Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Clin Nucl Med ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38914016

RESUMO

PURPOSE: The aim of this study was to assess the association among toxicity, dosimetry of organs-at-risk, and disease progression in patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs) treated with 177Lu-DOTATATE. PATIENTS AND METHODS: Thirty-seven patients with GEP-NETs underwent 177Lu-DOTATATE peptide receptor radionuclide therapy (PRRT) in a single-arm, prospective, phase 2 study, where patients were followed up with blood tests, isotopic glomerular filtration rate (iGFR), and imaging examinations (CT/MRI and PET) every 6 months until disease progression. Adverse events (AEs) graded per CTCAEv4.03 and occurring during treatment were collected and followed up until resolution. Dosimetry, including biologically effective doses (BEDs) to kidneys, BED to bone marrow, and absorbed dose (AD) to spleen, was performed after each PRRT cycle. Statistical analyses explored associations among dosimetry, toxicity, and patient progression free-survival. RESULTS: The most common AEs were anemia and lymphopenia (65%), followed by thrombocytopenia and fatigue (each 51%), alopecia (46%), and nausea (41%). The most common grade ≥3 AE was lymphopenia (43%). There was no grade ≥3 nephrotoxicity. The median iGFR % decrease was 11% (P < 0.001), at a median follow-up of 23 months. iGFR %decrease and renal BED did not correlate (Spearman ρ = -0.09). Similarly, no significant association was found between bone marrow BED or spleen AD and the grades of hematological toxicities. We observed no association between progression free-survival and either the decline of renal function or the occurrence of hematological toxicities during PRRT. CONCLUSIONS: This study confirms the safety profile of 177Lu-DOTATATE PRRT in patients with GEP-NETs irrespective of the dosimetry of organs at risk. Kidney, bone marrow, and spleen dosimetry measures were not associated with renal or hematological toxicity.

2.
J Nucl Med ; 65(2): 236-244, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164576

RESUMO

Our objective was to predict the outcome of peptide receptor radionuclide therapy (PRRT) using multimodality imaging and tumor dosimetry on gastroenteropancreatic neuroendocrine tumor (GEP-NET) lesions and patients. Methods: This prospective study included patients with progressive GEP-NETs. Treatment consisted of 4 cycles of 7.4 GBq of 177Lu-DOTATATE. Imaging parameters were measured on 68Ga-DOTATATE PET/CT (SUVmax/mean, somatostatin receptor [SSTR] tumor volume [TV], total lesion SSTR expression, and tumor-to-blood and tumor-to-spleen ratios), 18F-FDG PET/CT (SUVmax/mean, metabolically active TV, and total lesion glycolysis), and diffusion-weighted MRI (apparent diffusion coefficient) in a maximum of 5 target lesions per patient at approximately 10 wk after each injection. Tumor dosimetry was performed using SPECT/CT at 3 time points for every cycle. Baseline imaging parameters, their relative changes after PRRT cycle 1 (C1), and the tumor-absorbed dose at C1 were correlated with lesion morphologic outcome. The average values of the imaging parameters and the minimal, maximal, and mean C1 tumor-absorbed dose in each patient were tested for association with progression-free survival (PFS) and best objective response (RECIST 1.1). Results: In the 37 patients, the median PFS was 28 mo. Eleven of the 37 (30%) achieved a partial response (RECIST 1.1). After a median follow-up of 57 mo, the median time to lesion progression had not been reached in 84 morphologically evaluable lesions, with only 12 (14%) progressing (size increase ≥ 20% from baseline). Patients receiving a minimal C1 dose of 35 Gy in all target lesions exhibited a significantly longer PFS (48.1 vs. 26.2 mo; hazard ratio, 0.37; 95% CI, 0.17-0.82; P = 0.02). Volumetric 68Ga-DOTATATE PET parameters correlated with lesion and patient outcome: patients with an SSTR TV decrease of more than 10% after C1 had a longer PFS (51.3 vs. 22.8 mo; hazard ratio, 0.35; 95% CI, 0.16-0.75; P = 0.003). There was no statistical evidence of an association between other dosimetric or imaging parameters and the lesion or patient outcome. Conclusion: Minimal tumor-absorbed dose at C1 is predictive of outcome in patients with GEP-NETs treated with PRRT, providing a basis for personalized dosimetry-guided treatment strategies. An SSTR TV decrease after C1 could be used for early therapy response assessment as a predictor of PRRT outcome.


Assuntos
Neoplasias Intestinais , Tumores Neuroendócrinos , Compostos Organometálicos , Neoplasias Pancreáticas , Tomografia por Emissão de Pósitrons , Cintilografia , Neoplasias Gástricas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/tratamento farmacológico , Estudos Prospectivos , Radioisótopos de Gálio , Resultado do Tratamento , Compostos Organometálicos/uso terapêutico , Receptores de Somatostatina/metabolismo , Octreotida/uso terapêutico
3.
Med Phys ; 51(1): 522-532, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37712869

RESUMO

BACKGROUND: Radiopharmaceutical therapy (RPT) is an increasingly adopted modality for treating cancer. There is evidence that the optimization of the treatment based on dosimetry can improve outcomes. However, standardization of the clinical dosimetry workflow still represents a major effort. Among the many sources of variability, the impact of using different Dose Voxel Kernels (DVKs) to generate absorbed dose (AD) maps by convolution with the time-integrated activity (TIA) distribution has not been systematically investigated. PURPOSE: This study aims to compare DVKs and assess the differences in the ADs when convolving the same TIA map with different DVKs. METHODS: DVKs of 3 × 3 × 3 mm3 sampling-nine for 177 Lu, nine for 90 Y-were selected from those most used in commercial/free software or presented in prior publications. For each voxel within a 11 × 11 × 11 matrix, the coefficient of variation (CoV) and the percentage difference between maximum and minimum values (% maximum difference) were calculated. The total absorbed dose per decay (SUM), calculated as the sum of all the voxel values in each kernel, was also compared. Publicly available quantitative SPECT images for two patients treated with 177 Lu-DOTATATE and PET images for two patients treated with 90 Y-microspheres were used, including organs at risk (177 Lu: kidneys; 90 Y: liver and healthy liver) and tumors' segmentations. For each patient, the mean AD to the volumes of interest (VOIs) was calculated using the different DVKs, the same TIA map and the same software tool for dose convolution, thereby focusing on the DVK impact. For each VOI, the % maximum difference of the mean AD between maximum and minimum values was computed. RESULTS: The CoV (% maximum difference) in voxels of normalized coordinates [0,0,0], [0,1,0], and [0,1,1] were 5%(21%), 9%(35%), and 10%(46%) for the 177 Lu DVKs. For the case of 90 Y, these values were 2%(9%), 4%(14%), and 4%(16%). The CoV (% maximum difference) for SUM was 9%(33%) for 177 Lu, and 4%(15%) for 90 Y. The variability of the mean tumor and organ AD was up to 19% and 15% in 177 Lu-DOTATATE and 90 Y-microspheres patients, respectively. CONCLUSIONS: This study showed a considerable AD variability due exclusively to the use of different DVKs. A concerted effort by the scientific community would contribute to decrease these discrepancies, strengthening the consistency of AD calculation in RPT.


Assuntos
Radiometria , Compostos Radiofarmacêuticos , Humanos , Fígado , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Software
4.
EJNMMI Phys ; 10(1): 64, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37853247

RESUMO

BACKGROUND: Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. METHODS: A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. RESULTS: The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS: Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.

5.
J Pers Med ; 12(2)2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35207693

RESUMO

Targeted radiation therapy (TRT) is a strategy increasingly adopted for the treatment of different types of cancer. The urge for optimization, as stated by the European Council Directive (2013/59/EURATOM), requires the implementation of a personalized dosimetric approach, similar to what already happens in external beam radiation therapy (EBRT). The purpose of this paper is to provide a thorough introduction to the field of personalized dosimetry in TRT, explaining its rationale in the context of optimization and describing the currently available methodologies. After listing the main therapies currently employed, the clinical workflow for the absorbed dose calculation is described, based on works of the most experienced authors in the literature and recent guidelines. Moreover, the widespread software packages for internal dosimetry are presented and critical aspects discussed. Overall, a selection of the most important and recent articles about this topic is provided.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...