Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Nucl Cardiol ; 21(1): 96-108, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24185581

RESUMO

BACKGROUND: Accurate alignment between cardiac CT angiographic studies (CTA) and nuclear perfusion images is crucial for improved diagnosis of coronary artery disease. This study evaluated in an animal model the accuracy of a CTA fully automated biventricular segmentation algorithm, a necessary step for automatic and thus efficient PET/CT alignment. METHODS AND RESULTS: Twelve pigs with acute infarcts were imaged using Rb-82 PET and 64-slice CTA. Post-mortem myocardium mass measurements were obtained. Endocardial and epicardial myocardial boundaries were manually and automatically detected on the CTA and both segmentations used to perform PET/CT alignment. To assess the segmentation performance, image-based myocardial masses were compared to experimental data; the hand-traced profiles were used as a reference standard to assess the global and slice-by-slice robustness of the automated algorithm in extracting myocardium, LV, and RV. Mean distances between the automated and the manual 3D segmented surfaces were computed. Finally, differences in rotations and translations between the manual and automatic surfaces were estimated post-PET/CT alignment. The largest, smallest, and median distances between interactive and automatic surfaces averaged 1.2 ± 2.1, 0.2 ± 1.6, and 0.7 ± 1.9 mm. The average angular and translational differences in CT/PET alignments were 0.4°, -0.6°, and -2.3° about x, y, and z axes, and 1.8, -2.1, and 2.0 mm in x, y, and z directions. CONCLUSIONS: Our automatic myocardial boundary detection algorithm creates surfaces from CTA that are similar in accuracy and provide similar alignments with PET as those obtained from interactive tracing. Specific difficulties in a reliable segmentation of the apex and base regions will require further improvements in the automated technique.


Assuntos
Angiografia Coronária/métodos , Processamento Eletrônico de Dados , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Miocárdio/patologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Perfusão , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio/química , Suínos
2.
J Am Coll Cardiol ; 62(11): 970-8, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-23810885

RESUMO

OBJECTIVES: The aim of this study was to determine whether post-traumatic stress disorder (PTSD) is associated with coronary heart disease (CHD) using a prospective twin study design and objective measures of CHD. BACKGROUND: It has long been hypothesized that PTSD increases the risk of CHD, but empirical evidence using objective measures is limited. METHODS: We conducted a prospective study of middle-aged male twins from the Vietnam Era Twin Registry. Among twin pairs without self-reported CHD at baseline, we selected pairs discordant for a lifetime history of PTSD, pairs discordant for a lifetime history of major depression, and pairs without either condition. All underwent a clinic visit after a median follow-up of 13 years. Outcomes included clinical events (myocardial infarction, other hospitalizations for CHD and coronary revascularization) and quantitative measures of myocardial perfusion by [(13)N] ammonia positron emission tomography, including a stress total severity score and coronary flow reserve. RESULTS: A total of 562 twins (281 pairs) with a mean age of 42.6 years at baseline were included in this study. The incidence of CHD was more than double in twins with PTSD (22.6%) than in those without PTSD (8.9%; p < 0.001). The association remained robust after adjusting for lifestyle factors, other risk factors for CHD, and major depression (odds ratio: 2.2; 95% confidence interval: 1.2 to 4.1). Stress total severity score was significantly higher (+95%, p = 0.001) and coronary flow reserve was lower (-0.21, p = 0.02) in twins with PTSD than in those without PTSD, denoting worse myocardial perfusion. Associations were only mildly attenuated in 117 twin pairs discordant for PTSD. CONCLUSIONS: Among Vietnam-era veterans, PTSD is a risk factor for CHD.


Assuntos
Doença da Artéria Coronariana/epidemiologia , Doenças em Gêmeos , Transtornos de Estresse Pós-Traumáticos/complicações , Gêmeos/estatística & dados numéricos , Veteranos/estatística & dados numéricos , Adulto , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Seguimentos , Inquéritos Epidemiológicos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Gêmeos Dizigóticos , Gêmeos Monozigóticos , Estados Unidos/epidemiologia , Guerra do Vietnã
3.
Nucl Med Commun ; 34(2): 124-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23211996

RESUMO

OBJECTIVE: Left ventricular (LV) function and dyssynchrony parameters measured from serial gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) using blinded processing had a poorer repeatability than when manual side-by-side processing was used. The objective of this study was to validate whether an automatic alignment tool can reduce the variability of LV function and dyssynchrony parameters in serial gated SPECT MPI. METHODS: Thirty patients who had undergone serial gated SPECT MPI were prospectively enrolled in this study. Thirty minutes after the first acquisition, each patient was repositioned and a gated SPECT MPI image was reacquired. The two data sets were first processed blinded from each other by the same technologist in different weeks. These processed data were then realigned by the automatic tool, and manual side-by-side processing was carried out. All processing methods used standard iterative reconstruction and Butterworth filtering. The Emory Cardiac Toolbox was used to measure the LV function and dyssynchrony parameters. RESULTS: The automatic tool failed in one patient, who had a large, severe scar in the inferobasal wall. In the remaining 29 patients, the repeatability of the LV function and dyssynchrony parameters after automatic alignment was significantly improved from blinded processing and was comparable to manual side-by-side processing. CONCLUSION: The automatic alignment tool can be an alternative method to manual side-by-side processing to improve the repeatability of LV function and dyssynchrony measurements by serial gated SPECT MPI.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo
4.
J Nucl Cardiol ; 19(3): 500-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22203443

RESUMO

BACKGROUND: Phase analysis has been developed and validated to measure left-ventricular dyssynchrony from gated SPECT myocardial perfusion imaging. The purpose of this study is to evaluate its performance in regions with perfusion defects. METHODS: A special version of the eXtended CArdiac Torso digital phantom was developed to track B-spline points in each temporal frame. A region of 35 B-spline points in the inferior wall with normal and abnormal perfusion uptakes were simulated. Phase shifts were simulated in the same region, representing dyssynchronous contraction. Gated SPECT data were analyzed using a modified phase analysis algorithm, which tracked the same 35 B-spline points to calculate their phases. RESULTS: Phases and phase shifts measured in the B-spline points with perfusion uptake in the range of 50%-10% did not significantly differ from those measured in the same B-spline points with normal perfusion uptake. CONCLUSION: Phase analysis can accurately measure phases in regions with abnormal perfusion uptake as low as 10% of the perfusion uptake in the normal regions, which corresponded to a regional signal-to-noise ratio (SNR) of 12.0 or greater. In 42 consecutive patients with myocardial infarction >20% of the left ventricle, only two patients had a SNR within the perfusion defects below that threshold.


Assuntos
Algoritmos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Humanos , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Disfunção Ventricular Esquerda/etiologia
7.
J Nucl Med ; 52(2): 210-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21233190

RESUMO

Myocardial perfusion imaging (MPI) using nuclear cardiology techniques has been widely applied in clinical practice because of its well-documented value in the diagnosis and prognosis of coronary artery disease. Industry has developed innovative designs for dedicated cardiac SPECT cameras that constrain the entire detector area to imaging just the heart. New software that recovers image resolution and limits image noise has also been implemented. These SPECT innovations are resulting in shortened study times or reduced radiation doses to patients, promoting easier scheduling, higher patient satisfaction, and, importantly, higher image quality. This article describes these cardiocentric SPECT software and hardware innovations, which provide a strong foundation for the continued success of myocardial perfusion SPECT.


Assuntos
Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/tendências , Imagem de Perfusão do Miocárdio , Reprodutibilidade dos Testes , Software , Tomografia Computadorizada de Emissão de Fóton Único/tendências
8.
Int J Cardiovasc Imaging ; 27(7): 1095-104, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21110103

RESUMO

Left ventricular (LV) wall thickening (WT) assessed from myocardial perfusion (MP) gated SPECT data has been reported to be a marker of functional recovery following myocardial damage. However, the accuracy of WT measurements obtained in the clinical setting rarely has been validated against an independent quantitative reference standard. The purpose of this investigation was to assess the degree to which quantified MP WT agrees with cardiac magnetic resonance (CMR) WT measurements, and to determine whether quantitation is as accurate as visual analysis in detecting abnormal regional WT. MP and ECG-gated True-FISP CMR data were analyzed for 20 patients evaluated after myocardial infarction (age 60 ± 11 years; 95% males). An experienced observer visually graded MP WT on a 5-point scale while viewing MP cines. MP WT was quantified using "Emory Cardiac Toolbox" (ECTb) algorithms. MP algorithms isolated myocardial counts and generated polar maps of WT. CMR data were analyzed by Medis "MASS" software. Manually drawn endocardial and epicardial contours were used to compute WT on CMR. CMR data also were processed for 10 age-matched normal volunteers to define the CMR WT threshold of abnormality. All computations were sampled into conventional 17 ACC/AHA LV wall segments. Receiver operating characteristics (ROC) curve analysis provided discrimination thresholds for optimal accuracy, which subsequently were used to dichotomize the MP methods. WT abnormalities also were assessed for the 3 major arterial territories, and for total numbers of abnormal segments per patient. 25% of all segments had abnormally low WT by CMR. While MP quantitation underestimated CMR WT values for segments with normal WT (26 ± 13% vs. 56 ± 28%, P < 0.0001), measurements were similar for segments with abnormal WT (4 ± 12% vs. 5 ± 9%, P = 0.45). On a segment-by-segment basis, detection of abnormal WT was more accurate by quantitative than visual analysis both for continuous variables (ROC area = 88 ± 2% vs. 80 ± 3%, P < 0.0001) and for dichotomized methods (83% vs. 76%, P = 0.04). Agreement of MP versus CMR for discriminating segments with normal from abnormal WT was significantly better for quantitative than visual analysis (κ = 0.59 vs. 0.40, P < 0.0001), with strongest agreement for left anterior descending artery territories (κ = 0.72). Total numbers of segments with abnormal WT per patient demonstrated significant correlation with CMR (r = 0.83, P < 0.0001). MP quantified LV ejection fractions and volumes also correlated well with CMR (r = 0.87 and 0.90, respectively). Quantified MP WT measurements correlated significantly with CMR values, and discriminated segments with abnormal WT from segments with normal WT more accurately than visual analysis. Therefore, quantification should be performed when analyzing regional WT by scintigraphy.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Idoso , Algoritmos , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Circulação Coronária , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Volume Sistólico , Função Ventricular Esquerda
9.
IEEE Trans Nucl Sci ; 58(5): 2296-2302, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24825924

RESUMO

Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken to compare the automatic alignment to interactive alignment by two experts.

10.
IEEE Nucl Sci Symp Conf Rec (1997) ; 2010: 2996-2997, 2010 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-21892259

RESUMO

Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTCA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register and display the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken using interactive alignment by experts.

12.
Cardiol Clin ; 27(2): 227-36, Table of Contents, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19306766

RESUMO

This article describes advancements in hardware and software for myocardial perfusion imaging that are becoming commercialized today and their implication in clinical practice.


Assuntos
Câmaras gama/tendências , Cardiopatias/diagnóstico por imagem , Design de Software , Software/tendências , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/tendências
14.
J Nucl Cardiol ; 16(2): 201-11, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19156478

RESUMO

BACKGROUND: We evaluated the incremental diagnostic value of fusion images of coronary computed tomography angiography (CTA) and myocardial perfusion imaging (MPI) over MPI alone or MPI and CTA side-by-side to identify obstructive coronary artery disease (CAD > 50% stenosis) using invasive coronary angiography (ICA) as the gold standard. METHODS: 50 subjects (36 men; 56 +/- 11 years old) underwent rest-stress MPI and CTA within 12-26 days of each other. CTAs were performed with multi-detector CT-scanners (31 on 64-slice; and 19 on 16-slice). 37 patients underwent ICA while 13 subjects did not because of low (<5%) pre-test likelihood (LLK) of disease. Three blinded readers scored the images in sequential sessions using (1) MPI alone (2) MPI and CTA side-by-side, (3) fused CTA/MPI images. RESULTS: One or more critical stenoses during ICA were found in 28 patients and non-critical stenoses were found in 9 patients. MPI, side-by-side MPI-CTA, and fused CTA/MPI showed the same normalcy rate (NR:13/13) in LLK subjects. The fusion technique performed better than MPI and MPI and CTA side-by-side for the presence of CAD in any vessel (overall area under the curve (AUC) for fused images: 0.89; P = .005 vs MPI, P = .04 vs side-by-side MPI-CTA) and for localization of CAD to the left anterior descending coronary artery (AUC: 0.82, P < .001 vs MPI; P = .007 vs side-by-side MPI-CTA). There was a non-significant trend for better detection of multi-vessel disease with fusion. CONCLUSIONS: Using ICA as the gold standard, fusion imaging provided incremental diagnostic information compared to MPI alone or side-by-side MPI-CTA for the diagnosis of obstructive CAD and for localization of CAD to the left anterior descending coronary artery.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Técnica de Subtração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
15.
Nucl Med Commun ; 29(11): 970-81, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18836375

RESUMO

OBJECTIVES: This study was performed to determine the prognostic performance of quantitative PET tools in the stratification of patients with ischemic cardiomyopathy undergoing myocardial viability assessment. METHODS: We applied four different quantitative tools to 104 consecutive patients with coronary artery disease and previous myocardial infarction who had undergone rest Rb/gated F-fluorodeoxyglucose (FDG) PET, to assess myocardial viability for potential revascularization. One of these tools was based on the FDG study alone and the other three tools assessed the extent of match/mismatch defects using FDG in comparison with a perfusion reference database. The four quantitative tools used in this research to define viability were (i) FDG alone, which calculates the percentage of left ventricular myocardium (LVM) that is above the 50% of the maximum LVM FDG counts, (ii) low flow match/mismatch, which determines the area with a 5% increase in normalized FDG counts in relation to defined resting perfusion defects as compared with a reference database, (iii) all regions match/mismatch, which computes the area with a 10% increase in normalized FDG counts in relation to the left ventricle resting perfusion distribution, and (iv) percentage max FDG match/mismatch, which defines the area with FDG uptake greater than 60% of the maximum LVM FDG counts within defined perfusion defects as determined by the reference database. The primary endpoint for this analysis was cardiac death. RESULTS: During the follow-up period (22+/-14 months), 19 patients (18%) died; in 17 of these the cause of death was cardiac. Using univariate analysis, none of the methods were predictive of cardiac death. Receiver operating characteristic analysis defined the optimal thresholds for the extent of myocardial viability for the four tools in the prediction of cardiac death: FDG alone=20%, low flow match/mismatch=15%, all regions match/mismatch=35%, and percentage max FDG match/mismatch=20%. A censored survival analysis using a Kaplan-Meier method showed a statistically significant difference between patients with cardiac death and those with no cardiac death using only the low flow match/mismatch (hazard ratio=0.29, P=0.01) and percentage max FDG match/mismatch criteria (hazard ratio=0.23, P=0.005) tools. CONCLUSION: The low flow match/mismatch and percentage max FDG match/mismatch quantitative PET tools are useful for prognostic stratification of patients with ischemic cardiomyopathy undergoing myocardial viability assessment.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Fluordesoxiglucose F18 , Isquemia Miocárdica/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Circulação Coronária , Feminino , Seguimentos , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Radioisótopos de Rubídio , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
16.
J Nucl Cardiol ; 15(3): 383-91, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18513645

RESUMO

BACKGROUND: Multiharmonic phase analysis (MHPA) was developed to assess left-ventricular dyssynchrony from gated myocardial perfusion single-photon emission computed tomography (GSPECT) studies. This study was intended to determine the temporal resolution of MHPA. METHODS: A reference normal GSPECT study with 128 frames/cycle was simulated using NCAT, a nonuniform rational B-splines-based cardiac torso phantom. It was shifted in the time domain to insert phase delays. Realistic GSPECT studies (8 or 16 frames/cycle) were then obtained by down-sampling the reference and shifted studies. All GSPECT projections were generated with attenuation, scatter, collimator blurring, and Poisson noise. Seventeen regional phases were calculated from the GSPECT reconstructions (filtered back-projection without compensation for physical factors), using linear interpolation for the reference study, and MHPA for the realistic studies. Comparing the regional phases between the realistic studies without and with shifts determined whether MHPA could identify certain phase delays. RESULTS: When there were enough counts/pixel (>10 counts/pixel), MHPA with either 1, 2, or 3 harmonics could resolve a phase difference of 5.6 degrees , corresponding to 1/64 of the cardiac cycle. CONCLUSIONS: With clinically equivalent counts, the temporal resolution of MHPA is 1/64 of a cardiac cycle. Achieving this high temporal resolution from data with low temporal resolution demonstrates the benefit of replacing discrete points with continuous harmonic functions.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem do Acúmulo Cardíaco de Comporta/instrumentação , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
19.
Proc Natl Acad Sci U S A ; 104(43): 17146-51, 2007 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-17940032

RESUMO

In humans, the wakeful resting condition is characterized by a default mode of brain function involving high levels of activity within a functionally connected network of brain regions. This network has recently been implicated in mental self-projection into the past, the future, or another individual's perspective. Here we use [(18)F]-fluorodeoxyglucose positron emission tomography imaging to assess resting-state brain activity in our closest living relative, the chimpanzee, as a potential window onto their mental world and compare these results with those of a human sample. We find that, like humans, chimpanzees show high levels of activity within default mode areas, including medial prefrontal and medial parietal cortex. Chimpanzees differ from our human sample in showing higher levels of activity in ventromedial prefrontal cortex and lower levels of activity in left-sided cortical areas involved in language and conceptual processing in humans. Our results raise the possibility that the resting state of chimpanzees involves emotionally laden episodic memory retrieval and some level of mental self-projection, albeit in the absence of language and conceptual processing.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Pan troglodytes/fisiologia , Descanso/fisiologia , Adolescente , Adulto , Animais , Comportamento Animal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
20.
J Nucl Cardiol ; 14(4): 420-32, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17679051

RESUMO

Single photon emission computed tomography (SPECT) myocardial perfusion imaging has attained widespread clinical acceptance as a standard of care for patients with known or suspected coronary artery disease. A significant contribution to this success has been the use of computer techniques to provide objective quantitative assessment in interpreting these studies. We have implemented the Emory Cardiac Toolbox (ECTb) as a pipeline to distribute the software tools that we and others have researched, developed, and validated to be clinically useful so that diagnosticians everywhere can benefit from our work. Our experience has demonstrated that integration of all software tools in a common platform is the optimal approach to promote both accuracy and efficiency. Important attributes of the ECTb approach are (1) our extensive number of normal perfusion databases for SPECT and positron emission tomography (PET) studies, each created with at least 150 patients; (2) our use of Fourier analysis of regional thickening to ensure proper temporal resolution and to allow accurate measurement of left ventricular function and dyssynchrony; (3) our development of PET tools to quantify myocardial hibernation and viability; (4) our development of 3-dimensional displays and the use of these displays as a platform for image fusion of perfusion and computed tomography angiography; and (5) the use of expert systems for decision support. ECTb is an important tool for extracting quantitative parameters from all types of cardiac radionuclide distributions. ECTb should continue to play an important role in establishing cardiac SPECT and PET for flow, function, metabolism, and innervation clinical applications.


Assuntos
Cardiologia/métodos , Diagnóstico por Imagem/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Centros Médicos Acadêmicos , Cardiologia/instrumentação , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Técnicas de Apoio para a Decisão , Diagnóstico por Imagem/instrumentação , Análise de Fourier , Georgia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/métodos , Linguagens de Programação , Radiografia , Software , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...