Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 328
Filtrar
1.
Neuroradiology ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967815

RESUMO

PURPOSE: To assess image quality and diagnostic confidence of 3D T1-weighted spoiled gradient echo (SPGR) MRI using artificial intelligence (AI) reconstruction. MATERIALS AND METHODS: This prospective, IRB-approved study enrolled 50 pediatric patients (mean age = 11.8 ± 3.1 years) undergoing clinical brain MRI. In addition to standard of care (SOC) compressed SENSE (CS = 2.5), 3D T1-weighted SPGR images were obtained with higher CS acceleration factors (5 and 8) to evaluate the ability of AI reconstruction to improve image quality and reduce scan time. Images were reviewed independently on dedicated research PACS workstations by two neuroradiologists. Quantitative analysis of signal intensities to calculate apparent grey and white matter signal to noise (aSNR) and grey-white matter apparent contrast to noise ratios (aCNR) was performed. RESULTS: AI improved overall image quality compared to standard CS reconstruction in 35% (35/100) of evaluations in CS = 2.5 (average scan time = 221 ± 6.9 s), 100% (46/46) of CS = 5 (average scan time = 113.3 ± 4.6 s) and 94% (47/50) of CS = 8 (average scan time = 74.1 ± 0.01 s). Quantitative analysis revealed significantly higher grey matter aSNR, white matter aSNR and grey-white matter aCNR with AI reconstruction compared to standard reconstruction for CS 5 and 8 (all p-values < 0.001), however not for CS 2.5. CONCLUSIONS: AI reconstruction improved overall image quality and gray-white matter qualitative and quantitative aSNR and aCNR in highly accelerated (CS = 5 and 8) 3D T1W SPGR images in the majority of pediatric patients.

2.
Pediatr Radiol ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890153

RESUMO

BACKGROUND: Artificial intelligence (AI) reconstruction techniques have the potential to improve image quality and decrease imaging time. However, these techniques must be assessed for safe and effective use in clinical practice. OBJECTIVE: To assess image quality and diagnostic confidence of AI reconstruction in the pediatric brain on fluid-attenuated inversion recovery (FLAIR) imaging. MATERIALS AND METHODS: This prospective, institutional review board (IRB)-approved study enrolled 50 pediatric patients (median age=12 years, Q1=10 years, Q3=14 years) undergoing clinical brain MRI. T2-weighted (T2W) FLAIR images were reconstructed by both standard clinical and AI reconstruction algorithms (strong denoising). Images were independently rated by two neuroradiologists on a dedicated research picture archiving and communication system (PACS) to indicate whether AI increased, decreased, or had no effect on image quality compared to standard reconstruction. Quantitative analysis of signal intensities was also performed to calculate apparent signal to noise (aSNR) and apparent contrast to noise (aCNR) ratios. RESULTS: AI reconstruction was better than standard in 99% (reader 1, 49/50; reader 2, 50/50) for overall image quality, 99% (reader 1, 49/50; reader 2, 50/50) for subjective SNR, and 98% (reader 1, 49/50; reader 2, 49/50) for diagnostic preference. Quantitative analysis revealed significantly higher gray matter aSNR (30.6±6.5), white matter aSNR (21.4±5.6), and gray-white matter aCNR (7.1±1.6) in AI-reconstructed images compared to standard reconstruction (18±2.7, 14.2±2.8, 4.4±0.8, p<0.001) respectively. CONCLUSION: We conclude that AI reconstruction improved T2W FLAIR image quality in most patients when compared with standard reconstruction in pediatric patients.

3.
Radiology ; 311(2): e233136, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742971

RESUMO

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Reprodutibilidade dos Testes , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cirrose Hepática/diagnóstico por imagem
4.
Abdom Radiol (NY) ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724774

RESUMO

BACKGROUND: MRI diffusion-weighted imaging (DWI) is commonly used in MR enterography protocols for assessment of intestinal inflammation in patients with Crohn's disease. The intravoxel incoherent motion (IVIM) approach to DWI has been proposed as a more objective approach, providing quantitative parameters that reflect water diffusivity (D), blood flow (D*), and perfusion fraction (f). PURPOSE: We aimed to determine if DWI-IVIM metrics from the terminal ileum in patients with newly diagnosed Crohn's disease differ from healthy participants and change in response to biologic medical therapy. METHODS: In this prospective case-control study, 20 consecutive pediatric patients (mean age = 14 years ± 2 [SD]; eight females) with newly diagnosed ileal Crohn's disease and 15 pediatric healthy participants (mean age = 18 years ± 4 [SD]; eight females) underwent research MRI examinations of the small bowel between 12/2018 and 10/2021. Participants with Crohn's disease underwent MR studies at baseline, 6 weeks, and 6 months following initiation of anti-TNF-alpha therapy, whereas control participants underwent one research MRI examination. The MRI protocol included a DWI-IVIM sequence with nine b-values and the IVIM parameters (D, D*, and f) were extracted. Unpaired t-tests and mixed-effects models were used for analyses. RESULTS: Mean IVIM D (P < 0.001), D* (P = 0.004), and f (P = 0.001) metrics were lower for Crohn's patients at the time of diagnosis compared to healthy participants. Mean IVIM f value increased over time in response to medical therapy (mean f at baseline, 22% ± 6%; 6 weeks, 25% ± 7%; 6 months, 29% ± 10%; P = 0.016). Mean IVIM D* value increased over time in response to treatment (mean D* at baseline, 10.9 ± 3.0 × 10-3 mm2/s; 6 weeks, 11.8 ± 2.8 × 10-3 mm2/s; 6 months, 13.3 ± 3.3 × 10-3 mm2/s; P = 0.047), while there was no significant change in mean IVIM D value (P = 0.10). CONCLUSION: MRI DWI-IVIM metrics in patients with ileal Crohn's disease change over time in response to biological therapy and help discriminate these patients from healthy participants.

5.
Inflamm Bowel Dis ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38738296

RESUMO

BACKGROUND: Despite advances in medical therapy, many children and adults with ileal Crohn's disease (CD) progress to fibrostenosis requiring surgery. We aimed to identify MRI and circulating biomarkers associated with the need for surgical management. METHODS: This prospective, multicenter study included pediatric and adult CD cases undergoing ileal resection and CD controls receiving medical therapy. Noncontrast research MRI examinations measured bowel wall 3-dimensional magnetization transfer ratio normalized to skeletal muscle (normalized 3D MTR), modified Look-Locker inversion recovery (MOLLI) T1 relaxation, intravoxel incoherent motion (IVIM) diffusion-weighted imaging metrics, and the simplified magnetic resonance index of activity (sMaRIA). Circulating biomarkers were measured on the same day as the research MRI and included CD64, extracellular matrix protein 1 (ECM1), and granulocyte-macrophage colony-stimulating factor (GM-CSF) autoantibodies (Ab). Associations between MRI and circulating biomarkers and need for ileal resection were tested using univariate and multivariable LASSO regression. RESULTS: Our study sample included 50 patients with CD undergoing ileal resection and 83 patients with CD receiving medical therapy; mean participant age was 23.9 ±â€…13.1 years. Disease duration and treatment exposures did not vary between the groups. Univariate biomarker associations with ileal resection included log GM-CSF Ab (odds ratio [OR], 2.87; P = .0009), normalized 3D MTR (OR, 1.05; P = .002), log MOLLI T1 (OR, 0.01; P = .02), log IVIM perfusion fraction (f; OR, 0.38; P = .04), and IVIM apparent diffusion coefficient (ADC; OR, 0.3; P = .001). The multivariable model for surgery based upon corrected Akaike information criterion included age (OR, 1.03; P = .29), BMI (OR, 0.91; P = .09), log GM-CSF Ab (OR, 3.37; P = .01), normalized 3D MTR (OR, 1.07; P = .007), sMaRIA (OR, 1.14; P = .61), luminal narrowing (OR, 10.19; P = .003), log C-reactive protein (normalized; OR, 2.75; P = .10), and hematocrit (OR, 0.90; P = .13). CONCLUSION: After accounting for clinical and MRI measures of severity, normalized 3D MTR and GM-CSF Ab are associated with the need for surgery in ileal CD.


Despite advances in medical therapy, many patients with ileal Crohn's disease progress to fibrostenosis requiring surgery. Our study has shown that GM-CSF autoantibodies and MRI biomarker sequences are associated with the need for ileal resection and may help guide management decisions.

6.
AJR Am J Roentgenol ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691411

RESUMO

Background: Deep-learning abdominal organ segmentation algorithms have shown excellent results in adults; validation in children is sparse. Objective: To develop and validate deep-learning models for liver, spleen, and pancreas segmentation on pediatric CT examinations. Methods: This retrospective study developed and validated deep-learning models for liver, spleen, and pancreas segmentation using 1731 CT examinations (1504 training, 221 testing), derived from three internal institutional pediatric (age ≤18) datasets (n=483) and three public datasets comprising pediatric and adult examinations with various pathologies (n=1248). Three deep-learning model architectures (SegResNet, DynUNet, and SwinUNETR) from the Medical Open Network for AI (MONAI) framework underwent training using native training (NT), relying solely on institutional datasets, and transfer learning (TL), incorporating pre-training on public datasets. For comparison, TotalSegmentator (TS), a publicly available segmentation model, was applied to test data without further training. Segmentation performance was evaluated using mean Dice similarity coefficient (DSC), with manual segmentations as reference. Results: For internal pediatric data, DSC for normal liver was 0.953 (TS), 0.964-0.965 (NT models), and 0.965-0.966 (TL models); normal spleen, 0.914 (TS), 0.942-0.945 (NT models), and 0.937-0.945 (TL models); normal pancreas, 0.733 (TS), 0.774-0.785 (NT models), and 0.775-0.786 (TL models); pancreas with pancreatitis, 0.703 (TS), 0.590-0.640 (NT models), and 0.667-0.711 (TL models). For public pediatric data, DSC for liver was 0.952 (TS), 0.876-0.908 (NT models), and 0.941-0.946 (TL models); spleen, 0.905 (TS), 0.771-0.827 (NT models), and 0.897-0.926 (TL models); pancreas, 0.700 (TS), 0.577-0.648 (NT models), and 0.693-0.736 (TL models). For public primarily adult data, DSC for liver was 0.991 (TS), 0.633-0.750 (NT models), and 0.926-0.952 (TL models); spleen, 0.983 (TS), 0.569-0.604 (NT models), and 0.923-0.947 (TL models); pancreas, 0.909 (TS), 0.148-0.241 (NT models), and 0.699-0.775 (TL models). DynUNet-TL was selected as the best-performing NT or TL model and was made available as an opensource MONAI bundle (https://github.com/cchmc-dll/pediatric_abdominal_segmentation_bundle.git). Conclusion: TL models trained on heterogeneous public datasets and fine-tuned using institutional pediatric data outperformed internal NT models and TotalSegmentator across internal and external pediatric test data. Segmentation performance was better in liver and spleen than in pancreas. Clinical Impact: The selected model may be used for various volumetry applications in pediatric imaging.

7.
Radiographics ; 44(5): e230121, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38602867

RESUMO

Liver congestion is increasingly encountered in clinical practice and presents diagnostic pitfalls of which radiologists must be aware. The complex altered hemodynamics associated with liver congestion leads to diffuse parenchymal changes and the development of benign and malignant nodules. Distinguishing commonly encountered benign hypervascular lesions, such as focal nodular hyperplasia (FNH)-like nodules, from hepatocellular carcinoma (HCC) can be challenging due to overlapping imaging features. FNH-like lesions enhance during the hepatic arterial phase and remain isoenhancing relative to the background liver parenchyma but infrequently appear to wash out at delayed phase imaging, similar to what might be seen with HCC. Heterogeneity, presence of an enhancing capsule, washout during the portal venous phase, intermediate signal intensity at T2-weighted imaging, restricted diffusion, and lack of uptake at hepatobiliary phase imaging point toward the diagnosis of HCC, although these features are not sensitive individually. It is important to emphasize that the Liver Imaging Reporting and Data System (LI-RADS) algorithm cannot be applied in congested livers since major LI-RADS features lack specificity in distinguishing HCC from benign hypervascular lesions in this population. Also, the morphologic changes and increased liver stiffness caused by congestion make the imaging diagnosis of cirrhosis difficult. The authors discuss the complex liver macro- and microhemodynamics underlying liver congestion; propose a more inclusive approach to and conceptualization of liver congestion; describe the pathophysiology of liver congestion, hepatocellular injury, and the development of benign and malignant nodules; review the imaging findings and mimics of liver congestion and hypervascular lesions; and present a diagnostic algorithm for approaching hypervascular liver lesions. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Assuntos
Carcinoma Hepatocelular , Hiperplasia Nodular Focal do Fígado , Neoplasias Hepáticas , Doenças Vasculares , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Meios de Contraste , Fígado/diagnóstico por imagem , Fígado/patologia , Hiperplasia Nodular Focal do Fígado/diagnóstico , Hiperplasia Nodular Focal do Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Estudos Retrospectivos
8.
AJR Am J Roentgenol ; : 1-12, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38630086

RESUMO

BACKGROUND. Liver fibrosis is an important clinical endpoint of the progression of autoimmune liver disease (AILD); its monitoring would benefit from noninvasive imaging tools. OBJECTIVE. The purpose of this study was to assess the relationship between MR elastography (MRE) liver stiffness measurements and histologic liver fibrosis, as well as to evaluate the performance of MRE and biochemical-based clinical markers for stratifying histologic liver fibrosis severity, in children and young adults with AILD. METHODS. This retrospective study used an existing institutional registry of children and young adults diagnosed with AILD (primary sclerosing cholangitis [PSC], autoimmune sclerosing cholangitis [ASC], or autoimmune hepatitis [AIH]). The registry was searched to identify patients who underwent both a research abdominal 1.5-T MRI examination that included liver MRE (performed for registry enrollment) and a clinically indicated liver biopsy within 6 months of that examination. MRE used a 2D gradient-recalled echo sequence. One analyst measured mean liver shear stiffness (in kilopascals) for each examination. Laboratory markers of liver fibrosis (aspartate aminotransferase-to-platelet ratio index [APRI] and fibrosis-4 [FIB-4] score) were recorded. For investigational purposes, one pathologist, blinded to clinical and MRI data, determined histologic Metavir liver fibrosis stage. The Spearman rank order correlation coefficient was calculated between MRE liver stiffness and Metavir liver fibrosis stage. ROC analysis was used to evaluate diagnostic performance for identifying advanced fibrosis (i.e., differentiating Metavir F0-F1 from F2-F4 fibrosis), and sensitivity and specificity were calculated using the Youden index. RESULTS. The study included 46 patients (median age, 16.6 years [IQR, 13.7-17.8 years]; 20 female patients, 26 male patients); 12 had PSC, 10 had ASC, and 24 had AIH. Median MRE liver stiffness was 2.9 kPa (IQR, 2.2-4.0 kPa). MRE liver stiffness and Meta-vir fibrosis stage showed strong positive correlation (ρ = 0.68). For identifying advanced liver fibrosis, MRE liver stiffness had an AUC of 0.81, with sensitivity of 65.4% and specificity of 90.0%; APRI had an AUC of 0.72, with sensitivity of 64.0% and specificity of 80.0%; and FIB-4 score had an AUC of 0.71, with sensitivity of 60.0% and specificity of 85.0%. CONCLUSION. MRE liver stiffness measurements were associated with histologic liver fibrosis severity. CLINICAL IMPACT. The findings support a role for MRE in noninvasive monitoring of liver stiffness, a surrogate for fibrosis, in children and young adults with AILD. TRIAL REGISTRATION. ClinicalTrials.gov NCT03175471.

9.
Abdom Radiol (NY) ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656368

RESUMO

PURPOSE: (1) To determine the frequency of surgical management in children with Crohn's Disease (CD) and a new radiologic ileal stricture, and (2) to identify imaging and clinical features that predict the need for surgery. METHODS: This retrospective study included pediatric patients (< 21 years old) with CD and a new ileal stricture diagnosed by MRE, CTE, or CT between July 2018 and June 2023. Three board-certified radiologists recorded stricture length, maximum mural thickness, minimum lumen diameter, maximum upstream diameter, and simplified magnetic resonance index of activity (sMaRIA) score. Anthropometrics, laboratory data, and surgical interventions performed after stricture diagnosis were also recorded. Multivariable logistic regression was used to identify imaging and clinical variables associated with the need for surgery. RESULTS: 44 pediatric CD patients (median age 16.5 years) presented with a new ileal stricture during the study period. 30 (68.2%) patients required surgery, with a median time of 87.5 days between stricture diagnosis and surgery. Median stricture measurements were length: 7.0 cm, maximum mural thickness: 7.3 mm, minimum lumen diameter: 0.2 cm, and maximum upstream diameter: 3.3 cm. Median sMaRIA score was 3.0, and 14 (31.8%) strictures had associated internal penetrating disease. Stricture ratio (ratio of maximum upstream lumen diameter to minimum lumen diameter) (OR = 1.15 [95% CI 1.02-1.30]; p = 0.02) and sMaRIA (OR = 2.12 [95% CI 0.87-5.17; p = 0.10) were associated with need for surgery. CONCLUSION: Surgery remains common in stricturing pediatric CD, with increasing stricture ratio and sMaRIA score associated with need for surgical management.

10.
Neuroimage ; 291: 120579, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537766

RESUMO

Very preterm (VPT) infants (born at less than 32 weeks gestational age) are at high risk for various adverse neurodevelopmental deficits. Unfortunately, most of these deficits cannot be accurately diagnosed until the age of 2-5 years old. Given the benefits of early interventions, accurate diagnosis and prediction soon after birth are urgently needed for VPT infants. Previous studies have applied deep learning models to learn the brain structural connectome (SC) to predict neurodevelopmental deficits in the preterm population. However, none of these models are specifically designed for graph-structured data, and thus may potentially miss certain topological information conveyed in the brain SC. In this study, we aim to develop deep learning models to learn the SC acquired at term-equivalent age for early prediction of neurodevelopmental deficits at 2 years corrected age in VPT infants. We directly treated the brain SC as a graph, and applied graph convolutional network (GCN) models to capture complex topological information of the SC. In addition, we applied the supervised contrastive learning (SCL) technique to mitigate the effects of the data scarcity problem, and enable robust training of GCN models. We hypothesize that SCL will enhance GCN models for early prediction of neurodevelopmental deficits in VPT infants using the SC. We used a regional prospective cohort of ∼280 VPT infants who underwent MRI examinations at term-equivalent age from the Cincinnati Infant Neurodevelopment Early Prediction Study (CINEPS). These VPT infants completed neurodevelopmental assessment at 2 years corrected age to evaluate cognition, language, and motor skills. Using the SCL technique, the GCN model achieved mean areas under the receiver operating characteristic curve (AUCs) in the range of 0.72∼0.75 for predicting three neurodevelopmental deficits, outperforming several competing models. Our results support our hypothesis that the SCL technique is able to enhance the GCN model in our prediction tasks.


Assuntos
Conectoma , Recém-Nascido Prematuro , Lactente , Recém-Nascido , Humanos , Pré-Escolar , Estudos Prospectivos , Encéfalo/diagnóstico por imagem , Recém-Nascido de muito Baixo Peso
11.
AJR Am J Roentgenol ; 222(4): e2330695, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38230903

RESUMO

MRI is increasingly used as an alternate to CT for the evaluation of suspected appendicitis in pediatric patients presenting to the emergency department (ED) with abdominal pain, when further imaging is needed after an initial ultrasound examination. The available literature shows a similar diagnostic performance of MRI and CT in this setting. At the authors' institution, to evaluate for appendicitis in children in the ED, MRI is performed using a rapid three-sequence free-breathing protocol without IV contrast media. Implementation of an MRI program for appendicitis in children involves multiple steps, including determination of imaging resource availability, collaboration with other services to develop imaging pathways, widespread educational efforts, and regular quality review. Such programs can face numerous practice-specific challenges, such as those involving scanner capacity, costs, and buy-in of impacted groups. Nonetheless, through careful consideration of these factors, MRI can be used to positively impact the care of children presenting to the ED with suspected appendicitis. This Clinical Perspective aims to provide guidance on the development of a program for appendicitis MRI in children, drawing on one institution's experience while highlighting the advantages of MRI and practical strategies for overcoming potential barriers.


Assuntos
Apendicite , Imageamento por Ressonância Magnética , Criança , Humanos , Apendicite/diagnóstico por imagem , Serviço Hospitalar de Emergência , Hospitais Pediátricos , Imageamento por Ressonância Magnética/métodos
12.
AJR Am J Roentgenol ; 222(1): e2329640, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37530396

RESUMO

BACKGROUND. The Fontan operation palliates single-ventricle congenital heart disease but causes hepatic congestion with associated progressive hepatic fibrosis. OBJECTIVE. The purpose of this study was to evaluate associations between liver stiffness measured using ultrasound (US) shear-wave elastography (SWE) in patients with Fontan palliation and the occurrence of portal hypertension and Fontan circulatory failure during follow-up. METHODS. This retrospective study included 119 individuals 10 years old or older (median age, 19.1 years; 61 female patients, 58 male patients) with Fontan circulation who underwent liver US with 2D SWE from January 1, 2015, to January 1, 2022, and had 1 year or more of clinical follow-up (unless experiencing earlier outcome-related events). Median liver stiffness from the initial US examination was documented. Varices, ascites, splenomegaly, and thrombocytopenia (VAST) scores (range, 0-4) were determined as a marker of portal hypertension on initial US examination and 1 year or more of follow-up imaging (US, CT, or MRI). Composite clinical outcome for Fontan circulatory failure (death, mechanical circulatory support, cardiac transplant, or unexpected Fontan circulation-related hospitalization) was assessed. Analysis included the Wilcoxon rank sum test, logistic regression analysis with stepwise variable selection, and ROC analysis. RESULTS. Median initial liver stiffness was 2.22 m/s. Median initial VAST score was 0 (IQR, 0-1); median follow-up VAST score was 1 (IQR, 0-2) (p = .004). Fontan circulatory failure occurred in 37 of 119 (31%) patients (median follow-up, 3.4 years). Initial liver stiffness was higher in patients with a follow-up VAST score of 1 or greater (2.37 m/s) than in those with a follow-up VAST score of 0 (2.08 m/s) (p = .005), and initial liver stiffness was higher in patients with (2.43 m/s) than without (2.10 m/s) Fontan circulatory failure during follow-up (p < .001). Initial liver stiffness was the only significant independent predictor of Fontan circulatory failure (OR = 3.76; p < .001); age, sex, Fontan operation type, dominant ventricular morphology, and initial VAST score were not independent predictors. Initial liver stiffness had an AUC of 0.70 (sensitivity, 79%; specificity, 57%; threshold, > 2.11 m/s) for predicting a follow-up VAST score of 1 or greater and an AUC of 0.74 (sensitivity, 84%; specificity, 52%; threshold, > 2.12 m/s) for predicting Fontan circulatory failure. CONCLUSION. In patients with Fontan circulation, increased initial liver stiffness was associated with portal hypertension and circulatory failure during follow-up, although it had moderate performance in predicting these outcomes. CLINICAL IMPACT. US SWE may play a role in post-Fontan surveillance, supporting tailored medical and surgical care.


Assuntos
Técnicas de Imagem por Elasticidade , Técnica de Fontan , Hipertensão Portal , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Criança , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Ascite/patologia , Fígado/diagnóstico por imagem , Cirrose Hepática/patologia
13.
AJR Am J Roentgenol ; 222(1): e2329812, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37530398

RESUMO

BACKGROUND. Radiologists have variable diagnostic performance and considerable interreader variability when interpreting MR enterography (MRE) examinations for suspected Crohn disease (CD). OBJECTIVE. The purposes of this study were to develop a machine learning method for predicting ileal CD by use of radiomic features of ileal wall and mesenteric fat from noncontrast T2-weighted MRI and to compare the performance of the method with that of expert radiologists. METHODS. This single-institution study included retrospectively identified patients who underwent MRE for suspected ileal CD from January 1, 2020, to January 31, 2021, and prospectively enrolled participants (patients with newly diagnosed ileal CD or healthy control participants) from December 2018 to October 2021. Using axial T2-weighted SSFSE images, a radiologist selected two slices showing greatest terminal ileal wall thickening. Four ROIs were segmented, and radiomic features were extracted from each ROI. After feature selection, support-vector machine models were trained to classify the presence of ileal CD. Three fellowship-trained pediatric abdominal radiologists independently classified the presence of ileal CD on SSFSE images. The reference standard was clinical diagnosis of ileal CD based on endoscopy and biopsy results. Radiomic-only, clinical-only, and radiomic-clinical ensemble models were trained and evaluated by nested cross-validation. RESULTS. The study included 135 participants (67 female, 68 male; mean age, 15.2 ± 3.2 years); 70 were diagnosed with ileal CD. The three radiologists had accuracies of 83.7% (113/135), 88.1% (119/135), and 86.7% (117/135) for diagnosing CD; consensus accuracy was 88.1%. Interradiologist agreement was substantial (κ = 0.78). The best-performing ROI was bowel core (AUC, 0.95; accuracy, 89.6%); other ROIs had worse performance (whole-bowel AUC, 0.86; fat-core AUC, 0.70; whole-fat AUC, 0.73). For the clinical-only model, AUC was 0.85 and accuracy was 80.0%. The ensemble model combining bowel-core radiomic and clinical models had AUC of 0.98 and accuracy of 93.5%. The bowel-core radiomic-only model had significantly greater accuracy than radiologist 1 (p = .009) and radiologist 2 (p = .02) but not radiologist 3 (p > .99) or the radiologists in consensus (p = .05). The ensemble model had greater accuracy than the radiologists in consensus (p = .02). CONCLUSION. A radiomic machine learning model predicted CD diagnosis with better performance than two of three expert radiologists. Model performance improved when radiomic data were ensembled with clinical data. CLINICAL IMPACT. Deployment of a radiomic-based model including T2-weighted MRI data could decrease interradiologist variability and increase diagnostic accuracy for pediatric CD.


Assuntos
Doença de Crohn , Doenças do Íleo , Criança , Humanos , Masculino , Feminino , Adolescente , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Radiômica , Aprendizado de Máquina
14.
Inflamm Bowel Dis ; 30(3): 402-409, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37229656

RESUMO

BACKGROUND: Intestinal ultrasound (IUS) is a noninvasive tool to assess bowel inflammation. There is a paucity of data on its accuracy in pediatric patients. AIM: The aim of this study is to evaluate the diagnostic performance of bowel wall thickness (BWT) measured using IUS compared with endoscopic disease activity in children suspected of having inflammatory bowel disease (IBD). METHODS: We conducted a single-center cross-sectional pilot study of pediatric patients suspected to have previously undiagnosed IBD. Endoscopic inflammation was graded using segmental scores of the Simple Endoscopic Score for Crohn's Disease (SES-CD) and the Ulcerative Colitis Endoscopic Index of Severity (UCEIS) and classified as having healthy, mild, or moderate/severe disease activity. Association between BWT and endoscopic severity was assessed using the Kruskal-Wallis test. The diagnostic performance of BWT to detect active disease at endoscopy was evaluated using the area under the receiver operating characteristic curve; sensitivity and specificity were calculated. RESULTS: In all, 174 bowel segments in 33 children were assessed by IUS and ileocolonoscopy. An elevated median BWT was associated with increased bowel segment disease severity, classified by the SES-CD (P < .001) and the UCEIS (P < .01). Using a cutoff value of 1.9 mm, we found that the BWT had an area under the receiver operating characteristic curve of 0.743 (95% CI, 0.67-0.82), a sensitivity of 64% (95% CI, 53%-73%), and a specificity of 76% (95% CI, 65%-85%) to detect inflamed bowel. CONCLUSION: Increasing BWT is associated with increasing endoscopic activity in pediatric IBD. Our study suggests that the optimal BWT cutoff value for detecting active disease may be less than that seen in adults. Additional pediatric studies are needed.


Increasing bowel wall thickness (BWT) is associated with increasing IBD endoscopic scores on colonoscopy. There is moderate to fair agreement between the prediction of IBD diagnosis and Paris classification using intestinal ultrasound (IUS). Bowel wall thickness cutoff values to detect inflamed bowel segments are likely lower for children with IBD than for adults, although further studies with wider age ranges are needed to confirm this finding.


Assuntos
Colite Ulcerativa , Doenças Inflamatórias Intestinais , Adulto , Humanos , Criança , Estudos Transversais , Projetos Piloto , Colite Ulcerativa/diagnóstico por imagem , Inflamação , Gravidade do Paciente
15.
AJR Am J Roentgenol ; 222(2): e2330422, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38054957

RESUMO

MR enterography (MRE) protocols used in patients with Crohn disease are burdened by long acquisition time, high cost, and suboptimal patient experience. For several indications, highly diagnostic MRE can be performed in five or fewer sequences, without IV contrast material or antiperistaltic medication and with an examination room time of less than 12 minutes. As such, MRE could be more patient friendly, more frequently performed, and require fewer health care resources.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
16.
AJR Am J Roentgenol ; 222(2): e2330345, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37991333

RESUMO

BACKGROUND. Although primary lung cancer is rare in children, chest CT is commonly performed to assess for lung metastases in children with cancer. Lung nodule computer-aided detection (CAD) systems have been designed and studied primarily using adult training data, and the efficacy of such systems when applied to pediatric patients is poorly understood. OBJECTIVE. The purpose of this study was to evaluate in children the diagnostic performance of traditional and deep learning CAD systems trained with adult data for the detection of lung nodules on chest CT scans and to compare the ability of such systems to generalize to children versus to other adults. METHODS. This retrospective study included pediatric and adult chest CT test sets. The pediatric test set comprised 59 CT scans in 59 patients (30 boys, 29 girls; mean age, 13.1 years; age range, 4-17 years), which were obtained from November 30, 2018, to August 31, 2020; lung nodules were annotated by fellowship-trained pediatric radiologists as the reference standard. The adult test set was the publicly available adult Lung Nodule Analysis (LUNA) 2016 subset 0, which contained 89 deidentified scans with previously annotated nodules. The test sets were processed through the traditional FlyerScan (github.com/rhardie1/FlyerScanCT) and deep learning Medical Open Network for Artificial Intelligence (MONAI; github.com/Project-MONAI/model-zoo/releases) lung nodule CAD systems, which had been trained on separate sets of CT scans in adults. Sensitivity and false-positive (FP) frequency were calculated for nodules measuring 3-30 mm; nonoverlapping 95% CIs indicated significant differences. RESULTS. Operating at two FPs per scan, on pediatric testing data FlyerScan and MONAI showed significantly lower detection sensitivities of 68.4% (197/288; 95% CI, 65.1-73.0%) and 53.1% (153/288; 95% CI, 46.7-58.4%), respectively, than on adult LUNA 2016 subset 0 testing data (83.9% [94/112; 95% CI, 79.1-88.0%] and 95.5% [107/112; 95% CI, 90.0-98.4%], respectively). Mean nodule size was smaller (p < .001) in the pediatric testing data (5.4 ± 3.1 [SD] mm) than in the adult LUNA 2016 subset 0 testing data (11.0 ± 6.2 mm). CONCLUSION. Adult-trained traditional and deep learning-based lung nodule CAD systems had significantly lower sensitivity for detection on pediatric data than on adult data at a matching FP frequency. The performance difference may relate to the smaller size of pediatric lung nodules. CLINICAL IMPACT. The results indicate a need for pediatric-specific lung nodule CAD systems trained on data specific to pediatric patients.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Masculino , Adulto , Feminino , Humanos , Criança , Pré-Escolar , Adolescente , Inteligência Artificial , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão , Computadores , Nódulo Pulmonar Solitário/diagnóstico por imagem , Sensibilidade e Especificidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
17.
Inflamm Bowel Dis ; 30(3): 357-369, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37524088

RESUMO

BACKGROUND: Perianal fistulas and abscesses occur commonly as complications of pediatric Crohn's disease (CD). A validated imaging assessment tool for quantification of perianal disease severity and activity is needed to evaluate treatment response. We aimed to identify magnetic resonance imaging (MRI)-based measures of perianal fistulizing disease activity and study design features appropriate for pediatric patients. METHODS: Seventy-nine statements relevant to MRI-based assessment of pediatric perianal fistulizing CD activity and clinical trial design were generated from literature review and expert opinion. Statement appropriateness was rated by a panel (N = 15) of gastroenterologists, radiologists, and surgeons using modified RAND/University of California Los Angeles appropriateness methodology. RESULTS: The modified Van Assche Index (mVAI) and the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD) were considered appropriate instruments for use in pediatric perianal fistulizing disease clinical trials. Although there was concern regarding the use of intravascular contrast material in pediatric patients, its use in clinical trials was considered appropriate. A clinically evident fistula tract and radiologic disease defined as at least 1 fistula or abscess on pelvic MRI were considered appropriate trial inclusion criteria. A coprimary clinical and radiologic end point and inclusion of a patient-reported outcome were also considered appropriate. CONCLUSION: Outcomes of treatment of perianal fistulizing disease in children must include MRI. Existing multi-item measures, specifically the mVAI and MAGNIFI-CD, can be adapted and used for children. Further research to assess the operating properties of the indices when used in a pediatric patient population is ongoing.


Assuntos
Doença de Crohn , Fístula , Criança , Humanos , Abscesso , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ensaios Clínicos como Assunto
18.
Acad Radiol ; 31(3): 1102-1110, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37863782

RESUMO

RATIONALE AND OBJECTIVES: Rationale MRI is increasingly used for diagnosis of pediatric appendicitis in the emergency care setting. Scan and room time are important to optimize workflow, especially in situations with limited MRI availability and accessibility. To describe our process to optimize and implement a rapid, non-contrast, free-breathing MRI protocol for appendicitis and to characterize the accuracy for diagnosis. MATERIALS AND METHODS: Initial MRI protocol implemented for suspected appendicitis included five respiratory-triggered axial and coronal single shot fast spin echo (SSFSE) and radial T2W sequences with and without fat suppression (FS). This protocol was reassessed based on image quality. Subsequently, the coronal and axial T2W SSFSE FS sequence were removed. A three-sequence exam comprised the rapid MRI appendicitis protocol used for the remainder of the study. All examinations were performed on a 1.5 T scanner. For all examinations, the following information was obtained: scan time, diagnosis of appendicitis (by radiology report), surgery and pathology reports, and alternative diagnoses documented in radiology reports. MRI examination scan durations were compared between the five-sequence and three-sequence protocols, with Mann-Whitney U test, and proportions of false diagnoses were compared to Fisher's exact test. RESULTS: 216 examinations were performed; 21 and 195 performed with five- and three-sequence protocol, respectively. The median duration of the five-sequence protocol was 20 (16.9-23.5) minutes vs.11 (9.5-13) minutes for the three sequence protocol (p < 0.0001). The majority (n = 157, 80.5% of 195) of examinations were performed in a goal time of< 15 min. 23 examinations took longer than 20 min (n = 12, n = 11 for the three- and five-sequence protocols, respectively) were due to repeat sequences or addition of non-standard sequences (requested by interpreting radiologist). 27 (90%) of the 30 reported positive cases were confirmed by pathology. There were three false-positive diagnoses (all three-sequence protocol exams) and one false-negative diagnosis (five-sequence protocol exam). Alternative diagnoses, including pancreatitis, omental infarct, masses, and ovarian pathology, were made in 42 (19%) cases. CONCLUSION: A three-sequence, non-contrast, free- breathing MRI examination can be performed in less than 15 min in the emergency department and has high diagnostic accuracy for acute appendicitis in children and young adults.


Assuntos
Apendicite , Adulto Jovem , Humanos , Criança , Apendicite/diagnóstico por imagem , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Serviço Hospitalar de Emergência , Respiração , Estudos Retrospectivos
19.
Curr Probl Diagn Radiol ; 53(1): 154-165, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37891088

RESUMO

Catheter-based angiography is regarded as the clinical reference imaging technique for vessel imaging; however, it is invasive and is currently used for intervention or physiologic measurements. Contrast enhanced magnetic resonance angiography (MRA) with gadolinium-based contrast agents can be performed as a three-dimensional (3D) MRA or as a time resolved 3D (4D) MRA without physiologic synchronization, in which case cardiac and respiratory motion may blur the edges of the vessels and cardiac chambers. Ferumoxytol has recently been a popular contrast agent for MRA in patients with chronic renal failure. Noncontrast 3D MRA with ECG gating and respiratory navigation are safe and accurate noninvasive cross-sectional imaging techniques for the visualization of great vessels of the heart and coronary arteries in a variety of cardiovascular disorders including complex congenital heart diseases. Noncontrast flow dependent MRA techniques such as time of flight, phase contrast, and black-blood MRA techniques can be used as complementary or primary techniques. Here we review both conventional and relatively new contrast enhanced and non-contrast enhanced MRA techniques including ferumoxytol enhanced MRA, and bright-blood and water-fat separation based noncontrast 3D MRA techniques.


Assuntos
Óxido Ferroso-Férrico , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Meios de Contraste , Coração , Imageamento por Ressonância Magnética , Imageamento Tridimensional/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...