Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 38(7): 1356-1361, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28495947

RESUMO

BACKGROUND AND PURPOSE: The Embolus Retriever with Interlinked Cages (ERIC) device is a novel stent retriever for mechanical thrombectomy. It consists of interlinked cages and could improve procedural benchmarks and clinical outcome compared with classic stent retrievers. This study compares the rates of recanalization, favorable clinical outcome, procedural adverse events, and benchmarks between the ERIC device and classic stent retrievers. MATERIALS AND METHODS: From 545 patients treated with thrombectomy between 2012 and 2015, 316 patients were included. The mean age was 69 ±13 years, the mean baseline NIHSS score was 17 ± 5, and 174 (55%) were men. The ERIC was used as the primary thrombectomy device in 59 (19%) patients. In a propensity score matched analysis including the NIHSS score, clot location, delay to groin puncture, neurointerventionalist, and anesthetic management, 57 matched pairs were identified. RESULTS: Patients treated with the ERIC device compared with classic stent retrievers showed equal rates of recanalization (86% versus 81%, P = .61), equal favorable 3-month clinical outcome (mRS 0-2: 46% versus 40%, P = .71), and procedural adverse events (28% versus 30%, P = 1.00). However, in patients treated with the ERIC device, thrombectomy procedures were less time-consuming (67 versus 98 minutes, P = .009) and a rescue device was needed less often (18% versus 39%, P = .02) compared with classic stent retrievers. CONCLUSIONS: Mechanical thrombectomy with the ERIC device is effective and safe. Rates of favorable procedural and clinical outcomes are at least as good as those with classic stent retrievers. Of note, the ERIC device might be time-saving and decrease the need for rescue devices. These promising results call for replication in larger prospective clinical trials.


Assuntos
Isquemia Encefálica/cirurgia , Embolia Intracraniana/cirurgia , Acidente Vascular Cerebral/cirurgia , Instrumentos Cirúrgicos , Trombectomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia , Estudos de Casos e Controles , Remoção de Dispositivo , Feminino , Virilha , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Pontuação de Propensão , Punções , Estudos Retrospectivos , Stents , Instrumentos Cirúrgicos/efeitos adversos , Trombectomia/efeitos adversos , Resultado do Tratamento
2.
AJNR Am J Neuroradiol ; 38(1): 127-131, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27932510

RESUMO

BACKGROUND AND PURPOSE: The introduction of liquid embolic agents has revolutionized endovascular approach to cranial vascular malformations. The aim of the study was to retrospectively assess the efficacy and safety of Precipitating Hydrophobic Injectable Liquid (PHIL), a new nonadhesive liquid embolic agent, in the treatment of patients with cranial dural arteriovenous fistulas. The primary end point was the rate of complete occlusion of dural arteriovenous fistulas. Secondary end points included the incidence of adverse events and clinical status at 3-month follow-up. MATERIALS AND METHODS: This was a retrospective multicenter study. Twenty-six consecutive patients with dural arteriovenous fistulas (de novo or previously treated) treated by injection of PHIL only or with PHIL in combination with other embolization products (such as Onyx or detachable coils) were included in the study. Recruitment started in August 2014 and ended in September 2015. RESULTS: Twenty-two (85%) patients were treated with PHIL only, with 3 patients treated with both PHIL and Onyx, and 1, with both PHIL and coils. Immediate complete angiographic occlusion was achieved in 20 (77%) patients. Of the 6 patients with residual fistulas, 3 were retreated with PHIL and 1 achieved angiographic cure. An adverse event was seen in 1 patient who developed worsening of preexisting ataxia due to acute thrombosis of the draining vein. CONCLUSIONS: PHIL appears to be safe and effective for endovascular treatment of cranial dural arteriovenous fistulas. Short-term angiographic and clinical results are comparable with those of Onyx, with the added advantage of easier preparation and improved homogeneous cast visualization. The use of iodine as a radio-opacifier also produces considerably less artifacts on CT compared with tantalum-based embolic materials.


Assuntos
Embolização Terapêutica/métodos , Malformações Arteriovenosas Intracranianas/terapia , Adulto , Idoso , Dimetil Sulfóxido/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polivinil/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...