos , Rim , Perfusão
19.
Transplant Direct ; 6(4): e541, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32309627

RESUMO

The study compares urine recirculation (URC) to urine replacement (UR) with Ringer's lactate in a porcine normothermic kidney machine perfusion (NMP) model using a preclinical prototype device. METHODS: Kidney pairs were recovered uninjured (as live-donor nephrectomy) and perfused consecutively. Pig kidneys (n = 10) were allocated to either NMP with URC (n = 5) or NMP with volume replacement (n = 5). Cold ischemia time was either 2 or 27 hours for the first or second perfusion (URC or UR) of a kidney pair. An autologous blood-based perfusate, leukocyte-filtered, was used and NMP performed up to 24 hours. Perfusion parameters, biochemistry/metabolic parameters were monitored and samples collected. RESULTS: Physiological mean arterial pressures and flows were achieved in both groups but were sustainable only with URC. Significantly higher arterial flow was observed with URC (326.7 ± 1.8 versus 242.5 ± 14.3 mL/min, P = 0.001). Perfusate sodium levels were lower with URC, 129.6 ± 0.7 versus 170.3±2.7 mmol/L, P < 0.001). Stable physiological pH levels were only observed with URC. Perfusate lactate levels were lower with URC (2.2 ± 0.1 versus 7.2 ± 0.5 mmol/L, P < 0.001). Furthermore, the hourly rate of urine output was lower with URC and closer to physiological levels (150 versus 548 mL/h, P = 0.008). Normothermic kidney perfusion with URC was associated with longer achievable durations of perfusion: the objective in all experiments was a 24-hour perfusion, but this was not achieved in every case. The mean perfusions were 17.3 ± 9.2 hours with URC versus 5.3 ± 1.3 hours NMP with UR; P = 0.02. There appeared to be no differences in baseline tubular condition with and without URC. CONCLUSIONS: URC facilitates long-term kidney NMP in a porcine model. Perfusate homeostasis and stability of renal arterial flow throughout the perfusion period was only achievable with URC, independent of cold ischemia time duration.

20.
Ultrasound Med Biol ; 46(5): 1235-1243, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32111455

RESUMO

Many useful therapeutic bio-effects can be generated using ultrasound-induced cavitation. However, cavitation is also capable of causing unwanted cellular and vascular damage, which should be monitored to ensure treatment safety. In this work, the unique opportunity provided by passive acoustic mapping (PAM) to quantify cavitation dose across an entire volume of interest during therapy is utilised to provide setup-independent measures of spatially localised cavitation dose. This spatiotemporally quantifiable cavitation dose is then related to the level of cellular damage generated. The cavitation-mediated destruction of equine red blood cells mixed with one of two types of cavitation nuclei at a variety of concentrations is investigated. The blood is placed within a 0.5-MHz ultrasound field and exposed to a range of peak rarefactional pressures up to 2 MPa, with 50 to 50,000 cycle pulses maintaining a 5% duty cycle. Two co-planar linear arrays at 90° to each other are used to generate 400-µm-resolution frequency domain robust capon beamforming PAM maps, which are then used to generate estimates of cavitation dose. A relationship between this cavitation dose and the levels of haemolysis generated was found which was comparable regardless of the applied acoustic pressure, pulse length, cavitation agent type or concentration used. PAM was then used to monitor cellular damage in multiple locations within a tissue phantom simultaneously, with the damage-cavitation dose relationship being similar for the two experimental models tested. These results lay the groundwork for this method to be applied to other measures of safety, allowing for improved ultrasound monitoring of cavitation-based therapies.


Assuntos
Eritrócitos/fisiologia , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos , Acústica , Animais , Hemólise , Cavalos , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...