Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Dev Cogn Neurosci ; 70: 101452, 2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39341120

RESUMO

The HEALthy Brain and Child Development (HBCD) Study, a multi-site prospective longitudinal cohort study, will examine human brain, cognitive, behavioral, social, and emotional development beginning prenatally and planned through early childhood. The acquisition of multimodal magnetic resonance-based brain development data is central to the study's core protocol. However, application of Magnetic Resonance Imaging (MRI) methods in this population is complicated by technical challenges and difficulties of imaging in early life. Overcoming these challenges requires an innovative and harmonized approach, combining age-appropriate acquisition protocols together with specialized pediatric neuroimaging strategies. The HBCD MRI Working Group aimed to establish a core acquisition protocol for all 27 HBCD Study recruitment sites to measure brain structure, function, microstructure, and metabolites. Acquisition parameters of individual modalities have been matched across MRI scanner platforms for harmonized acquisitions and state-of-the-art technologies are employed to enable faster and motion-robust imaging. Here, we provide an overview of the HBCD MRI protocol, including decisions of individual modalities and preliminary data. The result will be an unparalleled resource for examining early neurodevelopment which enables the larger scientific community to assess normative trajectories from birth through childhood and to examine the genetic, biological, and environmental factors that help shape the developing brain.

2.
Magn Reson Med ; 90(3): 852-862, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37154389

RESUMO

PURPOSE: The need to detect and quantify brain lactate accurately by MRS has stimulated the development of editing sequences based on J coupling effects. In J-difference editing of lactate, threonine can be co-edited and it contaminates lactate estimates due to the spectral proximity of the coupling partners of their methyl protons. We therefore implemented narrow-band editing 180° pulses (E180) in MEGA-PRESS acquisitions to resolve separately the 1.3-ppm resonances of lactate and threonine. METHODS: Two 45.3-ms rectangular E180 pulses, which had negligible effects 0.15-ppm away from the carrier frequency, were implemented in a MEGA-PRESS sequence with TE 139 ms. Three acquisitions were designed to selectively edit lactate and threonine, in which the E180 pulses were tuned to 4.1 ppm, 4.25 ppm, and a frequency far off resonance. Editing performance was validated with numerical analyses and acquisitions from phantoms. The narrow-band E180 MEGA and another MEGA-PRESS sequence with broad-band E180 pulses were evaluated in six healthy subjects. RESULTS: The 45.3-ms E180 MEGA offered a difference-edited lactate signal with lower intensity and reduced contamination from threonine compared to the broad-band E180 MEGA. The 45.3 ms E180 pulse had MEGA editing effects over a frequency range larger than seen in the singlet-resonance inversion profile. Lactate and threonine in healthy brain were both estimated to be 0.4 ± 0.1 mM, with reference to N-acetylaspartate at 12 mM. CONCLUSION: Narrow-band E180 MEGA editing minimizes threonine contamination of lactate spectra and may improve the ability to detect modest changes in lactate levels.


Assuntos
Encéfalo , Ácido Láctico , Humanos , Ácido Láctico/análise , Espectroscopia de Ressonância Magnética , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Treonina
3.
Magn Reson Med ; 87(3): 1150-1164, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34657302

RESUMO

PURPOSE: J-Difference editing (MEGA) provides an effective spectroscopic means of selectively measuring low-concentration metabolites having weakly coupled spins. The fractional inphase and antiphase coherences are determined by the radiofrequency (RF) pulses and inter-RF pulse intervals of the sequence. We examined the timings of the spectrally selective editing 180° pulses (E180) in MEGA-PRESS to maximize the edited signal amplitude in lactate at 3T. METHODS: The time evolution of the lactate spin coherences was analytically and numerically calculated for non-volume localized and single-voxel localized MEGA sequences. Single-voxel localized MEGA-PRESS simulations and phantom experiments were conducted for echo time (TE) 60-160 ms and for all possible integer-millisecond timings of the E180 pulses. Optimized E180 timings of 144, 103, and 109 ms TEs, tailored with simulation and phantom data, were tested in brain tumor patients in vivo. Lactate signals, broadened to singlet linewidths (~6 Hz), were compared between simulation, phantom, and in vivo data. RESULTS: Theoretical and experimental data indicated consistently that the MEGA-edited signal amplitude and width are sensitive to the E180 timings. In volume-localized MEGA, the lactate peak amplitudes in E180-on and difference spectra were maximized at specific E180 timings for individual TEs, largely due to the chemical-shift displacement effects. The E180 timings for maximum lactate peak amplitude were different from those of maximum inphase coherence in in vivo linewidth situations. CONCLUSION: In in vivo MEGA editing, the E180 pulse timings can be effectively used for manipulating the inphase and antiphase coherences and increasing the edited signal amplitude, following TE optimization.


Assuntos
Ácido Láctico , Ondas de Rádio , Frequência Cardíaca , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
4.
Magn Reson Med ; 86(4): 1818-1828, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33977579

RESUMO

PURPOSE: 1 H MRS provides a noninvasive tool for identifying mutations in isocitrate dehydrogenase (IDH). Quantification of the prominent 2-hydroxyglutarate (2HG) resonance at 2.25 ppm is often confounded by the lipid resonance at the same frequency in tumors with elevated lipids. We propose a new spectral fitting approach to separate these overlapped signals, therefore, improving 2HG evaluation. METHODS: TE 97 ms PRESS was acquired at 3T from 42 glioma patients. New lipid basis sets were created, in which the small lipid 2.25-ppm signal strength was preset with reference to the lipid signal at 0.9 ppm, incorporating published fat relaxation data. LCModel fitting using the new lipid bases (Fitting method 2) was conducted along with fitting using the LCModel built-in lipid basis set (Fitting method 1), in which the lipid 2.25-ppm signal is assessed with reference to the lipid 1.3-ppm signal. In-house basis spectra of low-molecular-weight metabolites were used in both fitting methods. RESULTS: Fitting method 2 showed marked improvement in identifying IDH mutational status compared with Fitting method 1. 2HG estimates from Fitting method 2 were overall smaller than those from Fitting method 1, which was because of differential assignment of the signal at 2.25 ppm to lipids. In receiver operating characteristic analysis, Fitting method 2 provided a complete distinction between IDH mutation and wild-type whereas Fitting method 1 did not. CONCLUSION: The data suggest that 1 H MR spectral fitting using the new lipid basis set provides a robust fitting strategy that improves 2HG evaluation in brain tumors with elevated lipids.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Glutaratos , Humanos , Lipídeos , Espectroscopia de Ressonância Magnética
5.
Neuro Oncol ; 22(7): 1018-1029, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32055850

RESUMO

BACKGROUND: High-grade gliomas likely remodel the metabolic machinery to meet the increased demands for amino acids and nucleotides during rapid cell proliferation. Glycine, a non-essential amino acid and intermediate of nucleotide biosynthesis, may increase with proliferation. Non-invasive measurement of glycine by magnetic resonance spectroscopy (MRS) was evaluated as an imaging biomarker for assessment of tumor aggressiveness. METHODS: We measured glycine, 2-hydroxyglutarate (2HG), and other tumor-related metabolites in 35 glioma patients using an MRS sequence tailored for co-detection of glycine and 2HG in gadolinium-enhancing and non-enhancing tumor regions on 3T MRI. Glycine and 2HG concentrations as measured by MRS were correlated with tumor cell proliferation (MIB-1 labeling index), expression of mitochondrial serine hydroxymethyltransferase (SHMT2), and glycine decarboxylase (GLDC) enzymes, and patient overall survival. RESULTS: Elevated glycine was strongly associated with presence of gadolinium enhancement, indicating more rapidly proliferative disease. Glycine concentration was positively correlated with MIB-1, and levels higher than 2.5 mM showed significant association with shorter patient survival, irrespective of isocitrate dehydrogenase status. Concentration of 2HG did not correlate with MIB-1 index. A high glycine/2HG concentration ratio, >2.5, was strongly associated with shorter survival (P < 0.0001). GLDC and SHMT2 expression were detectable in all tumors with glycine concentration, demonstrating an inverse correlation with GLDC. CONCLUSIONS: The data suggest that aggressive gliomas reprogram glycine-mediated one-carbon metabolism to meet the biosynthetic demands for rapid cell proliferation. MRS evaluation of glycine provides a non-invasive metabolic imaging biomarker that is predictive of tumor progression and clinical outcome. KEY POINTS: 1. Glycine and 2-hydroxyglutarate in glioma patients are precisely co-detected using MRS at 3T.2. Tumors with elevated glycine proliferate and progress rapidly.3. A high glycine/2HG ratio is predictive of shortened patient survival.


Assuntos
Neoplasias Encefálicas , Glioma , Adulto , Idoso , Biomarcadores , Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste , Feminino , Gadolínio , Glioma/diagnóstico por imagem , Glutaratos , Glicina , Humanos , Isocitrato Desidrogenase/genética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Adulto Jovem
6.
Magn Reson Med ; 79(4): 1851-1861, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28833542

RESUMO

PURPOSE: To develop echo-planar spectroscopic imaging (EPSI) with large spectral width and accomplish high-resolution imaging of 2-hydroxyglutarate (2HG) at 7 T. METHODS: We designed a new EPSI readout scheme at 7 T. Data were recorded with dual-readout alternated gradients and combined according to the gradient polarity. Following validation of its performance in phantoms, the new readout scheme, together with previously reported 2HG-optimized magnetic resonance spectroscopy (point-resolved spectroscopy echo time of 78 ms), was used for time-efficient and high-resolution imaging of 2HG and other metabolites in five glioma patients before treatment. Unsuppressed water, acquired with EPSI, was used as reference for multichannel combination, eddy-current compensation, and metabolite quantification. Spectral fitting was conducted with the LCModel using in-house calculated basis sets. RESULTS: Using a readout gradient strength of 9.5 mT/m and slew rate of 90 mT/m/ms, dual-readout alternated gradients EPSI permitted 1638-Hz spectral width with 6 × 6 mm2 in-plane resolution at 7 T. Phantom data indicated that dual-readout alternated gradients EPSI provides proper metabolite signals and induces much less frequency drifts than conventional EPSI. For a spatial resolution of 0.5 mL, 2HG was detected in tumors with precision (Cramer-Rao lower bound < 10%). The 2HG was estimated to be 2.3 to 3.3 mM in tumors of three patients with biopsy-proven isocitrate dehydrogenase (IDH) mutant gliomas. The 2HG was undetectable in an IDH wild-type glioblastoma. For a radiographically suggested glioma, the estimated 2HG of 2.3 ± 0.2 mM (Cramer-Rao lower bound < 10%) indicated that the lesion may be an IDH mutant glioma. CONCLUSIONS: The data indicated that the dual-readout alternated gradients EPSI can provide reliable high-resolution imaging of 2HG in glioma patients at 7 T in vivo. Magn Reson Med 79:1851-1861, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem Ecoplanar/métodos , Glioma/diagnóstico por imagem , Glutaratos/química , Espectroscopia de Ressonância Magnética/métodos , Adulto , Biomarcadores , Neoplasias Encefálicas/genética , Feminino , Glioma/genética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Isocitrato Desidrogenase/genética , Masculino , Pessoa de Meia-Idade , Mutação , Oligodendroglioma/diagnóstico por imagem , Oligodendroglioma/genética , Imagens de Fantasmas
7.
NMR Biomed ; 30(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28548710

RESUMO

Glycine (Gly) has been implicated in several neurological disorders, including malignant brain tumors. The precise measurement of Gly is challenging largely as a result of the spectral overlap with myo-inositol (mI). We report a new triple-refocusing sequence for the reliable co-detection of Gly and mI at 3 T and for the evaluation of Gly in healthy and tumorous brain. The sequence parameters were optimized with density-matrix simulations and phantom validation. With a total TE of 134 ms, the sequence gave complete suppression of the mI signal between 3.5 and 3.6 ppm and, consequently, well-defined Gly (3.55 ppm) and mI (3.64 ppm) peaks. In vivo 1 H magnetic resonance spectroscopy (MRS) data were acquired from the gray matter (GM)-dominant medial occipital and white matter (WM)-dominant left parietal regions in six healthy subjects, and analyzed with LCModel using in-house-calculated basis spectra. Tissue segmentation was performed to obtain the GM and WM contents within the MRS voxels. Metabolites were quantified with reference to GM-rich medial occipital total creatine at 8 mM. The Gly and mI concentrations were estimated to be 0.63 ± 0.05 and 8.6 ± 0.6 mM for the medial occipital and 0.34 ± 0.05 and 5.3 ± 0.8 mM for the left parietal regions, respectively. From linear regression of the metabolite estimates versus fractional GM content, the concentration ratios between pure GM and pure WM were estimated to be 2.6 and 2.1 for Gly and mI, respectively. Clinical application of the optimized sequence was performed in four subjects with brain tumor. The Gly levels in tumors were higher than those of healthy brain. Gly elevation was more extensive in a post-contrast enhancing region than in a non-enhancing region. The data indicate that the optimized triple-refocusing sequence may provide reliable co-detection of Gly and mI, and alterations of Gly in brain tumors can be precisely evaluated.


Assuntos
Neoplasias Encefálicas/metabolismo , Encéfalo/metabolismo , Glicina/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Substância Cinzenta/metabolismo , Humanos , Inositol/metabolismo , Modelos Lineares , Masculino , Imagens de Fantasmas
8.
Magn Reson Med ; 77(3): 936-944, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-26991680

RESUMO

PURPOSE: To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS: The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring resonances of γ-aminobutyric acid (GABA), glutamate (Glu), and glutamine (Gln). MRS data were acquired from 12 subjects with gliomas in vivo and analyzed with LCModel using calculated basis spectra. Metabolite levels were quantified using unsuppressed short echo time (TE) water as a reference. RESULTS: The PRESS TE was optimized as TE = 78 ms (TE1 = 58 ms and TE2 = 20 ms), at which the 2HG 2.25 ppm resonance appeared as a temporally maximum inverted narrow peak and the GABA, Glu, and Gln resonances between 2.2 and 2.5 ppm were all positive peaks. The PRESS TE = 78 ms method offered improved discrimination of 2HG from Glu, Gln, and GABA when compared with short-TE MRS. 2HG was detected in all patients enrolled in the study, the estimated 2HG concentrations ranging from 1.0 to 6.2 mM, with percentage standard deviation of 2%-7%. CONCLUSION: Data indicate that the optimized MRS provides good selectivity of 2HG from other metabolite signals and may confer reliable in vivo detection of 2HG at relatively low concentrations. Magn Reson Med 77:936-944, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/metabolismo , Glutaratos/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Encéfalo/metabolismo , Encéfalo/patologia , Neoplasias Encefálicas/patologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Magn Reson Med ; 78(1): 40-48, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27454352

RESUMO

PURPOSE: To test the efficacy of triple-refocusing MR spectroscopy (MRS) for improved detection of 2-hydroxyglutarate (2HG) in brain tumors at 3T in vivo. METHODS: The triple-refocusing sequence parameters were tailored at 3T, with density-matrix simulations and phantom validation, for enhancing the 2HG 2.25-ppm signal selectivity with respect to the adjacent resonances of glutamate (Glu), glutamine (Gln), and gamma-aminobutyric acid (GABA). In vivo MRS data were acquired from 15 glioma patients and analyzed with LCModel using calculated basis spectra. Metabolites were quantified with reference to water. RESULTS: A triple-refocusing sequence (echo time = 137 ms) was obtained for 2HG detection. The 2HG 2.25-ppm signal was large and narrow while the Glu and Gln signals between 2.2 and 2.3 ppm were minimal. The optimized triple refocusing offered improved separation of 2HG from Glu, Gln and GABA when compared with published MRS methods. 2HG was detected in all 15 patients, the estimated 2HG concentrations ranging from 2.4 to 15.0 mM, with Cramer-Rao lower bounds of 2%-11%. The 2HG estimates did not show significant correlation with total choline. CONCLUSION: The optimized triple refocusing provides excellent 2HG signal discrimination from adjacent resonances and may confer reliable in vivo measurement of 2HG at relatively low concentrations. Magn Reson Med 78:40-48, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Biomarcadores Tumorais/análise , Neoplasias Encefálicas/química , Neoplasias Encefálicas/diagnóstico , Glutaratos/análise , Espectroscopia de Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Neoplasias Encefálicas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Clin Oncol ; 34(33): 4030-4039, 2016 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-28248126

RESUMO

Purpose Proton magnetic resonance spectroscopy (MRS) of the brain can detect 2-hydroxyglutarate (2HG), the oncometabolite produced in neoplasms harboring a mutation in the gene coding for isocitrate dehydrogenase ( IDH). We conducted a prospective longitudinal imaging study to determine whether quantitative assessment of 2HG by MRS could serve as a noninvasive clinical imaging biomarker for IDH-mutated gliomas. Patients and Methods 2HG MRS was performed in 136 patients using point-resolved spectroscopy at 3 T in parallel with standard clinical magnetic resonance imaging and assessment. Data were analyzed in patient cohorts representing the major phases of the glioma clinical course and were further subgrouped by histology and treatment type to evaluate 2HG. Histologic correlations were performed. Results Quantitative 2HG MRS was technically and biologically reproducible. 2HG concentration > 1 mM could be reliably detected with high confidence. During the period of indolent disease, 2HG concentration varied by less than ± 1 mM, and it increased sharply with tumor progression. 2HG concentration was positively correlated with tumor cellularity and significantly differed between high- and lower-grade gliomas. In response to cytotoxic therapy, 2HG concentration decreased rapidly in 1p/19q codeleted oligodendrogliomas and with a slower time course in astrocytomas and mixed gliomas. The magnitude and time course of the decrease in 2HG concentration and magnitude of the decrease in tumor volume did not differ between oligodendrogliomas treated with temozolomide or carmustine. Criteria for 2HG MRS were established to make a presumptive molecular diagnosis of an IDH mutation in gliomas technically unable to undergo a surgical procedure. Conclusion 2HG concentration as measured by MRS was reproducible and reliably reflected the disease state. These data provide a basis for incorporating 2HG MRS into clinical management of IDH-mutated gliomas.


Assuntos
Biomarcadores/análise , Química Encefálica , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/genética , Glioma/diagnóstico , Glioma/genética , Glutaratos/análise , Espectroscopia de Ressonância Magnética , Adolescente , Adulto , Idoso , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/patologia , Feminino , Glioma/tratamento farmacológico , Glioma/patologia , Humanos , Isocitrato Desidrogenase/genética , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Magn Reson Med ; 75(1): 52-62, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25651788

RESUMO

PURPOSE: MR spectroscopic imaging (SI) of glycine (Gly) in the human brain is challenging due to the interference of the abundant neighboring J-coupled resonances. Our aim is to accomplish reliable imaging of Gly in healthy brain and brain tumors using an optimized MR sequence scheme at 3 tesla. METHODS: Two-dimensional (1)H SI was performed with a point-resolved spectroscopy scheme. An echo time of 160 ms was used for separation between Gly and myo-inositol signals. Data were collected from eight healthy volunteers and 14 subjects with gliomas. Spectra were analyzed with the linear combination model using numerically calculated basis spectra. Metabolite concentrations were estimated with reference to creatine in white matter (WM) regions at 6.4 molar concentrations (mM). RESULTS: From a linear regression analysis with respect to the fractional gray matter (GM) content, the Gly concentrations in pure GM and WM in healthy brains were estimated to be 1.1 and 0.3 mM, respectively. Gly was significantly elevated in tumors. The tumor-to-contralateral Gly concentration ratio was more extensive with higher grades, showing ∼ 10-fold elevation of Gly in glioblastomas. CONCLUSION: The Gly level is significantly different between GM and WM in healthy brains. Our data indicate that SI of Gly may provide a biomarker of brain tumor malignancy.


Assuntos
Algoritmos , Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Idoso , Neoplasias Encefálicas/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Adulto Jovem
12.
Magn Reson Med ; 73(6): 2094-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25046359

RESUMO

PURPOSE: To evaluate the T2 relaxation time of lactate (Lac) in brain tumors and the correlation of the T2 and concentration with tumor grades. METHODS: Eight pairs of the subecho time sets of point-resolved spectroscopy were selected between 58 and 268 ms, with numerical and phantom analyses, for Lac T2 measurement. In vivo spectra were acquired from 24 subjects with gliomas (13 low grade and 11 high grade) and analyzed with LCModel using numerically-calculated basis spectra. The metabolite T2 relaxation time was obtained from monoexponential fitting of the multi-echo time (TE) signal estimates versus TE. The metabolite concentration was estimated from the zero-TE extrapolation of the T2 fits. RESULTS: The Lac T2 was estimated to be approximately 240 ms, without a significant difference between low and high grade tumors. The Lac concentration was estimated to be 4.1 ± 3.4 and 7.0 ± 4.7 mM for low and high grades respectively, but the difference was not significant. CONCLUSION: The Lac T2 was similar among gliomas regardless of their tumor grades. This suggests that the T2 value from this study may be applicable to obtain the T2 relaxation-free estimates of Lac in a subset of brain tumors.


Assuntos
Neoplasias Encefálicas/metabolismo , Glioma/metabolismo , Ácido Láctico/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Química Encefálica , Colina/metabolismo , Creatina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
13.
NMR Biomed ; 27(10): 1167-75, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25088346

RESUMO

The (1)H resonances of γ-aminobutyric acid (GABA) in the human brain in vivo are extensively overlapped with the neighboring abundant resonances of other metabolites and remain indiscernible in short-TE MRS at 7 T. Here we report that the GABA resonance at 2.28 ppm can be fully resolved by means of echo time optimization of a point-resolved spectroscopy (PRESS) scheme. Following numerical simulations and phantom validation, the subecho times of PRESS were optimized at (TE, TE2) = (31, 61) ms for detection of GABA, glutamate (Glu), glutamine (Gln), and glutathione (GSH). The in vivo feasibility of the method was tested in several brain regions in nine healthy subjects. Spectra were acquired from the medial prefrontal, left frontal, medial occipital, and left occipital brain and analyzed with LCModel. Following the gray and white matter (GM and WM) segmentation of T1 -weighted images, linear regression of metabolite estimates was performed against the fractional GM contents. The GABA concentration was estimated to be about seven times higher in GM than in WM. GABA was overall higher in frontal than in occipital brain. Glu was about twice as high in GM as in WM in both frontal and occipital brain. Gln was significantly different between frontal GM and WM while being similar between occipital GM and WM. GSH did not show significant dependence on tissue content. The signals from N-acetylaspartylglutamate were clearly resolved, giving the concentration more than 10 times higher in WM than in GM. Our data indicate that the PRESS TE = 92 ms method provides an effective means for measuring GABA and several challenging J-coupled spin metabolites in human brain at 7 T.


Assuntos
Córtex Cerebral/química , Espectroscopia de Prótons por Ressonância Magnética/métodos , Ácido gama-Aminobutírico/análise , Adulto , Córtex Cerebral/anatomia & histologia , Colina/análise , Simulação por Computador , Creatina/análise , Dipeptídeos/análise , Estudos de Viabilidade , Feminino , Lobo Frontal/química , Glutamatos/análise , Glutamina/análise , Glutationa/análise , Humanos , Masculino , Lobo Occipital/química , Imagens de Fantasmas , Córtex Pré-Frontal/química , Prótons , Substância Branca/química , Adulto Jovem
14.
Magn Reson Med ; 72(2): 316-23, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24123337

RESUMO

PURPOSE: To test whether citrate is elevated in adult patients with gliomas using (1)H magnetic resonance spectroscopy (MRS) at 3T in vivo. METHODS: Thirty-four adult patients were enrolled in the study, including six subjects with glioblastomas, eight subjects with astrocytomas (World Health Organization grade 3, n = 5; grade 2, n = 3), and 20 subjects with oligodendrogliomas (grade 3, n = 5; grade 2, n = 15). Five healthy volunteers were studied for baseline citrate data. Single-voxel localized spectra were collected with point-resolved spectroscopy (PRESS) echo times of 35 and 97 ms and were analyzed with LCModel software using numerically calculated basis spectra that included the effects of the PRESS radiofrequency and gradient pulses. RESULTS: Citrate was not measurable by MRS in healthy brain but was detected in tumor patients at both echo times. The citrate concentration was estimated to be as high as 1.8 mM with reference to water at 42 M, with Cramér-Rao lower bounds (CRLB) as low as 5%. The mean citrate level was 0.7 ± 0.4 mM (mean ± SD, n = 32) with a median CRLB of ∼12%. No correlation was identified between citrate concentration and tumor grade or histological type. CONCLUSION: Citrate was increased in the majority of gliomas in adult patients. The elevated citrate in our data indicates an altered metabolic state of tumor relative to healthy brain.


Assuntos
Biomarcadores Tumorais/análise , Química Encefálica , Neoplasias Encefálicas/química , Ácido Cítrico/análise , Glioma/química , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
Radiology ; 262(3): 985-94, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22357898

RESUMO

PURPOSE: To retrospectively evaluate the fidelity of magnetic resonance (MR) spectroscopic imaging data preservation at a range of accelerations by using compressed sensing. MATERIALS AND METHODS: The protocols were approved by the institutional review board of the university, and written informed consent to acquire and analyze MR spectroscopic imaging data was obtained from the subjects prior to the acquisitions. This study was HIPAA compliant. Retrospective application of compressed sensing was performed on 10 clinical MR spectroscopic imaging data sets, yielding 600 voxels from six normal brain data sets, 163 voxels from two brain tumor data sets, and 36 voxels from two prostate cancer data sets for analysis. The reconstructions were performed at acceleration factors of two, three, four, five, and 10 and were evaluated by using the root mean square error (RMSE) metric, metabolite maps (choline, creatine, N-acetylaspartate [NAA], and/or citrate), and statistical analysis involving a voxelwise paired t test and one-way analysis of variance for metabolite maps and ratios for comparison of the accelerated reconstruction with the original case. RESULTS: The reconstructions showed high fidelity for accelerations up to 10 as determined by the low RMSE (< 0.05). Similar means of the metabolite intensities and hot-spot localization on metabolite maps were observed up to a factor of five, with lack of statistically significant differences compared with the original data. The metabolite ratios of choline to NAA and choline plus creatine to citrate did not show significant differences from the original data for up to an acceleration factor of five in all cases and up to that of 10 for some cases. CONCLUSION: A reduction of acquisition time by up to 80%, with negligible loss of information as evaluated with clinically relevant metrics, has been successfully demonstrated for hydrogen 1 MR spectroscopic imaging.


Assuntos
Neoplasias Encefálicas/metabolismo , Compressão de Dados , Espectroscopia de Ressonância Magnética/métodos , Neoplasias da Próstata/metabolismo , Algoritmos , Análise de Variância , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Colina/metabolismo , Ácido Cítrico/metabolismo , Creatina/metabolismo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Estudos Retrospectivos
16.
Nat Med ; 18(4): 624-9, 2012 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-22281806

RESUMO

Mutations in isocitrate dehydrogenases 1 and 2 (IDH1 and IDH2) have been shown to be present in most World Health Organization grade 2 and grade 3 gliomas in adults. These mutations are associated with the accumulation of 2-hydroxyglutarate (2HG) in the tumor. Here we report the noninvasive detection of 2HG by proton magnetic resonance spectroscopy (MRS). We developed and optimized the pulse sequence with numerical and phantom analyses for 2HG detection, and we estimated the concentrations of 2HG using spectral fitting in the tumors of 30 subjects. Detection of 2HG correlated with mutations in IDH1 or IDH2 and with increased levels of D-2HG by mass spectrometry of the resected tumors. Noninvasive detection of 2HG may prove to be a valuable diagnostic and prognostic biomarker.


Assuntos
Neoplasias Encefálicas/genética , Neoplasias Encefálicas/metabolismo , Glioma/genética , Glioma/metabolismo , Glutaratos , Isocitrato Desidrogenase/genética , Mutação/genética , Algoritmos , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Encéfalo/enzimologia , Mapeamento Encefálico , Colina/metabolismo , Creatina/metabolismo , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Estatística como Assunto
17.
NMR Biomed ; 25(4): 523-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21845738

RESUMO

Proton T(2) relaxation times of metabolites in the human brain were measured using point resolved spectroscopy at 3T in vivo. Four echo times (54, 112, 246 and 374 ms) were selected from numerical and phantom analyses for effective detection of the glutamate multiplet at ~ 2.35 ppm. In vivo data were obtained from medial and left occipital cortices of five healthy volunteers. The cortices contained predominantly gray and white matter, respectively. Spectra were analyzed with LCModel software using volume-localized calculated spectra of brain metabolites. The estimate of the signal strength vs. TE was fitted to a monoexponential function for estimation of apparent T(2) (T(2)(†)). T(2)(†) was estimated to be similar between the brain regions for creatine, choline, glutamate and myo-inositol, but significantly different for N-acetylaspartate singlet and multiplet. T(2)(†)s of glutamate and myo-inositol were measured as 181 ± 16 and 197 ± 14 ms (mean ± SD, N = 5) for medial occipital cortices, and 180 ± 12 and 196 ± 17 ms for left occipital cortices, respectively.


Assuntos
Ácido Aspártico/análogos & derivados , Encéfalo/metabolismo , Creatinina/análise , Ácido Glutâmico/análise , Inositol/análise , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Adulto , Ácido Aspártico/análise , Encéfalo/anatomia & histologia , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
18.
Magn Reson Med ; 66(3): 609-18, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21394775

RESUMO

Glycine is a key metabolic intermediate required for the synthesis of proteins, nucleic acids, and other molecules, and its detection in cancer could, therefore, provide biologically relevant information about the growth of the tumor. Here, we report measurement of glycine in human brain and gliomas by an optimized point-resolved spectroscopy sequence at 3 T. Echo time dependence of the major obstacle, myo-inositol (mI) multiplet, was investigated with numerical simulations, incorporating the 3D volume localization. The simulations indicated that a subecho pair (TE(1) , TE(2) ) = (60, 100) ms permits detection of both glycine and mI with optimum selectivity. In vivo validation of the optimized point-resolved spectroscopy was conducted on the right parietal cortex of five healthy volunteers. Metabolite signals estimated from LC Model were normalized with respect to the brain water signal, and the concentrations were evaluated assuming the total creatine concentration at 8 mM. The glycine concentration was estimated as 0.6 ± 0.1 mM (mean ± SD, n = 5), with a mean Cramér-Rao lower bound of 9 ± 1%. The point-resolved spectroscopy sequence was applied to measure the glycine levels in patients with glioblastoma multiforme. Metabolite concentrations were obtained using the water signal from the tumor mass. The study revealed that a subset of human gliomas contains glycine levels elevated 1.5-8 fold relative to normal.


Assuntos
Neoplasias Encefálicas/metabolismo , Glioblastoma/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Química Encefálica , Glicina/metabolismo , Humanos , Imageamento Tridimensional , Inositol/metabolismo , Espectroscopia de Ressonância Magnética/instrumentação , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...