Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38837309

RESUMO

Randomized clinical trials failed to show additional benefit of renal artery stenting on top of medical therapy. Instead of writing an obituary on renal artery stenting, we try to explain these disappointing results. A transstenotic pressure gradient is needed to reduce renal perfusion and to activate the renin-angiotensin-aldosterone system. In only a minority of patients included in trials, a transstenotic pressure gradient is measured and reported. Like the coronary circulation, integration of physiological lesion assessment will allow to avoid stenting of non-significant lesions and select those patients that are most likely to benefit from renal artery stenting. Renal artery interventions are associated with peri-procedural complications. Contemporary techniques, including radial artery access, no-touch technique to engage the renal ostium and the use of embolic protection devices, will minimize procedural risk. Combining optimal patient selection and meticulous technique might lead to a netto clinical benefit when renal artery stenting is added to optimal medical therapy.

2.
Catheter Cardiovasc Interv ; 104(1): 92-96, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38686525

RESUMO

The double-kiss mini-crush (DKMC) technique has been successfully deployed in the past for the treatment of complex coronary lesions even for left main lesions. Our case report consists of a proof-of-principle that the DKMC technique can be successfully translated as well to the field of complex renal artery lesions. Insightful thinking out-of-the "coronary" box in concert with skillful off-label application of coronary stenting procedures may open the gate for unprecedented opportunities for the treatment of difficult-to-tackle in-stent restenosis in the renal circulation.


Assuntos
Recidiva , Obstrução da Artéria Renal , Stents , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Obstrução da Artéria Renal/fisiopatologia , Obstrução da Artéria Renal/etiologia , Resultado do Tratamento , Masculino , Angioplastia com Balão/instrumentação , Grau de Desobstrução Vascular , Idoso , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia
3.
J Invasive Cardiol ; 35(5): E234-E247, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37219850

RESUMO

OBJECTIVES: This study aimed to assess discordance between results of instantaneous wave-free ratio (iFR), fractional flow reserve (FFR), and intravascular ultrasound (IVUS) in intermediate left main coronary (LM) lesions, and its impact on clinical decision making and outcome. METHODS: We enrolled 250 patients with a 40%-80% LM stenosis in a prospective, multicenter registry. These patients underwent both iFR and FFR measurements. Of these, 86 underwent IVUS and assessment of the minimal lumen area (MLA), with a 6 mm2 cutoff for significance. RESULTS: Isolated LM disease was recognized in 95 patients (38.0%), while 155 patients (62.0%) had both LM disease and downstream disease. In 53.2% of iFR+ and 56.7% of FFR+ LM lesions, the measurement was positive in only one daughter vessel. iFR/FFR discordance occurred in 25.0% of patients with isolated LM disease and 36.2% of patients with concomitant downstream disease (P=.049). In patients with isolated LM disease, discordance was significantly more common in the left anterior descending artery and younger age was an independent predictor of iFR-/FFR+ discordance. iFR/MLA and FFR/MLA discordance occurred in 37.0% and 29.4%, respectively. Within 1 year of follow-up, major cardiac adverse events (MACE) occurred in 8.5% and 9.7% (P=.763) of patients whose LM lesion was deferred or revascularized, respectively. Discordance was not an independent predictor of MACE. CONCLUSIONS: Current methods of estimating LM lesion significance often yield discrepant findings, complicating therapeutic decision-making.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Humanos , Estudos Prospectivos , Tomada de Decisão Clínica , Constrição Patológica , Sistema de Registros
4.
Acad Radiol ; 30 Suppl 1: S286-S294, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37120404

RESUMO

RATIONALE AND OBJECTIVES: To investigate the renal pressure-flow relationship and its relation to renin release, because the renal perfusion pressure below which renal flow starts to decline and renin secretion is upregulated is unclear. MATERIALS AND METHODS: A porcine model of graded unilateral renal artery stenosis was created. The severity of the stenosis was expressed as the ratio between distal renal pressure (Pd) and aortic pressure (Pa). Pd and renal flow velocity were continuously measured using a combined pressure-flow wire (Combowire®). Hemodynamic measurements and blood sampling for renin, angiotensin and aldosterone were performed in baseline conditions and during progressive balloon inflation in the renal artery leading to Pd decrease per 5% increment. Resistive index (RI) was computed as (1 - (End Diastolic V/Peak Systolic V))*100. RESULTS: For a 5% decrease in renal perfusion pressure (95% of aortic pressure or 5% decrease compared to Pa), peak systolic velocity started to decrease. A significant decrease in average peak flow velocity was observed when distal renal perfusion pressure decreased by 25% and was associated with activation of ipsilateral renin secretion. The RI decreased already for minimal changes in Pd/Pa ratio. CONCLUSION: In an animal model of unilateral graded renal artery stenosis, a 25% decrease in perfusion pressure results in a significant decrease in distal renal flow, causing upregulation of renin secretion.


Assuntos
Hipertensão Renovascular , Obstrução da Artéria Renal , Animais , Suínos , Obstrução da Artéria Renal/diagnóstico por imagem , Hipertensão Renovascular/diagnóstico por imagem , Hipertensão Renovascular/complicações , Renina , Pressão Sanguínea , Hemodinâmica
5.
Eur Heart J Digit Health ; 3(4): 548-558, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36710895

RESUMO

Aims: In this study, we compare the diagnostic accuracy of a standard 12-lead electrocardiogram (ECG) with a novel 13-lead ECG derived from a self-applicable 3-lead ECG recorded with the right exploratory left foot (RELF) device. The 13th lead is a novel age and sex orthonormalized computed ST (ASO-ST) lead to increase the sensitivity for detecting ischaemia during acute coronary artery occlusion. Methods and results: A database of simultaneously recorded 12-lead ECGs and RELF recordings from 110 patients undergoing coronary angioplasty and 30 healthy subjects was used. Five cardiologists scored the learning data set and five other cardiologists scored the validation data set. In addition, the presence of non-ischaemic ECG abnormalities was compared. The accuracy for detection of myocardial supply ischaemia with the derived 12 leads was comparable with that of the standard 12-lead ECG (P = 0.126). By adding the ASO-ST lead, the accuracy increased to 77.4% [95% confidence interval (CI): 72.4-82.3; P < 0.001], which was attributed to a higher sensitivity of 81.9% (95% CI: 74.8-89.1) for the RELF 13-lead ECG compared with a sensitivity of 76.8% (95% CI: 71.9-81.7; P < 0.001) for the 12-lead ECG. There was no significant difference in the diagnosis of non-ischaemic ECG abnormalities, except for Q-waves that were more frequently detected on the standard ECG compared with the derived ECG (25.9 vs. 13.8%; P < 0.001). Conclusion: A self-applicable and easy-to-use 3-lead RELF device can compute a 12-lead ECG plus an ischaemia-specific 13th lead that is, compared with the standard 12-lead ECG, more accurate for the visual diagnosis of myocardial supply ischaemia by cardiologists.

6.
Catheter Cardiovasc Interv ; 97(4): 646-655, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32548976

RESUMO

OBJECTIVES: The study aimed to demonstrate through instant wave-free ratio (iFR) measurements that myocardium distal to a chronic total occlusion (CTO) is ischemic, that ischemia is reversible by PCI, and that iFR assessment after PCI can be used to optimize PCI results. BACKGROUND: The greatest benefit of revascularization is found in patients with low fractional flow reserve. In patients with CTOs, iFR measurement may be more appropriate to evaluate ischemia as it does not require maximal microvascular vasodilation, which may be hampered by microvascular dysfunction. METHODS: The iFR was measured in 81 CTO patients, both pre- and post-PCI in 63 patients, and only post-PCI in the following 18 patients. A pressure wire pullback was performed post-PCI if iFR ≤0.89. RESULTS: The first 63 patients all had significant ischemia distal to the CTO with a median iFR of 0.33 [0.22; 0.44], improving significantly post-PCI to a median iFR of 0.93 [0.89;0.96] (p < .001). In the complete cohort, the median iFR post-PCI was 0.93 [0.86;0.96] but still ≤0.89 in 23 patients (30%). 12 of these patients had further PCI optimization because of a residual focal pressure gradient on pullback, after which only two had a final iFR ≤0.89. CONCLUSIONS: In CTO patients with an indication for PCI, iFR consistently demonstrated profound myocardial ischemia. Successful PCI immediately relieved ischemia in 70% of patients. In the remaining 30% of cases, a manual iFR pullback proved helpful in guiding further optimization of the PCI result.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Cateterismo Cardíaco , Angiografia Coronária , Humanos , Isquemia , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Resultado do Tratamento
7.
Acta Cardiol ; 76(10): 1043-1051, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32755286

RESUMO

BACKGROUND: To chart the evolution of the CTO-PCI landscape in Belgium and Luxembourg, the Belgian Working Group on Chronic Total Occlusions (BWGCTO) was established in 2016. METHODS: Between May 2016 and December 2019, patients undergoing a CTO-PCI treatment were prospectively and consecutively enrolled. Twenty-one centres in Belgium and one in Luxembourg participated. Individual operators had mixed levels of expertise in treating CTO lesions. Demographic, angiographic, procedural parameters and incidence of major adverse cardiac and cerebrovascular events (MACCE) were systematically registered. RESULTS: Over a four-year enrolment period, 1832 procedures were performed in 1733 patients achieving technical success in 1474 cases (80%), with an in-hospital MACCE rate of 2.3%. Fifty-nine (3%) cases were re-attempt procedures of which 41 (69%) were successful. High-volume centres treated more complex lesions (mean J-CTO score: 2.15 ± 1.21) as compared to intermediate (mean J-CTO score: 1.72 ± 1.23; p < 0.001) and low-volume centres (mean J-CTO score: 0.99 ± 1.21; p = 0.002). Despite this, success rates did not differ between centres (p = 0.461). Overall success rates did not differ over time (p = 0.810). High-volume centres progressively tackled more complex CTOs while keeping success rates stable. In all centres, the most applied strategy was antegrade wire escalation (83%). High-volume centres more often successfully applied antegrade dissection and re-entry and retrograde techniques in lesions with higher complexity. CONCLUSION: With variable experience levels, operators treated CTOs with high success and relatively few complications. Although AWE remains the most used technique, it is paramount for operators to be skilled in all contemporary techniques in order to be successful in more complex CTOs.


Assuntos
Intervenção Coronária Percutânea , Doenças Vasculares , Angiografia , Bélgica/epidemiologia , Humanos , Luxemburgo/epidemiologia
8.
J Am Heart Assoc ; 9(13): e014683, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32605408

RESUMO

Background Dual axis rotational coronary angiography (DARCA) reduces radiation exposure during coronary angiography on older x-ray systems. The purpose of the current study is to quantify patient and staff radiation exposure using DARCA on a modality already equipped with dose-reducing technology. Additionally, we assessed applicability of 1 dose area product to effective dose conversion factor for both DARCA and conventional coronary angiography (CCA) procedures. Methods and Results Twenty patients were examined using DARCA and were compared with 20 age-, sex-, and body mass index-matched patients selected from a prior study using CCA on the same x-ray modality. All irradiation events are simulated using PCXMC (STUK, Finland) to determine organ and effective doses. Moreover, for DARCA each frame is simulated. Staff dose is measured using active personal dosimeters (DoseAware, Philips Healthcare, The Netherlands). With DARCA, median cumulative dose area product is reduced by 57% (ie, 7.41 versus 17.19 Gy·cm2). Effective dose conversion factors of CCA and DARCA are slightly different, yet this difference is not statistically significant. The occupational dose at physician's chest, leg, and collar level are reduced by 60%, 56%, and 16%, respectively, of which the first 2 reached statistical significance. Median effective dose is reduced from 4.75 mSv in CCA to 2.22 mSv in DARCA procedures, where the latter is further reduced to 1.79 mSv when excluding ventriculography. Conclusions During invasive coronary angiography, DARCA reduces radiation exposure even further toward low-dose values on a system already equipped with advanced image processing and noise reduction algorithms. For both DARCA and CCA procedures, using 1 effective dose conversion factor of 0.30 mSv·Gy-1·cm-2 is feasible.


Assuntos
Algoritmos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Segurança do Paciente , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos
9.
Am J Cardiol ; 126: 56-65, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32340713

RESUMO

Recent MitraClip heart failure (HF) trials suggest that baseline left ventricular (LV) remodeling may be critical for patient selection. We, therefore, investigated whether baseline LV remodeling affects safety, efficacy, and clinical outcomes in HF patients with symptomatic secondary mitral regurgitation (MR) undergoing percutaneous mitral valve repair using MitraClip. LV remodeling was assessed by LV end-systolic dimension index (LVESDi) on transthoracic baseline echocardiography. Early and late outcome was reported using Mitral Valve Academic Research Consortium-criteria. A total of 107 consecutive HF patients (73 ± 10 years, 70% male) who underwent MitraClip intervention for secondary MR were studied. The study population was stratified by median LVESDi between nonadvanced (<28 mm/m², n = 49) and advanced LV remodeling (≥28 mm/m², n = 58). Both groups had similar acute procedural success, in hospital bleeding and nonbleeding complications and significant improvement in MR severity and symptoms, sustained up to 36 months (all p >0.05). LVESDi, but not LV end-diastolic diameter index nor LV ejection fraction, independently related to HF hospitalization (hazard ratio 1.11, 95% confidence interval 1.05 to 1.16, p <0.001) and mortality (hazard ratio 1.11, 95% confidence interval 1.06 to 1.17, p <0.001). At 1 and 3 years, survival free of HF hospitalization was higher in patients without versus with advanced LV remodeling (89% vs 66% and 65% vs 37%, p = 0.002) and mortality was lower (9% vs 24% and 36% vs 47%, p = 0.074), respectively. Annual HF hospitalization rate only decreased in the nonadvanced LV remodeling group (-43%, p = 0.025). Advanced LV remodeling, assessed by LVESDi, in HF patients who underwent MitraClip therapy does not influence therapeutic safety nor efficacy, but implies increased HF hospitalization and mortality risk. This parameter may be valuable for MitraClip therapy patient selection.


Assuntos
Insuficiência Cardíaca/complicações , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Próteses e Implantes , Remodelação Ventricular , Idoso , Bélgica/epidemiologia , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Sistema de Registros , Sístole
10.
Angiology ; 70(5): 407-413, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30654619

RESUMO

In Europe, the prevalence of abdominal aortic aneurysms (AAAs) in the elderly population (≥65 year old) has declined in the past decades to <4%. Aneurysmal degeneration of the aorta is a serious and potentially life-threatening vascular disease. Abdominal aortic aneurysms typically develop subclinically and often only become symptomatic when complicated by impending rupture. Most AAAs are discovered incidentally while investigating for an unrelated pathology. Ruptured AAA is the tenth leading cause of death in Belgium (0.32% of all deaths in 2014). Health-care providers have emphasized the importance of early detection of AAA and elective repair when the rupture risk outweighs operative risk (usual diameter threshold of 55 mm). Routine AAA screening programs, consisting of a single abdominal ultrasonography at the age of 65 years, aim to reduce the number of AAA-related deaths. Does population-based ultrasound screening for AAA achieve its objective and is it cost-effective? This literature review tries to answer these challenging questions.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Programas de Rastreamento/métodos , Ultrassonografia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/economia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/terapia , Ruptura Aórtica/economia , Ruptura Aórtica/mortalidade , Ruptura Aórtica/terapia , Análise Custo-Benefício , Diagnóstico Precoce , Feminino , Custos de Cuidados de Saúde , Humanos , Expectativa de Vida , Masculino , Programas de Rastreamento/economia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Prognóstico , Medição de Risco , Fatores de Risco , Fatores Sexuais , Ultrassonografia/economia
11.
Lancet Digit Health ; 1(2): e90-e99, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-33323233

RESUMO

BACKGROUND: Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. METHODS: In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory self-recordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. FINDINGS: From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81·0-95·6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0·96 (0·95-0·97). The mean false positive rate during daily life conditions was 4·19% (95% CI 3·29-5·10). The sensitivity for the target conditions was 0·87 (55 of 63; 95% CI 0·77-0·93) for acute coronary artery occlusion, 0·95 (54 of 57; 0·86-0·98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1·00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p<0·0001). The proportion of total variation in study estimates due to heterogeneity between patients (I2) was low (12·6%). The area under the receiver operator characteristics curve was 0·973 (95% CI 0·956-0·990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. INTERPRETATION: Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. FUNDING: Ghent University, Industrial Research Fund.


Assuntos
Computadores de Mão , Doença da Artéria Coronariana , Oclusão Coronária , Pacientes Ambulatoriais , Bélgica , Oclusão Coronária/diagnóstico , Oclusão Coronária/mortalidade , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Sensibilidade e Especificidade
12.
J Interv Cardiol ; 31(6): 807-814, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30168209

RESUMO

INTRODUCTION: Cardiac catheterization procedures result in high patient radiation exposure and corresponding staff doses are reported to be among the highest for medical staff. The purpose of current randomized controlled study was to quantify the potential radiation dose reduction for both patient and staff, enabled by recent X-ray technology. This technology is equipped with advanced image processing algorithms, real-time dose monitoring, and an acquisition chain optimized for cardiac catheterization applications. METHODS: A total of 122 adult patients were randomly assigned to one of two cath labs, either the reference X-ray modality (Allura Xper FD10, Philips Healthcare, the Netherlands) or the new X-ray system (AlluraClarity FD20/10 Philips Healthcare, the Netherlands). Exposure parameters and staff dosimeter readings were recorded for each exposure. Technical measurements were performed to define the radiation scatter behavior. RESULTS: With the newer equipment, patient radiation dose is reduced (as total dose-area product) by 67% based on geometric means with 95%CI of 53%, 77% for diagnostic and interventional procedures. The C-arm and leg dosimeter readings were both reduced with 65% (P < 0.001), while for the collar and chest dosimeter readings no statistically significant reduction was noticed. CONCLUSION: The new x-ray and image processing technology, significantly reduces patient dose in coronary angiographies, and PCIs by 67%. In general, scatter dose was also reduced, yet for some dosimeters the reduction was limited and not statistically significant. This study clearly indicates that the scatter behavior is highly dependent on C-arm rotation, operator movement and height, dosimeter position, beam filtration, clinical procedure type and system geometry.


Assuntos
Cateterismo Cardíaco/instrumentação , Angiografia Coronária/instrumentação , Exposição Ocupacional/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/estatística & dados numéricos , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Dosímetros de Radiação , Fatores de Risco , Raios X
13.
EuroIntervention ; 13(13): 1603-1611, 2018 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-28966159

RESUMO

AIMS: This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. METHODS AND RESULTS: Between June 2009 and November 2016, 457 consecutive patients (63% male, 75±12 yrs, CHA2DS2-VASc 4±0.6, HAS-BLED 3.5±0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 patient-years, median follow-up 370 days), the actual annual stroke rate was 1.2%, lower than the expected stroke risk of 4% (70% reduction). The observed bleeding rate was 2%, while the calculated risk was 3.7% (46% reduction). Kaplan-Meier analysis showed a similar overall survival (93±2% and 87±3% versus 91±3% and 87±4%; p=0.35) and event-free survival (92±2% and 84±3% versus 88±3% and 80±5%; p=0.17) at one and two years, for the ACP/Amulet versus the WATCHMAN groups of patients, respectively. CONCLUSIONS: The data from the Belgian left atrial appendage occlusion registry suggest that the procedure is effective and relatively safe in a real-world setting, using either the WATCHMAN or the ACP/Amulet device.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Bélgica , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
Acta Cardiol ; 73(5): 427-436, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29183248

RESUMO

Background: Important developments in materials, devices, and techniques have improved outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI), and resulted in a growing interest in CTO-PCI. The Belgian Working Group on Chronic Total Occlusions (BWGCTO) working group aims to assess the evolution within the CTO-PCI landscape over the next years. Methods: From May 2016 onwards, patients undergoing CTO-PCI were included in the BWGCTO registry by 15 centres in Belgium and Luxemburg. Baseline, angiographic, and procedural data were collected. Here, we report on the one-year in-hospital outcomes. Results: Over the course of one year, 411 procedures in 388 patients were included with a mean age of 64 ± 11 years. The majority were male (81%). Relatively complex CTOs were treated (Japanese CTO score =2.2 ± 1.2) with a high procedure success rate (82%). Patient- and lesion-wise success rates were 83 and 85%, respectively. Major adverse in-hospital events were acceptably low (3.4%). Antegrade wire escalation technique was applied most frequently (82%). On the other hand, antegrade dissection and re-entry and retrograde strategies were more frequently applied in higher volume centres and successful for lesions with higher complexity. Conclusion: Satisfactory procedural outcomes and a low rate of adverse events were obtained in a complex CTO population, treated by operators with variable experience levels. Antegrade wire escalation was the preferred strategy, regardless of operator volume.


Assuntos
Intervenção Coronária Percutânea , Bélgica , Feminino , Humanos , Luxemburgo , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
15.
Acta Cardiol ; 72(6): 599-609, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28657457

RESUMO

Spontaneous coronary artery dissection or SCAD is a rare and challenging disease that is increasingly diagnosed. It is characterized by a non-traumatic, non-iatrogenic separation of the coronary artery wall and occurs predominantly in young and middle-aged women without traditional cardiovascular risk factors. SCAD is often associated with predisposing conditions such as the peripartum period, systemic inflammatory disease and heritable connective tissue disease. More recently, independent investigators have demonstrated an important association with fibromuscular dysplasia. Extreme emotional or physical stress as well as intense hormonal therapy or drug abuse have been pointed out as precipitating factors. The diagnosis of SCAD can be challenging and starts with clinical suspicion. Advanced imaging techniques such as intravascular ultrasound and optical coherence tomography are useful for the differentiation from atherosclerotic disease and are increasingly used for this indication. The proposed treatment in the acute setting is based on findings from single-centre retrospective series: in stable patients with a TIMI-flow ≥2 a conservative management is proposed because of the high risk of procedural failure and complications as well as a high probability of spontaneous healing. Long-term treatment is comparable to that in non-SCAD acute coronary syndromes (ACS) but dual antiplatelet therapy should only be started in case of stenting and should be kept as short as possible in patients with vascular Ehlers-Danlos syndrome. Prognosis seems to be better compared to non-SCAD ACS but there is a reasonable risk of recurrence. In this review, we discuss the current knowledge of SCAD and provide a clinical pathway for the diagnosis, management and work-up of SCAD patients.


Assuntos
Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico , Vasos Coronários/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Doenças Vasculares/congênito , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Doenças Vasculares/diagnóstico
16.
Eur Respir J ; 49(5)2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28495691

RESUMO

Screening for pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc) improves outcomes. The DETECT screening algorithm is recommended in a high-risk SSc subgroup. This study aims to compare prospectively the positive predictive value of screening using the DETECT algorithm and the 2009 European Society of Cardiology/European Respiratory Society (ESC/ERS) guidelines, and to compare their cost-effectiveness in an unselected, day-to-day SSc population. Post hoc, screening according to the 2015 ESC/ERS guidelines using echocardiographic parameters alone ("2015 echo screening") or combined with the DETECT algorithm ("2015 combined screening") in high-risk subjects was analysed.195 consecutive SSc patients included in the Ghent University Hospital SSc cohort were screened using different algorithms.The referral rate for right heart catheterisation was 32% (63 out of 195 patients) (46/4/13/34/40 patients using the DETECT algorithm/2009 guidelines/both/2015 echo screening/2015 combined screening). Right heart catheterisation was performed in 53 patients (84%) (36 (78%)/four (100%)/13 (100%)/28 (82%)/32 (80%) patients recommended by the DETECT algorithm/2009 guidelines/both/2015 echo screening/2015 combined screening). PAH was diagnosed in three patients (incidence 1.5%·year-1, 95% CI 0.5-4.4), in whom all algorithms recommended a right heart catheterisation. The positive predictive value was 6% (95% CI 2-17%; three out of 49 patients) for the DETECT algorithm, 18% (95% CI 6-41%; three out of 17 patients) for the 2009 guidelines, 23% (95% CI 8-50%; three out of 13 patients) for both, 11% (95% CI 4-27%; three out of 28 patients) for the 2015 echo screening and 9% (95% CI 3-24%; three out of 32 patients) for the 2015 combined screening. The cost was EUR224/80/90/112 per patient using the DETECT algorithm/2009 guidelines/2015 echo screening/2015 combined screening.Echocardiography may remain a candidate first step for PAH screening in SSc.


Assuntos
Hipertensão Pulmonar/diagnóstico , Programas de Rastreamento/métodos , Adulto , Algoritmos , Cateterismo Cardíaco , Análise Custo-Benefício , Ecocardiografia , Europa (Continente) , Feminino , Humanos , Hipertensão Pulmonar/complicações , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Escleroderma Sistêmico/complicações
18.
Catheter Cardiovasc Interv ; 86(5): E205-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25754018

RESUMO

OBJECTIVES: The purpose of this study was to quantify the reduction in patient radiation dose during coronary angiography (CA) by a new X-ray technology, and to assess its impact on diagnostic image quality. BACKGROUND: Recently, a novel X-ray imaging technology has become available for interventional cardiology, using advanced image processing and an optimized acquisition chain for radiation dose reduction. METHODS: 70 adult patients were randomly assigned to a reference X-ray system or the novel X-ray system. Patient demographics were registered and exposure parameters were recorded for each radiation event. Clinical image quality was assessed for both patient groups. RESULTS: With the same angiographic technique and a comparable patient population, the new imaging technology was associated with a 75% reduction in total kerma-area product (KAP) value (decrease from 47 Gycm2 to 12 Gycm2, P<0.001). Clinical image quality showed an equivalent detail and contrast for both imaging systems. On the other hand, the subjective appreciation of noise was more apparent in images of the new image processing system, acquired at lower doses, compared to the reference system. However, the higher noise content did not affect the overall image quality score, which was adequate for diagnosis in both systems. CONCLUSIONS: For the first time, we present a new X-ray imaging technology, combining advanced noise reduction algorithms and an optimized acquisition chain, which reduces patient radiation dose in CA drastically (75%), while maintaining diagnostic image quality. Use of this technology may further improve the radiation safety of cardiac angiography and interventions.


Assuntos
Cineangiografia/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Idoso , Algoritmos , Cineangiografia/instrumentação , Angiografia Coronária/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
20.
Catheter Cardiovasc Interv ; 82(4): E419-27, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23420705

RESUMO

OBJECTIVES: The purpose of this study was to assess patient-specific organ doses and cancer risk with 3D-rotational acquisitions versus the current standard of multiple single-plane coronary angiography (CA). BACKGROUND: Catheter-based CA remains one of the most commonly performed diagnostic invasive procedures delivering a relatively high radiation dose to the patient. With the introduction of flat-panel technology, three-dimensional rotational angiography became an alternative for the conventional two-dimensional angiography. However, limited information is available on the difference in patient radiation exposure with both acquisition techniques. METHODS: Eighty adult patients (45 males, age 38-93 years) were randomly assigned to the rotational or standard angiography group. Exposure parameters were registered and skin dose distribution was measured during the procedure. Patient-specific organ doses and related cancer risks were assessed with dedicated software. RESULTS: Rotational angiograms were associated with 33% lower KAP-values (decrease from 49.99 Gycm(2) to 33.37 Gycm(2), P < 0.001). A significant (P < 0.001) lower peak skin dose was measured with rotational acquisitions (80 mGy, median) versus planar imaging (172 mGy, median). Moreover, the skin dose was smoothed over the whole chest of the patient. Contrast medium consumption decreased from 104 mL to 73 mL (P < 0.001) with the use of 3D-imaging. The reduction in radiation exposure resulted in a corresponding decrease of organ doses. The latter contributed to an overall cancer risk reduction of 21% for males and 50% for females. CONCLUSIONS: The current study demonstrates that in CA radiation risk reduction is feasible by using a rotational acquisition technique.


Assuntos
Cineangiografia/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica , Cineangiografia/efeitos adversos , Meios de Contraste , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/prevenção & controle , Segurança do Paciente , Valor Preditivo dos Testes , Monitoramento de Radiação/métodos , Medição de Risco , Fatores de Risco , Pele/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...