RESUMO
BACKGROUND: The ARDS is characterized by different degrees of impairment in oxygenation and distribution of the lung disease. Two radiological patterns have been described: a focal and a diffuse one. These two patterns could present significant differences both in gas exchange and in the response to a recruitment maneuver. At the present time, it is not known if the focal and the diffuse pattern could be characterized by a difference in the lung and chest wall mechanical characteristics. Our aims were to investigate, at two levels of PEEP, if focal vs. diffuse ARDS patterns could be characterized by different lung CT characteristics, partitioned respiratory mechanics and lung recruitability. METHODS: CT patterns were analyzed by two radiologists and were classified as focal or diffuse. The changes from 5 to 15 cmH2O in blood gas analysis and partitioned respiratory mechanics were analyzed. Lung CT scan was performed at 5 and 45 cmH2O of PEEP to evaluate lung recruitability. RESULTS: One-hundred and ten patients showed a diffuse pattern, while 58 showed a focal pattern. At 5 cmH2O of PEEP, the driving pressure and the elastance, both the respiratory system and of the lung, were significantly higher in the diffuse pattern compared to the focal (14 [11-16] vs 11 [9-15 cmH2O; 28 [23-34] vs 21 [17-27] cmH2O/L; 22 [17-28] vs 14 [12-19] cmH2O/L). By increasing PEEP, the driving pressure and the respiratory system elastance significantly decreased in diffuse pattern, while they increased or did not change in the focal pattern (Δ15-5: - 1 [- 2 to 1] vs 0 [- 1 to 2]; - 1 [- 4 to 2] vs 1 [- 2 to 5]). At 5 cmH2O of PEEP, the diffuse pattern had a lower lung gas (743 [537-984] vs 1222 [918-1974] mL) and higher lung weight (1618 [1388-2001] vs 1222 [1059-1394] g) compared to focal pattern. The lung recruitability was significantly higher in diffuse compared to focal pattern 21% [13-29] vs 11% [6-16]. Considering the median of lung recruitability of the whole population (16.1%), the recruiters were 65% and 22% in the diffuse and focal pattern, respectively. CONCLUSIONS: An early identification of lung morphology can be useful to choose the ventilatory setting. A diffuse pattern has a better response to the increase of PEEP and to the recruitment maneuver.
RESUMO
PURPOSE: To determine the accuracy of MDCT in the evaluation of blunt surgically relevant bowel and/or mesenteric injuries (BMIs) using single specific CT signs together with specific pairs of nonspecific signs. METHODS: Fifty-four patients examined with MDCT were divided into two groups: a 'surgical' group of 20 patients-which underwent surgery for blunt BMIs-and a control group of 34 'nonsurgical' trauma patients. Two radiologists with different experience performed a double-blind retrospective evaluation of the images, classifying the patients in the two groups by using only single specific signs; then, the images were reviewed in consensus with a third radiologist and sensitivity and specificity were calculated. Subsequently, the frequency of every single sign and of every possible combination of nonspecific signs in the two groups was registered, to find combinations present only in the surgical group; sensitivity and specificity were calculated by using even those specific combinations. RESULTS: At the first consensual evaluation, sensitivity and specificity were 75 and 100%, respectively. Two combinations of nonspecific signs (focal wall thickening + extraluminal air; focal wall thickening + seat belt sign) were found only in surgical patients that did not present any single specific sign: Sensitivity calculated adding those two combinations was 95%, without a decrease in specificity. CONCLUSIONS: MDCT is an accurate technique in the evaluation of blunt surgically relevant BMIs. The single specific CT signs were sufficient for the diagnosis in only 75% of the cases; adding the two specific combinations allowed an increase in sensitivity of 20%.
Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Intestinos/lesões , Mesentério/lesões , Tomografia Computadorizada Multidetectores/métodos , Ferimentos não Penetrantes/diagnóstico por imagem , Traumatismos Abdominais/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Método Duplo-Cego , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Ferimentos não Penetrantes/cirurgiaRESUMO
PURPOSE: To evaluate whether the addition of gadolinium-enhanced MRI and diffusion-weighted imaging (DWI) improves T2 sequence performance for the diagnosis of local recurrence (LR) from rectal cancer and to assess which approach is better at formulating this diagnosis among readers with different experience. METHODS: Forty-three patients with suspected LR underwent pelvic MRI with T2 weighted (T2) sequences, gadolinium fat-suppressed T1 weighted sequences (post-contrast T1), and DWI sequences. Three readers (expert: G, intermediate: E, resident: V) scored the likelihood of LR on T2, T2 + post-contrast T1, T2 + DWI, and T2 + post-contrast T1 + DWI. RESULTS: In total, 18/43 patients had LR; on T2 images, the expert reader achieved an area under the ROC curve (AUC) of 0.916, sensitivity of 88.9%, and specificity of 76%; the intermediate reader achieved values of 0.890, 88.9%, and 48%, respectively, and the resident achieved values of 0.852, 88.9%, and 48%, respectively. DWI significantly improved the AUC value for the expert radiologist by up to 0.999 (p = 0.04), while post-contrast T1 significantly improved the AUC for the resident by up to 0.950 (p = 0.04). For the intermediate reader, both the T2 + DWI AUC and T2 + post-contrast T1 AUC were better than the T2 AUC (0.976 and 0.980, respectively), but with no statistically significant difference. No statistically significant difference was achieved by any of the three readers by comparing either the T2 + DWI AUCs to the T2 + post-contrast T1 AUCs or the AUCs of the two pairs of sequences to those of the combined three sequences. Furthermore, using the T2 sequences alone, all of the readers achieved a fair number of "equivocal" cases: they decreased with the addition of either DWI or post-contrast T1 sequences and, for the two less experienced readers, they decreased even more with the three combined sequences. CONCLUSIONS: Both DWI and T1 post-contrast MRI increased diagnostic performance for LR diagnosis compared to T2; however, no significant difference was observed by comparing the two different pairs of sequences with the three combined sequences.
Assuntos
Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Retais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Variações Dependentes do Observador , Compostos Organometálicos , Neoplasias Retais/patologia , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: High blood flow and low recirculation rates are central for adequate haemodialysis. A new symmetrical tip has been invented promising efficient haemodialysis even if the ports are reversed. OBJECTIVE: To evaluate access recirculation of the 'palindrome' catheter and to report initial experiences in a clinical setting. MATERIAL AND METHODS: After implantation of the new catheter in 20 patients (male: 14; female: 6; mean age 72 ± 12.2), access recirculation was evaluated using the urea-based recirculation test. After 30 minutes of haemodialysis, ultrafiltration was stopped and arterial and venous samples were taken. Afterwards, the blood flow rate was reduced to 120 ml/min. Another systemic arterial blood sample was taken 10 seconds after the blood pump was switched off. RESULTS: All 20 interventions were performed successfully without complications. The average recirculation rate was 8.1% with a median of 2.5% ranging from 0 to 85.8%. Recirculation rates under 5% were measured in 13 patients and more than 10% recirculation were found in two patients. The median of days between catheter implantation and recirculation assessment was the day following implantation. CONCLUSION: The new symmetrical catheter presented low recirculation rates in a clinical setting. Since there is just a single tip, fluoroscopic placement in the right atrium is facilitated.
Assuntos
Cateteres Venosos Centrais/normas , Diálise Renal/métodos , Ureia/análise , Idoso , Idoso de 80 Anos ou mais , Cateteres Venosos Centrais/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diálise Renal/normas , Insuficiência Renal Crônica/terapia , Reprodutibilidade dos Testes , Ureia/sangueRESUMO
The aim of this study was to evaluate intermediate-term results after microwave ablation (MWA) of renal tumours and determine the association of RENAL and modified RENAL (mRENAL) scores with oncological outcomes and complications. In May 2008-September 2014, 58 patients affected by early-stage RCC (renal cell carcinoma; T1a or T1b) were judged unsuitable for surgery and treated with percutaneous MWA. Follow-up was performed with contrast-enhanced computed tomography at 1, 3, 6, 12 and 24 months after the procedure. Technical success (TS), primary technical effectiveness (PTE), secondary technical effectiveness (STE), the local tumour progression rate (LTPR), the cancer-specific survival rate (CSSR), disease-free survival (DFS), overall survival (OS) and safety were recorded. All lesions were evaluated using RENAL and mRENAL scores, and complications were assessed with RENAL scores. The TS rate was 100%, PTE was 93%, STE was 100%, LTPR was 15.7% at 1 year, CSSR was 96.5%, DFS was 87.9% at 5 years, and OS was 80.6%. Mean follow-up was 25.7 months (range 3-72). The mean ± standard deviation (SD) RENAL and mRENAL scores of all treated tumours were 6.7 ± 2.05 (range 4-11) and 7 ± 2.3 (range 4-12), respectively. Major complications occurred in two (2/58) and minor complications in three patients (3/58). Overall complications correlated significantly with RENAL scores; in particular, E and L represent negative predictors for safety and effectiveness. MWA is a valuable alternative for treating RCCs. The correlation with outcomes and complications of RENAL and mRENAL scores could help to customise MWA indications in RCC patients.
Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/patologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do TratamentoRESUMO
PURPOSE: The aim of our study was to evaluate factors influencing effectiveness of percutaneous microwave ablation (MWA) in patients with small hepatocellular carcinoma (HCC) (<3 cm). MATERIALS AND METHODS: Between December 2007 and August 2015, 49 patients with 65 previously histological typed HCC were treated in a total of 61 sessions. Tumours were subdivided into central (>3 cm from the capsule) (n = 22) and peripheral (<3 cm from the capsule) (n = 43). Imaging follow-up was performed at 1, 3, 6, and 12 months after treatment, then annually. Mean follow-up period was 18 months (range 1-55). Location of the lesion, age, sex, and underlying disease of the patients was analyzed and related with efficacy. RESULTS: Technical success was obtained in all cases. Residual disease was registered in 21 lesions (32.3 %): 13 were peripheral and 8 were central. Twelve of them were retreated with percutaneous MWA. Local recurrence was recorded in 8 lesions (12.3 %): 5 were retreated with MWA. No significant difference in terms of effectiveness was observed in lesions located in a central position and those situated in the peripheral position. Age, sex, and underlying disease not influenced results. Only one major complication was observed. The rate of minor complications was 24.5 %. Mortality at 30 days was 0 %. CONCLUSIONS: Our results encourage the role of MWA in the treatment of small HCC. More numerous series and randomized studies are necessary to state the role of MWA and to select cases in which MWA may be more effective and safer than RFA.
Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/métodos , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Interventional radiological procedures for diagnosis and treatment of lung cancer have become increasingly important. Imaging-guided percutaneous biopsy has become the modality of choice for diagnosing lung cancer, and in the era of target therapies, it is an useful tool to define earlier patient-specific tumor phenotypes. In functionally inoperable patients, especially the ablative procedures are potentially curative alternatives to surgery. In addition to thermally ablative treatment, selective chemoembolization by a vascular access allows localized therapy. These treatments are considered for patients in a reduced general condition which does not allow systemic chemotherapy. The present article reviews the role of interventional oncology in the management of primary lung cancer, focusing on the state of the art for each procedure.
Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Oncologia/métodos , Biópsia , Embolização Terapêutica/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Radiologia Intervencionista/métodosRESUMO
AIM: To evaluate the technical and clinical success, primary patency (PP) and complications of angioplasty performed with paclitaxel-coated balloon (PCBs) associated with cutting balloon and for the treatment of the outflow stenoses of failing hemodialysis arteriovenous shunt. MATERIAL AND METHODS: From September 2014 to September 2015, 50 patients with 66 stenoses were registered. Vascular accesses were autogenous (n = 20) and prosthetic (n = 30). Stenosis were documented during follow-up with routine echo-color Doppler, clinical evaluation and in the remaining incidentally during fistulography. Angioplasty was performed with cutting balloon and afterward with PCB. The mean follow-up time was 8 months (range 6-15 months). Technical success, clinical success, primary patency and complications were registered. RESULTS: Technical success was 100 %. Clinical success was 94.7 %. Primary patency rate was 87.7 %; in five patients, a significant re-stenosis (≥50 %) was registered. A residual asymptomatic stenosis (<30 %) was registered in four cases (7 %). No major complications were registered. CONCLUSIONS: A short-term patency benefit may be obtained including PCB in angioplasty treatment of failing hemodialysis arteriovenous shunts.
Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Paclitaxel/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Diálise Renal , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
Percutaneous radiofrequency ablation (RFA) can be as effective as surgical resection in terms of overall survival and recurrence-free survival rates in patients with small hepatocellular carcinoma (HCC). Effectiveness of RFA is adversely influenced by heat-sink effect. Other ablative therapies could be considered for larger tumors or for tumors located near the vessels. In this regard, recent improvements in microwave energy delivery systems seem to open interesting perspectives to percutaneous ablation, which could become the ablation technique of choice in the near future. Microwave ablation (MWA) has the advantages of possessing a higher thermal efficiency. It has high efficacy in coagulating blood vessels and is a relatively fast procedure. The time required for ablation is short and the shape of necrosis is elliptical with the older systems and spherical with the new one. There is no heat-sink effect and it can be used to ablate tumors adjacent to major vessels. These factors yield a large ablation volume, and result in good local control and fewer complications. This review highlights the most relevant updates on MWA in the treatment of small (<3 cm) HCC. Furthermore, we discuss the possibility of MWA as the first ablative choice, at least in selected cases.
RESUMO
This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.
Assuntos
Anestésicos/administração & dosagem , Doenças Musculoesqueléticas/terapia , Plasma Rico em Plaquetas , Esteroides/administração & dosagem , Ultrassonografia de Intervenção/métodos , Anestésicos/efeitos adversos , Anestésicos/farmacologia , Terapias Complementares/métodos , Esquema de Medicação , Humanos , Ácido Hialurônico/administração & dosagem , Ácido Hialurônico/efeitos adversos , Ácido Hialurônico/farmacologia , Injeções , Oxigênio/administração & dosagem , Oxigênio/efeitos adversos , Ozônio/administração & dosagem , Ozônio/efeitos adversos , Seleção de Pacientes , Esteroides/efeitos adversos , Esteroides/farmacologiaRESUMO
Lower gastrointestinal bleeding (LGIB) is associated with high morbidity and mortality. Embolization is currently proposed as the first step in the treatment of acute, life-threatening LGIB, when endoscopic approach is not possible or is unsuccessful. Like most procedures performed in emergency setting, time represents a significant factor influencing outcome. Modern tools permit identifying and reaching the bleeding site faster than two-dimensional angiography. Non-selective cone-beam CT arteriography can identify a damaged vessel. Moreover, sophisticated software able to detect the vessel may facilitate direct placement of a microcatheter into the culprit vessel without the need for sequential angiography. A further important aspect is the use of an appropriate technique of embolization and a safe and effective embolic agent. Current evidence shows the use of detachable coils (with or without a triaxial system) and liquid embolics has proven advantages compared with other embolic agents. The present article analyses these modern tools, making embolization of acute LGIB safer and more effective.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Serviço Hospitalar de Emergência , Trato Gastrointestinal/diagnóstico por imagem , HumanosRESUMO
The management of trauma patients has evolved in recent decades owing to increasing availability of advanced imaging modalities such as CT. Nowadays, CT has replaced the diagnostic function of angiography. The latter is considered when a therapeutic option is hypothesized. Arterial embolization is a life-saving procedure in abdominopelvic haemorrhagic patients, reducing relevant mortality rates and ensuring haemodynamic stabilization of the patient. Percutaneous transarterial embolization has been shown to be effective for controlling ongoing bleeding for patients with high-grade abdominopelvic injuries, thereby reducing the failure rate of non-operative management, preserving maximal organ function. Surgery is not always the optimal solution for stabilization of a patient with polytrauma. Mini-invasivity and repeatability may be considered as relevant advantages. We review technical considerations, efficacy and complication rates of hepatic, splenic, renal and pelvic embolization to extrapolate current evidence about transarterial embolization in traumatic patients.
Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Embolização Terapêutica , Pelve/diagnóstico por imagem , Pelve/lesões , Radiologia Intervencionista , Tomografia Computadorizada por Raios X , Traumatismos Abdominais/terapia , Hemorragia/diagnóstico por imagem , Hemorragia/terapia , Humanos , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/terapiaRESUMO
BACKGROUND: This study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings. METHODS: Twenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered. RESULTS: The bleeding site was not detected by initial angiogram in 20% of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95%) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90%) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95%. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min. CONCLUSIONS: C-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.
Assuntos
Artérias/diagnóstico por imagem , Embolização Terapêutica/métodos , Hemorragia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SoftwareRESUMO
BACKGROUND: Recently different software with the ability to plan ablation volumes have been developed in order to minimize the number of attempts of positioning electrodes and to improve a safe overall tumor coverage. PURPOSE: To assess the feasibility of three-dimensional cone beam computed tomography (3D CBCT) fusion imaging with "virtual probe" positioning, to predict ablation volume in lung tumors treated percutaneously. MATERIAL AND METHODS: Pre-procedural computed tomography contrast-enhanced scans (CECT) were merged with a CBCT volume obtained to plan the ablation. An offline tumor segmentation was performed to determine the number of antennae and their positioning within the tumor. The volume of ablation obtained, evaluated on CECT performed after 1 month, was compared with the pre-procedural predicted one. Feasibility was assessed on the basis of accuracy evaluation (visual evaluation [VE] and quantitative evaluation [QE]), technical success (TS), and technical effectiveness (TE). RESULTS: Seven of the patients with lung tumor treated by percutaneous thermal ablation were selected and treated on the basis of the 3D CBCT fusion imaging. In all cases the volume of ablation predicted was in accordance with that obtained. The difference in volume between predicted ablation volumes and obtained ones on CECT at 1 month was 1.8 cm(3) (SD ± 2, min. 0.4, max. 0.9) for MW and 0.9 cm(3) (SD ± 1.1, min. 0.1, max. 0.7) for RF. CONCLUSION: Use of pre-procedural 3D CBCT fusion imaging could be useful to define expected ablation volumes. However, more patients are needed to ensure stronger evidence.
Assuntos
Ablação por Cateter , Tomografia Computadorizada de Feixe Cônico , Neoplasias Pulmonares/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Resultado do TratamentoRESUMO
AIM: To evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease. MATERIALS AND METHODS: Between September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated. RESULTS: Image co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02-63.75 Gycm2). The mean total procedure time was 32.2 min (range 27-38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20-40 mL). CONCLUSIONS: IF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.
Assuntos
Arteriopatias Oclusivas/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Procedimentos Endovasculares/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/patologia , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/métodos , Radiologia Intervencionista/métodos , StentsRESUMO
The aim of this study was to assess the feasibility of the application of the new system (Emprint Microwave Ablation System, Covidien Boulder, CO, USA) and to identify its advantages. In particular the attention was focused to the spherical ablation zone obtained and its usefulness in terms of effectiveness. The new system is composed of: a 2450 MHz generator that delivers a maximum power of 100 W, a fiberglass antenna and a pump for internally cooled antenna. Ten liver nodules (8 hepatocellular carcinomas and 2 metastasis) were percutaneously treated (mean diameter 24.9 mm, range 16-35 mm). Technical success, ablation duration time, overall procedure time and safety were registered. To define the shape of the ablation zone, multiplanar reformatting (MPR) was performed. Roundness index transverse was calculated: a value near 1 represents a more spherical ablation zone shape, and a value distant from 1 implies an oval configuration. Technical success was 100%. Mean ablation time was of 3.85 min (range 3-5 min), mean overall procedure time was 30.5 min (range 25-40 min). No major complications were recorded. Roundness index transverse presented a mean value of 0.94, meaning that a spherical shape of ablation zone was achieved. One of the most promising innovations of the new microwave technology is the spherical shape of the ablation volume that could be related with an improving of the effectiveness and safety.
Assuntos
Técnicas de Ablação/instrumentação , Carcinoma Hepatocelular/cirurgia , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/secundário , Desenho de Equipamento , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
INTRODUCTION: We report on the successful endovascular treatment of a ruptured splenic artery pseudoaneurysm. Our patient had acute pancreatitis superimposed on chronic calcific pancreatitis and chronic renal impairment. Contrast-enhanced ultrasonography was used to assess post-embolization results. CASE PRESENTATION: Our patient was a 67-year-old white Caucasian man with recurrent pancreatitis. Computed tomography angiography showed a pancreatic pseudocyst with a ruptured pseudoaneurysm, which was successfully embolized using an endovascular percutaneous approach. At six months, persistent renal failure led to contrast-enhanced ultrasonography. This confirmed the absence of turbulent blood flow and extravasation of contrast medium in the pseudocyst. CONCLUSION: Our experience with this case leads us to support the role of interventional radiology as a first-line treatment tool. Contrast-enhanced ultrasonography can be used to follow-up embolization procedures in patients with impaired renal function.
Assuntos
Falso Aneurisma/diagnóstico por imagem , Aneurisma Roto/diagnóstico por imagem , Embolização Terapêutica/métodos , Pancreatite Crônica/diagnóstico , Ruptura Esplênica/diagnóstico por imagem , Idoso , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Aneurisma Roto/terapia , Angiografia , Humanos , Ligadura , Masculino , Pancreatite/complicações , Pancreatite Crônica/fisiopatologia , Pancreatite Crônica/terapia , Radiologia Intervencionista , Ruptura Esplênica/complicações , Ruptura Esplênica/terapia , Resultado do Tratamento , Ultrassonografia Doppler em CoresRESUMO
BACKGROUND: Computed tomography angiography (CTA) is the most employed modality in the follow-up after endovascular aneurysm repair (EVAR) of abdominal aorta (AA); repeated standard controls expose patients to a high cumulative radiation dose (RD). PURPOSE: To compare image quality and RD between 100 kV and 120 kV protocols in the same group of patients, previously treated with EVAR. MATERIAL AND METHODS: Thirty patients, who had performed a previous CTA at 120 kV, underwent a low dose CTA with the same 64-detector machine. Images were evaluated qualitatively and quantitatively. The influence of body mass index (BMI), considering three groups of patients (normal weight, overweight, and obese) was also assessed. RD values (volume CT dose index and effective dose) were calculated. RESULTS: The mean qualitative score at 100 kV was worse than that at 120 kV, but the difference was not statistically significant and in all cases the image quality was satisfactory. At 100 kV the vessels mean attenuation value was significantly higher; signal-to-noise ratio significantly lower; contrast-to-noise ratio lower, but the difference was not significant. Regarding BMI, the difference in the qualitative score was significant in the obese group, but not in the other two groups; of the quantitative parameters only the signal-to-noise ratio presented a significant difference in the obese group. The average CTDIvol was reduced by 22% and the mean effective dose by 36% with the 100 kV protocol compared to the 120 kV protocol. Both differences were significant. CONCLUSION: The 100 kV protocol allowed a consistent RD reduction, maintaining a satisfactory image quality in all patients.
Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Doses de Radiação , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Meios de Contraste , Feminino , Seguimentos , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
CONTEXT: There is little reported experience of irreversible electroporation (IRE) of locally advanced pancreatic tumors (LAP). In literature, few data reported complications. In particular vascular vasoconstriction miming splenic infarcts in humans has never been found. CASE REPORT: This report describes the onset of asymptomatic multiple little splenic perfusion defects after the treatment of a LAP localized in the boby-tail portion of the pancreas with the application of five percutaneous probes for IRE, in a 79 year-old man. Splenic artery was regularly patent but entirely trapped in the tumor. CONCLUSION: To the best of our knowledge, until now, no experience concerning percutaneous IRE of pancreatic cancer described that phenomenon. The cause could not be established with certainty and "vascular lock" may be a valid hypothesis. Additional studies are necessary to evaluate its frequency and its exact pathophysiological cause in humans.
RESUMO
Image-guided thyroid nodule ablation is a relatively new technique for the management of thyroid disease. Notably, if there has been the correct patient selection and if they are performed in high volume centers and via a standardized technique, image-guided thyroid nodule ablation seems to be safe and effective and it can be used to treat thyroid goiters. However, there is still paucity of level 1 evidences and recommendation comparing ablation to surgical or to other non-surgical treatment modalities. Herein, some technical notes for the thyroid nodule ablation to achieve the critical view of safety are presented. Moreover, an additional remark and appraisal from a surgical point of view is described.