Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Physiol Meas ; 39(11): 114003, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30398165

RESUMO

OBJECTIVE: Recently great attention has been paid to innovative cardiovascular biomarkers obtained from wave separation (WS), wave intensity (WI) and reservoir-wave (RW) theories. All these approaches share a requirement for pressure information. The aim of this study was to evaluate differences in WS-, WI- and RW-derived parameters obtained achieving pressure waveforms in different ways. APPROACH: Twenty-two individuals (49 ± 17 years, 59% males) were examined. Common carotid blood flow waveforms were obtained from pulsed-wave Doppler images. Carotid pressure waveforms were achieved in four different ways: (1) with applanation tonometry, used as a reference method; (2) linear scaling from an ultrasound (US)-derived diameter curve; (3) exponential scaling from a US-derived diameter curve; and (4) linear scaling from an accelerometric-derived diameter signal. For each case, the reflection magnitude (RM) and index (RI) were obtained from the WS. The amplitude of the first positive peak (W 1), of the second positive peak (W 2) and of the negative peak (W b) were calculated from the WI, while the maximum of the reservoir (maxPr) and the excess (maxPex) pressure were achieved from the RW. MAIN RESULTS: According to the intra-class coefficient values, the agreement between the standard method and all the others was excellent for the RM (linear: 0.82; exponential: 0.83; accelerometric: 0.86), RI (linear: 0.84; exponential: 0.85; accelerometric: 0.87), maxPr (linear: 0.97; exponential: 0.96; accelerometric: 0.97) and maxPex (linear: 0.85; exponential: 0.87; accelerometric: 0.89), while only a fair/good level was reached for W 1 (linear: 0.67; exponential: 0.77; accelerometric: 0.52), W 2 (linear: 0.52; exponential: 0.69; accelerometric: 0.83) and W b (linear: 0.60; exponential: 0.44; accelerometric: 0.50). SIGNIFICANCE: Measuring carotid pressure waveforms with different approaches does not influence the cardiovascular parameters obtained by WS and RW; those derived by WI are affected by the carotid pressure curve employed.


Assuntos
Pressão Sanguínea , Artérias Carótidas/fisiologia , Processamento de Sinais Assistido por Computador , Feminino , Humanos , Masculino , Manometria , Pessoa de Meia-Idade
2.
Int J Obes (Lond) ; 42(3): 518-524, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28883542

RESUMO

BACKGROUND/OBJECTIVES: Obesity is reaching epidemic proportions and is associated with increased risk factors for cardiovascular disease. Leptin-deficient mice (ob/ob) are widely employed to investigate obesity. Aim of this study was to provide a micro-ultrasound (µUS) longitudinal evaluation of the ob/ob mouse model in terms of cardiovascular effects, consequences for renal microcirculation and liver fat accumulation. SUBJECTS/METHODS: Sixteen wild-type (wt) and eleven ob/ob male mice were studied at 8 (T0) and 25 (T1) weeks of age with a µUS system (Vevo2100) and B-mode and Doppler images were acquired. Cardiac output (CO), ejection fraction (EF), stroke volume (SV), fractional shortening (FS) and E/A ratio were measured from cardiac images. Mean diameter (Dmabd, Dmcar), relative distension (relDabd and relDcar) and pulse wave velocity (PWVabd and PWVcar) were obtained for both abdominal aorta and common carotid. As regards renal microcirculation, renal resistivity and pulsatility index (RI and PI) were assessed. The ratio between grey levels related to liver and kidney (Steato-Score) was used as index of hepatic steatosis. RESULTS: At T0, ob/ob mice showed reduced SV, EF, CO and relDabd values and increased LVmass, PWVabd, RI, PI and Steato-score measurements. The same comparison repeated at T1 highlighted similar results for SV, EF, CO, RI, PI and Steato-Score; furthermore, obese mice showed reduced Dmabd and Dmcar measurements in comparison with lean controls. The longitudinal analysis showed an increase in LVmass and Dmabd and a reduction of FS, EF, CO, relDabd and relDcar for wt animals, while no differences were found for the ob/ob group. CONCLUSIONS: ob/ob mice presented a premature cardiac dysfunction without a further age-related deterioration and a reduction in the abdominal aorta and carotid artery mean diameter in adult age. The proposed analysis can represent a valid approach for longitudinal studies aimed at testing new therapeutic strategies or for characterizing other mouse models.


Assuntos
Rim/patologia , Fígado/patologia , Miocárdio/patologia , Obesidade/diagnóstico por imagem , Obesidade/patologia , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Glicemia/análise , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/patologia , Modelos Animais de Doenças , Ecocardiografia , Coração/diagnóstico por imagem , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Camundongos , Camundongos Obesos , Volume Sistólico/fisiologia , Ultrassonografia
3.
Sci Rep ; 7: 46350, 2017 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-28397865

RESUMO

An enhanced resistive switching (RS) effect is observed in Pt/BaTiO3(BTO)/ITO ferroelectric structures when a thin HfO2:Al2O3 (HAO) dielectric layer is inserted between Pt and BTO. The P-E hysteresis loops reveal the ferroelectric nature of both Pt/BTO/ITO and Pt/HAO/BTO/ITO structures. The relation between the RS and the polarization reversal is investigated at various temperatures in the Pt/HAO/BTO/ITO structure. It is found that the polarization reversal induces a barrier variation in the Pt/HAO/BTO interface and causes enhanced RS, which is suppressed at Curie temperature (Tc = 140 °C). Furthermore, the Pt/HAO/BTO/ITO structures show promising endurance characteristics, with a RS ratio >103 after 109 switching cycles, that make them potential candidates for resistive switching memory devices. By combining ferroelectric and dielectric layers this work provides an efficient way for developing highly efficient ferroelectric-based RS memory devices.

4.
Mater Sci Eng C Mater Biol Appl ; 39: 29-34, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24863193

RESUMO

This study presents the development of natural rubber-Ca/P blends, as promising candidates for biomedical purposes. The specific objective was the incorporation of Ca/P into a natural rubber polymeric matrix. Ca/P crystalline phases were synthesized by the sol-gel method and the polymeric matrices were produced using natural rubber extracted from latex of the Hevea brasiliensis. The shape and size of natural rubber particles present in the NR membrane, as well as, the way the Ca/P powder grains aggregate in the polymeric matrix were investigated, giving information about the interactions between the Ca/P and the natural rubber particles. Confocal fluorescence scanning microscopy measurements allowed us to propose a structure where the Ca/P grains are surrounded by natural rubber particles. This structure may mediate Ca(2+) release for tissue regeneration. The system investigated may open new horizons for development of a bandage which provides the controlled-release of biomaterials.


Assuntos
Tecnologia Biomédica/instrumentação , Borracha/química , Fosfatos de Cálcio/síntese química , Hevea/química , Látex/química , Microscopia Confocal , Extratos Vegetais/química , Proteínas/química
5.
J Colloid Interface Sci ; 410: 124-30, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24011562

RESUMO

We report on a low-cost and low-tech method for the preparation of luminescent micro- and millimeter elastomeric particles with asymmetric morphology. The method of fabrication consists in UV-irradiating soft urethane/urea fluorescent spheres, which are then extracted in toluene and dried. Wrinkles appear on the irradiated portions of the particles surfaces, and the spatial periodicity can be controlled with variation in UV irradiation time and the amount of the luminescent compound. The spheres are thus composed of an urethane/urea network in which the tris(8-hydroxyquinolinato)aluminum (Alq3) fluorescent compound was incorporated. The asymmetric morphology and the optical properties of the resultant particles have been confirmed by scanning electron microscopy, atomic force microscopy, optical microscopy, and UV-Vis spectrophotometry. The system shows negligible leaching, and the encapsulation of the Alq3 without recourse to covalent bonding to the polymeric matrix has the advantage of allowing the tuning of the spheres morphology and fluorescence.

6.
Percept Psychophys ; 63(7): 1201-13, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11766944

RESUMO

Excerpts from French operatic songs were used to evaluate the extent to which language and music compete for processing resources. Do these two dimensions conflict? Are they integrated into a single percept? Or are they independent? The final word of each excerpt was either semantically congruous or incongruous relative to the prior linguistic context and was sung either in or out of key. Participants were asked to detect either the semantic or the melodic incongruity (single task) or both (dual task). We predicted a dual-task deficit if these tasks conflicted and no deficit if they were either independent or integrated. In order to distinguish between these last two outcomes, trial-by-trial contingency analyses were also computed, predicting no correlation if the tasks were conflicting or independent, a positive correlation under the assumption of integration and a negative correlation if dividing attention is impossible. Our results show similar levels of performance in single and dual tasks and no correlation between dual-task judgments, thus suggesting that semantic and melodic aspects of language are processed by independent systems. In addition, a comparison between musicians and nonmusicians shows that these conclusions are independent of musical expertise.


Assuntos
Linguística , Música , Reconhecimento Psicológico , Percepção da Fala , Adolescente , Adulto , Feminino , Humanos , Masculino , Modelos Psicológicos , Curva ROC , Semântica
7.
Biol Psychol ; 46(1): 3-23, 1997 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-9255429

RESUMO

Two experiments examined the effects of disrupting the temporal patterns that develop during sentence reading and listening. Sentences were presented either visually, one word at a time (Experiment 1) or as natural speech (Experiment 2). Half of the sentences were familiar (proverbs or idioms) while the other half were constructed anew for these experiments. Within half the sentences, there was an unexpected 600-ms delay between the final two words. In both modalities, the amplitude of the N400 component of the event-related brain potential (ERP) to sentence final words was larger for unfamiliar than familiar sentences. The results in the two modalities differed, however, in that a Contingent Negative Variation (CNV) developed during the delay interval in the visual modality, whereas in the auditory modality the delay was marked by an emitted potential. The present results show that temporal patterns are processed differently in natural speech and in reading words presented one at a time in the center of a computer screen.


Assuntos
Percepção Auditiva/fisiologia , Potenciais Evocados Auditivos/fisiologia , Potenciais Evocados Visuais/fisiologia , Percepção de Forma/fisiologia , Leitura , Percepção da Fala/fisiologia , Estimulação Acústica , Adolescente , Adulto , Atenção/fisiologia , Variação Contingente Negativa/fisiologia , Discriminação Psicológica/fisiologia , Eletroencefalografia , Feminino , Humanos , Masculino , Música , Fonética , Tempo de Reação/fisiologia , Semântica
8.
Neurosci Lett ; 168(1-2): 101-5, 1994 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-8028758

RESUMO

Musicians and non-musicians were presented with short musical phrases that were either selected from the classical musical repertoire or composed for the experiment. The phrases terminated either in a congruous or a 'harmonically', 'melodically', or 'rhythmically' incongruous note. The brain waves produced by the end-notes differed greatly between musicians and non-musicians, and as a function of the subject's familiarity with the melodies and the type of incongruity. The timing of these brain waves revealed that musicians are faster than non-musicians in detecting incongruities. This study provides further neurophysiological evidence concerning the mechanisms underlying music perception and the differences between musical and linguistic processing.


Assuntos
Encéfalo/fisiologia , Eletroencefalografia , Potenciais Evocados Auditivos , Música , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...