Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Int J Pharm ; 568: 118496, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31279053

RESUMO

Magnetic resonance angiography (MRA) requires the use of contrast agents (CAs) to enable accurate diagnosis. There are currently no CAs on the market with appropriate pharmacokinetic (PK) parameters, namely long persistence in the blood, that can be easily used for MRA. We have recently synthesized amphiphilic building blocks loaded with gadolinium (Gd), which self-assemble into Gd-micelles in aqueous media, and have evaluated their potential as a blood-pool contrast agent (BPCA) in vivo. To assess the short and long term PK of Gd-micelles, the blood and organs of the mice were analyzed at t = 30 min, 1, 2, 3 h, 7, 14 and 21 days. Gd-DOTA was used as a control because it is the gold-standard CA for MRA despite its rapid clearance from the blood compartment. Gd-micelles circulated in the blood for more than 3 h postinjection whereas Gd-DOTA was eliminated less than half an hour postinjection. No side effects were observed in the mice up to the end of the study at 21 days and no accumulation of Gd was observed in the brain or bones. The Magnetic Resonance Imaging (MRI) parameters and the results of this in vivo study indicate the true BCPA properties of Gd-micelles and warrant further development.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio/farmacocinética , Compostos Heterocíclicos/farmacocinética , Micelas , Compostos Organometálicos/farmacocinética , Animais , Sobrevivência Celular/efeitos dos fármacos , Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Compostos Heterocíclicos/administração & dosagem , Humanos , Células MCF-7 , Imageamento por Ressonância Magnética , Masculino , Camundongos Endogâmicos BALB C , Compostos Organometálicos/administração & dosagem , Distribuição Tecidual
2.
Bone Joint Res ; 8(1): 11-18, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30800295

RESUMO

OBJECTIVES: Tranexamic acid (TXA) is an anti-fibrinolytic medication commonly used to reduce perioperative bleeding. Increasingly, topical administration as an intra-articular injection or perioperative wash is being administered during surgery. Adult soft tissues have a poor regenerative capacity and therefore damage to these tissues can be harmful to the patient. This study investigated the effects of TXA on human periarticular tissues and primary cell cultures using clinically relevant concentrations. METHODS: Tendon, synovium, and cartilage obtained from routine orthopaedic surgeries were used for ex vivo and in vitro studies using various concentrations of TXA. The in vitro effect of TXA on primary cultured tenocytes, fibroblast-like synoviocytes, and chondrocytes was investigated using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cell viability assays, fluorescent microscopy, and multi-protein apoptotic arrays for cell death. RESULTS: There was a significant (p < 0.01) increase in cell death within all tissue explants treated with 100 mg/ml TXA. MTT assays revealed a significant (p < 0.05) decrease in cell viability in all tissues following treatment with 50 mg/ml or 100 mg/ml of TXA within four hours. There was a significant (p < 0.05) increase in cell apoptosis after one hour of exposure to TXA (100 mg/ml) in all tissues. CONCLUSION: The current study demonstrates that TXA caused significant periarticular tissue toxicity ex vivo and in vitro at commonly used clinical concentrations.Cite this article: M. McLean, K. McCall, I. D. M. Smith, M. Blyth, S. M. Kitson, L. A. N. Crowe, W. J. Leach, B. P. Rooney, S. J. Spencer, M. Mullen, J. L. Campton, I. B. McInnes, M. Akbar, N. L. Millar. Tranexamic acid toxicity in human periarticular tissues. Bone Joint Res 2019;8:11-18. DOI: 10.1302/2046-3758.81.BJR-2018-0181.R1.

3.
Sci Rep ; 6: 30088, 2016 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-27439482

RESUMO

A need exists to noninvasively assess renal interstitial fibrosis, a common process to all kidney diseases and predictive of renal prognosis. In this translational study, Magnetic Resonance Imaging (MRI) T1 mapping and a new segmented Diffusion-Weighted Imaging (DWI) technique, for Apparent Diffusion Coefficient (ADC), were first compared to renal fibrosis in two well-controlled animal models to assess detection limits. Validation against biopsy was then performed in 33 kidney allograft recipients (KARs). Predictive MRI indices, ΔT1 and ΔADC (defined as the cortico-medullary differences), were compared to histology. In rats, both T1 and ADC correlated well with fibrosis and inflammation showing a difference between normal and diseased kidneys. In KARs, MRI indices were not sensitive to interstitial inflammation. By contrast, ΔADC outperformed ΔT1 with a stronger negative correlation to fibrosis (R(2) = 0.64 against R(2) = 0.29 p < 0.001). ΔADC tends to negative values in KARs harboring cortical fibrosis of more than 40%. Using a discriminant analysis method, the ΔADC, as a marker to detect such level of fibrosis or higher, led to a specificity and sensitivity of 100% and 71%, respectively. This new index has potential for noninvasive assessment of fibrosis in the clinical setting.


Assuntos
Fibrose/diagnóstico , Fibrose/patologia , Processamento de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico , Nefropatias/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Animais , Feminino , Histocitoquímica , Humanos , Masculino , Pessoa de Meia-Idade , Ratos , Sensibilidade e Especificidade
4.
Br J Surg ; 103(4): 417-26, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26891212

RESUMO

BACKGROUND: Livers with parenchymal abnormalities tolerate ischaemia-reperfusion (IR) injury poorly. IR injury is a risk factor for hepatocellular carcinoma (HCC) recurrence. This study assessed the link between liver parenchymal abnormalities and HCC recurrence, and evaluated the protective effect of ischaemic preconditioning. METHODS: C57BL/6 mice were fed a choline-deficient diet for 6 and 12 weeks, or standard chow. Hepatic IR and ischaemic preconditioning were achieved by clamping liver blood inflow. Hepa 1-6 HCC cells were inoculated through the spleen. Thereafter, tumour burden, serum α-fetoprotein and cancer cell aggressiveness were compared among groups. RESULTS: Hepatocellular damage and expression of inflammatory genes (encoding interleukin 6, tumour necrosis factor α, hypoxia inducible factor 1α and E-selectin) were exacerbated after IR injury in mice with severe steatosis. Compared with control livers or those with minimal steatosis, livers exposed to a prolonged choline-deficient diet developed larger tumour nodules and had higher serum α-fetoprotein levels. Non-ischaemic liver lobes from mice with steatosis were not protected from accelerated tumour growth mediated by IR injury. This remote effect was linked to promotion of the aggressiveness of HCC cells. Ischaemic preconditioning before IR injury reduced the tumour burden to the level of that in non-ischaemic steatotic controls. This protective effect was associated with decreased cancer cell motility. CONCLUSION: Livers with steatosis tolerated IR poorly, contributing to more severe HCC recurrence patterns in mice with increasingly severe steatosis. IR injury also had a remote effect on cancer cell aggressiveness. Ischaemic preconditioning before IR injury reduced tumour load and serum α-fetoprotein levels. SURGICAL RELEVANCE: Liver ischaemia-reperfusion (IR) injury is associated with organ dysfunction and surgical morbidity. Livers with steatosis tolerate IR injury poorly in the setting of both liver resection and liver transplantation. Ischaemic preconditioning is a simple method to mitigate IR injury. This study shows that ischaemic preconditioning of mouse livers with steatosis reduces ischaemia-mediated tumour growth acceleration. Liver parenchymal abnormalities such as warm IR injury and liver steatosis should be taken into account to predict accurately the risk of liver cancer recurrence after surgical management. Ischaemic preconditioning strategies may hold therapeutic potential not only to mitigate surgical morbidity but also to reduce postoperative recurrence of liver cancer.


Assuntos
Carcinoma Hepatocelular/terapia , Fígado Gorduroso/etiologia , Precondicionamento Isquêmico/métodos , Neoplasias Hepáticas/terapia , Neoplasias Experimentais , Animais , Biomarcadores Tumorais/biossíntese , Biomarcadores Tumorais/genética , Western Blotting , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/patologia , Linhagem Celular Tumoral , Movimento Celular , Proliferação de Células , DNA de Neoplasias/genética , Fígado Gorduroso/genética , Fígado Gorduroso/terapia , Regulação da Expressão Gênica , Imuno-Histoquímica , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reação em Cadeia da Polimerase em Tempo Real
5.
Magn Reson Med ; 68(5): 1544-52, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22294467

RESUMO

The emerging importance of nanoparticle technology, including iron oxide nanoparticles for monitoring development, progression, and treatment of inflammatory diseases such as arthritis, drives development of imaging techniques. Studies require an imaging protocol that is sensitive and quantifiable for the detection of iron oxide over a wide range of concentrations. Conventional signal loss measurements of iron oxide nanoparticle containing tissues saturate at medium concentrations and show a nonlinear/nonproportional intensity to concentration profile due to the competing effects of T1 and T2 relaxation. A concentration calibration phantom and an in vivo study of intra-articular injection in a rat knee of known concentrations of iron oxide were assessed using the difference-ultrashort echo time sequence giving a positive, quantifiable, unambiguous iron signal and monotonic, increasing concentration response over a wide concentration range in the phantom with limited susceptibility artifacts and high contrast in vivo to all other tissues. This improved dynamic response to concentration opens possibilities for quantification due to its linear nature at physiologically relevant concentrations.


Assuntos
Algoritmos , Dextranos/administração & dosagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Articulações/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/administração & dosagem , Animais , Meios de Contraste/administração & dosagem , Feminino , Injeções Intra-Arteriais , Ratos , Ratos Endogâmicos Lew , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Am J Transplant ; 11(6): 1158-68, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21564535

RESUMO

The Automatic Quantitative Ultrashort Echo Time imaging (AQUTE) protocol for serial MRI allows quantitative in vivo monitoring of iron labeled pancreatic islets of Langerhans transplanted into the liver, quantifying graft implantation and persistence in a rodent model. Rats (n = 14), transplanted with iron oxide loaded cells (0-4000 islet equivalents, IEQ), were imaged using a 3D radial ultrashort echo time difference technique (dUTE) on a Siemens MAGNETOM 3T clinical scanner up to 5 months postsurgery. In vivo 3D dUTE images gave positive contrast from labeled cells, suppressing liver signal and small vessels, allowing automatic quantification. Position of labeled islet clusters was consistent over time and quantification of hyperintense pixels correlated with the number of injected IEQs (R² = 0.898, p < 0.0001), and showed persistence over time (5 months posttransplantation). Automatic quantification was superior to standard imaging and manual counting methods, due to the uniform suppressed background and high contrast, resulting in significant timesavings, reproducibility and ease of quantification. Three-dimensional coverage of the whole liver in the absence of cardiac/respiratory artifact provided further improvement over conventional imaging. This imaging protocol reliably quantifies transplanted islet mass and has high translational potential to clinical studies of transplanted pancreatic islets.


Assuntos
Meios de Contraste , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
7.
Atherosclerosis ; 183(2): 361-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16285999

RESUMO

PURPOSE: To determine, in asymptomatic subjects, the inter-study reproducibility of a three-dimensional (3D) volume selective fast spin echo (FSE) cardiovascular magnetic resonance sequence for the assessment of carotid artery wall volume as a measure of atheroma burden. METHODS: Inter-study reproducibility was evaluated in 16 asymptomatic volunteers (10 male, 6 female). Both carotid arteries were scanned twice with a median inter-scan time of 5 days. The images were acquired in cross-section, and the total carotid arterial wall volume (TWV) was calculated by subtraction of the total carotid lumen volume from the total outer carotid vessel volume. RESULTS: The mean carotid T1-weighted TWV for the first and second scans was 828 and 821 mm(3), respectively (mean difference 7 mm(3), p=0.45). The standard deviation (S.D.) of the differences between the measurements was 38 mm(3) yielding an inter-study coefficient of variation of 4.6%. The time for each study was approximately 30 min. For the longitudinal evaluation of carotid atheroma burden with pharmacological intervention versus placebo, 32 subjects would enable a difference of 38 mm(3) to be detected with a significance level of 5% with 80% power. CONCLUSION: Volumetric analysis with carotid CMR in asymptomatic subjects using a 3D volume-selective FSE is time-efficient with good inter-study reproducibility, and is well suited for longitudinal studies of carotid atheroma with reasonable sample sizes.


Assuntos
Artéria Carótida Primitiva/anatomia & histologia , Artéria Carótida Interna/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Aterosclerose/diagnóstico , Doenças das Artérias Carótidas/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco
8.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 1415-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271959

RESUMO

The link between atherosclerosis and wall shear stress (WSS) has lead to considerable interest in the in vivo estimation of WSS. Both magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS) are capable of providing the anatomical and flow data required for subject-specific computational fluid dynamics (CFD) simulations. This study compares, for the first time, predicted 3D flow patterns based on black blood MRI and 3DUS. Velocity fields in the carotid arteries of nine subjects have been reconstructed, and the haemodynamic wall parameters WSS, oscillatory shear index (OSI), WSS gradients (WSSG) and angle gradients (WSSAG) were computed and compared. There was a good qualitative agreement between results derived from MRI and 3DUS, embodied by a strong linear correlation between the patched representations of the haemodynamic wall parameters. The root-mean-square error between haemodynamic wall parameters was comparable to the range of the expected variability of each imaging technique (WSS: 0.411 N/m; OSI: 0.048; temporal WSSG: 2.29 N/(s.m/sup 2/); spatial WSSG: 150 N/m/sup 3/; WSSAG: 87.6 rad/m). In conclusion, MRI and 3DUS are comparable techniques for combining with CFD in the carotid artery. The relatively high cost of MRI favour 3DUS to MRI for future haemodynamic studies of superficial arteries.

9.
Physiol Meas ; 25(6): 1495-509, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15712727

RESUMO

Atherosclerosis is a major cause of morbidity and mortality. Its apparent link with wall shear stress (WSS) has led to considerable interest in the in vivo estimation of WSS. Determining WSS by combining medical images with computational fluid dynamics (CFD) simulations can be performed both with magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). This study compares predicted 3D flow patterns based on black blood MRI and 3DUS. Velocity fields in the carotid arteries of nine subjects have been reconstructed, and the haemodynamic wall parameters WSS, oscillatory shear index (OSI), WSS gradients (WSSG) and angle gradients (WSSAG) were compared between the two imaging techniques. There was a good qualitative agreement between results derived from MRI and 3DUS (average correlation strength above 0.60). The root mean square error between haemodynamic wall parameters was comparable to the range of the expected variability of each imaging technique (WSS: 0.411 N m(-2); OSI: 0.048; temporal WSSG: 150 N s(-1) m(-2); spatial WSSG: 2.29 N m(-3); WSSAG: 87.6 rad m(-1)). In conclusion, MRI and 3DUS are capable of providing haemodynamic parameters when combined with CFD, and the predictions are in most cases qualitatively and quantitatively similar. The relatively high cost of MRI and continuing improvement in ultrasound favour US to MRI for future haemodynamic studies of superficial arteries.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Adulto , Artérias Carótidas/anatomia & histologia , Simulação por Computador , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Med Phys ; 30(12): 3251-61, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14713092

RESUMO

Image-based Computational Fluid Dynamics (CFD) has become a popular tool for the prediction of in vivo flow profiles and hemodynamic wall parameters. Currently, Magnetic Resonance Imaging (MRI) is most widely used for in vivo geometry acquisition. For superficial arteries such as the carotids and the femoral artery, three-dimensional (3-D) extravascular ultrasound (3-DUS) could be a cost-effective alternative to MRI. In this study, nine healthy subjects were scanned both with MRI and 3-DUS. The reconstructed carotid artery geometries for each subject were compared by evaluating cross-sectional areas, centerlines, and carotid nonplanarity. Lumen areas agreed very well between the two different acquisition techniques, whereas centerlines and nonplanarity parameters showed measurable disagreement, possibly due to the different neck and head positions adopted for 3-DUS versus MRI. With the current level of agreement achieved, 3-DUS has the potential to become an inexpensive and fast alternative to MRI for image-based CFD modeling of superficial arteries.


Assuntos
Anatomia Transversal/métodos , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
11.
Headache ; 39(9): 654-61, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11279961

RESUMO

OBJECTIVE: The goal of this study was to determine whether onset of an "ordinary" headache initiated self-protective behavior or self-regulation, as indexed by a reduction in effort expenditure. METHODS: A nonclinical sample was employed. The ambition and performance accuracy of a headache-developing group (n = 23) and a sex-matched, headache-free group (n = 23) was compared during a series of mental arithmetic problems. Embedded within the series of math problems was a task involving recall of a stressor previously found to induce headache in many subjects. RESULTS: Onset of mild head pain did not lead to effort conservation; instead, heightened ambition appeared to characterize the headache-developing participants before as well as after headache onset. Headache-developing subjects also displayed a performance accuracy deficit. CONCLUSIONS: The data suggest unusually ambitious, effortful task engagement may contribute to the onset of mild "ordinary" headache. This possibility requires further examination under other controlled conditions as well as in the natural environment.


Assuntos
Comportamento , Cefaleia/fisiopatologia , Cefaleia/psicologia , Adulto , Metabolismo Energético , Feminino , Humanos , Masculino , Análise e Desempenho de Tarefas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...