RESUMO
ChHV and Mycoplasma agassizii infections in tortoises share similar clinical signs of lethargy, anorexia, rhinitis, and conjunctivitis. In addition, ChHV infection is associated with glossitis and stomatitis and often causes high morbidity and mortality. As was seen in this case, ChHV infection tends to cause higher mortality in T hermanni compared with T graeca and T marginata. T horsfieldi is also considered highly susceptible to ChHV but appeared unaffected in this outbreak.
Assuntos
Surtos de Doenças/veterinária , Infecções por Herpesviridae/veterinária , Infecções por Mycoplasma/veterinária , Tartarugas/virologia , Animais , Diagnóstico Diferencial , Inglaterra/epidemiologia , Evolução Fatal , Feminino , Herpesviridae/isolamento & purificação , Infecções por Herpesviridae/complicações , Infecções por Herpesviridae/epidemiologia , Masculino , Infecções por Mycoplasma/complicações , Infecções por Mycoplasma/epidemiologia , Especificidade da EspécieRESUMO
A case report detailing the presenting clinical signs, diagnostics, and treatment of ulcerative skin disease in a group of koi carp (Cyprinus carpio) is presented.
Assuntos
Carpas , Doenças dos Peixes/patologia , Dermatopatias/veterinária , Temperatura , Úlcera/veterinária , Criação de Animais Domésticos , Animais , Dermatopatias/patologia , Úlcera/patologiaRESUMO
The purpose of this study was to examine the outcome of the application of the high density polyethylene (HDPE)-Jaipur prosthetic construction in fitting trans-femoral amputees in a number of projects throughout the developing world. Projects in Honduras, Uganda and India were included. One hundred and fifty eight (158) patients had been provided with the HDPE-Jaipur prosthesis and of these 72 were seen for a clinical and technical follow-up after a median of 32 months. More than half the amputees seen had amputation due to trauma and the remainder due to disease. Fabrication and fitting in the three projects was carried out by individuals who had undertaken a three week training course provided by Bhagwan Mahaveer Viklang Sahayata Samiti limb centre in Jaipur. The individuals involved had limited background training in prosthetics. Craftsmanship and fit were assessed as being poor in 86% of cases. Failure requiring replacement of components was observed in 50% of cases. There was low patient satisfaction (58%) and patient compliance (65%). The outcome was considered unsatisfactory both technically and clinically. This was a reflection of the inadequacies of the prosthetic construction, particularly the knee joint, and the inadequate training of those involved in fitting and fabrication of the devices.
Assuntos
Membros Artificiais , Polietileno , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Países em Desenvolvimento , Análise de Falha de Equipamento , Seguimentos , Humanos , Perna (Membro) , Pessoa de Meia-Idade , Cooperação do Paciente , Satisfação do Paciente , Desenho de Prótese , Ajuste de PróteseRESUMO
The purpose of this study was to examine the outcome of the application of the High Density Polyethylene (HDPE)-Jaipur prosthetic construction in fitting trans-tibial amputees in a number of projects in the developing world. Projects in Honduras, Uganda and India were visited. Three hundred and twenty (320) patients had been provided with a HDPE-Jaipur prosthesis and of these 172 were seen for a technical and clinical follow-up after a median of 35 months. More than half the amputations were due to trauma, the remainder to disease. Fabrication and fitting in the three projects was carried out by individuals who had undertaken a twice week training course provided by Bhagwan Mahaveer Viklang Sahayata Samiti limb centre in Jaipur. The individuals involved had limited background training in prosthetics. Craftsmanship and fit were assessed as being poor in 56% of cases. The technical quality of the Jaipur foot was considered acceptable as its performance was better than previously observed results. Although there was patient satisfaction of 85% and compliance of 94% the HDPE-Jaipur trans-tibial system was not considered acceptable as 49% reported walking distances less than 1km and 36% discomfort. The major inadequacy in outcome relates to the use for fabrication and fitting of individuals with inadequate education and training.
Assuntos
Amputação Cirúrgica/reabilitação , Membros Artificiais , Polietileno , Tíbia/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Países em Desenvolvimento , Análise de Falha de Equipamento , Seguimentos , Honduras , Humanos , Índia , Perna (Membro) , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Desenho de Prótese , Falha de Prótese , Ajuste de Prótese , UgandaRESUMO
OBJECTIVE: To describe the sonographic findings of septic arthritis of the acromioclavicular joint. DESIGN AND PATIENTS: A retrospective study of five male patients was carried out. Four of the patients were referred because of signs and symptoms suggestive of glenohumeral joint septic arthritis, one for signs and symptoms suggestive of septic arthritis of the acromioclavicular joint. All the acromioclavicular joints were evaluated with ultrasound, aspirated and the aspirate cultured. RESULTS: All patients had normal ultrasound findings of their glenohumeral joints and distended acromioclavicular joints as determined by ultrasound. Ultrasound examination elicited focal tenderness over the acromioclavicular joint. Aspirates of each acromioclavicular joint grew pyogenic organisms. CONCLUSION: Infection in the acromioclavicular joint is uncommon, but is seen in increased frequency in immune-compromised patients and intravenous drug users. A normal glenohumeral joint on ultrasound in a patient suspected of having a septic shoulder should prompt careful review of the acromioclavicular joint. Aspiration of the acromioclavicular joint is easily performed under ultrasound guidance.
Assuntos
Articulação Acromioclavicular/diagnóstico por imagem , Artrite Infecciosa/diagnóstico por imagem , Infecções Estafilocócicas/diagnóstico , Staphylococcus aureus/isolamento & purificação , Infecções Estreptocócicas/diagnóstico , Streptococcus pneumoniae/isolamento & purificação , Articulação Acromioclavicular/microbiologia , Adulto , Artrite Infecciosa/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estreptocócicas/diagnóstico por imagem , Sucção , UltrassonografiaRESUMO
OBJECTIVE: To demonstrate the MR depiction of the intertrochanteric or femoral neck extension of fractures of the greater trochanter, when standard radiographs show only a fracture of the greater trochanter. DESIGN AND PATIENTS: A retrospective review was performed of the MR and radiographic findings in 13 consecutive patients (10 men, 3 women; ages 24-86 years) with radiographic evidence of fracture of the greater trochanter who were examined with MR imaging. RESULTS: The MR study displayed the fracture of the greater trochanter in all cases. In all but three patients, MR examinations displayed an extension of the fracture into the intertrochanteric region, and in one, also an extension into the femoral neck, although the cortex at this level was not interrupted. CONCLUSION: When there is radiographic evidence of an isolated fracture of the greater trochanter, MR often shows an intertrochanteric or femoral neck extension of the fracture in both young and older adults. This finding may be a factor in determining the need for surgical intervention.
Assuntos
Fêmur/patologia , Fraturas do Quadril/patologia , Imageamento por Ressonância Magnética , Acidentes por Quedas , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/patologia , Fêmur/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos RetrospectivosRESUMO
OBJECTIVE: The objective is to evaluate the sonographic characteristics of Morton's neuromas and the usefulness of sonography in detecting them. MATERIALS AND METHODS: Thirty intermetatarsal spaces were evaluated with sonography to diagnose Morton's neuromas. The prospective sonographic reports were correlated with surgical and pathologic findings. Each sonogram was then blindly and retrospectively reviewed to characterize mass echotexture, location, size, and continuity with the plantar digital nerve when present. RESULTS: Surgery revealed 27 Morton's neuromas, one synovial cyst with infarcted tissue, one ganglion cyst, and one giant cell tumor of the tendon sheath. The prospective sonographic reports correctly identified neuromas in 85% of the cases. Retrospectively, 79.2% (19/24) of the neuromas were characterized as hypoechoic compared with muscle, whereas 12.5% (3/24) were of mixed echotexture and 8.3% (2/24) were anechoic. One half (50%) of the neuromas were located dorsal to the plantar aspect of the metatarsal heads, and 50% were both dorsal and plantar to this level. No statistical difference in height and width was found between neuromas and nonneuromas; however, nonneuromas were statistically greater in length than neuromas. All 15 masses in which presumed plantar digital nerve continuity with the mass was identified were neuromas. CONCLUSION: Sonography can reveal a Morton's neuroma in 85% of cases. Identification of the presumed plantar digital nerve in continuity with the mass improves diagnostic confidence. The finding of an interdigital mass greater than 20 mm in length should raise suspicion of an abnormality other than a neuroma.
Assuntos
Doenças do Pé/diagnóstico por imagem , Neuroma/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , UltrassonografiaRESUMO
BACKGROUND: The use of continuous electromyographic and somatosensory-evoked-potential monitoring systems has been advocated to assist in avoiding nerve-root injury during operations on the pelvic ring. More recently, it was suggested that stimulus-evoked electromyographic monitoring may further decrease the risk of iatrogenic nerve-root injury during posterior pelvic fixation by enabling the surgeon to determine the actual distance of an implant from a nerve root. The purpose of the current study was to evaluate the relative efficacy of these three methods of monitoring for minimizing the risk of neural injury during the placement of iliosacral implants. METHODS: While the function of the first sacral nerve root was monitored with the use of stimulus-evoked electromyographic, continuous electromyographic, and somatosensory-evoked-potential monitoring techniques, a 2.0-millimeter stainless-steel Kirschner wire was progressively inserted, guided by a high-speed computerized tomographic scanner, into the first sacral body of seventeen hemipelves in nine dogs. The end point was contact with the nerve as demonstrated by the computerized tomographic images. It was expected that this end point would be heralded by a burst of spontaneous electromyographic activity and an abnormal somatosensory-evoked-potential signal. Anatomical dissection at the completion of the study documented the final position of the Kirschner wire. RESULTS: Anatomical dissection demonstrated compression or penetration of the nerve root in sixteen of the seventeen specimens. A spontaneous burst of electromyographic activity was not recorded for any specimen on continuous electromyographic monitoring; this finding was significantly different from what had been expected (p<0.001). Because of technical problems, somatosensory evoked potentials could be recorded for only twelve hemipelves that had nerve-root compression or penetration, and abnormal somatosensory evoked potentials were recorded for only one of the twelve; this finding was significantly different from what had been expected (p<0.001). A total of 113 stimulus-evoked electromyographic data points were obtained. The correlation coefficient for the relationship between the current threshold recorded with stimulus-evoked electromyographic monitoring and the distance of the wire from the nerve was 0.801 (p<0.001). The actual measured current thresholds were of an observed proportion not different from what had been expected (p = 0.48). CONCLUSIONS: Continuous electromyographic and somatosensory-evoked-potential monitoring techniques failed to indicate contact with the nerve root reliably in this animal model. However, stimulus-evoked electromyographic monitoring consistently provided reliable information indicating the proximity of the implant to the nerve root.
Assuntos
Fios Ortopédicos , Ílio/cirurgia , Cuidados Intraoperatórios , Complicações Intraoperatórias/prevenção & controle , Sacro/cirurgia , Raízes Nervosas Espinhais/fisiologia , Animais , Fios Ortopédicos/efeitos adversos , Limiar Diferencial , Modelos Animais de Doenças , Dissecação , Cães , Estimulação Elétrica , Eletromiografia , Estudos de Avaliação como Assunto , Potenciais Somatossensoriais Evocados/fisiologia , Doença Iatrogênica , Síndromes de Compressão Nervosa/etiologia , Reprodutibilidade dos Testes , Fatores de Risco , Limiar Sensorial , Raízes Nervosas Espinhais/lesões , Aço Inoxidável , Tomógrafos ComputadorizadosRESUMO
The majority of fluid collections in the musculoskeletal system can be localized and aspirated under ultrasound guidance. Whether fluid is infected cannot be determined from ultrasound appearances and laboratory analysis is required. In complicated infection, particularly septic arthritis and osteomyelitis, combined use of MR imaging and aspiration under ultrasound is very useful.
Assuntos
Infecções/diagnóstico por imagem , Doenças Musculoesqueléticas/diagnóstico por imagem , Abscesso/diagnóstico por imagem , Artrite Infecciosa/diagnóstico por imagem , Bursite/diagnóstico por imagem , Celulite (Flegmão)/diagnóstico por imagem , Humanos , Infecções/microbiologia , Doenças Musculoesqueléticas/microbiologia , Miosite/diagnóstico por imagem , Osteomielite/diagnóstico por imagem , Dermatopatias/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , UltrassonografiaRESUMO
This article reviews the ultrasound appearance of common fractures that may mimic other pathologies. Recent works suggest a role for ultrasound in the assessment of callus formation in delayed union of fractures and following the Ilizarov reconstructive procedures.
Assuntos
Osso e Ossos/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Cicatrização , Osso e Ossos/fisiopatologia , Osso e Ossos/cirurgia , Fixação de Fratura/métodos , Fraturas Ósseas/fisiopatologia , Fraturas Ósseas/cirurgia , Humanos , Técnica de Ilizarov , UltrassonografiaRESUMO
PURPOSE: To examine growth plates of the distal femur and tibia with magnetic resonance (MR) imaging to detect bone bridges and other deformities in children. MATERIALS AND METHODS: Thirteen children (nine boys and four girls, aged 5-13 years; mean age, 9.8 years) were referred because of suspected or known bone bridging of the growth plate. Among the 13 patients, 10 had Salter-Harris fractures of the knee or ankle, two had Blount disease, and one had neonatal sepsis. Fat-saturated spoiled gradient-recalled images enabled reconstruction of a three-dimensional model of the growth plate. Patients underwent one to four MR examinations. RESULTS: Nine patients had bone bridging of less than 1% to 39% of the area of the growth plate. On MR images obtained in the growth plate of five patients, a stripe of low signal intensity indicated fracture. On MR images obtained in three patients, intrusions of growth plate cartilage into the metaphysis were seen to increase in depth over time. MR images obtained in four patients showed no bridges. In the two patients who underwent surgery, excellent correspondence was found between MR findings and surgical observations. CONCLUSION: Marked undulation or splitting of the growth plate may occur with fixation of some cartilage in the metaphysis or epiphysis while growth continues. The configuration of the growth plate and bone bridges can be accurately mapped with MR imaging. Treatment planning is facilitated.
Assuntos
Fêmur/patologia , Lâmina de Crescimento/patologia , Imageamento por Ressonância Magnética , Tíbia/patologia , Adolescente , Traumatismos do Tornozelo/complicações , Doenças do Desenvolvimento Ósseo/diagnóstico , Doenças do Desenvolvimento Ósseo/etiologia , Cartilagem/patologia , Criança , Pré-Escolar , Simulação por Computador , Feminino , Fêmur/lesões , Fraturas Ósseas/complicações , Lâmina de Crescimento/crescimento & desenvolvimento , Humanos , Processamento de Imagem Assistida por Computador , Traumatismos do Joelho/complicações , Masculino , Planejamento de Assistência ao Paciente , Fraturas Salter-Harris , Sepse/complicações , Tíbia/lesõesRESUMO
An unusual case is presented here of simple bone cyst (SBC) with fluid-fluid levels on MR and cementum-like substance on microscopy in an atypical location in the distal femur. Fluid-fluid levels are commonly described in the literature within aneurysmal bone cysts, giant cell tumour, chondroblastomas and telangiectatic osteosarcomas, but a literature review revealed only one reported case with multiple fluid levels occurring in a simple bone cyst on MRI. A cementum-like matrix is diagnostic of SBC and is seen in approximately 10% of cases.
Assuntos
Cistos Ósseos/patologia , Fêmur/patologia , Imageamento por Ressonância Magnética , Cistos Ósseos/diagnóstico , Criança , Fraturas do Fêmur/patologia , Fraturas Espontâneas/patologia , Humanos , MasculinoRESUMO
A consecutive series of twenty-seven patients who had thirty acute unstable (type-C) fractures of the pelvic ring was studied prospectively to evaluate the use of stimulus-evoked electromyography to decrease the risk of iatrogenic nerve-root injury during the insertion of iliosacral screws. A prerequisite for inclusion in the study was a normal neurological status preoperatively; somatosensory evoked potentials were monitored to further document the neurological status both before and after insertion of the screw or screws. A total of fifty-one iliosacral screws were inserted, and a current threshold of more than eight milliamperes was selected as the level that indicated that the drill-bit was a safe distance from the nerve root. Four of the fifty-one screws were redirected because of information obtained with stimulus-evoked electromyography. Postoperatively, all patients had a normal neurological status. Computerized tomography, although not accurate for detailed measurements, demonstrated that all of the screws were in a safe, intraosseous position. Monitoring with stimulus-evoked electromyography appears to provide reliable data and may decrease the risk of iatrogenic injury to the nerve roots during operations on the pelvic ring.
Assuntos
Parafusos Ósseos , Eletromiografia , Potenciais Somatossensoriais Evocados , Ílio/cirurgia , Monitorização Intraoperatória , Sacro/cirurgia , Adolescente , Adulto , Feminino , Fixação Interna de Fraturas , Humanos , Ílio/diagnóstico por imagem , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/lesões , Estudos Prospectivos , Sacro/diagnóstico por imagem , Raízes Nervosas Espinhais/lesões , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: Ultrasound is thought to be clinically useful in evaluating bone formation through its presumed identification of fracture callus. However, documentation of the actual histology of the tissue identified by ultrasound has been lacking. The purpose of this study was to determine the histologic composition of the hyperechoic tissue "seen" by ultrasound. STUDY DESIGN: Unilateral fractures were created in eight canine tibias and then fixed by using locked intramedullary nailing without reaming. The limbs were studied at two, three, four, six, and eight weeks postoperatively with plain radiographs, ultrasound, and ultrasound-directed needle biopsy. RESULTS: The presence of a hyperechoic ultrasound signal was found to have a 100 percent correlation with the presence of hard fracture callus biopsy tissue. In addition, fracture union by ultrasound criteria significantly predated radiographic fracture union (5.6 vs. 7.3 weeks, p = 0.05). CONCLUSIONS: These results support and provide a scientific basis for the clinical use of ultrasound to assess tibial fracture healing following static interlocked nailing without reaming.
Assuntos
Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura/fisiologia , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Animais , Biópsia por Agulha , Calo Ósseo/diagnóstico por imagem , Cães , Radiografia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/patologia , Fatores de Tempo , UltrassonografiaRESUMO
OBJECTIVE: Based on the results of a pilot study indicating the potential value of ultrasound (US) as a diagnostic tool for the early assessment of fracture healing and the related need for secondary operative procedures in patients treated by statically locked intramedullary (IM) nailing without reaming, a protocol was established for a larger scale prospective trial. The purpose of this study was to evaluate the outcome of this follow-up trial. DESIGN/METHODS: All skeletally mature patients admitted to the Henry Ford Hospital (Detroit, Michigan) from January 1993 to August 1994 who had sustained an acute fracture of the tibial shaft and who were treated by statically locked IM nailing, without reaming, were candidates for study. Forty-seven patients with fifty fractures that could be evaluated by US were included. The adopted determinants for fracture healing were complete disappearance of the IM nail on US examination performed at six weeks postoperatively, or progressive disappearance of the nail noted between the initial six-week study and a second nine-week US examination, both in conjunction with periosteal callus formation. Radiographs were obtained to monitor maintenance of reduction and to further evaluate fracture healing. RESULTS: Of thirty-eight fractures with a positive US (thirty-two at six weeks, six at nine weeks), thirty-seven healed uneventfully, a positive predictive value of 97 percent. Radiographic fracture healing was not evident until, on average, nineteen weeks after injury. The single false-positive fracture progressed to nonunion. Of the twelve fractures with negative US studies, ten underwent secondary procedures (nine dynamization, one bone graft), with four progressing to nonunion. Two patients refused secondary surgery; screw failure occurred in both. Otherwise, there were no hardware failures in this series. CONCLUSIONS: The results of this study indicate that US may provide important prognostic information concerning fracture healing after unreamed tibial nailing, upon which subsequent treatment can be based.
Assuntos
Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura/fisiologia , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Idoso , Reações Falso-Positivas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Falha de Prótese , Reoperação , Resultado do Tratamento , UltrassonografiaRESUMO
For specific indications, ultrasound (US) is an efficient and inexpensive alternative to magnetic resonance (MR) imaging for evaluation of the ankle. In addition to the tendons and tendon sheaths, other ankle structures demonstrated with US include the anterior joint space, retrocalcaneal bursa, ligaments, and plantar fascia. Ankle US allows detection of tenosynovitis and tendinitis, as well as partial and complete tendon tears. Joint effusions, intraarticular bodies, ganglion cysts, ligamentous tears, and plantar fasciitis can also be diagnosed. As pressure for cost containment continues, demand for US of the ankle may increase given its lower cost compared with that of MR imaging. In most cases, a focused ankle US examination can be performed more rapidly and efficiently than MR imaging. Familiarity with the technique of ankle US, normal US anatomy, and the US appearances of pathologic conditions will establish the role of US as an effective method of imaging the ankle.
Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/anatomia & histologia , Humanos , Artropatias/diagnóstico por imagem , Ultrassonografia/métodosRESUMO
OBJECTIVE: A canine model was designed to evaluate the feasibility of stimulus-evoked electromyographic (EMG) monitoring of the lumbosacral nerve roots during the insertion of iliosacral implants. STUDY DESIGN/METHODS: Four 2.5-millimeter Kirschner wires (K-wires) were percutaneously inserted under general anesthesia into the S1 body of each of five dog hemipelves using C-arm fluoroscopy image-intensifier control in an actual attempt to compromise the S1 canal and the S1 nerve root. A searching current of twenty milliamperes was initially applied to the K-wire with monitoring electrodes placed in the gastrocnemius muscle. Current thresholds required to evoke an EMG response were recorded for each K-wire. Actual K-wire location was determined by anatomical dissection. RESULTS: Evaluation of these twenty wires revealed that current threshold was directly related to the proximity of the K-wire to the nerve root, with a correlation coefficient of 0.94 (p < 0.001). CONCLUSIONS: Stimulus-evoked EMG monitoring provided reliable data indicating the proximity of the iliosacral implants to the sacral nerve root. This method of intraoperative nerve monitoring could potentially decrease the risk of iatrogenic nerve root injury during pelvic ring surgery. Further study is warranted.
Assuntos
Fios Ortopédicos , Modelos Animais de Doenças , Eletromiografia , Ílio/inervação , Monitorização Intraoperatória , Sacro/inervação , Animais , Parafusos Ósseos , Cães , Estudos de ViabilidadeRESUMO
PURPOSE: To determine the efficacy of ultrasonography (US) for the detection of intraarticular bodies. MATERIALS AND METHODS: US was performed in 280 patients with symptoms in various appendicular joints by using 5.0-, 7.5-, or 10.0-MHz transducers. Three patients also underwent US with intraarticular saline infusion. US findings were confirmed at surgery in 61 patients. RESULTS: In the 61 patients with surgical correlation, sonograms were positive in 39 and did not show intraarticular bodies in 22. Surgical results confirmed 37 of the positive and all of the negative sonograms. Sensitivity and specificity of US were 100% and 95%, respectively. CONCLUSION: US is an accurate method for identification of intraarticular bodies.
Assuntos
Corpos Livres Articulares/diagnóstico por imagem , Adulto , Meios de Contraste , Estudos de Avaliação como Assunto , Feminino , Humanos , Corpos Livres Articulares/epidemiologia , Masculino , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Cloreto de Sódio , UltrassonografiaRESUMO
PURPOSE: To evaluate the use of ultrasound (US) for detection of wooden foreign bodies implanted in cadaveric specimens. MATERIALS AND METHODS: Wooden foreign bodies were randomly placed in the plantar soft tissues of three cadaver feet by using 5-mm-long incisions. Ten foreign bodies were 2.5 x 1.0 mm (length x diameter); 10 were 5.0 x 1.0 mm. Ten incisions were performed without implantation of foreign bodies. Three musculoskeletal radiologists independently performed US in blinded fashion and recorded the presence of a foreign body. Each used 7.5- and 10-MHz linear-array transducers and was informed of the possible presence of a foreign body. RESULTS: Sensitivity and specificity for detection of 2.5-mm-long foreign bodies were 86.7% and 96.7%, respectively. Sensitivity and specificity for detection of 5.0-mm-long foreign bodies were 93.3% and 96.7%, respectively. Overall sensitivity was 90.0%, with specificity of 96.7%, accuracy of 92.3%, positive predictive value of 98.0%, and negative predictive value of 83.0%. CONCLUSION: US can be used effectively to locate wooden foreign bodies as small as 2.5 mm in length. Given that many foreign bodies are radiographically undetectable, the accuracy and availability of US make it an excellent modality for evaluation of radiolucent foreign bodies.
Assuntos
Pé , Corpos Estranhos/diagnóstico por imagem , Madeira , Cadáver , Corpos Estranhos/epidemiologia , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , UltrassonografiaRESUMO
Asymptomatic pneumatosis may be found in patients with lymphangiomatosis of bone. The authors report three cases from three institutions in which development of intraosseous gas in association with lymphangiomatosis of bone was found incidentally at imaging. Soft-tissue emphysema also developed in two cases. In all three cases, intraosseous gas developed after biopsy or surgery in the areas involved with lymphangiomatosis.