Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
1.
Z Gerontol Geriatr ; 56(8): 653, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36662243
2.
Z Gerontol Geriatr ; 56(8): 647-652, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36478131

RESUMO

BACKGROUND: The aim of this study was to evaluate ultrasound as a routinely used procedure and extended physical examination in geriatric patients in acute care. METHODS: Prospective study of 86 patients using ultrasound as a screening examination (abdomen, basal sections of the thorax, thyroid glands) under comparative use of a hand-held ultrasound device (HHUSD) and a high-end ultrasound (HEUS = gold standard). RESULTS: In 20/86 (23.2%) clinically relevant findings with therapeutic consequences were found (pleural effusion, urinary retention, choledocholithiasis metatases, colon tumor). In 22/86 (25.6%) patients, additional questions existed besides the screening indication: tumor search (9.3%), anemia (5.8%), liver value elevation (5.8%), dyspnea (5.8%), splenic pathologies (2.3%), weight loss (1.2%), infectious focus (1.2%), diarrhea (1.2%), intra-abdominal hematoma (1.1%), abdominal aortic aneurysm (1.2%). The most common sonographic findings included: cholecystolithiasis (32.6%); right pleural effusion (31.4%), thyroid nodules (30.2%), renal cysts (27.9%), and fatty liver (26.7%). There were significant differences in sizing between HHUSD and HEUS (kidneys, pancreatic corpus and pancreatic caudal diameters, portal vein, left hepatic vein) without diagnostic relevance. CONCLUSION: The extended screening by ultrasound provided important answers to classical questions in geriatrics (e.g. urinary retention, volume deficiency/pleural effusion) in many cases. The new findings had therapeutic consequences in one fifth of the patients. The HHUSD can be used in screening.


Assuntos
Derrame Pleural , Retenção Urinária , Humanos , Idoso , Estudos Prospectivos , Ultrassonografia/métodos , Abdome/diagnóstico por imagem
3.
J Ultrasound ; 26(1): 249-254, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36180766

RESUMO

Budd-Chiari syndrome (BCS) is a rare disease with a variable clinical presentation and often late diagnosis. Doppler ultrasonography (DUS) permits to determine the site of the obstructed venous tracts, the thrombotic or non-thrombotic nature of the obstruction with its morphologic features and the flow-pattern alterations. Other non-specific findings, which are seen in most of the other liver diseases, include ascites, hepatosplenomegaly and caudate hypertrophy. The aim of this study is to show our experience in BCS reporting retrospectively 15 cases referred to our hepatology center between 2017 and 2021. Four selected cases depict the extreme heterogeneous behaviour of BCS and highlight the importance of DUS as a diagnostic tool when there is a clinical suspicion. In patients, mainly young, who present with ascites and abdominal pain, BCS has to be considered and DUS is the first imaging technique to be performed to rule it out.


Assuntos
Síndrome de Budd-Chiari , Fígado , Humanos , Dor Abdominal/diagnóstico por imagem , Dor Abdominal/etiologia , Ascite/diagnóstico por imagem , Ascite/etiologia , Síndrome de Budd-Chiari/diagnóstico , Fígado/diagnóstico por imagem , Doenças Raras , Ultrassonografia Doppler , Estudos Retrospectivos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade
4.
Eur Radiol ; 31(10): 7614-7625, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33855588

RESUMO

OBJECTIVES: Hepatocellular carcinoma (HCC) can be diagnosed non-invasively with contrast-enhanced ultrasound (CEUS) in cirrhosis if the characteristic pattern of arterial phase hyperenhancement followed by hypoenhancement is present. Recent studies suggest that diagnosis based on this "hyper-hypo" pattern needs further refinement. This study compares the diagnostic accuracies of standardized CEUS for HCC according to the current guideline definition and following the newly developed CEUS algorithms (CEUS LI-RADS®, ESCULAP) in a prospective multicenter real-life setting. METHODS: Cirrhotic patients with liver lesions on B-mode ultrasound were recruited prospectively from 04/2018 to 04/2019, and clinical and imaging data were collected. The CEUS standard included an additional examination point after 4-6 min in case of no washout after 3 min. The diagnostic accuracies of CEUS following the guidelines ("hyper-hypo" pattern), based on the examiner's subjective interpretation ("CEUS subjective"), and based on the CEUS algorithms ESCULAP and CEUS LI-RADS® were compared. RESULTS: In total, 470 cirrhotic patients were recruited in 43 centers. The final diagnosis was HCC in 378 cases (80.4%) according to the reference standard (histology 77.4%, MRI 16.4%, CT 6.2%). The "hyper-hypo" pattern yielded 74.3% sensitivity and 63% specificity. "CEUS subjective" showed a higher diagnostic accuracy (sensitivity, 91.5%; specificity, 67.4%; positive predictive value, 92%; negative predictive value, 66%). Sensitivity was higher for ESCULAP (95%) and "CEUS subjective" (91.5%) versus CEUS LI-RADS® (65.2%; p < 0.001). Specificity was highest for CEUS LI-RADS® (78.6%; p < 0.001). CONCLUSIONS: CEUS has an excellent diagnostic accuracy for the non-invasive diagnosis of HCC in cirrhosis. CEUS algorithms may be a helpful refinement of the "hyper-hypo" pattern defined by current HCC guidelines. KEY POINTS: • Contrast-enhanced ultrasound (CEUS) has a high diagnostic accuracy for the non-invasive diagnosis of hepatocellular carcinoma (HCC) in cirrhosis. • The CEUS algorithm ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) showed the highest sensitivity, whereas the CEUS LI-RADS® (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System) algorithm yielded the highest specificity. • A standardized CEUS examination procedure with an additional examination point in the late phase, after 4-6 min in lesions with no washout after 3 min, is vital.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Algoritmos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia
5.
Med Klin Intensivmed Notfmed ; 116(3): 254-258, 2021 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-33559701

RESUMO

Postmortem imaging has been used primarily in forensic medicine since 1895. Conventional x­ray, computed tomography (CT), and magnetic resonance imaging (MRI) are used. In studies, sonography is not considered to be of particular value, especially because of postmortem gas formation in adults. We report three cases in which postmortem sonography within three hours of death allowed clarification of a previously unclear cause of death.


Assuntos
Medicina Legal , Tomografia Computadorizada por Raios X , Adulto , Autopsia , Humanos , Imageamento por Ressonância Magnética , Ultrassonografia
7.
Ultrasound Int Open ; 2(1): E2-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27689163

RESUMO

The European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) recommends that ultrasound should be used systematically as an easy accessible and instructive educational tool in the curriculum of modern medical schools. Medical students should acquire theoretical knowledge of the modality and hands-on training should be implemented and adhere to evidence-based principles. In this paper we report EFSUMB policy statements on medical student education in ultrasound that in a short version is already published in Ultraschall in der Medizin 1.

8.
Ultraschall Med ; 37(4): 412-20, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27490463

RESUMO

The fifth section of the Guidelines on Interventional Ultrasound (INVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date. Celiac plexus neurolysis and block, vascular intervention, drainage of fluid collections, drainage of biliary and pancreatic ducts, and experimental tumor ablation techniques are discussed. For each topic, all current evidence has been extensively analyzed and summarized into major recommendations for reader consultation (short version; the long version is published online).


Assuntos
Meios de Contraste , Fosfolipídeos , Hexafluoreto de Enxofre , Ultrassonografia de Intervenção , Criança , Aprovação de Drogas , Europa (Continente) , Humanos , Sociedades Médicas , Estados Unidos , United States Food and Drug Administration
9.
Z Gastroenterol ; 54(8): 774-90, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27529528

RESUMO

Enlarged or irregular lymph nodes (LNs) are clinical and imaging findings in a large variety of malignant and non-malignant diseases. A comprehensive diagnostic work up is usually necessary in order to differentiate the benign or the malignant nature of the altered LNs. The diagnosis has to be made using all clinical information and, if necessary, assessed LNs need to be biopsied and further, histologically or microbiologically characterized. However, imaging techniques, and particularly ultrasonography (US), are essential on the way to the final diagnosis, from initial detection and characterization to follow-up of biopsy guidance. Computed-tomography (CT) and/or magnetic resonance imaging (MRI) are of great value for oncological diseases staging and treatment monitoring. Imaging techniques are helpful in distinguishing between benign and malignant LNs disease as well as between LNs metastases and lymphoma in most cases. Furthermore, imaging can define the extent and distribution of malignant diseases. It may assist, through the use of particular techniques such as elastography, to identify the most suspicious LN to be biopsied and to guide targeted biopsies from the most suspicious areas. It also serves as the main tool for the evaluation of treatment response in malignant diseases. The quality of LNs imaging has remarkably improved in recent years. New methods, such as contrast-enhanced ultrasonography (CEUS), elastography, positron emission tomography (PET)/PET-CT, as well as diffusion weighted imaging (DWI) in MRI, have already led to substantial changes in clinical practice. This review describes the most recent imaging techniques for LNs assessment, and their particular clinical value, with a special emphasis on the role of US techniques. Strengths and weaknesses of different imaging tools are discussed comprehensively, highlighting the importance of a corroborative attitude for successful management of each particular case.


Assuntos
Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/patologia , Ultrassonografia/métodos , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Z Gastroenterol ; 54(7): 653-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27429103

RESUMO

In 2000, the World Health Organization (WHO) issued an ultrasound field protocol for assessing the morbidity due to Schistosoma (S.) haematobium and S. mansoni. The experience with this classification has recently been reviewed systematically. The WHO protocol was well accepted worldwide. Here we review the use of ultrasound to assess the morbidity due to schistosomiasis with emphasis on easy, quick, and reproducible ways that can be used in the field. Findings obtained with high-end ultrasound scanners in the hospital setting that might eventually have applications in the field are also described.


Assuntos
Erros de Diagnóstico/prevenção & controle , Aumento da Imagem/métodos , Esquistossomose/diagnóstico por imagem , Ultrassonografia/métodos , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos
11.
Z Gastroenterol ; 54(6): 541-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27284928

RESUMO

PURPOSE: To evaluate the safety and intermediate-term efficacy of percutaneous microwave ablation (MWA) in primary and secondary liver tumors using a third generation MWA device, under ultrasound guidance. PATIENTS AND METHODS: Sixty-two patients (median age 74 years, 73 % males) with 69 liver tumors were enrolled in this prospective observational study. Forty-seven patients (76 %) had hepatocellular carcinoma (HCC) and 15 (24 %) metastases. Median follow-up was 3.6 years. RESULTS: Median tumor diameter at contrast enhanced computed tomography was 23 mm (I-III quartiles, 18 - 31 mm). All procedures were performed percutaneously using a 2.45 GHz generator. Median ablation time was 10 minutes (I-III quartiles, 10 - 14 minutes). A single percutaneous antenna insertion was performed for 56/69 (81 %) of the tumors. Technical success was obtained in all tumors. Primary efficacy at 24 hours was achieved in 68/69 (99 %) tumors. The overall one-year cumulative local tumor progression rate was 15.1 % (95 % CI, 7.7 - 24.8 %) with no significant difference between HCC and metastases (p = 0.26). There was one procedure-related mortality (1.6 %) and one major bleeding (1.6 %). CONCLUSION: Microwave ablation is a valid option for thermal ablation of HCC and liver metastases with comparable complication rate to other local ablative procedures.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/estatística & dados numéricos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/prevenção & controle , Idoso , Ablação por Cateter/mortalidade , Estudos de Coortes , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Estudos Prospectivos , Taxa de Sobrevida , Resultado do Tratamento
12.
Z Gastroenterol ; 54(6): 569-78, 2016 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-27284933

RESUMO

Artifacts in ultrasonographic diagnostics are a result of the physical properties of the ultrasound waves and are caused by interaction of the ultrasound waves with biological structures and tissues of the body and with foreign materials. On the one hand, they may be diagnostically helpful. On the other hand, they may be distracting and may lead to misdiagnosis. Profound knowledge of the causes, avoidance, and interpretation of artifacts is a necessary precondition for correct clinical appraisal of ultrasound images. Part 1 of this review commented on the physics of artifacts and described the most important B-mode artifacts. Part 2 focuses on the clinically relevant artifacts in Doppler and color-coded duplex sonography. Problems and pitfalls of interpretation arising from artifacts, as well as the diagnostic use of Doppler and colour-coded duplex sonography, are discussed.


Assuntos
Artefatos , Erros de Diagnóstico/prevenção & controle , Doenças do Sistema Digestório/diagnóstico por imagem , Aumento da Imagem/métodos , Ultrassonografia Doppler em Cores/métodos , Medicina Baseada em Evidências , Humanos , Medicina Interna/métodos
13.
Z Gastroenterol ; 54(5): 433-50, 2016 May.
Artigo em Alemão | MEDLINE | ID: mdl-27171335

RESUMO

Artifacts in ultrasonographic diagnostics are a result of the physical properties of the ultrasound waves and are caused by interaction of the ultrasound waves with biological structures and tissues and with foreign bodies. On the one hand, they may be distracting and may lead to misdiagnosis. On the other hand, they may be diagnostically helpful. Ultrasound imaging suffers from artifacts, because in reality, parameters assumed to be constant values, such as sound speed, sound rectilinear propagation, attenuation, etc., are often different from the actual parameters. Moreover, inadequate device settings may cause artifacts. Profound knowledge of the causes, avoidance, and interpretation of artifacts is a necessary precondition for correct clinical appraisal of ultrasound images. Part 1 of this review comments on the physics of artifacts and describes the most important B-mode artifacts. Pitfalls, as well as diagnostic chances resulting from B-mode artifacts, are discussed.


Assuntos
Artefatos , Erros de Diagnóstico/prevenção & controle , Gastroenterologia/métodos , Aumento da Imagem/métodos , Medicina Interna/métodos , Ultrassonografia/métodos , Humanos
14.
Ultraschall Med ; 37(2): 157-69, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27058434

RESUMO

The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-guided sampling. Endoscopic ultrasound combines the most advanced high-resolution ultrasound imaging of lesions within the wall and in the vicinity of the gastrointestinal tract and safe and effective fine needle-based tissue acquisition from these lesions. The guideline addresses the indications, contraindications, techniques, adverse events, training and clinical impact of EUS-guided sampling. Advantages and drawbacks are weighed in comparison with image-guided percutaneous biopsy. Based on the most current evidence, clinical practice recommendations are given for crucial preconditions and steps of EUS-guided sampling as well as for safe performance. Additionally, the guideline deals with the principles and reliability of cytopathological reporting in endoscopic ultrasound-guided sampling (short version; the long version is published online).


Assuntos
Biópsia por Agulha , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Sociedades Médicas , Ultrassonografia de Intervenção , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Desenho de Equipamento , Europa (Continente) , Garantia da Qualidade dos Cuidados de Saúde , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
15.
Z Gastroenterol ; 54(4): 304-11, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27056458

RESUMO

INTRODUCTION: The number of publications concerning mesenteric Doppler sonography (mesDS) is immense and does not correlate with the frequency of its use in clinical practice. This is astonishing since it provides real time blood flow (perfusion) information without side effects. Despite uncontrollable parameters like the technical limitations in some situations the optimization of (possibly) controllable parameters like standardization, production of normal values and reduction of the investigator variability by evaluating stable parameters could change the situation. PATIENTS AND METHODS: 10 investigators experienced in abdominal sonography ("DEGUM-Seminarleiter") performed mesenteric Doppler sonography in 5 healthy subjects with 5 different machines. RESULTS: The portal vein at the confluence and the common hepatic artery provide a significant portion of investigations with intromission angles of more than 60°. Values of diameter, resistance index and pulsatility index of the celiac trunc could be obtained with inter-observer variability values below 25 %. The proper and the common hepatic artery show no differences in inter-observer variability values, whereas the intrahepatic measure point of the portal vein showed a higher reproducibility. DISCUSSION: We define frame conditions for future mesenteric Doppler studies: the portal vein should be investigated at the intrahepatic measure point. Pathophysiological studies should refrain from velocity parameters except in the case of larger vessels running in a straight course towards the probe.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Mesentéricas/diagnóstico por imagem , Artérias Mesentéricas/fisiologia , Variações Dependentes do Observador , Ultrassonografia Doppler Dupla/métodos , Resistência Vascular/fisiologia , Adulto , Competência Clínica , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
16.
Ultraschall Med ; 37(3): 262-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27070127

RESUMO

PURPOSE: Many patients with thyroid nodules are presently referred to surgery for not only therapeutic but also diagnostic purposes. The aim of noninvasive diagnostic methods is to optimize the selection of patients for surgery. Strain elastography (SE) enables the ultrasound-based determination of tissue elasticity. The aim of the present study was to evaluate the value of SE for the differentiation of thyroid nodules in a prospective multicenter study. MATERIALS AND METHODS: The study was registered at clinicaltrials.gov and was approved by the local ethics committees of all participating centers. All patients received an ultrasound (US) of the thyroid gland including color Doppler US. In addition, all nodules were evaluated by SE (Hitachi Medical Systems) using qualitative image interpretation of color distribution (SE-ES), strain value and strain ratio. RESULTS: Overall, 602 patients with 657 thyroid nodules (567 benign, 90 malignant) from 7 centers were included in the final analysis. The sensitivity, specificity, NPV, PPV, +LR were 21 %, 73 %, 86 %, 11 %, 0.8, respectively, for color Doppler US; 69 %, 75 %, 94 %, 30 %, 2.9, respectively, for SE-ES; 56 %, 81 %, 92 %, 32 %, 2.9, respectively, for SE-strain value; and 58 %, 78 %, 92 %, 30 %, 2.6, respectively, for SE-strain ratio. The diagnostic accuracy was 71 % for both strain value and strain ratio of nodules. CONCLUSION: SE as an additional ultrasound tool improves the value of ultrasound for the work-up of thyroid nodules. It might reduce diagnostic surgery of thyroid nodules in the future.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Diagnóstico Diferencial , Feminino , Alemanha , Bócio Nodular/diagnóstico por imagem , Bócio Nodular/patologia , Bócio Nodular/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Sociedades Médicas , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/cirurgia , Ultrassonografia Doppler em Cores , Adulto Jovem
17.
Ultraschall Med ; 37(1): 100-2, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26871409

RESUMO

The European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) recommends that ultrasound should be used systematically as an easy accessible and instructive educational tool in the curriculum of modern medical schools. Medical students should acquire theoretical knowledge of the modality and hands-on training should be implemented and adhere to evidence-based principles. In this paper we summarise EFSUMB policy statements on medical student education in ultrasound.


Assuntos
Educação Médica , Sociedades Médicas , Ultrassonografia , Currículo , Medicina Baseada em Evidências , Alemanha , Humanos
18.
Ultraschall Med ; 37(1): 27-45, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26871408

RESUMO

The third part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound assesses the evidence for ultrasound-guided and assisted interventions in abdominal treatment procedures. Recommendations for clinical practice are presented covering indications, contraindications, safety and efficacy of the broad variety of these techniques. In particular, drainage of abscesses and fluid collections, interventional tumor ablation techniques, interventional treatment of symptomatic cysts and echinococcosis, percutaneous transhepatic cholangiography and drainage, percutaneous gastrostomy, urinary bladder drainage, and nephrostomy are addressed (short version; a long version is published online).


Assuntos
Abdome/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Abscesso Abdominal/diagnóstico por imagem , Abscesso Abdominal/cirurgia , Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/cirurgia , Colangiografia/métodos , Cistos/diagnóstico por imagem , Cistos/cirurgia , Drenagem/métodos , Gastrostomia/métodos , Alemanha , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Nefrostomia Percutânea/métodos , Segurança do Paciente , Garantia da Qualidade dos Cuidados de Saúde , Resultado do Tratamento , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/cirurgia
19.
Laryngorhinootologie ; 95(2): 87-104, 2016 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-26859730

RESUMO

Thyroid nodules and thyroid abnormalities are common findings in the general population. Ultrasonography is the most important imaging tool for diagnosing thyroid disease. In the majority of cases a correct diagnosis can already be made in synopsis of the sonographic together with clinical findings and basal thyroid hormone parameters and an appropriate therapy can be initiated thereafter. A differentiation of hormonally active vs. inactive nodes, and in particular benign vs. malignant nodules is sonographically, however, not reliably possible. In this context, radioscanning has its clinical significance predominantly in diagnosing hormonal activity of thyroid nodules. Efforts of the past years aimed to improve sonographic risk stratification to predict malignancy of thyroid nodules through standardized diagnostic assessment of evaluated risk factors in order to select patients, who need further diagnostic work up. According to the "Breast Imaging Reporting and Data System" (BI-RADS), "Thyroid Imaging Reporting and Data Systems" (TI-RADS) giving standardized categories with rates of malignancy were evaluated as a basis for further clinical management. Recent technological developments, such as elastography, also showpromising data and could gain entrance into clinical practice. The ultrasound-guided fineneedle aspiration is the key element in the diagnosis of sonographically suspicious thyroid nodules and significantly contributes to the diagnosis of malignancy versus benignity.


Assuntos
Doenças da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Biópsia por Agulha Fina , Diagnóstico Diferencial , Fidelidade a Diretrizes , Humanos , Fatores de Risco , Doenças da Glândula Tireoide/etiologia , Doenças da Glândula Tireoide/terapia , Testes de Função Tireóidea , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/etiologia , Neoplasias da Glândula Tireoide/terapia , Nódulo da Glândula Tireoide/etiologia , Nódulo da Glândula Tireoide/terapia , Ultrassonografia de Intervenção
20.
Z Gastroenterol ; 54(2): 155-66, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26854836

RESUMO

Cystic lesions in the liver and kidneys are common incidental findings. They are generally benign and require no treatment. They can appear sporadically or as part of a syndrome, and are characterised by their anechoic structure and posterior enhancement in ultrasound imaging. Increased size, haemorrhage or infection of a cyst can lead to development of symptoms. Along with surgical options and laparoscopic cyst fenestration, ultrasound-guided sclerotherapy of symptomatic cysts represents an effective and safe minimally invasive treatment option.


Assuntos
Cistos/terapia , Doenças Renais Císticas/terapia , Hepatopatias/terapia , Guias de Prática Clínica como Assunto , Soluções Esclerosantes/uso terapêutico , Escleroterapia/métodos , Cistos/diagnóstico por imagem , Alemanha , Humanos , Doenças Renais Císticas/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Soluções Esclerosantes/normas , Ultrassonografia de Intervenção/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...