Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 13(4): 265-276, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33543661

RESUMO

Aim: We aimed to develop an easy, low-cost and versatile mass spectrometric method for the bioanalysis of a therapeutic monoclonal antibody (mAb) in human serum that employs peptide adsorption-controlled (PAC)-LC/MS using selected reaction monitoring mode (LC-MS/MS-SRM). Materials & methods: Rituximab was used as a model mAb. To apply the method to human serum samples, a peptide of the complementarity-determining region was selected as the surrogate peptide. The usefulness of PAC-LC-MS/MS-SRM was evaluated by a collaborative study. Results: The calibration curve ranged from 0.5 (or 1.0) to 1000.0 µg/ml. The selectivity, linearity, accuracy and precision met the predefined acceptance criteria. Conclusion: Our method could be a useful bioanalytical method for the quantification of mAbs in clinical samples.


Assuntos
Anticorpos Monoclonais/sangue , Bioensaio/métodos , Cromatografia Líquida/métodos , Peptídeos/metabolismo , Espectrometria de Massas em Tandem/métodos , Humanos
2.
Bioanalysis ; 12(24): 1739-1756, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33242248

RESUMO

Background: Ion-pairing reverse-phase LC coupled with high-resolution mass spectrometry (IP-LC/HRMS) has gained attention in oligonucleotide therapeutic bioanalyses owing to its high sensitivity and selectivity. However, optimization and validation of IP-LC/HRMS-based methods are rare. The objective of this study is the development of a sensitive and reproducible IP-LC/HRMS-based bioanalytical method using clinically approved mipomersen as a model for antisense oligonucleotides. Materials & methods/results: Mipomersen was extracted from rat plasma using Clarity OTX SPE and quantified by IP-LC/HRMS. The calibration range was 0.5-250.0 ng/ml. The developed method met the general regulatory criteria for accuracy, precision, carry-over, selectivity, matrix effect and dilution integrity. Conclusion: A highly sensitive and reliable method for mipomersen measurement with potential antisense oligonucleotide bioanalysis applications has been developed.


Assuntos
Terapia Biológica/métodos , Cromatografia Líquida/métodos , DNA Antissenso/metabolismo , Espectrometria de Massas/métodos , Oligonucleotídeos/metabolismo , Calibragem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...