Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
BMC Prim Care ; 25(1): 7, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166641

RESUMO

BACKGROUND: Conducting effective and translational research can be challenging and few trials undertake formal reflection exercises and disseminate learnings from them. Following completion of our multicentre randomised controlled trial, which was impacted by the COVID-19 pandemic, we sought to reflect on our experiences and share our thoughts on challenges, lessons learned, and recommendations for researchers undertaking or considering research in primary care. METHODS: Researchers involved in the Prediction of Undiagnosed atriaL fibrillation using a machinE learning AlgorIthm (PULsE-AI) trial, conducted in England from June 2019 to February 2021 were invited to participate in a qualitative reflection exercise. Members of the Trial Steering Committee (TSC) were invited to attend a semi-structured focus group session, Principal Investigators and their research teams at practices involved in the trial were invited to participate in a semi-structured interview. Following transcription, reflexive thematic analysis was undertaken based on pre-specified themes of recruitment, challenges, lessons learned, and recommendations that formed the structure of the focus group/interview sessions, whilst also allowing the exploration of new themes that emerged from the data. RESULTS: Eight of 14 members of the TSC, and one of six practices involved in the trial participated in the reflection exercise. Recruitment was highlighted as a major challenge encountered by trial researchers, even prior to disruption due to the COVID-19 pandemic. Researchers also commented on themes such as the need to consider incentivisation, and challenges associated with using technology in trials, especially in older age groups. CONCLUSIONS: Undertaking a formal reflection exercise following the completion of the PULsE-AI trial enabled us to review experiences encountered whilst undertaking a prospective randomised trial in primary care. In sharing our learnings, we hope to support other clinicians undertaking research in primary care to ensure that future trials are of optimal value for furthering knowledge, streamlining pathways, and benefitting patients.


Assuntos
COVID-19 , Pandemias , Humanos , Idoso , Estudos Prospectivos , Atenção Primária à Saúde , Inteligência Artificial , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Europace ; 25(3): 863-872, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36576323

RESUMO

AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Hospitais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
3.
J Med Econ ; 25(1): 974-983, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35834373

RESUMO

OBJECTIVE: The PULsE-AI trial sought to determine the effectiveness of a screening strategy that included a machine learning risk prediction algorithm in conjunction with diagnostic testing for identification of undiagnosed atrial fibrillation (AF) in primary care. This study aimed to evaluate the cost-effectiveness of implementing the screening strategy in a real-world setting. METHODS: Data from the PULsE-AI trial - a prospective, randomized, controlled trial conducted across six general practices in England from June 2019 to February 2021 - were used to inform a cost-effectiveness analysis that included a hybrid screening decision tree and Markov AF disease progression model. Model outcomes were reported at both individual- and population-level (estimated UK population ≥30 years of age at high-risk of undiagnosed AF) and included number of patients screened, number of AF cases identified, mean total and incremental costs (screening, events, treatment), quality-adjusted-life-years (QALYs), and incremental cost-effectiveness ratio (ICER). RESULTS: The screening strategy was estimated to result in 45,493 new diagnoses of AF across the high-risk population in the UK (3.3 million), and an estimated additional 14,004 lifetime diagnoses compared with routine care only. Per-patient costs for high-risk individuals who underwent the screening strategy were estimated at £1,985 (vs £1,888 for individuals receiving routine care only). At a population-level, the screening strategy was associated with a cost increase of approximately £322 million and an increase of 81,000 QALYs. The screening strategy demonstrated cost-effectiveness versus routine care only at an accepted ICER threshold of £20,000 per QALY-gained, with an ICER of £3,994/QALY. CONCLUSIONS: Compared with routine care only, it is cost-effective to target individuals at high risk of undiagnosed AF, through an AF risk prediction algorithm, who should then undergo diagnostic testing. This AF risk prediction algorithm can reduce the number of patients needed to be screened to identify undiagnosed AF, thus alleviating primary care burden.


Assuntos
Fibrilação Atrial , Algoritmos , Inteligência Artificial , Fibrilação Atrial/complicações , Análise Custo-Benefício , Eletrocardiografia , Humanos , Aprendizado de Máquina , Programas de Rastreamento , Atenção Primária à Saúde , Estudos Prospectivos , Anos de Vida Ajustados por Qualidade de Vida
4.
Europace ; 23(2): 305-312, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33083839

RESUMO

AIMS: Rate adaptation of the action potential ensures spatial heterogeneities in conduction across the myocardium are minimized at different heart rates providing a protective mechanism against ventricular fibrillation (VF) and sudden cardiac death (SCD), which can be quantified by the ventricular conduction stability (V-CoS) test previously described. We tested the hypothesis that patients with a history of aborted SCD due to an underlying channelopathy or cardiomyopathy have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Sixty individuals, with (n = 28) and without (n = 32) previous aborted-SCD event underwent electro-cardiographic imaging recordings following exercise treadmill test. These included 25 Brugada syndrome, 13 hypertrophic cardiomyopathy, 12 idiopathic VF, and 10 healthy controls. Data were inputted into the V-CoS programme to calculate a V-CoS score that indicate the percentage of ventricle that showed no significant change in ventricular activation, with a lower score indicating the development of greater conduction heterogeneity. The SCD group, compared to those without, had a lower median (interquartile range) V-CoS score at peak exertion [92.8% (89.8-96.3%) vs. 97.3% (94.9-99.1%); P < 0.01] and 2 min into recovery [95.2% (91.1-97.2%) vs. 98.9% (96.9-99.5%); P < 0.01]. No significant difference was observable later into recovery at 5 or 10 min. Using the lowest median V-CoS scores obtained during the entire recovery period post-exertion, SCD survivors had a significantly lower score than those without for each of the different underlying aetiologies. CONCLUSION: Data from this pilot study demonstrate the potential use of this technique in risk stratification for the inherited cardiac conditions.


Assuntos
Morte Súbita Cardíaca , Fibrilação Ventricular , Morte Súbita Cardíaca/etiologia , Coração , Humanos , Projetos Piloto , Fatores de Risco , Sobreviventes , Fibrilação Ventricular/diagnóstico
5.
Contemp Clin Trials ; 99: 106191, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33091585

RESUMO

Atrial fibrillation (AF) is associated with an increased risk of stroke, enhanced stroke severity, and other comorbidities. However, AF is often asymptomatic, and frequently remains undiagnosed until complications occur. Current screening approaches for AF lack either cost-effectiveness or diagnostic sensitivity; thus, there is interest in tools that could be used for population screening. An AF risk prediction algorithm, developed using machine learning from a UK dataset of 2,994,837 patients, was found to be more effective than existing models at identifying patients at risk of AF. Therefore, the aim of the trial is to assess the effectiveness of this risk prediction algorithm combined with diagnostic testing for the identification of AF in a real-world primary care setting. Eligible participants (aged ≥30 years and without an existing AF diagnosis) registered at participating UK general practices will be randomised into intervention and control arms. Intervention arm participants identified at highest risk of developing AF (algorithm risk score ≥ 7.4%) will be invited for a 12­lead electrocardiogram (ECG) followed by two-weeks of home-based ECG monitoring with a KardiaMobile device. Control arm participants will be used for comparison and will be managed routinely. The primary outcome is the number of AF diagnoses in the intervention arm compared with the control arm during the research window. If the trial is successful, there is potential for the risk prediction algorithm to be implemented throughout primary care for narrowing the population considered at highest risk for AF who could benefit from more intensive screening for AF. Trial Registration: NCT04045639.


Assuntos
Fibrilação Atrial , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia , Frequência Cardíaca , Humanos , Aprendizado de Máquina , Programas de Rastreamento , Ensaios Clínicos Controlados Aleatórios como Assunto
6.
Heart Rhythm ; 16(9): 1357-1367, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31170484

RESUMO

BACKGROUND: Bipolar electrogram voltage during sinus rhythm (VSR) has been used as a surrogate for atrial fibrosis in guiding catheter ablation of persistent atrial fibrillation (AF), but the fixed rate and wavefront characteristics present during sinus rhythm may not accurately reflect underlying functional vulnerabilities responsible for AF maintenance. OBJECTIVE: The purpose of this study was determine whether, given adequate temporal sampling, the spatial distribution of mean AF voltage (VmAF) better correlates with delayed-enhancement magnetic resonance imaging (MRI-DE)-detected atrial fibrosis than VSR. METHODS: AF was mapped (8 seconds) during index ablation for persistent AF (20 patients) using a 20-pole catheter (660 ± 28 points/map). After cardioversion, VSR was mapped (557 ± 326 points/map). Electroanatomic and MRI-DE maps were co-registered in 14 patients. RESULTS: The time course of VmAF was assessed from 1-40 AF cycles (∼8 seconds) at 1113 locations. VmAF stabilized with sampling >4 seconds (mean voltage error 0.05 mV). Paired point analysis of VmAF from segments acquired 30 seconds apart (3667 sites; 15 patients) showed strong correlation (r = 0.95; P <.001). Delayed enhancement (DE) was assessed across the posterior left atrial (LA) wall, occupying 33% ± 13%. VmAF distributions were (median [IQR]) 0.21 [0.14-0.35] mV in DE vs 0.52 [0.34-0.77] mV in non-DE regions. VSR distributions were 1.34 [0.65-2.48] mV in DE vs 2.37 [1.27-3.97] mV in non-DE. VmAF threshold of 0.35 mV yielded sensitivity of 75% and specificity of 79% in detecting MRI-DE compared with 63% and 67%, respectively, for VSR (1.8-mV threshold). CONCLUSION: The correlation between low-voltage and posterior LA MRI-DE is significantly improved when acquired during AF vs sinus rhythm. With adequate sampling, mean AF voltage is a reproducible marker reflecting the functional response to the underlying persistent AF substrate.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Correlação de Dados , Feminino , Fibrose/complicações , Fibrose/diagnóstico , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
7.
JACC Clin Electrophysiol ; 5(6): 705-715, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31221358

RESUMO

OBJECTIVES: This study sought to test specialized processing of laser Doppler signals for discriminating ventricular fibrillation (VF) from common causes of inappropriate therapies. BACKGROUND: Inappropriate implantable cardioverter-defibrillator (ICD) therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, implemented to assist automated diagnosis of VF, sometimes mistake artifacts and random noise for perfusion, which could lead to shocks being inappropriately withheld. METHODS: The study tested a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring as a method for assessing circulatory status. Fifty patients undergoing VF induction during ICD implantation were recruited. Noninvasive laser Doppler and continuous electrograms were recorded during both sinus rhythm and VF. Two additional scenarios that might have led to inappropriate shocks were simulated for each patient: ventricular lead fracture and T-wave oversensing. The laser Doppler was analyzed using 3 methods for reducing noise: 1) running mean; 2) oscillatory height; and 3) a novel quantification of electromechanical coupling which gates laser Doppler relative to electrograms. In addition, the algorithm was tested during exercise-induced sinus tachycardia. RESULTS: Only the electromechanical coupling algorithm found a clear perfusion cut off between sinus rhythm and VF (sensitivity and specificity of 100%). Sensitivity and specificity remained at 100% during simulated lead fracture and electrogram oversensing. (Area under the curve running mean: 0.91; oscillatory height: 0.86; electromechanical coupling: 1.00). Sinus tachycardia did not cause false positive results. CONCLUSIONS: Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artifacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrocardiografia , Falha de Equipamento , Fluxometria por Laser-Doppler , Processamento de Sinais Assistido por Computador , Fibrilação Ventricular/diagnóstico , Idoso , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Taquicardia Sinusal
8.
JAMA ; 321(13): 1261-1274, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30874766

RESUMO

Importance: Catheter ablation is effective in restoring sinus rhythm in atrial fibrillation (AF), but its effects on long-term mortality and stroke risk are uncertain. Objective: To determine whether catheter ablation is more effective than conventional medical therapy for improving outcomes in AF. Design, Setting, and Participants: The Catheter Ablation vs Antiarrhythmic Drug Therapy for Atrial Fibrillation trial is an investigator-initiated, open-label, multicenter, randomized trial involving 126 centers in 10 countries. A total of 2204 symptomatic patients with AF aged 65 years and older or younger than 65 years with 1 or more risk factors for stroke were enrolled from November 2009 to April 2016, with follow-up through December 31, 2017. Interventions: The catheter ablation group (n = 1108) underwent pulmonary vein isolation, with additional ablative procedures at the discretion of site investigators. The drug therapy group (n = 1096) received standard rhythm and/or rate control drugs guided by contemporaneous guidelines. Main Outcomes and Measures: The primary end point was a composite of death, disabling stroke, serious bleeding, or cardiac arrest. Among 13 prespecified secondary end points, 3 are included in this report: all-cause mortality; total mortality or cardiovascular hospitalization; and AF recurrence. Results: Of the 2204 patients randomized (median age, 68 years; 37.2% female; 42.9% had paroxysmal AF and 57.1% had persistent AF), 89.3% completed the trial. Of the patients assigned to catheter ablation, 1006 (90.8%) underwent the procedure. Of the patients assigned to drug therapy, 301 (27.5%) ultimately received catheter ablation. In the intention-to-treat analysis, over a median follow-up of 48.5 months, the primary end point occurred in 8.0% (n = 89) of patients in the ablation group vs 9.2% (n = 101) of patients in the drug therapy group (hazard ratio [HR], 0.86 [95% CI, 0.65-1.15]; P = .30). Among the secondary end points, outcomes in the ablation group vs the drug therapy group, respectively, were 5.2% vs 6.1% for all-cause mortality (HR, 0.85 [95% CI, 0.60-1.21]; P = .38), 51.7% vs 58.1% for death or cardiovascular hospitalization (HR, 0.83 [95% CI, 0.74-0.93]; P = .001), and 49.9% vs 69.5% for AF recurrence (HR, 0.52 [95% CI, 0.45-0.60]; P < .001). Conclusions and Relevance: Among patients with AF, the strategy of catheter ablation, compared with medical therapy, did not significantly reduce the primary composite end point of death, disabling stroke, serious bleeding, or cardiac arrest. However, the estimated treatment effect of catheter ablation was affected by lower-than-expected event rates and treatment crossovers, which should be considered in interpreting the results of the trial. Trial Registration: ClinicalTrials.gov Identifier: NCT00911508.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Parada Cardíaca/prevenção & controle , Hemorragia/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Feminino , Parada Cardíaca/etiologia , Hemorragia/etiologia , Hospitalização/estatística & dados numéricos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/etiologia
9.
J Am Coll Cardiol ; 72(24): 3112-3122, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30545450

RESUMO

BACKGROUND: His bundle pacing is a new method for delivering cardiac resynchronization therapy (CRT). OBJECTIVES: The authors performed a head-to-head, high-precision, acute crossover comparison between His bundle pacing and conventional biventricular CRT, measuring effects on ventricular activation and acute hemodynamic function. METHODS: Patients with heart failure and left bundle branch block referred for conventional biventricular CRT were recruited. Using noninvasive epicardial electrocardiographic imaging, the authors identified patients in whom His bundle pacing shortened left ventricular activation time. In these patients, the authors compared the hemodynamic effects of His bundle pacing against biventricular pacing using a high-multiple repeated alternation protocol to minimize the effect of noise, as well as comparing effects on ventricular activation. RESULTS: In 18 of 23 patients, left ventricular activation time was significantly shortened by His bundle pacing. Seventeen patients had a complete electromechanical dataset. In them, His bundle pacing was more effective at delivering ventricular resynchronization than biventricular pacing: greater reduction in QRS duration (-18.6 ms; 95% confidence interval [CI]: -31.6 to -5.7 ms; p = 0.007), left ventricular activation time (-26 ms; 95% CI: -41 to -21 ms; p = 0.002), and left ventricular dyssynchrony index (-11.2 ms; 95% CI: -16.8 to -5.6 ms; p < 0.001). His bundle pacing also produced a greater acute hemodynamic response (4.6 mm Hg; 95% CI: 0.2 to 9.1 mm Hg; p = 0.04). The incremental activation time reduction with His bundle pacing over biventricular pacing correlated with the incremental hemodynamic improvement with His bundle pacing over biventricular pacing (R = 0.70; p = 0.04). CONCLUSIONS: His resynchronization delivers better ventricular resynchronization, and greater improvement in hemodynamic parameters, than biventricular pacing.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo/complicações , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/complicações , Idoso , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 29(3): 404-411, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29341322

RESUMO

BACKGROUND: Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. METHODS: We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. RESULTS: Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). CONCLUSIONS: The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
11.
Am J Cardiol ; 121(3): 349-355, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29203036

RESUMO

Implantable cardiodefibrillators (ICDs) have proven benefit in preventing sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HC), making risk stratification essential. Data on the predictive accuracy on the European Society of Cardiology (ESC) risk scoring system have been conflicting. We independently evaluated the ESC risk scoring system in our cohort of patients with HC from a large tertiary center and compared this with previous guidance by the American College of Cardiology Foundation and Heart Association (ACCF/AHA). Risk factor profiles, 5-year SCD risk estimates, and ICD recommendations, as defined by the ACCF/AHA and ESC guidelines, were retrospectively ascertained for 288 HC patients with and without SCD or equivalent events at our center. In the SCD group (n = 14), a significantly higher proportion of patients would not have met the criteria for an ICD implant using the ESC scoring algorithm compared with ACCF/AHA guidance (43% vs 7%, p = 0.029). In those without SCD events (n = 274), a larger proportion of individuals not requiring an ICD was identified using the ESC risk score model compared with the ACCF/AHA model (82% vs 57%; p < 0.0001). Based on risk stratification criteria alone, 5 more individuals with a previously aborted SCD event would not have received an ICD with the ESC risk model compared with the ACCF/AHA risk model. In conclusion, we found that the current ESC scoring system potentially leaves more high-risk patients unprotected from sudden death in our cohort of patients.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Medição de Risco/métodos , Adulto , American Heart Association , Europa (Continente) , Feminino , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Sociedades Médicas , Estados Unidos
12.
J Cardiovasc Electrophysiol ; 29(1): 115-126, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091329

RESUMO

BACKGROUND: Models of cardiac arrhythmogenesis predict that nonuniformity in repolarization and/or depolarization promotes ventricular fibrillation and is modulated by autonomic tone, but this is difficult to evaluate in patients. We hypothesize that such spatial heterogeneities would be detected by noninvasive ECG imaging (ECGi) in sudden cardiac death (SCD) survivors with structurally normal hearts under physiological stress. METHODS: ECGi was applied to 11 SCD survivors, 10 low-risk Brugada syndrome patients (BrS), and 10 controls undergoing exercise treadmill testing. ECGi provides whole heart activation maps and >1,200 unipolar electrograms over the ventricular surface from which global dispersion of activation recovery interval (ARI) and regional delay in conduction were determined. These were used as surrogates for spatial heterogeneities in repolarization and depolarization. Surface ECG markers of dispersion (QT and Tpeak-end intervals) were also calculated for all patients for comparison. RESULTS: Following exertion, the SCD group demonstrated the largest increase in ARI dispersion compared to BrS and control groups (13 ± 8 ms vs. 4 ± 7 ms vs. 4 ± 5 ms; P = 0.009), with baseline dispersion being similar in all groups. In comparison, surface ECG markers of dispersion of repolarization were unable to discriminate between the groups at baseline or following exertion. Spatial heterogeneities in conduction were also present following exercise but were not significantly different between SCD survivors and the other groups. CONCLUSION: Increased dispersion of repolarization is apparent during physiological stress in SCD survivors and is detectable with ECGi but not with standard ECG parameters. The electrophysiological substrate revealed by ECGi could be the basis of alternative risk-stratification techniques.


Assuntos
Potenciais de Ação , Mapeamento Potencial de Superfície Corporal , Morte Súbita Cardíaca/etiologia , Teste de Esforço , Exercício Físico , Sistema de Condução Cardíaco/fisiopatologia , Estresse Fisiológico , Fibrilação Ventricular/diagnóstico , Adulto , Idoso , Morte Súbita Cardíaca/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
16.
Artigo em Inglês | MEDLINE | ID: mdl-29038102

RESUMO

BACKGROUND: The substrate location and underlying electrophysiological mechanisms that contribute to the characteristic ECG pattern of Brugada syndrome (BrS) are still debated. Using noninvasive electrocardiographical imaging, we studied whole heart conduction and repolarization patterns during ajmaline challenge in BrS individuals. METHODS AND RESULTS: A total of 13 participants (mean age, 44±12 years; 8 men), 11 concealed patients with type I BrS and 2 healthy controls, underwent an ajmaline infusion with electrocardiographical imaging and ECG recordings. Electrocardiographical imaging activation recovery intervals and activation timings across the right ventricle (RV) body, outflow tract (RVOT), and left ventricle were calculated and analyzed at baseline and when type I BrS pattern manifested after ajmaline infusion. Peak J-ST point elevation was calculated from the surface ECG and compared with the electrocardiographical imaging-derived parameters at the same time point. After ajmaline infusion, the RVOT had the greatest increase in conduction delay (5.4±2.8 versus 2.0±2.8 versus 1.1±1.6 ms; P=0.007) and activation recovery intervals prolongation (69±32 versus 39±29 versus 21±12 ms; P=0.0005) compared with RV or left ventricle. In controls, there was minimal change in J-ST point elevation, conduction delay, or activation recovery intervals at all sites with ajmaline. In patients with BrS, conduction delay in RVOT, but not RV or left ventricle, correlated to the degree of J-ST point elevation (Pearson R, 0.81; P<0.001). No correlation was found between J-ST point elevation and activation recovery intervals prolongation in the RVOT, RV, or left ventricle. CONCLUSIONS: Magnitude of ST (J point) elevation in the type I BrS pattern is attributed to degree of conduction delay in the RVOT and not prolongation in repolarization time.


Assuntos
Potenciais de Ação , Mapeamento Potencial de Superfície Corporal , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Potenciais de Ação/efeitos dos fármacos , Adulto , Ajmalina/administração & dosagem , Antiarrítmicos/administração & dosagem , Síndrome de Brugada/fisiopatologia , Estudos de Casos e Controles , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Período Refratário Eletrofisiológico , Processamento de Sinais Assistido por Computador , Fatores de Tempo
17.
J Cardiovasc Electrophysiol ; 28(12): 1445-1453, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28833757

RESUMO

INTRODUCTION: We hypothesized that very high-density mapping of typical atrial flutter (AFL) would facilitate a more complete understanding of its circuit. Such very high-density mapping was performed with the RhythmiaTM (Boston Scientific) mapping system using its 64 electrode basket catheter. METHODS AND RESULTS: Data were acquired from 13 patients in AFL. Functional anatomy of the right atrium (RA) was readily identified during mapping including the Crista Terminalis and Eustachian ridge. The leading edge of the activation wavefront was identified without interruption and its conduction velocity (CV) was calculated. CV was not different at the cavotricuspid isthmus (CTI) compared to the remainder of the RA (1.02 vs. 1.03 m/s, P = 0.93). The sawtooth pattern of the surface electrocardiogram (EKG) flutter waves was compared to the position of the dominant wavefront. The downslope of the surface EKG flutter waves represented on average 73% ± 9% of the total flutter cycle length. During the downslope, the activation wavefront traveled significantly further than during the upslope (182 ± 21 milliseconds vs. 68 ± 29 milliseconds, P < 0.0001) with no change in CV between the two phases (0.88 vs. 0.91 m/s, P = 0.79). CONCLUSION: CV at the CTI is not slower than other RA regions during typical AFL. The gradual downslope of the sawtooth EKG  is not due to slow conduction at the CTI suggesting that success of ablation at this site relates to anatomical properties rather than the presence of a "slow isthmus."


Assuntos
Flutter Atrial/fisiopatologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Valva Tricúspide/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
19.
Europace ; 19(9): 1454-1462, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339601

RESUMO

AIMS: Initiating mechanisms of atrial fibrillation (AF) remain poorly understood, involving complex interaction between triggers and the atrial substrate. This study sought to classify the transitional phenomena, hypothesizing that there is consistency within and between patients in trigger-substrate interaction during transition to AF. METHODS AND RESULTS: Non-contact left atrial (LA) mapping was performed in 17 patients undergoing ablation for paroxysmal AF. All had spontaneous ectopy. Left atrial activation from the first ectopic to established AF was examined offline to characterize the initiating and transitional sequence of activation. In 57 fully mapped spontaneous AF initiations in 8 patients, all involved interaction of pulmonary venous/LA triggers with a septopulmonary line of block (SP-LOB) also evident in sinus rhythm, by 4 different transitional mechanisms characterized by (i) continuous focal firing: AF resulted from fragmentation of each ectopic wavefront through gaps in the SP-LOB and persisted only while focal firing continued (n = 18/32%) (ii) transient focal firing, wavefront fragmentation at the SP-LOB produced wavelet re-entry that persisted after cessation of an initiating ectopic source (n = 12/21%), (iii) of two separate interacting ectopic foci (n = 15/26%), or from (iv) transiently stable macroreentry (n = 12/21%), around the SP-LOB extending to the LA roof, resulting in progressive wavefront fragmentation. It was found that 79 ± 22% of each of the initiations in individual patients showed the same triggering mechanism. CONCLUSION: Onset of paroxysmal AF can be described by discrete mechanistic categories, all involving interaction of ectopic activity with a common SP-LOB. Within/between-patient consistency of initiations suggests constancy of the interacting triggers and substrate, and supports the concept of mechanistically tailored treatment.


Assuntos
Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
20.
Artigo em Inglês | MEDLINE | ID: mdl-28356307

RESUMO

BACKGROUND: The activation pattern of localized reentry (LR) in atrial tachycardia remains incompletely understood. We used the ultra-high density Rhythmia mapping system to study activation patterns in LR. METHODS AND RESULTS: LR was suggested by small rotatory activations (carousels) containing the full spectrum of the color-coded map. Twenty-three left-sided atrial tachycardias were mapped in 15 patients (age: 64±11 years). 16 253±9192 points were displayed per map, collected over 26±14 minutes. A total of 50 carousels were identified (median 2; quartiles 1-3 per map), although this represented LR in only n=7 out of 50 (14%): here, rotation occurred around a small area of scar (<0.03 mV; 12±6 mm diameter). In LR, electrograms along the carousel encompassed the full tachycardia cycle length, and surrounding activation moved away from the carousel in all directions. Ablating fractionated electrograms (117±18 ms; 44±13% of tachycardia cycle length) within the carousel interrupted the tachycardia in every LR case. All remaining carousels were pseudo-reentrant (n=43/50 [86%]) occurring in areas of wavefront collision (n=21; median 0.5; quartiles 0-2 per map) or as artifact because of annotation of noise or interpolation in areas of incomplete mapping (n=22; median 1, quartiles 0-2 per map). Pseudo-reentrant carousels were incorrectly ablated in 5 cases having been misinterpreted as LR. CONCLUSIONS: The activation pattern of LR is of small stable rotational activations (carousels), and this drove 30% (7/23) of our postablation atrial tachycardias. However, this appearance is most often pseudo-reentrant and must be differentiated by interpretation of electrograms in the candidate circuit and activation in the wider surrounding region.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Doença Iatrogênica , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...