Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Int J Legal Med ; 2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-35945461

RESUMO

The use of tooth-colored composite resin materials in dentistry is increasing. As composite restorations appear similar to the natural tooth structure, their detection is becoming more challenging. The aim of this study was to compare five diagnostic methods for detection of dental restorations and to create reliable postmortem dental records for forensic purposes. A conventional examination method without a direct light source (CONV), with a dental loupe light (DL), Galilean loupes with a direct light source (GDL), a fluorescence-inducing device (FIT), and intraoral radiographs (RX) were compared. Dentists specializing in conservative dentistry or oral surgery and dentistry students participated. Regarding sensitivity, specificity, positive predictive value, and negative predictive value, FIT and RX showed significantly higher results than CONV, DL, and GDL. RX and FIT showed comparable results in identifying composite restorations but depending on their location. The combination of both methods may lead to even better results. In conclusion fluorescence-inducing devices show good results in identifying composite restorations and therefore should be considered as a standard tool in forensic examinations. Another advantage is their small size, low cost, and mobility. Good illumination and magnification devices are recommended to enhance performance during conventional examinations. Involving dentists specialized in conservative dentistry could contribute to dental identification.

2.
Eur J Orthod ; 44(5): 513-521, 2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-35366310

RESUMO

BACKGROUND/OBJECTIVES: The aim of this study was to evaluate large field of view (FoV) subjective image quality of three cone-beam computed tomography (CBCT) machines to assess the threshold for reliable diagnostic perceptibility when lowering exposure settings. MATERIALS AND METHODS: One entire cadaver's head was scanned using three CBCT scanners. The largest available FoV of each device, imaging orthodontic relevant structures, was applied. CBCT datasets with different image quality based on standard to minimum scanning parameters were acquired. Five dentists evaluated the visibility of selected anatomical structures of the upper and lower jaw using a 5-point rating scale. RESULTS: Image quality depends on parameters such as a minimum voxel size of 0.2 to 0.4mm or a minimum of 4mA. A reduction in number of images (scanning protocol) reduces image quality. Visualization of different anatomical structures for orthodontic treatment planning requires distinct scanning protocols to support adequate perception of these structures. LIMITATIONS: This study does not account for the evaluation of paediatric anatomical structures due to the availability of cadaver's head. CONCLUSIONS: CBCT scans performed for orthodontic purposes using a large FoV with reduced parameters (400 µm, 2 to 4 mA and low dose protocols) are acceptable for visualization of large anatomical structures. Further lowering these parameters will not be sufficient to view small anatomical structures. Orthodontic indications will have to define specific anatomical structures to choose adequate scanning protocols to reduce dose and ensure reliable diagnostic visibility.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Cadáver , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Cabeça/diagnóstico por imagem , Humanos , Mandíbula/diagnóstico por imagem , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos
3.
J Clin Periodontol ; 47(7): 816-824, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32324295

RESUMO

BACKGROUND: To investigate the impact of scanning parameter in cone-beam computed tomography (CBCT) images on accuracy and confidence with measurements of furcation involvement (FI) in maxillary molars. MATERIAL AND METHODS: Six half cadaver heads with present maxillary molars (n = 10) were available. CBCT scans with the fixed-parameter field of view (4 × 4 cm, 12 × 17 cm) amperage and voltage (4 mA, 90 kV) and with varying scan modes (SM), that is images/scan (IS), voxel sizes (VZ) and rotation (R), were performed using one CBCT apparatus. The images were analysed by two calibrated investigators. Horizontal FI's were measured in mm or a "through and through" destruction (FI degree III) was recorded. Each rater scored the FI measurements performed in each scan as "confident" or as "not confident". Data were statistically analysed using chi-square tests. RESULTS: The agreement between CBCT FI measurements and intra-surgical FI measurements varied according to SM (SM HiSp 180°, 0.08: kappa 0.538, CI; 95%: 0.362-0.714; SM Std. 360°, 0.25: kappa 0.698, CI; 95%: 0.534-0.861). The number of measurements scored as "confident" varied according to SM (SM Std. 360°, 0.08:52 out of 60 measurements; SM Std. 360°, 0.25:16 out of 60 measurements; p < .001). CONCLUSIONS: SM of CBCT significantly affect the confidence with FI measurements in maxillary molars.


Assuntos
Defeitos da Furca , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Defeitos da Furca/diagnóstico por imagem , Humanos , Dente Molar/diagnóstico por imagem
4.
J Contemp Dent Pract ; 19(6): 704-711, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29959300

RESUMO

AIM: To investigate the influence of the radiographic modalities panoramic radiography (PR) and cone beam computed tomography (CBCT) on selection of implant length and diameter. MATERIALS AND METHODS: Potential implant sites (59 sites, 40 patients) with available PRs and CBCTs were selected from the databases of two University dental schools. Six experienced clinicians were asked to select the appropriate implant length and diameter based on PR and CBCT. Results were compared with the actual surgical procedure and intra- /interrater agreement was calculated using Cohen's kappa. RESULTS: On average, greater implant length was more often planned based on PR (24.2 vs 8.8% with CBCT), while wider implants were generally more frequently planned based on CBCTs (19.9 vs 29.7% with PR). Implant treatment planning based on PR and on CBCT images was equal in 50 to 67%. Compared with the actual surgery, CBCT revealed a higher agreement (46% for implant length), while for PR, 34.4% equal implant length was observed. CONCLUSION: The radiographic modality used for implant treatment planning affects implant selection. CLINICAL SIGNIFICANCE: The CBCT scans are advantageous for choosing the appropriate implant dimension. Caution should be exercised when selecting implant length planned from PR.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Imageamento Tridimensional , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Dentária , Radiografia Panorâmica , Adulto Jovem
5.
Clin Oral Implants Res ; 27(8): 1010-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26227397

RESUMO

OBJECTIVES: To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. MATERIAL AND METHODS: Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. RESULTS: Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or panoramic radiographs coincided for 55-72% of the cases. A trend to a more invasive augmentation procedure was seen when planning was based on CBCT. Panoramic radiography revealed 57-63% (lateral) vs. 67% (vertical augmentation) congruent plans in agreement with surgery. Among the dissenting sites, there was a trend toward less invasive planning for lateral augmentation with panoramic radiographs, while vertical augmentation requirements were more frequently more invasive when based on CBCT. CONCLUSIONS: Vertical augmentation requirements can be adequately determined from panoramic radiographs. In difficult cases with a deficient lateral alveolar bone, the augmentation schedule may better be evaluated from CBCT to avoid underestimation, which occurs more frequently when based on panoramic radiographs only. However, overall, radiographic interpretation and diagnostic thinking accuracy seem to be mainly depending on the opinion of observers.


Assuntos
Aumento do Rebordo Alveolar , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários para Um Único Dente , Radiografia Panorâmica , Adulto , Idoso , Implantação Dentária Endóssea , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Retrospectivos , Adulto Jovem
6.
Clin Oral Implants Res ; 25(12): 1352-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24147971

RESUMO

AIM: The aim of this pilot study was to analyze the interfurcal bone height in relation to the possible need for subsequent sinus floor elevation in patients with advanced periodontitis and furcation involvement of first and/or second maxillary molars. MATERIAL AND METHODS: Seventeen dentate patients, who received cone beam computed tomography (CBCT) for detailed preoperative diagnosis and planning of surgical interventions at periodontally involved maxillary molars (17 first and 15 second molars), were consecutively recruited for the study. The minimal bone height in the interfurcal region was measured from CBCT and related to furcation involvement, residual bone above the root tips, and the clinical probing pocket depth (PPD). RESULTS: The minimal interfurcal bone height measured 4.1 ± 2.6 mm on average with 75% of maxillary molars having ≤ 6 mm and almost 60% having only ≤ 4 mm bone height left below the sinus floor. A higher risk for reduced interfurcal bone height of ≤ 4 mm was given when residual PPD of ≥ 6 mm was remaining at two or more tooth sites (OR 0.10; 0.11). CONCLUSIONS: The majority of periodontally involved maxillary molars had a substantially reduced interfurcal bone height, particularly with at least two sites with residual PPD ≥ 6 mm. This was a predictor for a subsequent need for sinus floor elevation when tooth replacement with a dental implant is desired.


Assuntos
Implantes Dentários , Defeitos da Furca/complicações , Doenças Maxilares/complicações , Dente Molar/patologia , Levantamento do Assoalho do Seio Maxilar/métodos , Raiz Dentária/patologia , Perda do Osso Alveolar/complicações , Perda do Osso Alveolar/diagnóstico por imagem , Periodontite Crônica/complicações , Periodontite Crônica/diagnóstico por imagem , Estudos de Coortes , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Previsões , Defeitos da Furca/diagnóstico por imagem , Humanos , Masculino , Doenças Maxilares/cirurgia , Pessoa de Meia-Idade , Perda da Inserção Periodontal/complicações , Bolsa Periodontal/complicações , Periodontite/complicações , Periodontite/diagnóstico por imagem , Projetos Piloto , Fatores de Risco
7.
J Int Acad Periodontol ; 15(3): 75-82, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24079099

RESUMO

OBJECTIVE: The aim was to assess the thickness of Schneiderian membranes (SM) in patients with advanced periodontal disease. METHODS: 17 dentate patients (DG) scheduled for periodontal surgery on maxillary molars were consecutively recruited and cone beam computed tomographies performed for preoperative diagnosis. Twenty-one patients (EG) requiring cone beam computed tomography-based planning of implant placement in the edentulous posterior maxilla served as controls. RESULTS: Schneiderian membrane thickness measured from cone beam computed tomography was significantly greater in the dentate group compared to the edentulous group, both in the first (p = 0.028) and second (p < 0.001) molar position. In the dentate group, clinical signs of periodontal destruction (increased probing pocket depth or furcation involvement) were not associated with Schneiderian membrane thickness. Additional findings, such as periapical lesions (p = 0.008), and the distance between root tips and maxillary sinus revealed a significant association (p = 0.036) with Schneiderian membrane thickness. CONCLUSION: In molar regions with periodontal destruction, Schneiderian membrane thickening occurred, particularly in combination with small bone layers above the root tips or periapical lesions.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Seio Maxilar/diagnóstico por imagem , Mucosa Nasal/diagnóstico por imagem , Doenças Periodontais/complicações , Idoso , Processo Alveolar/diagnóstico por imagem , Dente Pré-Molar/diagnóstico por imagem , Implantes Dentários , Feminino , Defeitos da Furca/complicações , Humanos , Processamento de Imagem Assistida por Computador/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Parcialmente Edêntula/diagnóstico por imagem , Masculino , Maxila/diagnóstico por imagem , Seio Maxilar/patologia , Pessoa de Meia-Idade , Dente Molar/diagnóstico por imagem , Mucosa Nasal/patologia , Planejamento de Assistência ao Paciente , Doenças Periapicais/complicações , Perda da Inserção Periodontal/complicações , Doenças Periodontais/cirurgia , Bolsa Periodontal/complicações , Radiografia Interproximal , Ápice Dentário/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...