Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38919514

RESUMO

Gastric mucosal changes associated with long-term potassium-competitive acid blocker and proton pump inhibitor (PPI) therapy may raise concern. In contrast to that for PPIs, the evidence concerning the safety of long-term potassium-competitive acid blocker use is scant. Vonoprazan (VPZ) is a representative potassium-competitive acid blocker released in Japan in 2015. In order to shed some comparative light regarding the outcomes of gastric mucosal lesions associated with a long-term acid blockade, we have reviewed six representative gastric mucosal lesions: fundic gland polyps, gastric hyperplastic polyps, multiple white and flat elevated lesions, cobblestone-like gastric mucosal changes, gastric black spots, and stardust gastric mucosal changes. For these mucosal lesions, we have evaluated the association with the type of acid blockade, patient gender, Helicobacter pylori infection status, the degree of gastric atrophy, and serum gastrin levels. There is no concrete evidence to support a significant relationship between VPZ/PPI use and the development of neuroendocrine tumors. Current data also shows that the risk of gastric mucosal changes is similar for long-term VPZ and PPI use. Serum hypergastrinemia is not correlated with the development of some gastric mucosal lesions. Therefore, serum gastrin level is unhelpful for risk estimation and for decision-making relating to the cessation of these drugs in routine clinical practice. Given the confounding potential neoplastic risk relating to H. pylori infection, this should be eradicated before VPZ/PPI therapy is commenced. The evidence to date does not support the cessation of clinically appropriate VPZ/PPI therapy solely because of the presence of these associated gastric mucosal lesions.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39211761

RESUMO

Gastric endoscopic mucosal resection is challenging due to the slippery mucosa, abundant blood vessels, and the presence of mucus. We developed gel immersion endoscopy to secure the visual field, even in a blood-filled gastrointestinal lumen in 2016. Clear gel with appropriate viscosity, instead of water, can prevent rapid mixture with blood and facilitate identification of the culprit vessel. We further optimized the gel for endoscopic treatment, and the resultant product, Viscoclear (Otsuka Pharmaceutical Factory) was first released in Japan in 2020. The viscosity of this gel has been optimized to maximize endoscopic visibility without compromising the ease of its irrigation. The aim of this study is to clarify the effectiveness of gel immersion endoscopic mucosal resection for small-sized early gastric neoplasms. Seven lesions in seven patients were treated by gel immersion endoscopic mucosal resection. The size of all lesions was under 10 mm. The median procedure time was 4.5 min. Intraoperative bleeding occurred in four of seven lesions immediately after snare resection and was easily controlled by endoscopic hemostatic forceps during the gel immersion endoscopy. The R0 resection rate was 100%. In conclusion, gel immersion endoscopic mucosal resection may be a straightforward, rapid, and safe technique for resecting superficial gastric neoplasms <10 mm in diameter.

3.
Ann Gastroenterol ; 37(4): 418-426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974074

RESUMO

Background: Hemostatic powders are used as second-line treatment in acute gastrointestinal (GI) bleeding (AGIB). Increasing evidence supports the use of TC-325 as monotherapy in specific scenarios. This prospective, multicenter study evaluated the performance of TC-325 as monotherapy for AGIB. Methods: Eighteen centers across Europe and USA contributed to a registry between 2016 and 2022. Adults with AGIB were eligible, unless TC-325 was part of combined hemostasis. The primary endpoint was immediate hemostasis. Secondary outcomes were rebleeding and mortality. Associations with risk factors were investigated (statistical significance at P≤0.05). Results: One hundred ninety patients were included (age 51-81 years, male: female 2:1), with peptic ulcer (n=48), upper GI malignancy (n=79), post-endoscopic treatment hemorrhage (n=37), and lower GI lesions (n=26). The primary outcome was recorded in 96.3% (95% confidence interval [CI]: 92.6-98.5) with rebleeding in 17.4% (95%CI 11.9-24.1); 9.9% (95%CI 5.8-15.6) died within 7 days, and 21.7% (95%CI 15.6-28.9) within 30 days. Regarding peptic ulcer, immediate hemostasis was achieved in 88% (95%CI 75-95), while 26% (95%CI 13-43) rebled. Higher ASA score was associated with mortality (OR 23.5, 95%CI 1.60-345; P=0.02). Immediate hemostasis was achieved in 100% of cases with malignancy and post-intervention bleeding, with rebleeding in 17% and 3.1%, respectively. Twenty-six patients received TC-325 for lower GI bleeding, and in all but one the primary outcome was achieved. Conclusions: TC-325 monotherapy is safe and effective, especially in malignancy or post-endoscopic intervention bleeding. In patients with peptic ulcer, it could be helpful when the primary treatment is unfeasible, as bridge to definite therapy.

5.
Dig Liver Dis ; 56(10): 1752-1757, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38763794

RESUMO

INTRODUCTION: Endoscopic Submucosal Dissection (ESD) has been reported as a feasible and effective treatment for Rectal Neuroendocrine Tumours (R-NETs). However, most of the experience on the topic comes from retrospective tertiary centre from Eastern Asia. Data on ESD for R-NETs in Western centres are lacking. MATERIALS AND METHODS: This is a retrospective study, including patients who underwent endoscopic resection of R-NETS by ESD between 2015 and 2020 in Western Centres. Important clinical variables such as demographic, size of R-NETs, histological type, presence of lymphovascular invasion or distant metastasis, completeness of the endoscopic resection, recurrence, and procedure related complications were recorded. RESULTS: 40 ESD procedure on R-NETs from 39 patients from 8 centres were included. Mean R-NETs size was 10.3 mm (SD 4.01). Endoscopic en-bloc resection was achieved in 39/40 ESD (97.5 %), R0 margin resection was obtained in 87.5 % (35/40) of the procedures, one patient was referred to surgery for lymphovascular invasion, two procedures (5 %) reported significant episodes of bleeding, whereas a perforation occurred in one case (1/40, 2.5 %) managed endoscopically. Recurrence occurred in 1 patient (2.5 %). CONCLUSION: ESD is an effective and safe treatment for R-NETs in western centres.


Assuntos
Ressecção Endoscópica de Mucosa , Tumores Neuroendócrinos , Neoplasias Retais , Humanos , Estudos Retrospectivos , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Masculino , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Feminino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/patologia , Idoso , Recidiva Local de Neoplasia , Adulto , Resultado do Tratamento , Margens de Excisão
6.
Scand J Gastroenterol ; 59(8): 893-899, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38821110

RESUMO

BACKGROUND: Gastroesophageal reflux disease (GERD) symptoms frequently recur after cessation of acid blockers. The presence of a hiatal hernia may worsen GERD symptoms and increase the risk of esophageal malignancy. The aim of this study is to clarify the timing and predictors for recurrence of GERD symptoms after cessation of vonoprazan (VPZ) therapy. METHODS: A retrospective observational study involved 86 patients who underwent cessation of VPZ therapy for symptomatic GERD. Collated data from medical record review included the endoscopic findings and Izumo scale score. RESULTS: The mean duration of continuous VPZ therapy before cessation was 7.9 months. GERD symptoms requiring the resumption of VPZ therapy recurred in 66 of 86 patients (77%). Kaplan-Meier analysis showed that overall recurrence-free rates at 6 months, one and two years after VPZ cessation were 44%, 32% and 23%, respectively. Alcohol use, the presence of a hiatal hernia and long-term therapy for more than six months were identified as significant positive predictors for symptomatic recurrence. Notably, hiatal hernia had the highest hazard ratio in both univariate and multivariate analyses. The recurrence-free rate in patients with a hiatal hernia was much lower at 6 months than in patients without a hiatal hernia (15% and 51%, respectively p = 0.002). After the symptomatic recurrence, GERD symptoms improved significantly after one-month VPZ therapy. CONCLUSION: The rate of symptomatic recurrence after VPZ cessation in patients with GERD is considerable. Cessation of acid suppression therapy should be cautious in patients with both a hiatal hernia and GERD.


Assuntos
Refluxo Gastroesofágico , Hérnia Hiatal , Inibidores da Bomba de Prótons , Pirróis , Recidiva , Sulfonamidas , Humanos , Masculino , Feminino , Hérnia Hiatal/complicações , Estudos Retrospectivos , Sulfonamidas/uso terapêutico , Sulfonamidas/administração & dosagem , Sulfonamidas/efeitos adversos , Refluxo Gastroesofágico/tratamento farmacológico , Refluxo Gastroesofágico/complicações , Pessoa de Meia-Idade , Idoso , Pirróis/uso terapêutico , Pirróis/efeitos adversos , Pirróis/administração & dosagem , Inibidores da Bomba de Prótons/uso terapêutico , Inibidores da Bomba de Prótons/administração & dosagem , Estimativa de Kaplan-Meier , Fatores de Risco , Modelos de Riscos Proporcionais , Adulto , Análise Multivariada
8.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38670743

RESUMO

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Assuntos
Inteligência Artificial , Endoscopia por Cápsula , Hemorragia Gastrointestinal , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Hemorragia Gastrointestinal/diagnóstico , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Idoso , Adulto , Idoso de 80 Anos ou mais , Redes Neurais de Computação
11.
Cancers (Basel) ; 16(2)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38254841

RESUMO

A literature search of MEDLINE/PUBMED was conducted with the aim to highlight current endoscopic management of localised gastro-entero-pancreatic NETs. Relevant articles were identified through a manual search, and reference lists were reviewed for additional articles. The results of the research have been displayed in a narrative fashion to illustrate the actual state-of-the-art of endoscopic techniques in the treatment of NETs. Localised NETs of the stomach, duodenum and rectum can benefit from advanced endoscopic resection techniques (e.g., modified endoscopic mucosal resection, endoscopic full thickness resection, endoscopic submucosal dissection) according to centre expertise. Radiofrequency thermal ablation can be proposed as an alternative to surgery in selected patients with localised pancreatic NETs.

12.
Endoscopy ; 56(3): 174-181, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37949103

RESUMO

BACKGROUND: Device-assisted enteroscopy (DAE) has become a well-established diagnostic and therapeutic tool for the management of small-bowel pathology. We aimed to evaluate the performance measures for DAE across the UK against the quality benchmarks proposed by the European Society of Gastrointestinal Endoscopy (ESGE). METHODS: We retrospectively collected data on patient demographics and DAE performance measures from electronic endoscopy records of consecutive patients who underwent DAE for diagnostic and therapeutic purposes across 12 enteroscopy centers in the UK between January 2017 and December 2022. RESULTS: A total of 2005 DAE procedures were performed in 1663 patients (median age 60 years; 53% men). Almost all procedures (98.1%) were performed for appropriate indications. Double-balloon enteroscopy was used for most procedures (82.0%), followed by single-balloon enteroscopy (17.2%) and spiral enteroscopy (0.7%). The estimated depth of insertion was documented in 73.4% of procedures. The overall diagnostic yield was 70.0%. Therapeutic interventions were performed in 42.6% of procedures, with a success rate of 96.6%. Overall, 78.0% of detected lesions were marked with a tattoo. Patient comfort was significantly better with the use of deep sedation compared with conscious sedation (99.7% vs. 68.5%; P<0.001). Major adverse events occurred in only 0.6% of procedures. CONCLUSIONS: Performance measures for DAE in the UK meet the ESGE quality benchmarks, with high diagnostic and therapeutic yields, and a low incidence of major adverse events. However, there is room for improvement in optimizing sedation practices, standardizing the depth of insertion documentation, and adopting marking techniques to aid in the follow-up of detected lesions.


Assuntos
Enteropatias , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Enteropatias/diagnóstico , Enteropatias/terapia , Estudos Retrospectivos , Melhoria de Qualidade , Endoscopia Gastrointestinal/métodos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Enteroscopia de Duplo Balão/métodos
14.
Dig Liver Dis ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38057218

RESUMO

BACKGROUNDS AND AIMS: Mucosal healing (MH) in inflammatory bowel diseases (IBD) is an important landmark for clinical decision making. Artificial intelligence systems (AI) that automatically deliver the grade of endoscopic inflammation may solve moderate interobserver agreement and the need of central reading in clinical trials. METHODS: We performed a systematic review of EMBASE and MEDLINE databases up to 01/12/2022 following PRISMA and the Joanna Briggs Institute methodologies to answer the following question: "Can AI replace endoscopists when assessing MH in IBD?". The research was restricted to ulcerative colitis (UC), and a diagnostic odds ratio (DOR) meta-analysis was performed. Risk of bias was evaluated with QUADAS-2 tool. RESULTS: A total of 21 / 739 records were selected for full text evaluation, and 12 were included in the meta-analysis. Deep learning algorithms based on convolutional neural networks architecture achieved a satisfactory performance in evaluating MH on UC, with sensitivity, specificity, DOR and SROC of respectively 0.91(CI95 %:0.86-0.95);0.89(CI95 %:0.84-0.93);92.42(CI95 %:54.22-157.53) and 0.957 when evaluating fixed images (n = 8) and 0.86(CI95 %:0.75-0.93);0.91(CI95 %:0.87-0.94);70.86(CI95 %:24.63-203.86) and 0.941 when evaluating videos (n = 6). Moderate-high levels of heterogeneity were noted, limiting the quality of the evidence. CONCLUSIONS: AI systems showed high potential in detecting MH in UC with optimal diagnostic performance, although moderate-high heterogeneity of the data was noted. Standardised and shared AI training may reduce heterogeneity between systems.

15.
Endosc Int Open ; 11(11): E1099-E1107, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38026782

RESUMO

Background and study aims Endoscopic resection (ER) is recommended for the management of duodenal neuroendocrine tumors (D-NETs) confined to the submucosal layer, without lymph node or distant metastasis. While this is accepted practice for lesions < 10 mm, consensus for larger lesions remains unclear. Although endoscopic submucosal dissection (ESD) has been proposed as the preferred ER technique for DNETs ≥10 mm, there are limited data on efficacy and safety, particularly in the Western setting. Patients and methods We performed a retrospective analysis of patients with D-NETs who underwent ESD between 2012 and 2022 in three tertiary referral centers in Australia, France, and Belgium. Results Fourteen patients with 15 D-NETs were evaluated. Median patient age was 64 years (interquartile range [IQR] 58-70 years). All D-NETs were confined to the duodenal bulb. Median D-NET size was 10 mm (IQR 7-12 mm) and specimen size was 15 mm (IQR 15-20 mm). Median procedure time was 60 minutes (IQR 25-90 minutes). The rate of en bloc resection was 100%. Intra-procedural perforation occurred in four patients (26.7%), with all closed endoscopically without long-term sequelae. There were no episodes of clinically significant bleeding. No local recurrence, lymph node or distant metastasis was observed at a median follow-up of 19.9 months (IQR 10.3-49.3 months). Conclusions In experienced hands, ESD for D-NETs can achieve a 100% en bloc resection rate. There were no cases of local recurrence or distant metastatic spread, indicating that ESD may be a viable option for patients with D-NETs 10 to 15 mm that are not surgical candidates.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37652651

RESUMO

Device-assisted enteroscopy (DAE), balloon-assisted enteroscopy (BAE) in particular, has become a routine endoscopic procedure which has revolutionized our approach to small-bowel disease. Evidence demonstrating the efficacy and safety of BAE spans over 22-years of experience, making it an established pillar of minimally invasive care. The robust evidence for BAE's safety and efficacy has now been incorporated into international clinical guidelines, technical reviews, benchmarking performance measures and curricula. The more recently introduced motorized spiral enteroscopy (MSE) which had replaced the previous manual version, abruptly ended its 7-year stint in clinical practice, when it was withdrawn and recalled from the market by its manufacturing company in July 2023, due to several associated serious adverse events (including fatalities). This article, written by the original developer of double-balloon enteroscopy (DBE) and other recognized international experts and pioneers in this field, focuses mainly on the technical aspects, evolving indications, and equipment-related technological advances. Despite the very recent withdrawal of MSE from clinical practice, for completeness, this technology and its technique is still briefly covered here, albeit importantly, along with a short description of reported, associated, serious adverse events which have contributed to its withdrawal/recall from the market and clinical practice.


Assuntos
Enteropatias , Laparoscopia , Humanos , Intestino Delgado , Enteroscopia de Duplo Balão/efeitos adversos , Enteroscopia de Duplo Balão/métodos , Enteropatias/etiologia , Enteropatias/cirurgia
18.
Endoscopy ; 55(1): 58-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36423618

RESUMO

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/terapia , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Enteropatias/diagnóstico , Enteropatias/terapia
19.
Endoscopy ; 54(9): 904-915, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35913069

RESUMO

The European Society of Gastrointestinal Endoscopy (ESGE) presents a short list of performance measures for colonoscopy in inflammatory bowel disease (IBD) patients. Current performance measures for colonoscopy mainly focus on detecting (pre)malignant lesions. However, these performance measures are not relevant for all colonoscopy indications in IBD patients. Therefore, our aim was to provide endoscopy services across Europe and other interested countries with a tool for quality monitoring and improvement in IBD colonoscopy. Eight key performance measures and one minor performance measure were recommended for measurement and evaluation in daily endoscopy practice.


Assuntos
Doenças Inflamatórias Intestinais , Melhoria de Qualidade , Colonoscopia , Endoscopia Gastrointestinal , Europa (Continente) , Humanos , Doenças Inflamatórias Intestinais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...