1.
Clin Lab ; 70(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38469786

RESUMO

BACKGROUND: Hemoglobin A1C (HbA1C) is used to evaluate glycemic control over a three-month period. Blood matrix-based HbA1C materials are needed for quality control and evaluation of HbA1C measurements. This study investigated the commutability of blood materials (BMs) and aimed to upgrade BMs for HbA1C testing for use as proficiency test (PT) material. METHODS: We measured BMs from a DM blood donor (n = 1), an in vitro glycation procedure (n = 3), and from commercial sources (n = 2) for HbA1C in parallel with fresh unprocessed BMs (n = 3) and clinical blood samples (n = 25). Two NGSP-certified methods, including a turbidimetric and an enzymatic immunoassay, were used for HbA1C determinations. Commutability as investigated according to CLSI EP14-Ed4 guidelines. RESULTS: The commutable BMs exhibited a mean paired difference of 0% to 9% when compared to reference methods, whereas the non-commutable BMs represented a mean paired difference of 3% to 11%. Fresh, unprocessed BMs with a low HbA1C of 6.0% were more commutable than BMs with a high HbA1C. The values of HbA1C in BMs (mean and uncertainty following ISO Guide 35 for RM production) were applied to upgrade the PT material to be used as a reference material. The relative uncertainty of BM-Ndm-1 and BM-Gcb-3 were 1 and 0.4%, respectively. CONCLUSIONS: The commutability of hemoglobin in BMs is dependent on the preparation process. Blood materials with a high HbA1C content are usually less commutable versus materials with low HbA1C content when prepared by the same process. Our study showed BMs can be successfully used as quality control or PT materials.


Assuntos
Testes Hematológicos , Humanos , Padrões de Referência , Hemoglobinas Glicadas , Incerteza , Controle de Qualidade
2.
J Diabetes Sci Technol ; 17(1): 125-132, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34515537

RESUMO

BACKGROUND: Annual peaks in temperature and humidity exceed manufacturers' specifications for blood glucose test strip storage in Thailand. Health Promoting Hospitals (HPH) do not always provide the same level of health services that hospitals do since they often only turn on air-conditioning units during working hours. METHODS: The blood glucose testing performance of 4 glucose meters were investigated for short and long terms stress at 5 simulated conditions. Temperature and relative humidity (RH) at 5 HPHs in different regions of Thailand were monitored for 9 weeks during April to July 2019. The use of air conditioning in storage rooms for storing test strips was surveyed at 131 HPHs using questionnaires. RESULTS: Median-paired differences of glucose measurements with stressed test strips in 5 simulated conditions significantly differed (P < 0.05) both in the short term (3 days) and in the long term (30 days) with 4 glucose meters when compared to unstressed test strips. The average temperature of all HPHs exceeded 30°C (86°F). The average RH was 84%. There was only one HPH that occasionally turned on its air conditioners. Most HPHs kept both opened and unopened vials of test strips in rooms without air conditioners. Further, 21.4-32.0% of HPHs kept test strips at room with air conditioners. CONCLUSIONS: This study provides evidence for poor performance of blood glucose testing by glucose meters that are affected by adverse environmental conditions. The environmental for test strips storage at HPHs should be considered to prevent analytical errors of glucose measurement.


Assuntos
Glicemia , Glucose , Humanos , Fitas Reagentes , Hospitais , Promoção da Saúde