Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-33080833

RESUMO

Environmental heat stress poses significant physiological challenge and impairs exercise performance. We investigated the impact of wrist percooling on running performance and physiological and perceptual responses in the heat. In a counterbalanced design, 13 trained males (33 ± 9 years, 15 ± 7% body fat, and maximal oxygen consumption, VO2max 59 ± 5 mL/kg/min) completed three 10 km running time trials (27 °C, 60% relative humidity) while wearing two cooling bands: (1) both bands were off (off/off), (2) one band on (off/on), (3) both bands on (on/on). Heart rate (HR), HR variability (HRV), mean arterial pressure (MAP), core temperature (TCO), thermal sensation (TS), and fatigue (VAS) were recorded at baseline and recovery, while running speed (RS) and rating of perceived exertion (RPE) were collected during the 10 km. Wrist cooling had no effect (p > 0.05) at rest, except modestly increased HR (3-5 ∆beats/min, p < 0.05). Wrist percooling increased (p < 0.05) RS (0.25 ∆mi/h) and HR (5 ∆beats/min), but not TCO (∆ 0.3 °C), RPE, or TS. Given incomplete trials, the distance achieved at 16 min was not different between conditions (off/off 1.96 ± 0.16 vs. off/on 1.98 ± 0.19 vs. on/on 1.99 ± 0.24 miles, p = 0.490). During recovery HRV, MAP, or fatigue were unaffected (p > 0.05). We demonstrate that wrist percooling elicited a faster running speed, though this coincides with increased HR; although, interestingly, sensations of effort and thermal comfort were unaffected, despite the faster speed and higher HR.


Assuntos
Frequência Cardíaca/fisiologia , Transtornos de Estresse por Calor/fisiopatologia , Corrida/fisiologia , Punho , Adulto , Regulação da Temperatura Corporal , Fadiga , Temperatura Alta , Humanos , Masculino , Esforço Físico
2.
J Occup Environ Med ; 60(11): 1049-0, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30188495

RESUMO

OBJECTIVE: To determine the effects of wrist cooling on recovery from exercise-induced heat stress (EIHS) from wearing firefighting personal protective equipment (PPE) and self-contained breathing apparatus. METHODS: Using a single-blind, counterbalanced, crossover-design, in 11 healthy men, we measured heart rate (HR), HR variability (HRV), core temperature (TCore), thermal strain (TS), and fatigue at rest, during 30-minute of exercise in PPE+SCBA, and during recovery while wearing a wrist cooling band (control[off] vs cool[on]). RESULTS: No differences were observed between trials at baseline or during exercise, in HR, TCore, TS, or fatigue. Time to 50% and recovery were not different between trials. Upon recovery, TCore was lower, while HR, fatigue, HRV, and TS were relatively indifferent with cooling. CONCLUSION: Wrist cooling after EIHS only modestly enhanced recovery, questioning its implementation during on-scene rehabilitation of firefighters.


Assuntos
Crioterapia , Exercício Físico/fisiologia , Resposta ao Choque Térmico/fisiologia , Adolescente , Adulto , Temperatura Corporal , Estudos Cross-Over , Fadiga/fisiopatologia , Incêndios , Frequência Cardíaca , Humanos , Masculino , Roupa de Proteção/efeitos adversos , Recuperação de Função Fisiológica , Dispositivos de Proteção Respiratória/efeitos adversos , Método Simples-Cego , Punho , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...